• 제목/요약/키워드: Parallel magnetic field

검색결과 230건 처리시간 0.027초

HgBa_2Ca_2Cu_3O_{8+{\delta}}$ 초전도체 자화의 수치적 해석 (Numerical analysis of magnetization of HgBa$_2Ca_2Cu_3O_{8+{\delta}}$ superconductor)

  • 김봉준;김영철;김영진;백상민
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.218-221
    • /
    • 1999
  • Magnetization measurements have been carried out on grain aligned Hg-1223 with the applied field parallel to the c-axis. The temperature dependence of the lower critical field H$_{cl}$(T) was determined by considering the effect of the surface barrier on the magnetization. H$_{cl}$(T) have been determined .from magnetic hysteresis loops within the framework of the modified Kim-Anderson critical-state model, where the surface barrier and the lower critical field are explicitly considered. At high temperature, H$_{cl}$(T) is identified as H$_p$(T). This results are agreed with the theory of Bean-Livinston surface barriers.

  • PDF

Identification of linearly unstable modes in the near-Earth current disruption

  • Mok, Chin-Ook;Ryu, Chang-Mo
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2009년도 한국우주과학회보 제18권2호
    • /
    • pp.44.1-44.1
    • /
    • 2009
  • Identification of wave characteristics during current disruption events in the near-Earth geomagnetic tail region (~ 10 RE) is important to understand the substorm onset mechanism. In this paper, linear stability analysis in the ion-cyclotron grequency range, considering temperature anisotropy and cross-field flow is presented. It is found that the ion-cyclotron drift waves propagating in a quasi-perpendicular direction with respect to the ambient magnetic field are characterized by low frequencies ($\omega$ < $0.5{\Omega}ci$), while quasi-parallel waves have frequencies close to the ion-cyclotron frequency ($\omega{\sim}{\Omega}ci$). This finding is consistent with the observation by THEMIS spacecraft of a current disruption event in which a similar high- and low-frequency band structure is also present [A. T. Y. Lui, et al., J. Geophys. Res. 113, A00C06 (2008)]. It is also found that the quasi-perpendicular mode is excited by the ion cross-field flow.

  • PDF

Formation of a large-scale quasi-circular flare ribbon enclosing three-ribbon through two-step eruptive flares

  • Lim, Eun-Kyung;Yurchyshyn, Vasyl;Kumar, Pankaj;Cho, Kyuhyoun;Kim, Sujin;Cho, Kyung-Suk
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.42.1-42.1
    • /
    • 2016
  • The formation process and the dynamical properties of a large-scale quasi-circular flare ribbon were investigated using the SDO AIA and HMI data along with data from RHESSI and SOT. Within one hour time interval, two subsequent M-class flares were detected from the NOAA 12371 that had a ${\beta}{\gamma}{\delta}$ configuration with one bipolar sunspot group in the east and one unipolar spot in the west embedded in a decayed magnetic field. Earlier M2.0 flare was associated with a coronal loop eruption, and a two-ribbon structure formed within the bipolar sunspot group. On the other hand, the later M2.6 flare was associated with a halo CME, and a quasi-circular ribbon developed encircling the full active region. The observed quasi-circular ribbon was strikingly large in size spanning 650" in north-south and 500" in east-west direction. It showed the well-known sequential brightening in the clockwise direction during the decay phase of the M2.6 flare at the estimated speed of 160.7 km s-1. The quasi-circular ribbon also showed the radial expansion, especially in the southern part. Interestingly, at the time of the later M2.6 flare, the third flare ribbon parallel to the early two-ribbon structure also developed near the unipolar sunspot, then showed a typical separation in pair with the eastern most ribbon of the early two ribbons. The potential field reconstruction based on the PFSS model showed a fan shaped magnetic configuration including fan-like field lines stemming from the unipolar spot and fanning out toward the background decayed field. This large-scale fan-like field overarched full active region, and the footpoints of fan-like field lines were co-spatial with the observed quasi-circular ribbon. From the NLFF magnetic field reconstruction, we confirmed the existence of a twisted flux rope structure in the bipolar spot group before the first M2.0 flare. Hard X-ray emission signatures were detected at the site of twisted flux rope during the pre-flare phase of the M2.0 flare. Based on the analysis of both two-ribbon structure and quasi-circular ribbon, we suggest that a tether-cutting reconnection between sheared arcade overarching the twisted flux rope embedded in a fan-like magnetic field may have triggered the first M2.0 flare, then secondary M2.6 flare was introduced by the fan-spine reconnection because of the interaction between the expanding field and the nearby quasi-null and formed the observed large-scale quasi-circular flare ribbon.

  • PDF

2 차원 Si 종형 Hall 소자의 자기감도 개선 (Magnetic Sensitivity Improvement of 2-Dimensional Silicon Vertical Hall Device)

  • 류지구
    • 센서학회지
    • /
    • 제23권6호
    • /
    • pp.392-396
    • /
    • 2014
  • The 2-dimensional silicon vertical Hall devices, which are sensitive to X,Y components of the magnetic field parallel to the surface of the chip, are fabricated using a modified bipolar process. It consists of the thin p-layer at Si-$SiO_2$ interface and n-epi layer to improve the sensitivity and influence of interface effect. Experimental samples are a sensor type K with and type J without $p^+$ isolation dam adjacent to the center current electrode. The results for both type show a more high sensitivity than the former's 2-dimensional vertical Hall devices and a good linearity. The measured non-linearity is about 0.8%. The sensitivity of type J and type K are about 66 V/AT and 200 V/AT, respectively. This sensor's behavior can be explained by the similar J-FET model.

가전기기용전동기의 전자소음과 진동의 방지대책에 관한 연구 (Study on the Reduction Method of Magnetic Noise and Vibration in Home Electric Motors)

  • 황영문;조철제
    • 전기의세계
    • /
    • 제26권5호
    • /
    • pp.74-82
    • /
    • 1977
  • This study is to present a method for reductin of noise and vibration of home electric motors coupled to the mechanical load causing relatively big amplitude of vibration. The noise and vibration factors have been analysed in the divisions such as the pattern related to the armature reaction, the pattern related to the circulating current by induction and the other patterns those are affected by a dditive magnetic field and have an effect on mechanical constants. From the systematic mutual relations between the patterns and daping effects, it is possible to derive the fundamental measure for reduction of noise and vibration. Vibration measurements and analysis were carried out in accordance with the planned experimentation and thre object model was chosen randomly from the production line in a factory where home electric machines were mass-produced. Based on the above-mentioned fundamental measure, suppression effects on noise and vibration have been analysed according to the number of slots, the amount of rotor skew and the way the stator winding connection was series or parallel.

  • PDF

YBCO Bulk 초전도체 교류손실의 주파수 의존성 (Frequency dependence of AC loss in YBCO Bulk superconductor)

  • 예정희;나완수;김찬중;홍계원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.259-261
    • /
    • 1999
  • In this paper, we investigated the frequency dependences of AC loss and the magnetic properties of a superconductor using magnetization method. We used the YBCO bulk superconductor sample which has a square-shaped cross sectional area of $6mm{\times}6mm$. and 43mm-long in axial direction. The applied AC magnetic field was parallel to the direction of sample axis. It is observed that YBCO bulk has the diamagnetic properties. AC loss calculation of YBCO bulk superconductor was performed by evaluating the total area of magnetization traces. We performed two cases of experiments, one for $B_m<B_p$ and the other for $B_m<B_p$. The experiments showed that the AC loss dependences on frequency were different in each mode, as was indicated in other publications.

  • PDF

3차원 적분법을 이용한 변류기의 누설 인덕턴스에 대한 연구 (A Study on the Leakage Inductance in Current Transformers by 3D Integral Methods)

  • 이희갑;박용필;이성일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.116-118
    • /
    • 2002
  • This paper presents leakage magnetic field and leakage inductance calculations in current transformer by means of 3-D Integral methods. From the distribution diagram of leakage magnetic flux to be analyzed using program called TRACAL 3, it confirms a parallel to the winding axis direction of the leakage flux lines in the air gap between the windings. The leakage inductances $L_{r1}\;and\;L_{r2}$ of the primary and secondary windings were calculated, their values are 4.23 mH and 0.49 mH, respectively. They are also similar to the measured values of the leakage inductances for the experimental verification, 4.06 mH and 0.47 mH.

  • PDF

고자장 MRI에서의 영상 영역에 대한 B1+ 균질성 (B1+ Homogenizaion over Whole Field of View in High Field MRI)

  • 김홍준;손혁우;조영기;유형석
    • 한국전자파학회논문지
    • /
    • 제23권1호
    • /
    • pp.96-100
    • /
    • 2012
  • 정 자장($B_0$)의 세기가 7 T(Tesla) 또는 9.4 T 고자기장 MRI(Magnetic Resonance Imaging) 시스템은 정 자장의 세기가 1.5 T 또는 3 T MRI(Magnetic Resonance Imaging) 시스템에 비하여 인가된 RF(Radio Frequency) 필드의 높은 불균질성을 보여준다. 다채널(multi-channel) RF 코일에서는 인가된 RF 자장($B_1^+$)의 불균질성을 개선시키기 위해서 각각의 코일 소자(element)에 인가되는 전류의 크기와 위상을 독립적으로 조절할 수 있다. 선택된 관심 영역에서의 RF 자장이 균일하도록 RF 코일의 각 요소로 들어가는 최적화된 전류의 크기와 위상 값을 얻기 위해서 iterative 방법과 함께 convex 최적화 방법이 사용된다. 이러한 방법을 입증하기 위하여 9.4 T MRI 시스템에 RF 코일의 공진 주파수가 400 MHz을 가지는 다채널 전송 선로 코일이 인체 두상 모형과 함께 모델링되었으며, 이 코일에 의하여 자장이 얻어진다. 9.4 T MRI 시스템을 위한 시뮬레이션 결과가 자세히 논의된다.

Bi-2223선재의 임계전류 측정기술 비교 (Interlaboratory Comparison of Critical Current Measurements on Ag-sheathed Bi-2223 tapes)

  • Lee, Kyu-Won;Han, Gi-Youl
    • Progress in Superconductivity
    • /
    • 제3권1호
    • /
    • pp.99-103
    • /
    • 2001
  • We have conducted two runs of interlaboratory comparison on Ag-sheathed Bi-2223 tapes to evaluate the level of measurement techniques for the critical current measurement. Two classes of specimens were prepared for parallel and serial routings and sent to four participating laboratories. The critical currents of specimens were measured at 77 K in zero magnetic field. In the first comparison, we used twenty different Bi-2223 tapes as specimens for comparison and participating laboratories measured the specimens using their own instruments and procedures. As a result, the scattering of data on the first comparison showed -3.0% to +l2.2% for the parallel routing and -0.7% to +l5.1% for the serial routing. Major sources of these variations were attributed to different measurement techniques. Thus, the second comparison of measurement was done on the same specimens under specified measurement conditions, particularly in terms of cooling procedure and sweep rate of the test current. The variations for the second comparison were decreased -3.1% to +3.2% far the parallel routing and -1.8% to +7.7% fur the serial routing.

  • PDF

채널부분의 초전도 자속 흐름 트랜지스터 볼텍스 동력학 (Vortex Dynamics of Superconducting Flux Flow Transistor in a Channel)

  • 고석철;강형곤;임성훈;이종화;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.546-549
    • /
    • 2003
  • The principle of the superconducting vortex flow transistor (SVFT) is based on control of the Abrikosov vortex flowing along a channel. The induced voltage is controlled by a bias current and a control current, instead of external magnetic field. The device is composed of parallel weak links with a nearby current control line. We explained the process to get an I-V characteristic equation and described the method to induce the external and internal magnetic field by the Biot-Savarts law in this paper. The equation can be used to predict the I-V curves for fabricated device. From the equation we demonstrated that the current-voltage characteristics were changed with input parameters. I-V characteristics were simulated to analyze a SVFT with multi-channel by a Matlab program.

  • PDF