• 제목/요약/키워드: Pair correlation function

검색결과 29건 처리시간 0.024초

커크우드-버프 용액 이론 (Kirkwood-Buff Solution Theory)

  • 임경희
    • 한국응용과학기술학회지
    • /
    • 제27권4호
    • /
    • pp.452-460
    • /
    • 2010
  • Any theory of liquid should account for interactions between molecules, since molecules in a liquid are close to each other. For this matter statistical-mechanical methodology has been used and various models have been proposed on the basis of this methodology. Among them Kirkwood-Buff solution theory has attracted a lot of interest, because it is regarded as being the most powerful. In this article Kirkwood-Buff solution theory is revisited and its key equations are derived. On the way to these equations, the concepts of pair correlation function, radial distribution function, Kirkwood-Buff integration are explained and implemented. Since complexity of statical mechanics involved in this theory, the equations are applied to one-component systems and the results are compared to those obtained by classical thermodynamics. This may be a simple way for Kirkwood-Buff solution theory to be examined for its validity.

Study of the Compressed and Expanded Liquid Rubidium with the Optimized Nonlocal Model Potential

  • 강홍석;박성호
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권11호
    • /
    • pp.1288-1294
    • /
    • 1999
  • We show that Shaw's optimized nonlocal model potential (OMP) in combination with the perturbative hyper-netted-chain equation for pair correlation functions can be successfully applied to predict pair structures of compressed and expanded liquid rubidium. For compressed rubidium, it is possible to apply the OMP to a state for which the model radius is even close to the Wigner-Seitz radius. In addition, our results are parallel to those from Chihara and Kahl's quantal hypernetted-chain equation in that it supports the uniform compression model up to 6.1 GPa. Calculation also shows that the pair structure is relatively insensitive to the choice of the exchange-correlation function for the electron liquid. Discussions are also given for compressed and expanded cesium.

비침습적 복압 측정을 위한 생체 임피던스 전극의 최적 위치 선정 (Optimum electrode selection for measuring the abdominal pressure using bio-impedance method)

  • 안양수;김거식;송철규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.46-48
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2$+0.0620x+0.6958, respectively. It demonstrated that the abdominal pressure could be measured non-invasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

  • PDF

Temperature Effect on the Configurational Properties of an n-Decane Chain in Solution

  • Oh, In-Joon;Ree, Tai-Kyue
    • Bulletin of the Korean Chemical Society
    • /
    • 제5권4호
    • /
    • pp.162-167
    • /
    • 1984
  • Equilibrium and dynamical behaviors of an n-alkane poymer (decane) in solution have been investigated by a molecuar dynamics simulation method. The polymer is assumed to be a chain of elements $(CH_2)$ interconnected by bonds having a fixed bond length and bond angle, but esch bond of the polymer is allowed to execute hindered internal rotation. The calculation explicitly considers the molecular naturer of solvent by including the intermolecular interactions between slovent-solvent molecules and chain element-solvent molecule. We present the results of calculations on (1) equilibrium properties (the solvent molecule-chain element pair correlation function, chain element-chain element pair correlation function, the mean square end-to-end distance and the mean square radius of gyration of the polymer) and (2) dynamic properties (four different autocorrelation functions, namely, the autocorrelation functions for the end-to-end distance and the radius of gyration, and the velocity autocorrelation functions for the center of mass and the end point of the chain). We found that the physical properties of the polymer chain depends sensitively on temperature. Comparison of the present work with other authors' results is also presented.

생체 임피던스 방법을 이용하여 복압을 측정하기 위한 최적 전극위치 선정 (Optimum Electrode Selection for Measuring Abdominal Pressure using Bio-Impedance Method)

  • 김거식;이상옥;서정환;김경섭;송철규
    • 전기학회논문지
    • /
    • 제56권7호
    • /
    • pp.1339-1342
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method and compared with conventional methods. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2+0.0620x+0.6958$, respectively. It demonstrated that the abdominal pressure could be measured noninvasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

The aerodynamic characteristics of twin column, high rise bridge towers

  • Ricciardelli, Francesco;Vickery, Barry J.
    • Wind and Structures
    • /
    • 제1권3호
    • /
    • pp.225-241
    • /
    • 1998
  • The high-rise supporting towers of long-span suspension and cable-stayed bridges commonly comprise a pair of slender prisms of roughly square cross-section with a center-to-centre spacing of from perhaps 2 to 6 widths and connected by one or more cross-ties. The tower columns may have a constant spacing as common for suspension bridges or the spacing may reduce towards the top of the tower. The present paper is concerned with the aerodynamics of such towers and describes an experimental investigation of the overall aerodynamic forces acting on a pair of square cylinders in two-dimensional flow. Wind tunnel pressure measurements were carried out in smooth flow and with a longitudinal intensity of turbulence 0.10. Different angles of attack were considered between $0^{\circ}$ and $90^{\circ}$, and separations between the two columns from twice to 13 times the side width of the column. The mean values of the overall forces proved to be related to the bias introduced in the flow by the interaction between the two cylinders; the overall rms forces are related to the level of coherence between the shedding-induced forces on the two cylinders and to their phase. Plots showing the variation of the force coefficients and Strouhal number as a function of the separation, together with the force coefficients spectra and lift cross-correlation functions are presented in the paper.

요역동학 측정시스템을 위한 새로운 복압측정 기법 (A New Approach Method of Measuring Abdominal Pressure for Urodynamic Monitoring System)

  • 서정환;김거식;안양수;김경섭;송철규
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1170-1176
    • /
    • 2007
  • The conventional urodynamic monitoring is fulfilled by artificially filling a bladder with saline. Generally. it is difficult to evaluate the physiological functions of the storage and voiding of a bladder. With this aim, we constructed an ambulatory urodynamic monitoring (AUM) system and proposed a novel method estimating abdominal pressure by measuring bio-impedance variations. Our system was clinically evaluated for 10 patients. It turned out to be that as the intensity of the abdomen contraction increased, the amplitude of bio-impedance signal and the RMS value of EMG increased more as compared to those who observed during the rest mode. Also, we determined the optimum electrode pair for estimating the abdominal pressure using bio-impedance method and consequently compared with the conventional methods. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified in terms of impedance change, correlation coefficient and SNR Our results showed the optimum electrode pair (1,9) which could detect impedance changes due to the increase of the intensity in the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2+0.0620x+0.6958$, respectively. Thus, our system demonstrated that the abdominal pressure could be measured noninvasively and conveniently by simply estimating bio-impedance values. We propose that this optimum electrode configuration would be useful for the future studies involving the handy measurements of abdominal pressure with our suggested ambulatory urodynamics monitoring system.

섬유강화 복합재료의 동탄성계수 및 감쇠특성의 이론적 예측 (Theoretical Prediction of Dynamic Elastic Moduli and Attenuation Properties of Fiber-Reinforced Composite Materials)

  • 김진연;이정권
    • 대한기계학회논문집
    • /
    • 제16권12호
    • /
    • pp.2328-2339
    • /
    • 1992
  • 본 연구에서는 일방향(unidirectional)으로 섬유가 강화된 복합재료를 다루게 되는데, 섬유는 직경이 모두 같고, 길이가 무한이며, 서로 평행하게 정렬되엉 불규칙 하게 분포된 원형실린더로 가정한다. 먼저, 임의의 한 기준 산란체에 의한 압축파 및 SV파의 산란을 수식화하고, 기준 산란체에 대한 나머지 산란체들이 존재할 확률을 이용하여 산란계수의 통계적 기대값을 구함으로써 그 매질내에 존재하는 파동의 전파 특성을 지배하는 분산 관계식의 해를 수치적으로 구함으로써 매질의 평균전파속도, 유 효 동탄성계수 및 감쇠계수를 주파수와 체적비의 함수로 구한다. 또 구하여진 동탄 성계수의 저주파 극한값과 정적하중상태에서 구한 Hashin-Rosen의 값들과 비교하여 봄 으로써 본 연구의 타당성을 입증한다.

A STUDY ON DEM GENE]RATON USING POLYNOMIAL CAMERA MODEL IN SATELLITE IMAGERY

  • Jeon, Seung-Hun;Kim, Sung-Chai;Lee, Heung-Jae;Lee, Kae-hei
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.518-523
    • /
    • 2002
  • Nowadays the Rational Function Model (RFM), an abstract sensor model, is substituting physical sensor models for highly complicated imaging geometry. But RFM is algorithm to be required many Ground Control Points (GCP). In case of RFM of the third order, At least forty GCP are required far RFM generation. The purpose of this study is to research more efficient algorithm on GCP and accurate algorithm similar to RFM. The Polynomial Camera Model is relatively accurate and requires a little GCP in comparisons of RFM. This paper introduces how to generate Polynomial Camera Model and fundamental algorithms for construction of 3-D topographic data using the Polynomial Camera Model information in the Kompsat stereo pair and describes how to generate the 3-D ground coordinates by manual matching. Finally we tried to extract height information for the whole image area with the stereo matching technique based on the correlation.

  • PDF

Correlation Between Exposure Rate and Quasi-Effective Energy of Natural Radiation in Japan -TLD Application-

  • Nakajima, Toshiyuki
    • Journal of Radiation Protection and Research
    • /
    • 제12권1호
    • /
    • pp.54-60
    • /
    • 1987
  • The quasi-exposure rate and the quasi-effective energy of the natural radiation in the field at 47 monitoring points around nuclear power plants have been studied with the pair filter thermoluminescence dosimeter system. The results of the six years observation showed that the relationship between the quasi-exposure rate $X_q$, and quasi-effective energy $E_q$ can be represented as a hyperbolic function: $X_q=A+C/(E_q-B)$, where the constants A and B correspond to the quasi-exposure rate of cosmic-rays and the minimum quasi-effective energy of natural radiation, respectively. Furthermore, the constant A is in close agreement with the values obtained by using ionization chambers and scintillation detectors. The constant B is approximately 0.68 MeV, closely corresponding to the mean energy of the photons emitted from natural uranium.

  • PDF