• Title/Summary/Keyword: Parallel Transfer

Search Result 546, Processing Time 0.025 seconds

Dialysis with ultrafiltration through countercurrently parallel-flow membrane modules

  • Yeh, Ho-Ming;Chen, Chien-Yu
    • Membrane and Water Treatment
    • /
    • v.4 no.3
    • /
    • pp.191-202
    • /
    • 2013
  • The application of ultrafiltration operation to the dialysis in countercurrently parallel-flow rectangular membrane modules was investigated. The assumption of uniform ultrafiltration flux was made for operation with slight concentration polarization and declination of transmembrane pressure. Considerable improvement in mass transfer is achievable if the operation of ultrafiltration is applied, especially for the system with low mass transfer coefficient. The enhancement in separation efficiency is significantly increased with increasing ultrafiltration flux, as well as with increasing the volumetric flow rates. Furthermore, increasing the volumetric flow rate in retentate phase is more beneficial to mass transfer than increasing in dialysate phase.

REDUCTION OF PRESSURE RIPPLES USING A PARALLEL LINE IN HYDRAULIC PIPELINE

  • KIM K. H.;JANG J. S.;JUNG D. S.;KIM H. E.
    • International Journal of Automotive Technology
    • /
    • v.6 no.1
    • /
    • pp.65-70
    • /
    • 2005
  • Pressure ripples, which are inevitably generated by a fluctuation of flow rate caused by a pump mechanism, include noises and vibrations in hydraulic pipeline. These noises and vibration deteriorate the stability and accuracy of hydraulic systems. The accumulator and hydraulic attenuator are normally used to reduce the pressure ripples. In this study, a parallel line is introduced to the hydraulic pipeline for the hydraulic system with a bent-axis piston pump as a method to reduce the pressure ripples. The dynamic characteristics of the hydraulic pipeline with a parallel line are analyzed by a transfer matrix in the frequency domain. The usefulness of the hydraulic pipeline with a parallel line was ascertained by experiment and simulation. The results from the experiment and simulation show that the hydraulic pipeline with a parallel line were effective in reducing the pressure ripples.

Analysis of the Interference between Parallel Socket Connections and Prediction of the Bandwidth (병렬 연결 간의 트래픽 간섭 현상 분석 및 대역폭 예측)

  • Kim Young-Shin;Huh Eui-Nam;Kim Il-Jung;Hwang Jun
    • Journal of Internet Computing and Services
    • /
    • v.7 no.1
    • /
    • pp.131-141
    • /
    • 2006
  • Recently, many researchers have been studied several high performance data transmission techniques such as TCP buffer Tuning, XCP and Parallel Sockets. The Parallel Sockets is an application level library for parallel data transfer, while TCP tuning, XCP and DRS are developed on kernel level. However, parallel socket is not analyzed in detail yet and need more enhancements, In this paper, we verify performance of parallel transfer technique through several experiments and analyze character of traffic interference among socket connections. In order to enhance parallel transfer management mechanism, we predict the number of socket connections to obtain SLA of the network resource and at the same time, affected network bandwidth of existing connections is measured mathematically due to the interference of other parallel transmission. Our analytical scheme predicts very well network bandwidth for applications using the parallel socket only with 8% error.

  • PDF

A PLANE-PARALLEL MODEL OF THE DIFFUSE GALACTIC LIGHT (확산 은하 복사광에 대한 평면 평행 모델)

  • Seon, Kwang-Il
    • Publications of The Korean Astronomical Society
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • A plane-parallel model of the diffuse Galactic light (DGL) is calculated assuming exponential disks of interstellar dust and OB stars, by solving exactly the radiative transfer equation using an iterative method. We perform a radiative transfer calculation for a model with generally accepted scale heights of stellar and dust distribution and compare the results with those of van de Hulst & de Jong for a constant slab model. We also find that the intensity extrapolated to zero dust optical depth has a negative value, against to the usual expectation.

A Message Transfer Scheme for Efficient Message Passing in the Highly Parallel Computer SPAX (고속병렬컴퓨터(SPAX)에서의 효율적인 메시지 전달을 위한 메시지 전송 기법)

  • 모상만;신상석;윤석한;임기욱
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.9
    • /
    • pp.1162-1170
    • /
    • 1995
  • In this paper, we present a message transfer scheme for efficient message passing in the hierarchically structured multiprocessor computer SPAX(Scalable Parallel Architecture computer based on X-bar network). The message transfer scheme provides interface not only with operating system but also with end users. In order to transfer two types of control message and data message efficiently, it supports both of memory-mapped transfer and DMA-based transfer. Dual-port RAMs are used as message buffers, and control and status registers provide efficient programming interface. Interlaced parity scheme is adopted for error control. If any error is detected at receiving node, errored packet is resent by sender according to retry mechanism. In conjunction with retry mechanism, watchdog timers are used to protect infinite waiting and repeated retry. The proposed message transfer scheme can be applied to input/output nodes and communication connection nodes as well as processing nodes in the SPAX.

  • PDF

Mixed convection heat transfer from vertically parallel and misaligned plates (수직 평판의 평행배열과 엇갈린 배열에서 혼합대류 열전달)

  • 김상영;정한식;권순석
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.68-74
    • /
    • 1993
  • The mixed convection heat transfer has been studied numerically for misaligned and parrallel arrays of two flat plates at 100.leg.Re.leg.700, 0.1.leg.B.leg.1.0, 0.2.leg.leg.PHI.$_{R}$.leg.1Gr=10$^{4}$ and Pr=0.71. For misaligned plates and parallel plates, the optimum plate spacings move to the narrow spacing as Reynolds number and .PHI.$_{R}$ increase and can be expressed by the correlation equations at Gr=10$^{4}$. The optimum plate spacings for parallel plates sharply move to the narrow spacing compared with misaligned plates. The maximum mean Nusselt number of parallel plates shows higher value than that of misaligned plates and can be expressed by the correlation equations at Gr=10$^{4}$.EX>.

  • PDF

Heat and Flow Analysis Inside a Parallel-Flow Heat Exchanger (평행류 열교환기 내부의 열유동 해석)

  • Oh, Seok-Jin;Chung, Kil-Yoan;Lee, Kwan-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.781-788
    • /
    • 2003
  • In the present study, the heat and flow characteristics of a parallel-flow heat exchanger are numerically analyzed by using three-dimensional turbulent modeling. Heat transfer rate and pressure drop are evaluated using the concept of the efficiency index by varying the locations, the shapes and angles of inlet/outlet, and the protrusion height of flat tube. It is found that negative angle of the inlet improves the heat transfer rate and pressure drop. Results show that the locations of the inlet and outlet should be toward the right side and the left side to the reference model, respectively, in order to enhance the heat transfer rate and pressure drop. Increasing the height of the lower header causes pressure drop to decrease and yields the good flow characteristics. The lower protrusion height of flat tube shows the improvement of the heat transfer rate and pressure drop. The heat transfer rate is greatly affected by the parameters of outlet side such as the location and angle of the outlet. However, the pressure drop is influenced by the parameters of inlet side such as the location and angle of inlet and the height of the header.

Implementation of High Speed Transfer System for HD Video Files using Parallel TCP (Parallel TCP 를 이용한 고속 HD 영상파일 전송시스템의 구현)

  • Park, Hyoungyill;Song, Byungjun;Lee, Junggyu;Shin, Yongtae
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2013.11a
    • /
    • pp.20-23
    • /
    • 2013
  • Recently for the transfer of large size video file between sites for high-definition craft editing used by broadcasting company the Public Network is used a lot. In the IP Public Network with QoS(Quality-of-Service) not guaranteed, degradation of performance has several causes. In this paper, we have analyzed the causes of low performance to transfer a large size HD video file in long distance, in order to maximize the effectiveness, the high efficiency network could be implemented enabling the highspeed of HD video file using the connection with networks between hosts through packet creation and multi-session of Parallel TCP. We survey the result of high speed transfer system and verify the efficient transfer method using Public IP Network for large HD video file transfer in broadcasting cooperation.

  • PDF

Optimization of Data Acquisition System with Parallel Collection for PET

  • Yoshida, Eiji;Shimizu, Keiji;Murayama, Hideo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.311-313
    • /
    • 2002
  • We are under development of a 3D PET scanner with depth of interaction (DOI) capable of high sensitivity and high resolution. In this scanner, a maximum data transfer rate of coincidence pair's event information is 10 Mcps and one event is a 64-bit data format. This maximum data transfer rate corresponds by 10 times a conventional PET scanner. A data acquisition system, which fulfills the specification of this scanner, is considered for parallel collection with banks including several coincidence units. Data transfer rate is improved by optimizing parameters of a message size, and so on.

  • PDF

Thermodynamic Modeling of Parallel Flow Condenser for Automotive Air Conditioning System (자동차용 평행류 응축기의 열성능 모델링)

  • 김일겸;고재윤;박상록;임장순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.771-779
    • /
    • 2001
  • In this study, a simulation program has been developed to predict the performance of a parallel flow condenser of an air conditioning system for an automobile. The well-known correlations for he heat transfer rates and the pressure drops are included in this model. It is fond that the numerical model can predict the heat transfer rate and the pressure drop accurately. As the condensing pressure increases of fixed air inlet temperature, the heat transfer rate increases and the pressure drop decreases. The effect of he degree of subcooling on the performance of the condenser is greater than that of the degree of super-heating because the ratio of the area occupied by he tow-phase refrigerant the total area is significantly affected by he degree of subcooling rather than the degree of superheating.

  • PDF