• 제목/요약/키워드: Paper-based electrochemical sensor

검색결과 25건 처리시간 0.02초

자발 구동형 종이 펌프를 이용한 종이 전기화학 센서 (Paper-based Electrochemical Sensor Using a Self-operated Paper Pump)

  • ;김치관;;김용신
    • 센서학회지
    • /
    • 제33권3호
    • /
    • pp.158-164
    • /
    • 2024
  • We developed a self-operated paper pump that can maintain a nearly constant flow rate of an aqueous solution along a paper strip channel in paper-based analytical devices (PADs). The quasi-stationary flow rate was controlled by increasing the crosssectional channel area (capillary force) using a fan-shaped absorption pad coupled with a paper strip channel. The flow rate is regulated by varying the fan angle of the circular absorbing pad. Furthermore, the flow rate can be increased by furnishing a hollow cavity at the center of a conventional paper strip channel. The rate was regulated by varying the length of the hollow paper channel in the flow rate range of 5.1-26.4 mm/min. As a preliminary work, a paper-pump-coupled PAD was fabricated, and its CV detection capability was evaluated for the redox reaction of Fe(CN)6+4/+3. The combination of a paper pump with a PAD resulted in an ideal CV curve with a higher limiting current and faster response time. These results are interpreted well by the Levich equation, which suggests that the paper pump is a very useful component in paper-based sensors.

전계효과트랜지스터(FET) 바이오센서 실험 셋업 분석을 통한 동작원리 이해 (Understanding of the Working Principle of Field-effect Transistor (FET) Biosensor with the Review Of Experimental Measurement Set-up)

  • 이국녕
    • 센서학회지
    • /
    • 제32권6호
    • /
    • pp.487-495
    • /
    • 2023
  • Over the past few decades, considerable research has been conducted on field-effect transistor (FET) biosensors; however, other than electrochemical sensors for pH, they have not reached the commercialization stage and still remain at the basic research level. Although several reports have been published on experiments with real biological samples, no reports exist of developments that have reached commercialization or finalized approval for use. In this paper, we explain the reason for the experiments of FET biosensors to induce spurious signals in an experimental setup and explain the existence of misunderstandings regarding the operating principle of FET biosensors owing to the spurious signals. Based on the thoughtful review of the results of previously published papers, we show that the electrochemical read-out principle of FET biosensors requires our intensive understanding of the interfacial potential between the solution and the sensor electrode for further progress in the FET biosensor research.

종이 기반 전기화학 센서의 연구 동향 (A Review on Paper-based Electrochemical Sensors)

  • 서민지
    • 전기화학회지
    • /
    • 제27권1호
    • /
    • pp.1-7
    • /
    • 2024
  • 신체에 부착하는 웨어러블(wearable) 센서 및 현장 진단 검사(point-of-care testing)가 용이한 센서의 필요성이 부각되면서, 종이를 기반으로 하는 센서들이 활발히 연구되어왔다. 종이는 매우 저렴하면서도 가볍고 유연할 뿐만 아니라, 표면에 카본과 같은 전도성 물질 및 왁스와 같은 소수성 물질을 입히기 쉽다. 또한, 종이를 이루는 셀룰로오스 섬유에 의한 모세관 현상으로 외부 힘 없이 용액의 흐름을 유도할 수 있어 웨어러블 전기화학 센서의 플랫폼으로 특히 주목받고 있다. 이에 따라, 다양한 분석 물질들을 전기화학적인 방법으로 검출하는 종이 기반 센서들이 활발히 개발되어 왔다. 특히, 분석 물질에 따른 전류 값 이외에도, 전기화학 발광현상(electrochemiluminescence) 혹은 전기 변색 물질(electrochromic material)을 도입하여 시각적으로 데이터를 나타내는 센서들도 보고되어 왔다. 이 논문에서는 종이 기반 전기화학 센서들의 제작법 및 다양한 활용 전략을 사례 중심으로 소개하였다.

초정밀 스프레이 방법을 이용한 단일벽 탄소나노튜브 pH센서 개발 (Development of single walled-carbon nanotubes based pH sensor using ultra-precision spray method)

  • 권재홍;이경수;이윤희;주병권
    • 센서학회지
    • /
    • 제15권2호
    • /
    • pp.127-133
    • /
    • 2006
  • Recent studies demonstrated the ability of carbon nanotube (CNT) to promote electron transfer reactions of important compounds and to impart higher stability onto electrochemical sensors. CNT-based sensors measured by hydroxyl radical concentration or pH value suggest great promise for biosensors. This paper describes a new method for fabricating a very simple and inexpensive pH sensor compose of single walled-carbon nanotubes (SW-CNTs) using an ultra-precision spray. CNT-based sensor shows pH sensitivity in buffer solution at different pH range. Our experimental results show the sensor responses to pH buffer solution and the conductance of depends on the pH values. These results support application possibility of SW-CNTs based pH sensor for mass production.

Graphene Based Electrochemical DNA Biosensor for Detection of False Smut of Rice (Ustilaginoidea virens)

  • Rana, Kritika;Mittal, Jagjiwan;Narang, Jagriti;Mishra, Annu;Pudake, Ramesh Namdeo
    • The Plant Pathology Journal
    • /
    • 제37권3호
    • /
    • pp.291-298
    • /
    • 2021
  • False smut caused by Ustilaginoidea virens is an important rice fungal disease that significantly decreases its production. In the recent past, conventional methods have been developed for its detection that is time-consuming and need high-cost equipments. The research and development in nanotechnology have made it possible to assemble efficient recognition interfaces in biosensors. In this study, we present a simple, sensitive, and selective oxidized graphene-based geno-biosensor for the detection of rice false smut. The biosensor has been developed using a probe DNA as a biological recognition element on paper electrodes, and oxidized graphene to enhance the limit of detection and sensitivity of the sensor. Probe single-stranded DNA (ssDNA) and target ssDNA hybridization on the interface surface has been quantitatively measured with the electrochemical analysis tools namely, cyclic voltammetry, and linear sweep voltammetry. To confirm the selectivity of the device, probe hybridization with non-complementary ssDNA target has been studied. In our study, the developed sensor was able to detect up to 10 fM of target ssDNA. The paper electrodes were employed to produce an effective and cost-effective platform for the immobilization of the DNA and can be extended to design low-cost biosensors for the detection of the other plant pathogens.

Nano composite System based on ZnO-functionalized Graphene Oxide Nanosheets for Determination of Cabergoline

  • Beitollahi, Hadi;Tajik, Somayeh;Alizadeh, Reza
    • Journal of Electrochemical Science and Technology
    • /
    • 제8권4호
    • /
    • pp.307-313
    • /
    • 2017
  • In this paper we report an electrochemical sensor based on ZnO-functionalized graphene oxide nanocomposite (ZnO-GO) for the sensitive determination of the cabergoline. Cabergoline electrochemical behaviors were investigated by cyclic voltammetry (CV), chronoamperometry (CHA) and differential pulse voltammetry (DPV). The modified electrode shows electrocatalytic activity toward cabergoline oxidation in phosphate buffer solution (PBS) (pH 7.0) with a reduction of the overpotential of about 180 mV and an increase in peak current. The DPV data showed that the obtained anodic peak currents were linearly dependent on the cabergoline concentrations in the range of $1.0-200.0{\mu}M$, with the detection limit of $0.45{\mu}M$. The prepared electrode was successfully applied for the determination of cabergoline in real samples.

Use of High-Temperature Gas-Tight Electrochemical

  • Park, Jong-Hee;Beihai Ma;Park, Eun-Tae
    • The Korean Journal of Ceramics
    • /
    • 제4권2호
    • /
    • pp.103-113
    • /
    • 1998
  • By using a gas-tight electrochemical cell, we can perform high-temperature coulometric titration and measure electronic transport properties to determine the elecronic defect structure of metal oxides. This technique reduces the time and expense required for conventional thermogravimetric measurements. The components of the gas-tight coulometric titration cell are an oxygen sensor, Pt/yttria stabilitized zirconia(YSZ)/Pt, and an encapsulated metal oxide sample. Based on cell design, both transport and thermodynamic measurements can be performed over a wide range of oxygen partial pressure ($pO_2=10^{-35}$ to 1 atm). This paper describes the high-temperature gas-tight electrochemical cells used to determine electronic defect structures and transport properties for pure and doped-oxide systems, such as YSZ, doped and pure ceria $(Ca-CeO_2 \;and\; CeO_2)$, copper oxides and copper-oxide-based ceramic superconductors, transition metal oxides, $SrFeCo_{0.5}O_x,\; and \;BaTiO_2$.

  • PDF

나노 센서를 이용한 구조물 건전성 감시 기법 (Structural Heal th Monitoring Based On Carbon Nanotube Composite Sensors)

  • 강인필;이종원;최연선
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.613-619
    • /
    • 2006
  • This paper introduces a new structural health monitoring using a nano sensor. The sensor is made of nano smart composite material based on carbon nanotubes. The nano sensor is fabricated as a thin and narrow polymer film sensor that is bonded or deposited onto a structure. The electrochemical impedance and dynamic strain response of the neuron change due to deterioration of the structure where the sensor is located. A network of the long nano sensorcan form a structural neural system to provide large area coverage and an assurance of the operational health of a structure without the need for actuators and complex wave propagation analyses that are used with other methods.

  • PDF

실내환경 모니터링시스템을 위한 무선 센서네트워크에서의 플러딩 방식의 질의모델 설계 및 구현 (Design and implementation of flooding-based query model in wireless sensor networks for indoor environmental monitoring system)

  • 이승철;정상중;이영동;정완영
    • 센서학회지
    • /
    • 제17권3호
    • /
    • pp.168-177
    • /
    • 2008
  • An indoor environmental monitoring system using IEEE 802.15.4 based wireless sensor network is proposed to monitor the amount of pollutant entering to the room from outside and also the amount of pollutant that is generated in indoor by the building materials itself or human activities. Small-size, low-power wireless sensor node and low power electrochemical sensor board is designed to measure the condition of indoor environment in buildings such as home, offices, commercial premises and schools. In this paper, two query models, the broadcasting query protocol and flooding query protocol, were designed and programmed as a query-based routing protocol in wireless sensor network for an environment monitoring system. The flooding query routing protocol in environment monitoring is very effective as a power saving routing protocol and reliable data transmission between sensor nodes.

조기화재 감시시스템을 위한 CO센서의 시그널컨디셔너 성능개선 (Performance Improvement of CO Sensor Signal Conditioner for Early Fire Detection System)

  • 박종찬;손진근
    • 전기학회논문지P
    • /
    • 제66권2호
    • /
    • pp.82-87
    • /
    • 2017
  • This paper presents performance improvement of CO gas sensor signal conditioner for early fire warning system. The warning system is based on the CO sensor and its advanced signal conditioning modules network that employ electochemical gas sensor. The electochemical has advantage of having a linear output and operating with a low consumption and fast response. This electrochemical gas sensor contains a gas membrane and three electrodes(working, counter, reference electrode) in contact with an electrolyte. To use a three-electrode sensor, a voltage has to be applied between the working and the reference electrode according to the specification of the sensor. In this paper, we designed these requirements that should be considered in temperature compensation algorithm and electrode measurement of CO sensor modules by using advanced signal conditioning method included 3-electrode. Simulation and experimental results show that signal conditioner of CO sensor module using 3-electrode have a advantage linearity, sensitivity and stability, fast response etc..