• 제목/요약/키워드: Parallel Testing

검색결과 231건 처리시간 0.02초

High Speed Parallel Fault Detection Design for SRAM on Display Panel

  • Jeong, Kyu-Ho;You, Jae-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.806-809
    • /
    • 2007
  • SRAM cell array and peripheral circuits on display panel are designed using LTPS process. To overcome low yield of SOP, high speed parallel fault detection circuitry for memory cells is designed at local I/O lines with minimal overhead for efficient memory cell redundancy replacement. Normal read/write and parallel test read/write are simulated and verified.

  • PDF

MC-MIPOG: A Parallel t-Way Test Generation Strategy for Multicore Systems

  • Younis, Mohammed I.;Zamli, Kamal Z.
    • ETRI Journal
    • /
    • 제32권1호
    • /
    • pp.73-83
    • /
    • 2010
  • Combinatorial testing has been an active research area in recent years. One challenge in this area is dealing with the combinatorial explosion problem, which typically requires a very expensive computational process to find a good test set that covers all the combinations for a given interaction strength (t). Parallelization can be an effective approach to manage this computational cost, that is, by taking advantage of the recent advancement of multicore architectures. In line with such alluring prospects, this paper presents a new deterministic strategy, called multicore modified input parameter order (MC-MIPOG) based on an earlier strategy, input parameter order generalized (IPOG). Unlike its predecessor strategy, MC-MIPOG adopts a novel approach by removing control and data dependency to permit the harnessing of multicore systems. Experiments are undertaken to demonstrate speedup gain and to compare the proposed strategy with other strategies, including IPOG. The overall results demonstrate that MC-MIPOG outperforms most existing strategies (IPOG, IPOF, IPOF2, IPOG-D, ITCH, TConfig, Jenny, and TVG) in terms of test size within acceptable execution time. Unlike most strategies, MC-MIPOG is also capable of supporting high interaction strengths of t > 6.

모바일 클라우드 컴퓨팅 서비스를 위한 위성영상 병렬 정보처리 성능 예비실험 (Preliminary Performance Testing of Geo-spatial Image Parallel Processing in the Mobile Cloud Computing Service)

  • 강상구;이기원;김용승
    • 대한원격탐사학회지
    • /
    • 제28권4호
    • /
    • pp.467-475
    • /
    • 2012
  • 클라우드 컴퓨팅 서비스는 경제성, 확장성, 보안성, 공유성, 접근성 등에서 특장점이 있기 때문에 단순한 사무용 시스템에서 전문적 과학정보처리까지 여러 분야에서 활용되고 있다. 그러나 공간정보 분야, 특히 원격탐사 분야에서는 연구나 기술 개발 단계가 아직 초기 수준이다. 이번 연구에서는 기존 연구에서 구축한 스마트폰 위성영상 정보처리 시스템을 아마존 웹 서비스와 연계된 모바일 클라우드 컴퓨팅 환경으로 이동하고 연산 성능 향상을 위해 병렬처리 프로그래밍 기법을 적용하였다. 앞으로 모바일 클라우드 컴퓨팅 서비스에 대한 산업적 수요와 관련 기술개발 사례가 증가할 것이므로 이 연구에서는 주로 영상처리 기능에 대한 성능 측정 실험을 우선적으로 수행하였다. 모바일 클라우드 컴퓨팅 환경의 운영이나 서비스 방식이 다양한 데, 이번 연구에서 적용된 실험 조건에서는 클라우드 서버가 단일 서버 방식에 비하여 성능이 우수한 것으로 나타났다. 이 연구는 모바일 클라우드를 위성영상정보처리와 연계하기 위한 예비 연구이다.

Parametric Study of Rectangular Coil for Eddy Current Testing of Lamination

  • Wang, Pengfei;Zeng, Zhiwei
    • 비파괴검사학회지
    • /
    • 제36권2호
    • /
    • pp.155-159
    • /
    • 2016
  • Eddy current testing (ECT) is an important nondestructive testing technology for the inspection of flaws in conductive materials. However, this widely used technology is not suitable for inspecting lamination when a conventional pancake coil is used because the eddy current (EC) generated by the pancake coil is parallel to the lamination and will not be perturbed. A new method using a rectangular coil placed vertical to the work piece is proposed for lamination detection. The vertical sections of the rectangular coil induce ECs that are vertical to the lamination and can be perturbed by the lamination. A parametric study of a rectangular coil by finite element analysis was performed in order to examine the capability of generating vertical EC.

Exhaustive 테스트 기법을 사용한 효율적 병렬테스팅 (An Efficient Parallel Testing using The Exhaustive Test Method)

  • 김우완
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제30권3_4호
    • /
    • pp.186-193
    • /
    • 2003
  • 최근 몇 년 동안 디지털 시스템이 복잡성은 아주 빠르게 증가하고 있다. 비록 반도체 제조업자들이 제품에 대한 신뢰성을 높이려고 노력하고 있지만 어느 때에 시스템이 어딘가에서 결함이 발생할 것이라는 것을 알기는 불가능하다. 이렇듯이 회로가 복잡화함에 따라 테스트 생성(test generation)에 대한 잘 정리되어 있고 자동화된 방법이 필요하게 되었다. 하지만 현재 광범위하게 사용하고 있는 방법중 대부분은 한번에 하나씩의 패턴만을 넣어서 처리하는 방식이다. 이는 각각의 결함에 대해서 탐색하는데 많은 시간을 낭비하게 된다. 본 논문에서는 Exhaustive 방법을 사용하는 테스트 패턴 생성 방법 중에서 분할 기법을 적용하여 테스트 패턴을 생성한다. 또한 이 패턴을 이용하여 병렬로 패턴을 삽입함으로써 더욱 빠르게 결함을 발견할 수 있는 방법을 설계 및 구현한다.

Wind loads on solar panels mounted parallel to pitched roofs, and acting on the underlying roof

  • Leitch, C.J.;Ginger, J.D.;Holmes, J.D.
    • Wind and Structures
    • /
    • 제22권3호
    • /
    • pp.307-328
    • /
    • 2016
  • This paper describes an investigation of the net wind loads on solar panels and wind loads on the underlying roof surface for panels mounted parallel to pitched roofs of domestic buildings. Typical solar panel array configurations were studied in a wind tunnel and the aerodynamic shape factors on the panels were put in a form appropriate for the Australian/New Zealand Wind Actions Standard AS/NZS 1170.2:2011. The results can also be used to obtain more refined design data on individual panels within an array. They also suggest values for the aerodynamic shape factors on the roof surface under the panels, based on a gust wind speed at roof height, of ${\pm}0.5$ for wind blowing parallel to the ridge, and ${\pm}0.6$ for wind blowing perpendicular to the ridge. The net loads on solar arrays in the middle portion of the roof are larger than those on the same portion of the roof without any solar panels, thus resulting in increased loads on the underlying roof structure.

Complete collapse test of reinforced concrete columns

  • Abdullah, Abdullah;Takiguchi, Katsuki
    • Structural Engineering and Mechanics
    • /
    • 제12권2호
    • /
    • pp.157-168
    • /
    • 2001
  • In this paper, experimental investigation into the behavior of reinforced concrete (RC) columns tested under large lateral displacement with four different types of loading arrangements is presented. Each loading arrangement has a different system for controlling the consistency of the loading condition. One of the loading arrangements used three units of link mechanism to control the parallelism of the top and bottom stub of column during testing, and the remaining employed eight hydraulic jacks for the same purpose. The loading systems condition used in this investigation were similar to the actual case in a moment-resisting frame where the tested column was displaced in a double curvature. Ten model column specimens, divided into four series were prepared. Two columns were tested monotonically until collapse, and unless failure took place at an earlier stage of loading, the remaining eight columns were tested under cyclic loading. Test results indicated that the proposed system to keep the top and bottom stubs parallel during testing performed well.

절단된 자료가 있는 병렬형 시스템의 단계적 충격수명검사 (The Step Stress Life Testing for the Parallel System with Censored Data)

  • 박희창;이석훈
    • 품질경영학회지
    • /
    • 제23권1호
    • /
    • pp.15-28
    • /
    • 1995
  • We consider a step-stress life testing which is devised for a two-component parallel system with considerably long life time. To describe such a system, we use an exponential distribution as the survival function. The lift distribution is assumed between the log mean life time and the stress with the cumulative exposure model. The criterion for optimality is to minimize the sum of the variances of the maximum likelihood estimators of the mean life times of each part under the normal stress.

  • PDF

Novel Laser Ultrasonic Receiver for Industrial NDE

  • Pouet, B.;Breugnot, S.;Clemenceau, P.
    • 비파괴검사학회지
    • /
    • 제26권6호
    • /
    • pp.380-389
    • /
    • 2006
  • A new laser-based ultrasonic receiver that is based on multi-channel interferometry is shown to be well suited for robust and sensitive detection of ultrasound in industrial environment. The proposed architecture combines random-quadrature detection with detector arrays and parallel multi-speckle processing. The high sensitivity is reached, thanks to the random phase distribution of laser speckle caused by surface roughness. High-density parallel signal processing is achieved by using a simple demodulation technique based on signal rectification. This simple detection scheme is also demonstrated for rejection of the laser intensity noise, making possible the use of lower cost laser without reduction in performances. Results demonstrating this new principle of operation and its performances are presented.

Fatigue Crack Growth Behavior for Welded Joint of X80 Pipeline Steel

  • Kim, Young-Pyo;Kim, Cheol-Man;Kim, Woo-Sik;Shin, Kwang-Seon
    • 비파괴검사학회지
    • /
    • 제29권1호
    • /
    • pp.43-48
    • /
    • 2009
  • The fatigue crack growth behavior of high strength X80 pipeline steel was investigated with compact tension specimens that crack growth directions were aligned either parallel or normal to the rolling direction of the pipeline. Also, the fatigue crack growth rates for welded joint of X80 pipeline steel were investigated with compact tension specimens that crack growth directions were aligned either parallel or normal to the welding line. The experimental results indicated the fatigue crack growth behavior was markedly different in three zones, weld metal, heat affected zone and base metal of welded joints. There was a trend toward increment in the fatigue life of weld metal and heat affected zone as compared with the X80 pipeline steel.