Properties of Paint Protection Film Containing Poly(urea-urethane)-based Self-Recovery Coating Layer (Poly(urea-urethane) 자기복원 코팅층을 가진 도장 보호필름 물성 연구)

  • Minseok Song
    • Journal of Adhesion and Interface
    • /
    • v.24 no.2
    • /
    • pp.69-75
    • /
    • 2023
  • Recently, the application of paint protection films (PPFs) for automobiles having a self-recovery coating layer has been grown up. In this study, we report the evaluation results on the basic physical properties of a poly(vinyl chloride)- based PPF containing poly(urea-urethane) hybrid self-recovery coating layer. Depending on the main chemical composition and the thickness of poly(urea-urethane)-based coating layer for PPF, the self-recovery performance by an optical microscope and the stain resistance through color difference value are measured. To improve the surface properties and show its easy-cleaning effect against the polluted things, silicone-modified polyacrylate is introduced to the self-recovery coating composition. The contact angle of water on the coated surface is confirmed to show its hydrophobic surface. Finally, accelerated weathering test of paint protection film with poly(urea-urethane) hybrid coating layer is performed to check the possibility of discoloration and deformation due to long-term exposure on harsh condition.

Experimental Study on the Development of Electromagnetic Pulse Shielding Inorganic Paint Using Carbon Materials (탄소 재료를 사용한 전자파 차폐 무기계 도료 개발에 관한 실험적 연구)

  • Kyong-Pil Jang;Tae-Hyeob Song
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.234-243
    • /
    • 2023
  • The electromagnetic pulse(EMP) is a general term for high-output electromagnetic waves, and is classified into EMP generated from nuclear weapons, non-nuclear EMP, and EMP generated by natural phenomena. Electromagnetic pulses are means that can cause fatal damage to all electronic devices with electromagnetic elements, such as communication devices, mobile phones, computers, TVs, and means of transportation. In this study, the electromagnetic pulse(EMP) shielding effectiveness evaluation of paints according to the type and amount of carbon material was conducted to develop EMP shielding inorganic paint using carbon materials. In order to analyze the improvement of compatibility and dispersibility between materials, experiments were conducted two times with about 27 types of mixture proportions, and the electromagnetic pulse shielding effectiveness was evaluated by the electrical resistance measurement method. As a result of applying the EMP shielding paint developed through this study to shielding concrete, it was confirmed that the shielding performance was improved from about 25 dB to a maximum of 40 dB.

Measurement of the Film Cooling Effectiveness using Pressure Sensitive Paint on Convergent/Divergent Channel (압력감응페인트를 이용한 확대/축소 유로에서의 막냉각 효율 측정)

  • Park, Seoung-Duck;Lee, Ki-Seon;Kim, Sung-Ha;Kim, Hark-Bong;Kwak, Jea-Su;Kim, Chun-Teak;Yang, Gyae-Byung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.6
    • /
    • pp.31-37
    • /
    • 2008
  • Film cooling effectiveness on the convergent or divergent channel was measured by pressure sensitive paint technique. The channel convergent or divergent angle was changed from $-5^{\circ}$ to $10^{\circ}$ and the tested blowing ratios were 0.5, 1 and 2. Results showed that the film cooling effectiveness on the convergent channel was not much affected by the convergent angle. With divergent film cooled surface, the film cooling effectiveness near the injection hole decreased as the divergent angle increases. However, the film cooling effectiveness at far downstream from the hole showed opposite trend. For the non-film cooled surface inclined case, the film cooling effectiveness was not much affected by the divergent angle.

Study on the Compositional Construction of Epoxy Based Powder Paint (환경친화형 에폭시계 분체도료의 조성구축 연구)

  • Lim, Hong-Joon;Chung, Kyung-Ho
    • Clean Technology
    • /
    • v.12 no.1
    • /
    • pp.27-35
    • /
    • 2006
  • Main compositions of powder paint based on thermoset type epoxy resin consist of epoxy resin for powder coating, curing agent, filler and pigment. The curing system used in this study was based on diglycidyl ether of bisphenol-A (DGEBA) and dicyan diamide (DICY). The curing behavior and rheological properties of powder coating material were investigated using DSC and rheometer, respectively. And the adhesion strength between steel and powder coating material was measured using lap shear geometry. The optimum formulation of epoxy powder paint obtained from this study was base resin of 100 phr, DICY of 6 phr, $CaCO_3$ of 20 phr, and $TiO_2$ of 10 phr.

  • PDF

Evaluation of the Fire Resistance Performance of Interior Anchor Type CFT Columns through Loaded Heating Test

  • Kim, Sunhee;Yom, Kyongsoo;Choi, Sungmo
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.39-48
    • /
    • 2013
  • The fire resistance performance of generic CFT columns has been verified through various tests and analyses and the columns are widely used for fire resistance designs abroad. In this study, 3 groups of specimens (Non-fire protection, reinforcement with steel fiber and fire resistance paint) are suggested in order to evaluate the fire resistance performance of interior anchor type concrete-filled steel tubular columns having efficient cross-sections through loaded heating tests. Axial deformation-time relationship and in-plane temperatures are compared to evaluate the fire resistance performance of the specimens associated with variables. Suggested from the fact that the interior anchors exposed to fire exert influence on fire resistance performance due to thermal expansion, the reinforcements using steel fiber and fire resistance paint are verified to mitigate contraction and improve fire resistance performance. The result obtained from the tests of interior anchor type concrete-filled tubular columns is expected to be used for effective fire resistance design in association with previously conducted studies.

The Measurement Method of Thermal Conductivity and Diffusivity of Thin Paint Layer Sprayed on Solid Surface (고체표면에 도포한 도료 박막의 열전도율과 열확산율의 측정법)

  • Kim, Eun-young;Park, Soo-Chun;Kim, Byung-Mun;Lee, Doug-Bong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.3
    • /
    • pp.311-319
    • /
    • 1999
  • The thermal conductivity ${\lambda}_b$, thermal diffusivity ${\alpha}_b$ of the thin black paint layer sprayed on solid surface and absorptivity a for laser beam are measured by applying a non-contact measurement method of the thermophysical properties of solids. The values of a=0.67, ${\lambda}_b=1.45W/mK$ and ${\alpha}_b=1.24{\times}10^{-6}m^2/s$ are obtained for the sprayed lay~ thickness $z_b{\fallingdotseq}40\;{\mu}m$. Furthermore, for the $z_b{\fallingdotseq}24\;{\mu}m$ thick layers which arc formed by rubbing with a glass rod after spraying, the values of a=0.73, ${\lambda}_b=1.85W/mK$. and ${\alpha}_b=1.09{\times}10^{-6}m^2/s$ are obtained. It is also shown that the present thermal diffusivity ${\alpha}_b$ for $z_b{\fallingdotseq}40\;{\mu}m$ Is about 30~80% larger than those obtained by Araki et al. for the thicker layer $z_b{\fallingdotseq}150{\sim}248\;{\mu}m$. This method could be applied to the measurement of thermophysical properties of thin layer on solids.

An Electrochemical Evaluation on the Corrosion Resistance of Heavy Anticorrosive Paint (중방식도료의 내식성에 관한 전기화학적 평가)

  • Sung Ho-Jin;Kim Jin-Kyung;Lee Myung-Hoon;Kim Ki-Joon;Moon Kyung-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.519-525
    • /
    • 2005
  • An electrochemical evaluation on the corrosion resistance for heavy anticorrosive paint(DFT:25um) was carried out for 5 kinds of heavy anticorrosive paints such as high solid epoxy(HE), solvent free epoxy(SE). tar epoxy(TE), phenol epoxy(PE). and ceramic epoxy(CE). Corrosion current densities obtained by Tafel extrapolation method from anodic and cathodic polarization curves didn't correspond with the values obtained by AC impedance measurement, however, the values of polarization resistance obtained from the cyclic voltammogram showed a good tendency corresponding well with the values of AC impedance measurement. Futhermore there was a good correlation against the corrosion resistance evaluation between passivity current density of the anodic polarization curve and diffusion limiting current density of the cathodic polarization curve. And corrosion resistance increased with corrosion potential shifting to noble direction. From the results discussed above. HE and CE had a relatively good corrosion resistance than other heavy anticorrosive paints.

A Study on the Electromagnetic Shielding of Conductive Powder (도전성(導電性) 분체(粉體)의 전자차폐(電磁遮蔽)에 관한 연구(硏究))

  • Kim, Dong-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.244-249
    • /
    • 2004
  • In this paper, shielding effectiveness(SE) of the shielding paint of electromagnetic(EM) waves was investigated with actual experiments. The shielding paint used in this study were made of powder of conductive materials - Ag, Cu, Al, Sn, Ni. Cr, Graphite and Charcoal etc. with a solubility in oil and water. Also, the paper was used as a base sheet. The experiment was carried out by using a shielding evaluator(Shielding box) TR17302 with an ADVANTEST spectrum analyzer, model R3361C. It was found from the experimental results that silver, copper, nickel were good candidates as a shielding material against the EM waves with increasing the SE as the composite was laminated. The characteristics of the SE against the EM waves depended on a mode of preparation of specimen. The effects of density of particles on the SE were studied about the EM shielding paint. The SE strongly depended on the electric resistance by density of painting particles. SE increased as the density of particles was increasing.

  • PDF

Performance Appraisal of the Ceramic Metal Resin Paints for Waterproof and Anti-Corrosion to Improve the Property of Concrete Structure (콘크리트 구조물의 표층부 내구성 증진을 위한 세라믹 메탈계 방수$\cdot$방식재 도료의 성능 평가 연구)

  • Jun Byung-Hun;Kim Jin-Sung;Kang Hyo-Jin;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.113-117
    • /
    • 2005
  • The ceramic metal resin paints for waterproof and anti corrosion is not long history in development of materials even many actual result. So far, no standard have been given to construction and maintenance method, Quality and property, it is real state that cannot afford to proper quality control in job site or production. This study has been test for the ceramic metal resin paints for water and anti corrosion, as the result, it have proper performance of job site and mechanical performance of compare to other existing. In particular, tensile strength indicates more high about $14.1N/mm^2$ than epoxy resin paints, and in elongation per unit length is more high It is shows having better adhesive strength than epoxy resin paint for crack on the concrete structure. Moreover, The ceramic metal paint for water and corrosion proofing have to have main performance is watertightness and resistance for external impact, chloride ion permeation, drinkable water elution.

  • PDF

Endocrine Disrupting Effects of the Industrial Wastewater Effluents Discharged from the Treatment Plant (산업폐수처리장 방류수의 내분비계 장애작용 평가)

  • Oh Seung-Min;Kim Gi-Suh;Ryu Byung Taek;Jang Hyung Seog;Lee Hee-Sung;Chung Kyu-Hyuck
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.4
    • /
    • pp.375-382
    • /
    • 2004
  • This study was designed to investigate potential endocrine disrupting effects of several industrial wastewater effluents discharged from cosmetic, plaiting, paint, textile industry using EROD bioassay and E-Screen assay. The results of E-screen assay showed that textile industrial wastewater could act as a full agonist and cosmetics and plaiting industrial wastewater could act as a partial agonist. On the contrary, the wastewater discharged from paint industry did not show any estrogenic effect. Estrogenic activity in the effluents of cosmetic and paint industrial wastewater was lower than that in the influents indicating that the wastewater treatment process minimized the effects of discharges on water quality. Despite of these results, it was recognized that wastewater treatment was not always minimize toxic impact. In this study, increased estrogenic effect was observed in the effluents of plating and textile wastewater, and EROD activity was increased in the effluents of cosmetic and plating wastewater.