• Title/Summary/Keyword: Parallel Efficiency

Search Result 1,048, Processing Time 0.03 seconds

Noncompliance screw supported maxillary molar distalization in a parallel manner (미니스크류를 이용한 상악구치부 후방이동장치 효과)

  • Nalcaci, Ruhi;Bicakci, Ali Altug;Ozan, Fatih
    • The korean journal of orthodontics
    • /
    • v.40 no.4
    • /
    • pp.250-259
    • /
    • 2010
  • Objective: Intraoral noncompliance upper molar distalization techniques have gained in popularity and have subsequently found to be successful in Class II correction. The aim of the present study was to introduce a screw supported intraoral distalization appliance and investigate its efficiency. Methods: Twenty-one subjects (11 females, 10 males; average age of 14.9 years) with Angle Class II malocclusion participated in this study. Two screws were inserted behind the incisive foramen and immediately loaded to distalize the upper first molars. An intraoral screw supported distalization appliance was used to distalize the upper molars in order to achieve a Class I molar relationship. Skeletal and dental changes were evaluated using cephalometric and three-dimensional (3D) model analysis. Results: Upper molars were distalized 3.95 mm on average and a Class I molar relationship was achieved without any anchorage loss. The upper molars were tipped only $1.49^{\circ}$ and the upper right and left molars were rotated only $0.54^{\circ}$ and $0.74^{\circ}$ respectively which were statistically non-significant (p > 0.05). Conclusions: The newly designed screw supported noncompliance distalization appliance was found to be an effective device for achieving bodily molar distalization without any anchorage loss.

A study on the excavation cycle by the drill-and-blast method for a room-and-pillar underground structure (주방식 지하구조물의 발파 굴착공정 분석 연구)

  • Lee, Chul-Ho;Hyun, Young-Hwan;Hwang, Je-Don;Choi, Soon-Wook;Kang, Tae-Ho;Chang, Soo-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.6
    • /
    • pp.511-524
    • /
    • 2016
  • Since a room-and-pillar underground structure is characterized by its grid-type array of room and pillar, its economical efficiency can be governed by excavation sequence. In this study, the construction period by the drill-and-blast method as a excavation method for a room-and-pillar underground structure was examined. In addition, the parallel excavation sequence was considered as the main sequence of a room-and-pillar underground structure. Sequences of mucking and support installation were derived to estimate the total excavation cycle by taking the case of a road tunnel into consideration. From the excavation cycle of room-and-pillar underground structure, the relationship between available maximum and minimum numbers of jumbo drill machines depending on the number of faces in operation was suggested.

Complexity-based Sample Adaptive Offset Parallelism (복잡도 기반 적응적 샘플 오프셋 병렬화)

  • Ryu, Eun-Kyung;Jo, Hyun-Ho;Seo, Jung-Han;Sim, Dong-Gyu;Kim, Doo-Hyun;Song, Joon-Ho
    • Journal of Broadcast Engineering
    • /
    • v.17 no.3
    • /
    • pp.503-518
    • /
    • 2012
  • In this paper, we propose a complexity-based parallelization method of the sample adaptive offset (SAO) algorithm which is one of HEVC in-loop filters. The SAO algorithm can be regarded as region-based process and the regions are obtained and represented with a quad-tree scheme. A offset to minimize a reconstruction error is sent for each partitioned region. The SAO of the HEVC can be parallelized in data-level. However, because the sizes and complexities of the SAO regions are not regular, workload imbalance occurs with multi-core platform. In this paper, we propose a LCU-based SAO algorithm and a complexity prediction algorithm for each LCU. With the proposed complexity-based LCU processing, we found that the proposed algorithm is faster than the sequential implementation by a factor of 2.38 times. In addition, the proposed algorithm is faster than regular parallel implementation SAO by 21%.

Identification of Internal Resistance of Microbial Fuel Cell by Electrochemical Technique and Its Effect on Voltage Change and Organic Matter Reduction Associated with Power Management System (전기화학적 기법에 의한 미생물연료전지 내부저항 특성 파악 및 전력관리시스템 연계 전압 변화와 유기물 저감에 미치는 영향)

  • Jang, Jae Kyung;Park, Hyemin;Kim, Taeyoung;Yang, Yoonseok;Yeo, Jeongjin;Kang, Sukwon;Paek, Yee;Kwon, Jin Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.5
    • /
    • pp.220-228
    • /
    • 2018
  • The internal resistance of microbial fuel cell (MFC) using stainless steel skein for oxidizing electrode was investigated and the factors affecting the voltage generation were identified. We also investigated the effect of power management system (PMS) on the usability for MFC and the removal efficiency of organic pollutants. The performance of a stack microbial fuel cell connected with (PMS) or PMS+LED was analyzed by the voltage generation and organic matter reduction. The maximum power density of the unit cells was found to be $5.82W/m^3$ at $200{\Omega}$. The maximum current density was $47.53A/m^3$ without power overshoot even under $1{\Omega}$. The ohmic resistance ($R_s$) and the charge transfer resistance ($R_{ct}$) of the oxidation electrode using stainless steel skein electrode, were $0.56{\Omega}$ and $0.02{\Omega}$, respectively. However, the sum of internal resistance for reduction electrode using graphite felts loaded Pt/C catalyst was $6.64{\Omega}$. Also, in order to understand the internal resistance, the current interruption method was used by changing the external resistance as $50{\Omega}$, $300{\Omega}$, $5k{\Omega}$. It has been shown that the ohm resistance ($R_s$) decreased with the external resistance. In the case of a series-connected microbial fuel cell, the reversal phenomenon occurred even though two cells having the similar performance. However, the output of the PMS constantly remained for 20 hours even when voltage reversal occurred. Also the removal ability of organic pollutants (SCOD) was not reduced. As a result of this study, it was found that buffering effect for a certain period of time when the voltage reversal occurred during the operation of the microbial fuel cell did not have a serious effect on the energy loss or the operation of the microbial fuel cell.

Effect of Inorganic Coagulants on the Performance of Electro-Chemical Treatment Process Treating Hospital Wastewater (병원폐수의 전기화학적 처리시 무기응집제 주입 효과에 관한 연구)

  • Jeong, Seung-Hyun;Jeong, Byung-Gon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.709-716
    • /
    • 2011
  • Effect of inorganic coagulants dosing on the performance of electro-chemical process was studied when treating hospital wastewater having low electrolyte concentration. It is thought that adding inorganic coagulants caused increase in concentration of electrolyte and this caused increase in free chloride concentration and consequently, caused increase in indirect oxidation effect. Thus, COD removal efficiencies more than doubled in percentage terms at the 2 hrs of reaction time and current density of $1.76A/dm^2$ compared with the results obtained from the parallel experiments without adding inorganic coagulants. T-N removal efficiencies approximately doubled in percentage terms at the 2 hrs of reaction time and 700 ppm of coagulants addition and applied current density of $1.76A/dm^2$ due to the increase of free residual chlorine such as HOCl caused by increase of electrolyte concentration through the addition of inorganic coagulants. Under the same experimental condition, more than 90% of T-P removal efficiencies was obtained. The reason can be explained that increase of chemical adsorption rate between phosphate and insoluble metal compounds caused by dissolved oxygen generated from anode by the increased electrolyte concentration through inorganic coagulants addition make a major role in improving T-P removal efficiencies. It can be concluded that inorganic coagulants addition as the supplemental agent of electrolyte is effective way in improving organic and nutrient salt removal efficiency when treating hospital wastewater having low electrolyte concentration.

Hand Gesture Recognition Algorithm Robust to Complex Image (복잡한 영상에 강인한 손동작 인식 방법)

  • Park, Sang-Yun;Lee, Eung-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.7
    • /
    • pp.1000-1015
    • /
    • 2010
  • In this paper, we propose a novel algorithm for hand gesture recognition. The hand detection method is based on human skin color, and we use the boundary energy information to locate the hand region accurately, then the moment method will be employed to locate the hand palm center. Hand gesture recognition can be separated into 2 step: firstly, the hand posture recognition: we employ the parallel NNs to deal with problem of hand posture recognition, pattern of a hand posture can be extracted by utilize the fitting ellipses method, which separates the detected hand region by 12 ellipses and calculates the white pixels rate in ellipse line. the pattern will be input to the NNs with 12 input nodes, the NNs contains 4 output nodes, each output node out a value within 0~1, the posture is then represented by composed of the 4 output codes. Secondly, the hand gesture tracking and recognition: we employed the Kalman filter to predict the position information of gesture to create the position sequence, distance relationship between positions will be used to confirm the gesture. The simulation have been performed on Windows XP to evaluate the efficiency of the algorithm, for recognizing the hand posture, we used 300 training images to train the recognizing machine and used 200 images to test the machine, the correct number is up to 194. And for testing the hand tracking recognition part, we make 1200 times gesture (each gesture 400 times), the total correct number is 1002 times. These results shows that the proposed gesture recognition algorithm can achieve an endurable job for detecting the hand and its' gesture.

Fabrication and analysis of $1.3\mum$ spot-size-converter integrated laser diodes (광모드변환기가 집적된 $1.3\mum$ SC-FP-LD 제작 및 특성 해석)

  • 심종인
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.271-278
    • /
    • 2000
  • We have fabricated and analyzed the lasing characteristics of 1.3$\mu\textrm{m}$ Spot-Size-Converter (SSC) integrated Fabry-Perot (FP) laser diodes, which are very promising light sources for optical subscriber networks. SSC-LDs has been developed by BIB (buttjoint-built-in) coupling and selective MOVPE growth. High-performances were achieved such as the slope efficiency from the SSC facet of 0.23-0.32 mW/mA, the full-width at the half maximum of the far-field pattern (FFP) of 9.5$^{\circ}$~12.3$^{\circ}$, the alignment tolerances of $\pm$2.3$\mu\textrm{m}$ and $\pm$2.5$\mu\textrm{m}$ within the extra-coupling loss of 1 dB for the vertical and parallel directions, respectively. These experimental results were compared to theoretical ones in order to clarify the operational problems and give a good design direction of the fabricated SSC-LDs. It was revealed that an asymmetric output power from the facets, an irrelevancy of FFP and the waveguide structure around SSC facet region, and a poor temperature characteristics were originated from the scattering in the BIB and SSC sections and SHB effect in the active section for the first time.t time.

  • PDF

Finite-element investigation of the center of resistance of the maxillary dentition (상악 치아군의 저항중심의 위치에 관한 3차원 유한요소 해석)

  • Jeong, Gwang-Mo;Sung, Sang-Jin;Lee, Kee-Joon;Chun, Youn-Sic;Mo, Sung-Seo
    • The korean journal of orthodontics
    • /
    • v.39 no.2
    • /
    • pp.83-94
    • /
    • 2009
  • Objective: The aim of this study was to investigate the 3-dimensional position of the center of resistance of the 4 maxillary anterior teeth, 6 maxillary anterior teeth, and the full maxillary dentition using 3-dimensional finite element analysis. Methods: Finite element models included the whole upper dentition, periodontal ligament, and alveolar bone. The crowns of the teeth in each group were fixed with buccal and lingual arch wires and lingual splint wires to minimize individual tooth movement and to evenly disperse the forces to the teeth. A force of 100 g or 200 g was applied to the wire beam extended from the incisal edge of the upper central incisor, and displacement of teeth was evaluated. The center of resistance was defined as the point where the applied force induced parallel movement. Results: The results of study showed that the center of resistance of the 4 maxillary anterior teeth group, the 6 maxillary anterior teeth group, and the full maxillary dentition group were at 13.5 mm apical and 12.0 mm posterior, 13.5 mm apical and 14.0 mm posterior, and 11.0 mm apical and 26.5 mm posterior to the incisal edge of the upper central incisor, respectively. Conclusions: It is thought that the results from this finite element models will improve the efficiency of orthodontic treatment.

Adaptive Pipeline Architecture for an Asynchronous Embedded Processor (비동기식 임베디드 프로세서를 위한 적응형 파이프라인 구조)

  • Lee, Seung-Sook;Lee, Je-Hoon;Lim, Young-Il;Cho, Kyoung-Rok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.1
    • /
    • pp.51-58
    • /
    • 2007
  • This paper presented an adaptive pipeline architecture for a high-performance and low-power asynchronous processor. The proposed pipeline architecture employed a stage-skipping and a stage-combining scheme. The stage-skipping scheme can skip the operation of a bubble stage that is not used pipeline stage in an instruction execution. In the stage-combining scheme, two consecutive stages can be joined to form one stage if the latter stage is empty. The proposed pipeline architecture could reduce the processing time and power consumption. The proposed architecture supports multi-processing in the EX stage that executes parallel 4 instructions. We designed an asynchronous microprocessor to estimate the efficiency of the proposed pipeline architecture that was synthesized to a gate level design using a $0.35-{\mu}m$ CMOS standard cell library. We evaluated the performance of the target processor using SPEC2000 benchmark programs. The proposed architecture showed about 2.3 times higher speed than the asynchronous counterpart, AMULET3i. As a result, the proposed pipeline schemes and architecture can be used for asynchronous high-speed processor design

Design of Binary Constant Envelope System using the Pre-Coding Scheme in the Multi-User CDMA Communication System (다중 사용자 CDMA 통신 시스템에서 프리코딩 기법을 사용한 2진 정진폭 시스템 설계)

  • 김상우;유흥균;정순기;이상태
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.5
    • /
    • pp.486-492
    • /
    • 2004
  • In this paper, we newly propose the binary CA-CDMA(constant amplitude CDMA) system using pre-coding method to solve the high PAPR problem caused by multi-user signal transmission in the CDMA system. 4-user CA-CDMA, the basis of proposed binary CA-CDMA system, makes binary output signal for 4 input users. It produces the output of binary(${\pm}$2) amplitude by using a parity signal resulting from the XOR operation of 4 users data. Another sub-channel or more bandwidth is not necessary because it is transmitted together with user data and can be easily recovered in the receiver. The extension of the number of users can be possible by the simple repetition of the basic binary 4-user CA-CDMA. For example, binary 16-user CA-CDMA is made easily by allocating the four 4-user CA-CDMA systems in parallel and leading the four outputs to the fifth 4-user CA-CDMA system as input, because the output signal of each 4-user CA-CDMA is also binary. By the same extension procedure, binary 64 and 256-user CA-CDMA systems can be made with the constant amplitude. As a result, the code rate of this proposed CA-CDMA system is just 1 and binary CA-CDMA does not change the transmission rate with the constant output signal(PAPR = 0 ㏈). Therefore, the power efficiency of the HPA can be maximized without the nonlinear distortion. From the simulation results, it is verified that the conventional CDMA system has multi-level output signal, but the proposed binary CA-CDMA system always produces binary output. And it is also found that the BER of conventional CDMA system is increased by nonlinear HPA, but the BER of proposed binary CA-CDMA system is not changed.