• 제목/요약/키워드: Paldang

검색결과 324건 처리시간 0.026초

팔당호 수질의 연직분포에 대한 밀도류 영향 평가 (Evaluating Effect of Density Flow from Upstream on Vertical Distribution of Water Quality at the Paldang Reservoir)

  • 공동수
    • 한국물환경학회지
    • /
    • 제35권6호
    • /
    • pp.557-566
    • /
    • 2019
  • Paldang is a river reservoir in the Midwest of Korea, which is a drinking water source for the metropolitan area. Since the Paldang Reservoir is shallow, and has a short hydraulic residence time, its water quality is directly impacted by two incoming rivers, the north Han River (NHR) and the south Han River (SHR). The NHR has different seasonal patterns of water temperature from the SHR because the NHR is greatly impacted by the discharge water from upstream dams. The electrical conductivity (EC) and other material concentrations of the SHR are usually higher than those of the NHR because its basin is limestone-based. The difference in water temperature in the two rivers causes density flow, and the distribution of the EC within the reservoir can be an indicator for monitoring density flow. From the vertical gradient of the EC at the dam site, from spring to fall, it was confirmed that the SHR flowed into the upper layer, and the NHR flowed into the lower layer, and vice versa at other times. The relative difference (RD) of the EC between the upper layer and the lower layer at the dam site was used as an indicator for density flow. The RD of the EC showed a very significant correlation with the RD of total organic carbon (r = 0.70, p < 0.001) and the RD of total nitrogen (r = 0.58, p < 0.01). This relationship is based on the assumption that the difference in electrical conductivity and water quality between the SHR and the NHR is constant. However, in many cases this assumption is inconsistent. Thus, further study is needed on more suitable indicators to evaluate the impact of density flow on water quality.

팔당호 방류량과 조류발생요인들의 상관성 (Correlation between Paldang Reservoir Discharge and Causes of Algal Blooming)

  • 유호식;이병희;이승희
    • 유기물자원화
    • /
    • 제21권3호
    • /
    • pp.93-98
    • /
    • 2013
  • 본 연구에서는 최근 자주 거론되는 녹조발생의 주요 원인을 찾아보고자 하였다. 지난 십년이상의 기상자료 및 수질에 대한 실측자료를 이용하여 녹조원인에 대한 통계적 접근을 시도하였다. 팔당호를 대상으로 한 연구에서 조류예보일수에 일정한 추세를 발견할 수는 없지만 발생년도에는 10일 이상씩 나타나는 특징을 보여 주고 있으며 최근 5년간은 발령일수가 증가하고 있어 주의해야 할 것으로 판단되었다. 유속의 자료 대신 사용된 방류량을 보면 조사기간 중 세 배 정도의 차이가 나는 해도 관찰되었다. 클로로필a에 대한 다른 지표들의 상관계수를 보면 뚜렷한 한 가지 지표로 나타나지 않아서 상관계수 0.4를 넘는 요인은 없었다. 그 중 중요한 요인으로 나타나는 것은 일조시간, BOD, 그리고 방류량이며 일조시간과 BOD는 양의 상관 그리고 강수량과 방류량은 음의 상관을 나타내고 있어서 광합성미생물에 의한 현상으로서 타당한 결과로 보였다. 수온과 총인농도는 중요한 요인이 될 것으로 예상되었으나 결과는 낮은 상관성을 보였다. 이상의 결과로 판단할 때 조류발생에는 여러 가지 요인이 복합적으로 작용하며 그중 일조시간, BOD, 그리고 유속 또는 방류량은 중요한 요인으로 판단된다. 방류량과 다른 요소와의 상관관계도 조사하였다. 강수량과 수온이 양의 상관을 보이는 것은 계절적인 효과로 타당해 보였다.

팔당산 호밀(Secale cereale) B 염색체의 출현빈도에 대하여 (Frequency of B-chromosomes in Rye (Secale cereale) Cultivated in Paldang)

  • 이웅직
    • Journal of Plant Biology
    • /
    • 제24권4호
    • /
    • pp.181-190
    • /
    • 1981
  • 1963년부터 1977년까지 팔당산 호밀의 B 염색체의 출현빈도를 조사한 결과는 다음과 같다. 2%(1963), 8%(1964), 8%(1965), 15%(1966), 11.5%(1968), 11.7%(1969), 20%(1975), 19.6%(1976), 12.8%(1977). $x^2$검정의 결과는 각 년도에 있어서의 B'의 출현빈도 사이에 유의차가 없음을 나타내고 있다. 1976년과 1977년에는 호밀 밭을 10개 구로 나누어 재료를 수집하여 B'의 분포와 표본채취의 결과를 분석하였다. 호밀의 B'는 집단내에서 비교적 균일하게 분포되고 있으며 최소 50개체를 관찰하면 호밀 집단의 B'의 출현빈도를 대략 알 수가 있었다. 팔당산 호밀 집단에서 1966년부터 1977년까지 계속하여 전좌이형접합체(T.H)에 의한 사가염색체를 가진 개체가 1~7%의 빈도로 관찰되었다.

  • PDF

시추공 물리탐사를 이용한 동탄성계수와 암상과의 상관성 분석 (Relationship between Dynamic Elastic Modulus and Lithology using Borehole Prospecting)

  • 박충화;송무영;박종오
    • 한국지구과학회지
    • /
    • 제23권6호
    • /
    • pp.507-513
    • /
    • 2002
  • 유성일대 화강암, 팔당일대 호상 편마암 및 사북일대 퇴적암 지역에서 동탄성계수와 탄성파 속도와의 관계를 밝히기 위하여 완전파형음파검층을 통해 이들 암상에서 탄성파 P파와 S파 속도를 측정하였다. 또한 유성일대 화강암과 팔당일대 편마암 지역에 대해서는 일축압축강도와 포아송비를 실내시험에서 측정하였다. 실내실험 자료에서는 팔당 호상편마암 지역의 탄성파 P파 및 S파 속도가 유성의 화강암 지역보다 높게 나타난 반면, 포아송비가 낮은 값을 보이므로 포아송비의 증가함에 따라 탄성파 P파 및 S파 속도가 감소하는 상관관계를 보였다. 완전파형음파검층을 통하여 얻어진 동탄성계수는 동체적탄성계수와 동전단탄성계수에 비하여 높은 값을 보인다.

고빈도 수온 자료를 이용한 팔당호의 성층과 흐름 변화 분석 (Analyzing Flow Variation and Stratification of Paldang Reservoir Using High-frequency W ater Temperature Data)

  • 류인구;이보미;조용철;최황정;신동석;김상훈;유순주
    • 한국물환경학회지
    • /
    • 제36권5호
    • /
    • pp.392-404
    • /
    • 2020
  • The focus of this study was to quantify the thermal stratification and analyze the relationship between the stratification structure and the tributaries to understand flow variations in the Paldang Reservoir. The vertical distribution of the temperature and density gradients, and the depth and thickness of the thermocline were quantitatively calculated using a lake physics tool (rLakeAnalyzer) and high-frequency monitoring data. Based on a density gradient of 0.2 kg/㎥/m, the thermocline was formed from mid-May to early-September 2019 and the other periods were weakly stratified or mixed. The thickness of the thermocline was developed until 4.7 m and the depth of the thermocline was formed at a depth of 3 - 6 m at the front of the Paldang Reservoir. During the formation of the thermocline, the Namhangang and Gyeongancheon tributaries with relatively high water temperature (low-density) flowed into the upper layer of the reservoir, and the Bukhangang tributary with low water temperature (high-density) mainly affected the lower layer of the reservoir. This is because the density currents were formed due to the difference in the water temperature of the tributaries. The findings of this study may be used for constructing high-frequency monitoring and quantitative data analyses of reservoirs.

방류량 및 하류부유황을 고려한 팔당댐의 수문조작기준 선정 (Gate Operation Rule of Paldang Dam by Considering Discharge and Downstream Flow Pattern)

  • 서규우;이종설
    • 물과 미래
    • /
    • 제29권2호
    • /
    • pp.209-219
    • /
    • 1996
  • 1973년 팔당 수력발전소 준공 이래로 사용하여 온 수문조작기준은, 1985년 충주 다목적댐 건설에 따른 한강홍수예경보 프로그램 개선에 따라 일부 수정을 거쳐 사용하고 있다. 그 동안 한강 종합개발 사업의 하도정비사업결과로 팔당댐 하류지역의 수면저하가 가시적으로 발생하게 되었다. 이로 인해 댐 건설당시의 낙차에 변화가 생겼고 댐하류부의 수위가 평균 3m 정도 저하되어 잠수 오리피스식 여수로인 팔당댐의 방류량 산정식에 문제점이 발생하면서 수문개방방식별 방류량의 재산정이 불가피해졌다. 본 연구에서는, 이러한 문제점을 해결하고 수문조작기준을 결정하기 위하여 수리모형실험을 통해 세가지 수문조작 방식을 비교, 검토하였다. 댐우안에 위치한 발전소 설비 및 운영에 영향을 미치지 않는 안전범위를 최우선으로 하여 방류량별, 개도형태별로 하류부에서의 유황을 관찰하였으며, 또한 수치모형으로도 하류부유황을 모의하여 검토한 결과, 좌측 수문 5개씩을 순차적으로 개방하는 방식을 가장 적절한 수문조작기준으로 결정하였다.

  • PDF

강우기 및 평수기의 팔당호 유기물 수지산정 (Organic Carbon Budget during Rainy and Dry Period in Paldang Reservoir)

  • 이유희;정동일;박혜경
    • 생태와환경
    • /
    • 제37권3호통권108호
    • /
    • pp.272-281
    • /
    • 2004
  • 팔당호의 유기물 수지 산정을 위해 팔당호내 일차생산력을 측정하고 유입하천의 유입유기물량 및 방류유기물량을 측정하여 유기물부하에서 내부생성유기물의 기여도를 평가하였다. 식물플랑크톤에 의한 일차생산력은 지점과 시기에 따라 큰 차이를 보여 3회 조사결과 $101{\sim}2701\;mgC\;m^{-2}day{-1}$의 범위로 나타났으며, 체류시간이 길고, 수체내 클로로필 a농도가 높았던 6월에 모든 지점에서 높은 생산력을 보였다. 빈번한 강우로 체류시간이 짧고 조류현존량이 적었던 4월과 8월의 조사에서는 총 유기물유입량에서 내부생성유기물량은 약 7%를 차지하였고 이중 식물플랑크톤에 의한 내부생산기여도는 약 5%로 매우 낮았다. 그러나 조사일 전후로 강우가 없어 수체가 안정되었고 외부유입유기물량이 적었던 6월 조사에서는 식물플랑크톤에 의한 내부생산 기여도가 29.0%를 보였다.

팔당호의 수리 및 수온 조사를 통한 물순환특성 분석 (Analysis of Water Circulation Characteristics for Hydraulic and Water Temperature Investigation in Paldang Reservoir)

  • 최황정;조용철;유순주;송용식;류인구
    • Ecology and Resilient Infrastructure
    • /
    • 제6권1호
    • /
    • pp.12-22
    • /
    • 2019
  • 본 연구에서는 팔당호 내 주요지점에서 수심별 연속 수리 및 수온 조사를 수행하여 팔당호의 시공간적 물순환 특성을 파악하고자 하였다. 이포보와 청평댐에서의 수온 및 방류 패턴의 차이로 인하여 팔당호 내 북한강 및 남한강 구간에서의 흐름 및 수온 변동특성이 상이하게 나타났다. 수직혼합기에는 북한강과 남한강 구간의 전 층에서 하류방향 흐름이 우세하게 나타났다. 성층형성기에 이포보 방류수의 수온이 청평댐 방류수의 수온보다 높았으며, 이로 인해 북한강 하류 구간에서 표층은 상대적으로 고온수가 위치하여 상류방향 흐름으로 배수 현상이 나타나고 수렴대가 형성되었다. 남한강 하류 구간은 중층과 저층에서 저온수가 분포하여 상류방향 흐름이 나타나고 표층과 혼합되기 어려운 이층류 구조를 나타내었다.

팔당 상수원 보호구역내 도로비점오염의 특성 및 저감시설의 적용성 연구 (Characteristics of Roadside Non-point Pollution and Applicability of Reduction Facilities in Paldang Water Source Protection Zone)

  • 조혜진;송미영
    • Ecology and Resilient Infrastructure
    • /
    • 제7권4호
    • /
    • pp.294-299
    • /
    • 2020
  • 본 연구에서는 팔당 상수원 보호구역내 적정 도로비점오염 저감시설의 계획을 위해 대상 도로구간의 현장조사를 통해서 보호구역내 도로의 특성을 파악하고 이에 적용가능한 도로를 선정하고 시설을 시범적용하여 그 유효성을 검증하였다. 팔당 상수원 보호구역은 도로주변 토양의 배수등급이 높아 침투시설을 지양하고 도로사면을 통한 자연적인 오염원 저감방법을 적용하는 것이 적정하다. 앞으로 도로비점저감시설의 계획 및 설계에서 대상도로의 특성에 대한 분석 후 저감계획을 세우는 것이 적정하며 이는 관련 규정 및 설계 기준에도 반영되어야 할 것이다.

수도권 팔당취수장 원수 이용 온도차에너지 부존량 조사 (Evaluation of Water Temperature Difference Energy of the Raw Water from Paldang Water Intake Station)

  • 조용;박진훈;김영준;박태진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.170.2-170.2
    • /
    • 2010
  • The amount of the heating and cooling energy of water source heat pump using the raw water from the Paldang water intake station is investigated in the study. The Han river water is conveyed in the large-size shallowly buried pipe. Averaged water temperature at the position, 27 km from the Paldang water intake station, is increased by $1.11^{\circ}C$ due to the geothermal energy transfer under the ground, therefore the raw water has more thermal energy than the river water. To estimate of the thermal energy for the raw water, it is assumed that the water source heat pump is used for the heating and cooling ventilation. When $5.0^{\circ}C$ temperature difference energy of the raw water is used in the heat pump system all the year except for the January and February in which $3.0^{\circ}C$ temperature difference energy is used. It is predicted that total 5,766.3 Tcal could be used in the metropolitan area a year, which is about 3.0% of the river water unutilized energy resources.

  • PDF