• Title/Summary/Keyword: Paired T-test

Search Result 2,837, Processing Time 0.032 seconds

Field Comparison of Korean Diffusive Sampler and Charcoal Tube Methods for Determination of Organic Vapors (공기중 유기용제 농도 측정에 있어서 국산 확산포집기와 활성탄관의 비교연구)

  • Cho, Sook Ja;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.1
    • /
    • pp.33-48
    • /
    • 1997
  • Korean diffusive sampler (KDS) and charcoal tube (CT) were used for sampling n-hexane, trichloroethylene and toluene in air KDS was made by Department of Environmental Health, SNU-SPH in 1995. Surveys were conducted at ten industrial plants with organic solvents. The relationship between two sampling methods was examined by linear regression analysis, and concentrations by two sampling methods were compared using paired t-test. The results are as follows: 1. The geometric means by CT and KDS methods were 3.26ppm and 3.32ppm for n-hexane, 5.07ppm and 6.34ppm for toluene, and 7.18ppm and 7.90ppm for toluene, respectively. There was no significant difference between results by CT and KDS methods in three organic vapors (p>0.05). When linear regression analysis was performed, two sampling methods were highly related ; correlation coefficients were 0.98, 0.90 and 0.96 for n-hexane, toluene and trichloroethylene, respectively. 2. Airborne concentrations of n-hexane (n=21) were below 0.5 TLV level. The GM by two methods were almost same (3.09 ppm). And there was no significant difference between results by two methods (p>0.05). 3. Since toluene and trichloroethylene concentrations showed several levels, appropriate sampling rates were applied for each level. The GM of toluene concentrations by two methods at 0.5 TLV level were 3.75ppm and 5.48ppm. The KDS method overestimated the toluene concentrations at 0.5 TLV level (p<0.05). The GM values of toluene concentrations at 1 TLV level were 31.80ppm and 25.38ppm and at 2 TLV level were 64.13 ppm and 51.37 ppm. The KDS method underestimated concentration at both level (p<0.05). For trichloroethylene, the GM at 0.5 TLV level were 4.97 ppm and 7.11ppm. The KDS method overestimated the concentration of trichloroethylene (p<0.05). In conclusion, concentrations of three organic vapors measured by CT and KDS were not significantly different and results by two methods were highly related. But at contain concentrations, the levels by method were significantly different. Therefore, it is suggested that sampling rate of KDS should be studied simultaneously using CT method for organic vapors.

  • PDF

The Effects of Simulated Mild Leg Length Discrepancy on Gait Parameters and Trunk Acceleration

  • Jung, Soo-jung;An, Duk-hyun;Shin, Sun-shil
    • Physical Therapy Korea
    • /
    • v.25 no.4
    • /
    • pp.9-18
    • /
    • 2018
  • Background: Leg length discrepancy (LLD) leads to many musculoskeletal disorders and affects daily activities such as walking. In the majority of the population, mild LLD is a common condition. Nevertheless, it is still controversy among researchers and clinicians on the effects of mild LLD during gait, and available studies have largely overlooked this issue. Objects: The purpose of the present study is to investigate the effects of mild LLD on the gait parameters and trunk acceleration. Methods: A total of 15 female and male participants with no evidence of LLD of >.5 ㎝ participated in the present study. All participants walked under the following two conditions: (1) The non-LLD condition, where the participants walked in shoes of the same heel height; (2) A mild LLD condition induced by wearing a 1.5 ㎝ higher heel on the right shoe. The GAITRite system and tri-axial accelerometer were used to measure gait parameters and trunk acceleration. To compare the variation of each variable, a paired t-test was performed. Results: Compared to the non-LLD condition, step time and swing phase were significantly increased in the mild LLD condition, while stance phase, single support phase, and double support phase significantly decreased in the short limb (p<.05). In the long limb of the mild LLD condition, single support phase significantly increased, while swing phase significantly decreased (p<.05). Furthermore, significant decrease in the gait velocity and cadence in the mild LLD condition were observed (p<.05). In the comparison between both limbs in the mild LLD condition, the step time and swing phase of the short limb significantly increased compared with the long limb, while step length, stance phase, and single support phase of the long limb significantly increased compared with the short limb (p<.05). Additionally, trunk acceleration of all directions (anterior-posterior, medial-lateral, vertical) significantly increased in the mild LLD condition (p<.05). Conclusion: The results of the present study demonstrate that mild LLD causes altered and asymmetrical gait patterns and affects the trunk, resulting in inefficient gait. Therefore, mild LLD should not be overlooked and requires adequate treatment.

Randomized clinical trial on the efficacy of Escherichia coli-derived rhBMP-2 with ${\beta}$-TCP/HA in extraction socket

  • Huh, Jung-Bo;Lee, Hyo-Jung;Jang, Ji-Woong;Kim, Myung-Jin;Yun, Pil-Young;Kim, Su-Hong;Choi, Kyung-Hee;Kim, Young-Kyun;Cho, Kyoo-Sung;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.3
    • /
    • pp.161-165
    • /
    • 2011
  • PURPOSE. This randomized clinical trial was conducted to assess the safety and effectiveness of the ErhBMP-2 in alveolar bone regeneration as well as preservation of the ${\beta}$-TCP bone graft material that contains ErhBMP-2. MATERIALS AND METHODS. This study involved 72 patients at the 3 study centers. The patients, who were divided into 2 groups: the experiment group who had ErhBMP-2 coated TCP/HA and the control group who had TCP/HA graft material alone transplanted immediately after tooth extraction. CT was taken before and 3 months after the transplantation and healing status was compared between the two groups. The efficacy endpoints that were used to measure the degree of bone induction included alveolar bone height and 3 measurements of bone width. The paired t test was used to determine the significance of the changes (P<.05). RESULTS. Changes in alveolar bone height were $-1.087{\pm}1.413$ mm in the control group and $-.059{\pm}0.960$ mm in the experimental group (P<.01). At 25% extraction socket length [ESL], the changes were $0.006{\pm}1.149$ mm in the control group and $1.279{\pm}1.387$ mm in the experimental group. At 50% ESL, the changes were $0.542{\pm}1.157$ mm and $1.239{\pm}1.249$ mm, respectively (P<.01 for 25% ESL, and P<.05 for 50% ESL). During the experiment, no adverse reactions to the graft material were observed. CONCLUSION. ErhBMP-2 coated ${\beta}$-TCP/HA were found to be more effective in preserving alveolar bone than conventional ${\beta}$-TCP/HA alloplastic bone graft materials.

Clinical Apply of Dual Energy CT (kVp switching) : A Novel Approach for MAR(Metal Artifact Reduction) Method (듀얼에너지 CT(kvp switching)의 임상 적용: MAR(Metal Artifact Reduction) 알고리즘의 적용)

  • Kim, Myeong-Seong;Jeong, Jong-Seong;Kim, Myeong-Goo
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.79-85
    • /
    • 2011
  • OThe purpose of this article was to measure and compare the value of the metal artifact reduction (MAR) algorithm by Dual energy(kVp switching) CT (Computed Tomography) for non using MAR and we introduced new variable Dual energy CT applications through a clinical scan. The used equipment was GE Discovery 750HD with Dual-Energy system(kVp switching). CT scan was performed on the neck and abdomen area subject for patients. Studies were from Dec 20 2010 to Feb 10 2011 and included 25 subject patients with prosthesis. We were measured the HU (Hounsfield Unit) and noise value at metal artifact appear(focal loss of signal and white streak artifact area) according to the using MAR algorithm. Statistical analyses were performed using the paired sample t-test. In patient subject case, the statistical difference of showing HU was p=0.01 and p=0.04 respectively. At maximum black hole artifact area and white streak artifact area according to the using MAR algorithm. However noise was p=0.05 and p=0.04 respectively; and not the affected black hole and white streak artifact area. Dual Energy CT with the MAR algorithm technique is useful reduce metal artifacts and could improve the diagnostic value in the diagnostic image evaluation of metallic implants area.

Dosimetric Validation of the Acuros XB Advanced Dose Calculation Algorithm for Volumetric Modulated Arc Therapy Plans

  • Park, So-Yeon;Park, Jong Min;Choi, Chang Heon;Chun, Minsoo;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.180-188
    • /
    • 2016
  • Acuros XB advanced dose calculation algorithm (AXB, Varian Medical Systems, Palo Alto, CA) has been released recently and provided the advantages of speed and accuracy for dose calculation. For clinical use, it is important to investigate the dosimetric performance of AXB compared to the calculation algorithm of the previous version, Anisotropic Analytical Algorithm (AAA, Varian Medical Systems, Palo Alto, CA). Ten volumetric modulated arc therapy (VMAT) plans for each of the following cases were included: head and neck (H&N), prostate, spine, and lung. The spine and lung cases were treated with stereotactic body radiation therapy (SBRT) technique. For all cases, the dose distributions were calculated using AAA and two dose reporting modes in AXB (dose-to-water, $AXB_w$, and dose-to-medium, $AXB_m$) with same plan parameters. For dosimetric evaluation, the dose-volumetric parameters were calculated for each planning target volume (PTV) and interested normal organs. The differences between AAA and AXB were statistically calculated with paired t-test. As a general trend, $AXB_w$ and $AXB_m$ showed dose underestimation as compared with AAA, which did not exceed within -3.5% and -4.5%, respectively. The maximum dose of PTV calculated by $AXB_w$ and $AXB_m$ was tended to be overestimated with the relative dose difference ranged from 1.6% to 4.6% for all cases. The absolute mean values of the relative dose differences were $1.1{\pm}1.2%$ and $2.0{\pm}1.2%$ when comparing between AAA and $AXB_w$, and AAA and $AXB_m$, respectively. For almost dose-volumetric parameters of PTV, the relative dose differences are statistically significant while there are no statistical significance for normal tissues. Both $AXB_w$ and $AXB_m$ was tended to underestimate dose for PTV and normal tissues compared to AAA. For analyzing two dose reporting modes in AXB, the dose distribution calculated by $AXB_w$ was similar to those of AAA when comparing the dose distributions between AAA and $AXB_m$.

Comparative Assessment of Corporate Philanthropy by the IPA Method: Service and Manufacturing Industries (IPA기법을 활용한 기업의 사회공헌활동 비교 평가: 서비스업 및 제조업을 중심으로)

  • Ko, Jeong-Yong;Park, Hyeon-Suk
    • Journal of Distribution Science
    • /
    • v.13 no.4
    • /
    • pp.89-98
    • /
    • 2015
  • Purpose - In today's globalized and modern business environment, corporate social responsibility (CSR) activities are considered to be essential for the sustainable development of enterprises. In addition, the corporate philanthropy that is related to CSR practices, as well as their being capable of reducing the anti-corporate sentiment of people have facilitated a qualitative forward leap into the quantitative growth phase. This study aims to undertake a comparative evaluation of corporate philanthropy through the Importance-Performance Analysis (IPA) method focusing on service and manufacturing industries, and to eventually determine a differentiated approach that is needed for corporate philanthropy. Research design, data, and methodology - The survey responses were collected through online research on specialized companies from consumers nationwide who were aged from 20 to 60 and who are aware of corporate philanthropy. A total of 408 sheets of questionnaire survey were used. Frequency analysis was undertaken in this study. The interviewees had demographic characteristics of gender: 206 males (50.5%) and 202 females (49.5%). They also had demographic characteristics of age: 82 people were over 20 (20.1%), 96 over 30 (23.5%), 105 over 40 (25.7%), and 125 over 50 (30.7%) years of age. The distribution of interviewees' residences is as follows: 154 persons (37.7%) in the Special City, 102 persons (25.0%) in the Metropolitan City, and 152 persons (37.3%) in the Provincial Region. The interviewees have been working for the following companies: 34 persons (8.3%) in LG Display, 80 (19.6%) in KT&G, 49 (12.0%) in Amore Pacific, 42 (10.3%) in KIA Motors, 47 (11.5%) in SBS, 52 (12.8%) in Shinhan Bank, 86 (21.1%) in Asiana Airlines, and 18 (4.4%) in Hyundai Department Store. We applied the paired t-test for the IPA analysis. PASW Statistics 18 was used for statistical analysis. Results - The results of IPA analysis indicated that the importance and performance degrees in both manufacturing and service industries were significantly different. Major empirical results showed that, in consumer, social, economic, philanthropic, and environmental dimensions, in the sub-factors of philanthropy activities in both manufacturing and service industries, the importance degree was found to be higher than performance degree. Further, the average difference between importance degree and performance degree by the sub-factors of philanthropy activities. On the other hand, the average difference of environmental dimension was found to be highest in both service and manufacturing industries. Thus, while consumers consider the philanthropy activities of the environmental dimension as most important, actual companies treat performance of philanthropy activities of the environmental dimension insufficiently or negligibly to some degree. Conclusions - The differentiated approach method that is required for corporate philanthropy may be proposed to uplift corporate accomplishments by analyzing the IPA of the attributes of the sub-factors of corporate philanthropy. This is, to an extent, insufficient in the existing studies related to the use of the IPA technique, and it shows the items that are to be conducted intensively.

Development and effect of Simulation-based Educational Program for Communication to Prevent Patients from Safety Accident by Nurses working in the Public Medical Institutions (공공의료기관 간호사의 환자안전사고 대처를 위한 시뮬레이션 기반 의사소통 교육프로그램 개발 및 효과)

  • Mok, Seung Hyun;Kim, Sung Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.115-126
    • /
    • 2020
  • This study focused on the development of a simulation-based educational program for communication, targeted to prevent safety accidents of patients. Application of the program to nurses working in public medical institutions was assessed to identify the effects of the program in terms of communication skill, self-efficacy, critical thinking disposition, and problem solving ability of nurses, before and after completion of the education. Method: A total of 32 nurses, working in hospitals designated as public medical institutions, were selected as subject participants in the present study. Data were collected during the period August 19 to 20, 2019, and analyzed by SPSS 23.0. Results: Results obtained from the present study reveals significant efficacy of the educational program, in respect of improved communication skill, self-efficacy, and problem-solving ability. On completion of the educational program, we observed an increase in the critical thinking disposition of nurses, although it was statistically insignificant. Conclusions: We believe that the educational program developed in the present study can be exploited as a foundation for developing other programs intending to improve the communication skill of nurses employed in clinics of public medical institutions, targeted to prevent occurrence of safety accidents of patients.

Spect-guidance to Reduce Radioactive Dose to Functioning Lung for Stage III Non-small Cell Lung Cancer

  • Wang, Zhong-Tang;Wei, Li-Li;Ding, Xiu-Ping;Sun, Ming-Ping;Sun, Hong-Fu;Li, Bao-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.2
    • /
    • pp.1061-1065
    • /
    • 2013
  • Objective: To investigate the treatment effect of additional information obtained by single photon emission computed tomography (SPECT) lung perfusion imaging (LPI) in the radiotherapy planning process for patients with stage III non-small cell lung cancer (NSCLC). Methods: 39 patients with stage III NSCLC were enrolled. Gross tumor volume (GTV) was outlined by SPECT/CT images, SPECT-LPIs being used to define functional lung (FL) and non-functional lung (NFL) regions. Two sets of IMRT plans were designed to deliver 64Gy to PTV. One was a regular IMRT plan using CT images only (Plan 1), and the other was a corresponding IMRT plan using co-registered images (Plan 2). $FL_{Vx}$ (the % volume of functional lung receiving ${\geq}$x Gy) and $WL_{Vx}$ (% volume of whole lung to receive ${\geq}$x Gy) were compared by paired Student's t test. Kendalls correlation was used to analyze the factor (s) related with the FLV20 decrease. Results: Compared with plan 1, both $WL_{Vx}$ and $FL_{Vx}$ were decreased in plan 2. $WL_{V10}$, $WL_{V15}$, $WL_{V20}$, $WL_{V25}$, $WL_{V30}$ and $WL_{V35}$ decreased 9.7%, 13.8%, 17.2%, 12.9%, 9.8% and 9.8%, and $FL_{V10}$, $FL_{V15}$, $FL_{V20}$, $FL_{V25}$, $FL_{V30}$ and $FL_{V35}$ decreased 10.8%, 14.6%, 17.3%, 14.5%, 14.5% and 10.5%. $FL_{Vx}$ decreased significantly compared with $WL_{Vx}$. There were significant differences in $WL_{V10}$, $WL_{V15}$, $WL_{V20}$, $WL_{V25}$, $WL_{V3}$ and $FL_{V10}$, $FL_{V15}$, $FL_{V20}$, $FL_{V25}$, $FL_{V30}$ between plan 1 and plan 2 (P=0.002, 0.000, 0.000, 0.005, 0.027 and 0.002, 0.000, 0.000, 0.006, 0.010). According to Kendall correlation analysis, NFL had a negative relation with the percentage FLV20 decrease (r=-0.559, P<0.01), while the distance of PTV and NFL center had a significantly positive relation with the percentage of FLV20 decrease (r=0.768, P<0.01). Conclusion: Routine use of SPECT-LPI for patients undergoing radiotherapy planning for stage III NSCLC appears warranted.

An Analysis of Nurse Managers's Common Fundamental Competencies Changes and Responses to the Application of the Action Learning (실천학습 적용에 따른 간호관리자의 공통 기본역량 변화와 반응 분석)

  • Jang, Keum-Seong;Choi, Young-Ja;Ahn, Soon-Hee;Lee, Sook-Ja;Sim, Jae-Yeon;Lim, Jung-Ok;Chung, Kyung-Hee;Yang, Jin-Ju;Oh, Suk-Hee;Kim, Yun-Min;Kim, Eun-A;Bong, Hyeon-Chol;Baek, Myeong
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.12 no.3
    • /
    • pp.424-433
    • /
    • 2006
  • Purpose: This study is analyzing nurse managers's common fundamental competencies changes and responses to the application of the action learning, and promoting introduction and revitalization of action learning. Method: The research design is one group pretest-posttest design. The subjects are 40 nurse managers. The program was performed for 5 weeks. Data were collected before the program and after 5 weeks program and were analyzed with paired t-test. Result: Action learning was an effective way to develop an individual and team and to solve the problem of organization. There were more significant increases after the program than before the program on common fundamental competencies(p<.05). Conclusion: This study has us confirm that action learning is an effective education method for organization members on the spot to recognize their problem and study by themselves and solve the practical problems with various solution process.

  • PDF

RETROSPECTIVE STUDY OF FACE MASK THERAPY (FACE MASK의 치료 효과에 대한 후향적 고찰)

  • Kim, Tae-Woo;Chang, Young-Il;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.547-556
    • /
    • 1996
  • The purpose of this study was to evaluate the skeletal, dental and soft tissue profile changes following the face mask therapy in growing skeletal class III malocclusion patients. The fifteen patients with the good results were selected among the patients who visited the Department of Orthodontics in Seoul National University Hospital. The mean age was 10.63(range 7.25-13.25) years and the mean treatment duration was 9.84(range 2.00-27.00) months. Lateral cephalograms were taken just before and after face mask application. After tracing the cephalograms, thirty five items(twety angular and fifteen linear) were measured. The differences before and after the face mask therapy were compared statistically by the paired t-test(p<0.05). The results were as follows : SNA and Co-A(effective maxillary length) increased significantly after using the face mask(p<0.001), which reflects the orthopedic changes of maxilla. SNB and Co-Gn(effective mandibular length) also showed an increase(p<0.01), which may be a result of the strong growth trends of the samples. FMA, SN-GoGn and Y-axis angle increased significantly(p<0.01), which means the backward and downward rotation of the mandible. This positional change seemed to have compensated an increase of effective mandibular length. There was no statistically significant difference in angulation of upper and lower incisors between pre-treatment and post-treatment(p>0.05). In soft tissue profile, the upper lip was positioned anteriorly(p<0.01) after treatment and approximated to the normal standards.

  • PDF