• 제목/요약/키워드: Parallel Resonance

검색결과 232건 처리시간 0.03초

단일 인버터로 두 대의 영구자석 동기전동기 병렬운전에 대한 공진특성해석 (The Resonance Characteristic Analysis for Speed Control of Parallel Connected Dual SPMSMs fed by a Single Inverter)

  • 윤철;권우현
    • 전기학회논문지
    • /
    • 제66권4호
    • /
    • pp.643-650
    • /
    • 2017
  • This pap4er analyzes resonance characteristics of a slave motor that is not controlled by load and parameter differences between Dual motors during parallel operation in middle-low speed. Dual SPMSMs(Surface mounted Permanent Magnet Synchronous Motor) connected in parallel to a single inverter controlled by the master and slave control in this paper. Based on the stability analysis of the SPMSM for a variation of torque angle, the 6th nonlinear state equation of the torque angle variation in the SIMM(Single Inverter Multi Motor) structure is derived according to a mathematical model for the dual motors. In general, an analysis of the 6th order nonlinear state equation is complex. Therefore, a resonance frequency generated from the slave motor is found from the characteristic equation of the 2nd order system obtained by linearization and model reduction near steady state operation point. Through simulations and experiments, it is confirmed that the stability analysis of the SPMSMs and state equation models are useful for the variation of the torque angle analyzed in this paper.

광학시스템을 이용한 메로시아닌 색소 LB막의 표면 모폴로지 해석 (The Surface Analysis of the Merocyanine Dye LB film using Optical system)

  • 강기호;신훈규;장정수;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1714-1716
    • /
    • 2000
  • We fabricated the optical system of merocyanine dye using Langmuir-Blodgett(LB) technique because quite uniform orientation could be obtained, which is one of the most important factors to affect to its optical characteristics. The resonance frequency and other electrical parameters at the parallel resonance state were measured using the impedance analyser(HP 4294 A). Also the morphological changes of dye molecules after UV irradiation were observed using AFM. The parallel resonance frequency and resistance by electrical equivalent circuit were decreased with the UV irradiation and these aspects are different from general mass adsorption process. Therefore the structural changes of dye molecules are being considered, that is, the aggregated molecules become dissociated. It indicates that the shifts of the resonance frequency and the others occurred without mass absorption.

  • PDF

Bragg 반사층을 이용한 IMT-2000 대역통과필터용 체적 탄성파 공진기 (Film Bulk Acoustic Resonator(FBAR) using Bragg Reflector for IMT-2000 Bandpass Filter)

  • 김상희;김종헌;박희대;이시형;이전국
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.377-382
    • /
    • 2000
  • Film bulk acoustic resonator (FBAR) using AIN reactively sputtered at room temperature was fabricated. The FBAR is composed of a piezoelectric aluminium nitride thin film, top electrode of Al and bottom electrode of Au connected by a short (200${\mu}{\textrm}{m}$) transmission line on both sides and reflector layers of SiO$_2$- W Pair. The active areas of Al and Au were patterned using 150${\mu}{\textrm}{m}$ diameter shadow mask. The series resonance frequency (fs) and the parallel resonance frequency (fp) were measured at 1.976 GHz and 2.005 GHz, respectively. The minimum insertion loss and return loss were 6.1 dB and 37.19 dB, and the quality factor (Q) was 4261.

  • PDF

Wireless Power Transfer via Magnetic Resonance Coupling (MRC) with Reduced Standby Power Consumption

  • Lee, Byoung-Hee
    • Journal of Power Electronics
    • /
    • 제19권3호
    • /
    • pp.637-644
    • /
    • 2019
  • Wireless power transfer (WPT) technology with various transfer mechanisms such as inductive coupling, magnetic resonance and capacitive coupling is being widely researched. Until now, power transfer efficiency (PTE) and power transfer capability (PTC) have been the primary concerns for designing and developing WPT systems. Therefore, a lot of studies have been documented to improve PTE and PTC. However, power consumption in the standby mode, also defined as the no-load mode, has been rarely studied. Recently, since the number of WPT products has been gradually increasing, it is necessary to develop techniques for reducing the standby power consumption of WPT systems. This paper investigates the standby power consumption of commercial WPT products. Moreover, a standby power reduction technique for WPT systems via magnetic resonance coupling (MRC) with a parallel resonance type resonator is proposed. To achieve a further standby power reduction, the voltage control of an AC/DC travel adapter is also adopted. The operational principles and characteristics are described and verified with simulation and experimental results. The proposed method greatly reduces the standby power consumption of a WPT system via MRC from 2.03 W to 0.19 W.

계통연계형 인버터 병렬운전 시 LCL 필터 상호간섭 특성 연구 (A Study for Mutual Interference of LCL Filter Under Parallel Operation of Grid-Connected Inverters)

  • 이강;서정진;차한주
    • 전력전자학회논문지
    • /
    • 제26권2호
    • /
    • pp.75-81
    • /
    • 2021
  • This study analyzes the resonance characteristics caused by the mutual interference between LCL filters and the grid impedance under the parallel operation of the grid-connected inverter using the LCL filter. These characteristics are verified through simulation and experiment. Two inverters are used to connect to the grid in parallel, and the system parameters, including the LCL filter, are set to the same conditions. In the case of inverters running in parallel at the point of common coupling, the presence of grid impedance causes mutual interference between the LCL filters of each inverter, and the deviation of the filter resonance frequency is analyzed to understand the parallel inverter. The correlation between the number of devices and the size of grid impedance is simulated by PSIM and verified by MATLAB. By connecting the real-time digital simulator Typhoon HILS to the DSP 28377 control board, the mutual interference characteristics are tested under the condition of two inverters running in parallel. The experimental and analysis results are the same, indicating the validity of the analysis.

A Resonant Characteristics Analysis and Suppression Strategy for Multiple Parallel Grid-connected Inverters with LCL Filter

  • Sun, Jian-jun;Hu, Wei;Zhou, Hui;Jiang, Yi-ming;Zha, Xiao-ming
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1483-1493
    • /
    • 2016
  • Multiple parallel inverters have multiple resonant frequencies that are influenced by many factors. This often results in stability and power quality problems. This paper develops a multiple input multiple output model of grid-connected inverter systems using a closed-loop transfer function. The influence factors of the resonant characteristics are analyzed with the developed model. The analysis results show that the resonant frequency is closely related to the number, type and composition ratio of the parallel inverters. To suppress resonance, a scheme based on virtual impedance is presented, where the virtual impedance is emulated in the vicinity of the resonance frequency. The proposed scheme needs one inverter with virtual impedance control, which reduces the design complexity of the other inverter controllers. Simulation and experimental tests are carried out on two single phase converter-based setups. The results validate the correctness of the model, the analytical results and the resonant suppressing scheme.

고조파 전류원에 의한 콘덴서 임피던스 특성 해석 (Analysis of Impedance Performance for Condenser by Harmonic Current Source)

  • 김종겸;박영진
    • 조명전기설비학회논문지
    • /
    • 제25권4호
    • /
    • pp.57-64
    • /
    • 2011
  • Most of the user has been used linear load and non-linear load. The former is usually inductive load which is needed power factor compensation, the latter is power conversion system device. Actually two kinds of load is used together in the customer application. Generally capacitor is used for power-factor compensation of inductive load and reduction harmonics of non linear load with reactor. Non-linear load generates harmonic current for its energy conversion process. If harmonic current pass along the low impedance side of distribution system, the magnification of voltage and current is appeared by the series and parallel resonance. As a result, condenser has received a bitter electrical stress by the harmonic component. In this paper, we analyzed that how resonance is changed by the 5-th harmonic current pattern and proposed an alternative plan for non-magnification.

Advanced Methods in Dynamic Contrast Enhanced Arterial Phase Imaging of the Liver

  • Kim, Yoon-Chul
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권1호
    • /
    • pp.1-16
    • /
    • 2019
  • Dynamic contrast enhanced (DCE) magnetic resonance (MR) imaging plays an important role in non-invasive detection and characterization of primary and metastatic lesions in the liver. Recently, efforts have been made to improve spatial and temporal resolution of DCE liver MRI for arterial phase imaging. Review of recent publications related to arterial phase imaging of the liver indicates that there exist primarily two approaches: breath-hold and free-breathing. For breath-hold imaging, acquiring multiple arterial phase images in a breath-hold is the preferred approach over conventional single-phase imaging. For free-breathing imaging, a combination of three-dimensional (3D) stack-of-stars golden-angle sampling and compressed sensing parallel imaging reconstruction is one of emerging techniques. Self-gating can be used to decrease respiratory motion artifact. This article introduces recent MRI technologies relevant to hepatic arterial phase imaging, including differential subsampling with Cartesian ordering (DISCO), golden-angle radial sparse parallel (GRASP), and X-D GRASP. This article also describes techniques related to dynamic 3D image reconstruction of the liver from golden-angle stack-of-stars data.

Analysis on the cascade high power piezoelectric ultrasonic transducers

  • Lin, Shuyu;Xu, Jie
    • Smart Structures and Systems
    • /
    • 제21권2호
    • /
    • pp.151-161
    • /
    • 2018
  • A new type of cascade sandwiched piezoelectric ultrasonic transducer is presented and studied. The cascade transducer is composed of two traditional longitudinally sandwiched piezoelectric transducers, which are connected together in series mechanically and in parallel electrically. Based on the analytical method, the electromechanical equivalent circuit of the cascade transducer is derived and the resonance/anti-resonance frequency equations are obtained. The impedance characteristics and the vibrational modes of the transducer are analyzed. By means of numerical method, the dependency of the resonance/anti-resonance frequency and the effective electromechanical coupling coefficient on the geometrical dimensions of the cascade transducer are studied and some interesting conclusions are obtained. Two prototypes of the cascade transducers are designed and made; the resonance/anti-resonance frequency is measured. It is shown that the analytical resonance/anti-resonance frequencies are in good agreement with the experimental results. It is expected that this kind of cascade transducer can be used in large power and high intensity ultrasonic applications, such as ultrasonic liquid processing, ultrasonic metal machining and ultrasonic welding and soldering.

자기 공명 무선 전력 전송 시스템에서 공진 코일의 배열에 관한 연구 (Study on Arrangement of Self-Resonant Coils in Wireless Power Transfer System Based on Magnetic Resonance)

  • 김진욱;지현호;최연규;윤영현;김관호;박영진
    • 한국전자파학회논문지
    • /
    • 제21권6호
    • /
    • pp.564-572
    • /
    • 2010
  • 본 논문에서는 자기 공명 방식의 무선 전력 전송 시스템에서 공진 코일의 배열에 따른 특성을 제시한다. 공진 코일에는 헬리컬 구조를 사용하였다. 공진 코일을 설계하기 위해 헬리컬 코일의 인덕턴스와 커패시턴스를 구하였다. 유한 요소법을 이용하여 설계된 공진 코일을 시뮬레이션 하였고, 송수전 공진 코일 간의 다양한 배열에 대한 특성을 해석하였다. 검증을 위하여 시제품을 제작하였고, 수직 및 평행 배열일 때의 효율을 측정하였다. 측정 결과, 평행 배열일 때는 50 %의 전달 효율을 얻을 수 있는 구간이 코일 지름의 2배 이내였고, 수직 배열일때는 코일 지름의 1.5배 이내였다. 제작한 시제품은 평행 배열된 송수전 공진 코일이 40 cm 간격일 때 최대 84.25 %의 효율을 보였다.