• 제목/요약/키워드: Parallel-connected inverter

검색결과 88건 처리시간 0.026초

병렬운전하는 계통연계형 태양광 발전용 인버터의 단독운전 검출 성능 분석 (Performance Analysis of Anti-islanding Function for Grid-connected PV Inverter Systems under Parallel Connections)

  • 정영석;유병규;강기환
    • 한국태양에너지학회 논문집
    • /
    • 제33권5호
    • /
    • pp.34-40
    • /
    • 2013
  • Islanding phenomenon of photovoltaic system is undesirable because it leads to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized re-closure. Anti-islanding protection is an important technical requirement for grid-connected PV system. Until now, various anti-islanding methods for detecting and preventing islanding of photovoltaic and other distributed generations have been proposed. Most of them are focusing on the anti-islanding performance of single PV system according to the related international and domestic standard test procedures. There are few studies on the islanding phenomenon for multiple photovoltaic operation in parallel. This paper presents performance analysis of anti-islanding function for grid-connected PV inverter systems when several PV inverters are connected in parallel.

Accurate Power Sharing in Proportion for Parallel Connected Inverters by Reconstructing Inverter Output Impedance

  • Huang, Shengli;Luo, Jianguo
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1751-1759
    • /
    • 2018
  • This paper presents parallel-connected inverters to achieve accurate proportional power sharing. Due to line impedance mismatch, reactive power cannot be distributed proportionally when using the conventional $P-{\omega}$ and $\mathcal{Q}-E$ droop. In order to realize reactive proportional power sharing, the ratio of the droop coefficients should be inversely proportional to their power-sharing ratios. Meanwhile, the ratio of the line impedance should be inversely proportional to the desired power-sharing ratio, which is very difficult to be met in practice. In order to deal with this issue, a practical control strategy is presented. By measuring the PCC voltage and using the virtual impedance, the output impedance of individual inverters is reconstructed to counteract the line impedance effect. In order to guarantee system stability, a low pass filter is designed to suppress the bandwidth of the line compensation. Finally, the simulation and experimental results are given to verify the effectiveness of the proposed control strategy.

고주파 및 고전력 인버터 적용을 위한 Half-Bridge SIT의 병렬운전 특성고찰 (Parallel Operation of a Pair of SITs in order to raise the High Frequency and Power Half-Bridge Inverter)

  • 최상원;김진표;이종하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2234-2236
    • /
    • 1997
  • The SIT, a Static Induction Transistor, is a semiconductor switch that is also called the power junction field-effect transistor (power JFET). Its characteristics are similar to a MOSFET except that its power level is higher and its maximum frequency of operation is lower. The normal method to protect against internal circuit transients of the form of di/dt or dv/dt is the use of snubber circuits. However, the limits of di/dt and dv/dt are high enough for the SIT that it is possible to operate without snubber circuits. SITs can be connected in parallel in order to cope with higher load currents that the value of an individual device rating. The purpose of this study is to investigate the parallel operation of SITs. In this experiment, we used a half-bridge inverter, the output of inverter is up to almost 1MHz and 2kW. Experimental results show that the operation of parallel connected SITs are facilitated individually good current sharing. The reason is the positive temperature coefficient of resistance of the SIT.

  • PDF

병렬운전에서의 계통연계형 인버터의 단독운전 검출 (Islanding detection of grid-connected inverter in parallel operation)

  • 정영석;유병규;소정훈;유권종;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.232-233
    • /
    • 2007
  • In this paper, phenomenon of islanding parallel inverters in an ac-distributed system is proposed. The paper explores the test results of the parallel-connected inverters in grid-connected system. The test results are devised and analyzed taking into account the power quality and the islanding performance. The islanding test methods applied. Experimental results are provided from two 2 kVA inverters connected in parallel, showing the features of islanding test.

  • PDF

A Resonant Characteristics Analysis and Suppression Strategy for Multiple Parallel Grid-connected Inverters with LCL Filter

  • Sun, Jian-jun;Hu, Wei;Zhou, Hui;Jiang, Yi-ming;Zha, Xiao-ming
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1483-1493
    • /
    • 2016
  • Multiple parallel inverters have multiple resonant frequencies that are influenced by many factors. This often results in stability and power quality problems. This paper develops a multiple input multiple output model of grid-connected inverter systems using a closed-loop transfer function. The influence factors of the resonant characteristics are analyzed with the developed model. The analysis results show that the resonant frequency is closely related to the number, type and composition ratio of the parallel inverters. To suppress resonance, a scheme based on virtual impedance is presented, where the virtual impedance is emulated in the vicinity of the resonance frequency. The proposed scheme needs one inverter with virtual impedance control, which reduces the design complexity of the other inverter controllers. Simulation and experimental tests are carried out on two single phase converter-based setups. The results validate the correctness of the model, the analytical results and the resonant suppressing scheme.

단일 인버터로 두 대의 영구자석 동기전동기 병렬운전에 대한 공진특성해석 (The Resonance Characteristic Analysis for Speed Control of Parallel Connected Dual SPMSMs fed by a Single Inverter)

  • 윤철;권우현
    • 전기학회논문지
    • /
    • 제66권4호
    • /
    • pp.643-650
    • /
    • 2017
  • This pap4er analyzes resonance characteristics of a slave motor that is not controlled by load and parameter differences between Dual motors during parallel operation in middle-low speed. Dual SPMSMs(Surface mounted Permanent Magnet Synchronous Motor) connected in parallel to a single inverter controlled by the master and slave control in this paper. Based on the stability analysis of the SPMSM for a variation of torque angle, the 6th nonlinear state equation of the torque angle variation in the SIMM(Single Inverter Multi Motor) structure is derived according to a mathematical model for the dual motors. In general, an analysis of the 6th order nonlinear state equation is complex. Therefore, a resonance frequency generated from the slave motor is found from the characteristic equation of the 2nd order system obtained by linearization and model reduction near steady state operation point. Through simulations and experiments, it is confirmed that the stability analysis of the SPMSMs and state equation models are useful for the variation of the torque angle analyzed in this paper.

Resonance Characteristics Analysis of Grid-connected Inverter Systems based on Sensitivity Theory

  • Wu, Jian;Han, Wanqin;Chen, Tao;Zhao, Jiaqi;Li, Binbin;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.746-756
    • /
    • 2018
  • Harmonic resonance exists in grid-connected inverter systems. In order to determine the network components that contribute to harmonic resonance and the composition of the resonant circuit, sensitivity theory is applied to the resonance characteristic analysis. Based on the modal analysis, the theory of sensitivity is applied to derive a formula for determining the sensitivities of each network component parameter under a resonance circumstance that reflects the participation of the network component. The solving formula is derived for both parallel harmonic resonance and series harmonic resonance. This formula is adopted to a 4-node grid-connected test system. The analysis results reveal that for a certain frequency, the participation of parallel resonance and series resonance are not the same. Finally, experimental results demonstrate that the solving formula for sensitivity is feasible for grid-connected systems.

IPMSM 파라미터 변동에 따른 차세대 고속전철 시스템의 운전 특성 고찰 (Operation Characteristics Investigation of the Next Generation High Speed Railway System with respect to IPMSM Parameter Variation)

  • 박동규;서용훈;이상현;진강환;김윤호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.3133-3141
    • /
    • 2011
  • The next generation domestic high speed railway system is a power distributed type and uses vector control method for motor speed control. Nowadays, inverter driven induction motor system is widely used. However, recently PMSM drives are deeply considered as a alternative candidate instead of an induction motor drive system due to their advantages in efficiency, noise reduction and maintenance. The next-generation high speed train is composed of 2 converter units, 4 inverter units, and 4 Traction Motor units. Each motor is connected to the inverter directly. In this paper, the effect of IPMSM parameter variations to the system operation characteristics of the multi inverter drive high speed train system are investigated. The parallel connected inverter input-output characteristics are analyzed to the parameter mismatches of IPMSM using the 1C1M control simulator based on Matlab/Simulink.

  • PDF

마이크로그리드에서 에너지 저장시스템을 위한 무순단 절체 기능을 갖는 계통연계형 인버터의 병렬운전 제어기법 (Parallel Operation Control Method of Grid-connected Inverters with Seamless Transfer for Energy Storage System in Microgrid)

  • 박성열;김주하;정아진;최세완
    • 전력전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.200-206
    • /
    • 2016
  • In the microgrid, inverters for energy storage system are generally constructed in a parallel structure because of capacity expandability, convenience of system maintenance, and reliability improvement. Parallel inverters are required to provide stable voltage to the critical load in PCC and to accurately share the current between each inverter. Furthermore, when islanding occurs, the inverters should change its operating mode from grid-connected mode to stand-alone mode. However, during clearing time and control mode change, the conventional control method has a negative impact on the critical load, that is, severe fluctuating voltage. In this study, a parallel operation control method is proposed. This method provides seamless mode transfer for the entire transition period, including clearing time and control mode change, and has accurate current sharing between each inverter. The proposed control method is validated through simulation and experiment.

2 MW 풍력발전기용 병렬형 Inverter 개발 (Development of a Parallel Inverter for 2 MW Windpower Generator)

  • 최효진;권세진;손윤규;서재학;장성덕;오종석;강신일;이현영;권오정;이병철;황진수;류지윤
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.427-431
    • /
    • 2007
  • 본 논문에서는 750 kW 풍력발전용 인버터를 개발한 결과와 2년 동안의 현장실증을 통하여 얻어진 경험을 바탕으로 2 MW 영구자석형 동기발전기(PMSG, Permanent Magnet Synchronous Generator)의 전력변환을 위한 병렬형 인버터의 시뮬레이션과 이를 통한 설계와 제작 및 기본시험 과정을 소개하고자 한다.

  • PDF