• 제목/요약/키워드: Parallel Module

검색결과 400건 처리시간 0.022초

SiC 전력반도체의 병렬 구동 시 전류 불균형을 최소화하는 Mezzanine 구조의 방열일체형 스위칭 모듈 개발 (Development of Switching Power Module with Integrated Heat Sink and with Mezzanine Structure that Minimizes Current Imbalance of Parallel SiC Power Semiconductors)

  • 이정호;민성수;이기영;김래영
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.39-47
    • /
    • 2023
  • This paper applies a structural technique with uniform parallel switch characteristics in gates and power loops to minimize the ringing and current imbalance that occurs when a general discrete package (TO-247)-based power semiconductor device is operated in parallel. Also, this propose a heat sink integrated switching module with heat sink design flexibility and high power density. The developed heat dissipation-integrated switching module verifies the symmetry of the parasitic inductance of the parallel switch through Q3D by ansys and the validity of the structural technique of the parallel switch using the LLC resonant converter experiment operating at a rated capacity of 7.5 kW.

정보통신용 다병렬 운전의 모듈식 무정전전원장치 (Module UPS of multi-parallel operation for use in information & telecommunication systems)

  • 구태근;류지수;배상규;박근갑
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2007년도 학술대회
    • /
    • pp.390-393
    • /
    • 2007
  • The reliability as well as the power capability of the UPS system can be increased by replacing a single UPS unit with multiple small UPS units in parallel, resulting in a so-called module UPS. This module UPS system allows that a new module can be added or replaced while maintaining power to loads, which is a hot-swappable operation. In addition, it has desirable features such as ease of output power expandability, convenience of maintenance and repair, and high reliability. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. 5kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the module UPS system has a high power factor, a low distortion of output voltage and input current, hot-swappable operations and good load sharing characteristics.

  • PDF

고전압 소스를 위한 모듈식 병렬운전 알고리즘 (Module Type Parallel Driving Algorithm for High Voltage Direct-Current source)

  • 우병국;이용화;강찬호;조관열
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.24-27
    • /
    • 2008
  • For high voltage DC-DC converters, the parallel operation of several high voltage source modules is necessary to reduce the material cost. In the conventional parallel operation with HDC module control unit, it is difficult to repair the HDC system for the failure of control unit. To overcome these problems, new parallel operating algorithm for high voltage DC-DC converter is presented. The proposed algorithm has no main control unit and each module can be selected as the master according to the operating conditions. Therefore, one of modules can be replaced as the master immediately when the previous master module is failed. In addition, the extension of extra modules can be simple.

  • PDF

병렬형 3자유도 구형 모듈의 해석과 힘반영 원격조종기로의 구현 (Analysis of a Parallel 3 Degree-of-Freedom Spherical Module and its Implementation as a Force Reflecting Manual Controller)

  • 김희국;이병주
    • 대한기계학회논문집
    • /
    • 제18권10호
    • /
    • pp.2501-2513
    • /
    • 1994
  • In this paper, a compact, light-weight, universal, spherical 3-degree-of-freedom, parallel-structured manual controller with high reflecting-force capability is implemented. First, the position analysis, kinematic modeling and analysis, force reflecting transformation, and applied force control schemes for a parallel structured 3 degree-of-freedom spherical system have been described. Then, a brief description of the system integration, its actual implementation hardware, and its preliminary analysis results are presented. The implemented parallel 3 degree-of-freedom spherical module is equipped with high gear-ratio reducers, and the friction due to the reducers is minimized by employing a force control algorithm, which results in a "power steering" effect for enhanced smoothness and transparency (for compactness and reduced weight).d weight).

정위치 해석해를 가지는 병렬 메카니즘에 관한 분석과 혼합구조 매니퓰레이터로의 활용 (Analysis of Parallel Mechanisms with Forward Position Closed-Form Solution with Application to Hybrid Manipulator)

  • 김희국;이병주
    • 제어로봇시스템학회논문지
    • /
    • 제5권3호
    • /
    • pp.324-337
    • /
    • 1999
  • In this work, a new 3-PSP type spatial 3-degree-of-freedom parallel mechanism is proposed. And a 6 DOF hybrid manipulator which consists of a 3-PPR type planar 3 DOF parallel mechanism and a new 3-PSP type spatial 3-degree-of-freedom parallel mechanism is proposed. Both 3 DOF mechanism modules have closed-form forward position solutions and particularly, 3-PSP spatial module has unique forward position solution. Firstly, the closed-form position analysis and first-order kinematic analysis for the proposed 3-PSP type module are carried out, and the first-order kinematic characteristics are examined via maximum singular value and the isotropic index of the mechanism. It is shown through these analyses that the mechanism has excellent isotrpic property throughout the workspace. Secondly, position and kinematic analysis of the 3-PPR planar module are briefly described. Thirdly, the forward position analysis for the 3-PPR 3-PSP type 6 degree-of-freedom hybrid mechanism consisting of a 3-PPR planar module and a 3-PSP spatial module is performed along with the analysis of the workspace size and first-order kinematic characteristics. The kinematic characteristics of the proposed hybrid manipulator are compared to those of geometrically similar Stewart manipulator.

  • PDF

Design of Parallel Processor for Image Processing

  • 노석환;박종원
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.743-744
    • /
    • 2006
  • This paper presents implementation of parallel processing system for image processing. The parallel processing system proposed consisted of 16 processing elements, and multi-access memory system, and interface modules. The multi-access memory system we introduced is made up of a memory module selection, a data routing module, and an address calculation and routing module.

  • PDF

영상처리를 위한 Pipelined 병렬처리 시스템 (Pipelined Parallel Processing System for Image Processing)

  • 이형;김종배;최성혁;박종원
    • 전기전자학회논문지
    • /
    • 제4권2호
    • /
    • pp.212-224
    • /
    • 2000
  • 본 논문에서는 영상 응용프로그램의 처리 속도를 향상하기 위한 병렬처리 시스템을 제안한다. 병렬처리 시스템은 Pipelined SIMD 구조를 갖고 있으며, 다수개의 처리기와 다중접근 기억장치로 구성된다. 다중접근 기억장치는 메모리 모듈들과 메모리 제어부로 구성되며, 메모리 제어부는 메모리 모듈 선택 모듈, 데이터 라우팅 모듈, 그리고 주소 계산 및 라우팅 모듈로 구성되어 있으며, 블록, 행, 그리고 열 내의 데이터를 동시에 접근할 수 있는 기능을 제공한다. 제안한 병렬처리 시스템을 검증하기 위해서 형태학적 필터를 적용하여 기능 검증 및 처리속도를 확인하였다.

  • PDF

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Choi Y.K.;Ko T.G.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.987-993
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Furthermore, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristic.

  • PDF

태양전지 모듈의 파라미터 추정에 관한 연구 (A Study on the Parameter Estimation of Solar Cell Module)

  • 김태엽;이윤규;안호균
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권2호
    • /
    • pp.92-98
    • /
    • 2002
  • It is necessary to measure the solar cell parameter fur understanding characteristic of solar cell and applying to many other fields. Since photovoltaic system consists of solar cell module, which are connected each other in series and parallel, it is not proper to apply a solar cell parameter to photovoltaic system. Therefore, to estimate the solar tell module and to solve the problem of the established algorithm is on demand. In this paper the authors have improved the accuracy of solar cell module Parameter estimation by compensating series and Parallel resistance, and developed a new parameter estimation algorithm, which can be applied to photovoltaic system without high cost measuring equipment. And the validity of proposed algorithm is verified by the simulation and experimentation.

태양광 발전시스템의 그림자 영향을 고려한 PV 모듈의 재구성 (Reconfiguration of PV Module Considering the Shadow Influence of Photovoltaic System)

  • 고재섭;정동화
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.36-44
    • /
    • 2013
  • This paper proposes the reconfiguration of PV module considering shadow influence of photovoltaic system. The PV system is consisted series-parallel connection of PV module. The voltage and current between PV modules become unbalance when shadow occurs to PV module. If shadow occurs to the series connection PV module, the output current is limited to current of shaded PV module. Also if shadow occurs to the parallel connection PV module, the output voltage is limited to voltage of shaded PV module. These problems are caused power loss. Therefore, the PV module in this paper consist using the fixed module and variable module by shaded conditions. The reconfiguration of PV module can compensates the shadow influence by changing connection of a variable module when shadow is occurred to PV module. A validity of the reconfiguration of PV module proposed in this paper proves through comparing with performance of conventional PV module.