• 제목/요약/키워드: Packing Effect

검색결과 380건 처리시간 0.03초

Effect of Open Packing upon Vertex Removal

  • Hamid, Ismail Sahul;Saravanakumar, Soundararajan
    • Kyungpook Mathematical Journal
    • /
    • 제56권3호
    • /
    • pp.745-754
    • /
    • 2016
  • In a graph G = (V, E), a non-empty set $S{\subseteq}V$ is said to be an open packing set if no two vertices of S have a common neighbour in G. The maximum cardinality of an open packing set is called the open packing number and is denoted by ${\rho}^{\circ}$. In this paper, we examine the effect of ${\rho}^{\circ}$ when G is modified by deleting a vertex.

Packing density and filling effect of limestone fines

  • Kwan, A.K.H.;McKinley, M.
    • Advances in concrete construction
    • /
    • 제2권3호
    • /
    • pp.209-227
    • /
    • 2014
  • The use of limestone fines (LF) in mortar and concrete can in certain ways improve performance and thus has become more and more commonplace. However, although LF is generally regarded as a filler, it is up to now not clear how much filling effect it could have and how best the filling effect could be utilized. Herein, the packing density and filling effect of LF were studied by measuring the packing densities of LF, (LF + cement) blends and (LF + cement + fine aggregate) blends under dry and wet conditions, and measuring the performance of mortars made with various amounts of LF added. It was found that the addition of LF would not significantly increase the packing density of (LF + cement) blends but would fill into the paste to increase the paste volume and paste film thickness, and improve the flow spread and strength of mortar.

사출성형 시 성형제품치수에 미치는 패킹변수의 영향 (Effects of Packing Parameter on Plastic Article Dimensions in the Plastic Injection Molding)

  • 김범준;신주경;이정구;손일선
    • 한국정밀공학회지
    • /
    • 제31권1호
    • /
    • pp.9-13
    • /
    • 2014
  • The molding process can be divided into five separate steps: plastification, injection, holding, cooling, and finally ejection. In the plastic injection molding, the effect factor such as mold temperature, injection speed, packing pressure and inhomogeneous cooling under packing process affects both the article dimension and physical characteristics. Especially, the packing pressure is the most critical factor to affect molded articles quality among the packing parameters. In this paper, the CAE simulation considering the molding condition is performed to predict the faulty cause which appears in the packing process between cavities of injection molding machine. From the results of CAE simulation, the packing phenomena according to the product form and the gate position was investigated to improve the article quality and minimize the various molding defects. The effect of packing pressure and gate number on the injection molding was discussed.

보스 벽 두께가 사출성형의 싱크마크 발생에 미치는 영향 (Effect of Boss Wall Thickness on Sink Mark in Injection Molding)

  • 김현필;김용조
    • Design & Manufacturing
    • /
    • 제6권1호
    • /
    • pp.5-11
    • /
    • 2012
  • The sink mark on boss parts is generated by the volumetric shrinkage that is caused by both the molding thickness and the boss wall thickness. The volumetric shrinkage is caused by packing pressure and its amount tends to decrease by increasing the packing pressure. The packing pressure can therefore increase the flow rate to a boss part and causes the depth of sink mark to increase. As the molding thickness and the boss wall thickness in the boss part can increase the part volume, these may yield bad solidifying and also extend the molding cycle. In this paper, both the injection molding test and the flow analysis were carried out to investigate the effect of sink mark that was generated in the boss wall thickness of injection molded products. The sink mark could also be caused by thickness ratio of boss part. For a given thickness ratio of boss, several molding process parameters such as packing pressure, packing time and melt temperature, affecting to generation of the sink mark were discussed.

  • PDF

보스 벽 두께가 사출성형의 싱크마크 발생에 미치는 영향 (Effect of Boss Wall Thickness on Sink Mark in Injection Molding)

  • 김현필;김용조
    • 한국금형공학회:학술대회논문집
    • /
    • 한국금형공학회 2008년도 하계 학술대회
    • /
    • pp.103-109
    • /
    • 2008
  • The sink mark on boss parts is generated by the volumetric shrinkage that is caused by both the molding thickness and the boss wall thickness. The volumetric shrinkage is caused by packing pressure and its amount tends to decrease by increasing the packing pressure. The packing pressure can therefore increase the flow rate to a boss part and causes the depth of sink mark to increase. As the molding thickness and the boss wall thickness in the boss part can increase the part volume, these may yield bad solidifying and also extend the molding cycle. In this paper, both the injection molding test and the flow analysis were carried out to investigate the effect of sink mark that was generated in the boss wall thickness of injection molded products. The sink mark could also be caused by thickness ratio of boss part. For a given thickness ratio of boss, several molding process parameters such as packing pressure, packing time and melt temperature, affecting to generation of the sink mark were discussed

  • PDF

포장방법이 동결계육의 이화학적 특성에 미치는 영향 (Effect of Packing Method on Physico-chemical Properties of Frozen Chicken)

  • 박구부;하정기;박범영;이상진;박용윤;박태선;신택순;이정일
    • 한국가금학회지
    • /
    • 제23권4호
    • /
    • pp.193-201
    • /
    • 1996
  • This experiment was carried out to find out the effect of packing methods on physico-chemical properties of breast and thigh meats in chicken, which was dried by air spray chilling method. The chicken carcass was cut into breast and thigh muscles, which were either vacuum packed or atmosphere packed, and stored at -2O˚C for 1, 4, 8, 12 and 16 wk after quick freezing at -45˚C for 35 min. The pH values of atmosphere-packed breast meat and vacuum-packed breast meat after one wk of storage were higher than those of atmosphere-packed thigh meat and vacuum-packed thigh meat(P< .05). The pH values increased as storage period extended, but no significant difference was detected between two packing method(vacuum vs. atmosphere). Total moisture contents of breast meats after one wk of storage were higher than those of thigh meats. The total moisture contents decreased slowly as storage period extended, but no significant difference was detected between two packing method(vacuum vs. atmosphere). The shear force value of thigh meat was higher than that of breast meat. The shear force values of both meats decreased as storage period extended, regardless of packing method. The water soluble protein extractability of thigh meats was higher than that of breast meat, and the water soluble protein extractability of all treatments decreased until 8 wk after storage, but increased gradually after 8 wk of storage period. The salt soluble protein extractability of breast meat was higher than that of thigh meat, and the salt soluble protein extractability of all treatments decreased as storage period extended. With regard to the packing method, the vacuum packing showed higher value than that of atmosphere packing method until 8 wk of storage. Total lipid contents of atmosphere- and vacuum-packed thigh meats at 1 wk of storage were higher than those of breast meats, and the total lipid contents of all of treatments decreased as storage period extended. However, no significant difference was detected between two packing methods. The fatty acid contents of breast and thigh meats were in order of o1eic(33,5~42.4), palmitic(19.7~30.8) and linoleic acid(10.8~17.4).

  • PDF

고정상 담체를 충전한 활성슬러지 공정에서 DO농도와 HRT 및 담체 충전율 변화가 질소 제거효율에 미치는 영향 (The Effects of DO, HRT, and Media Packing Ratio on Nitrogen Removal Efficiency in BCM-ASR System)

  • 황규대;한봉석
    • 한국물환경학회지
    • /
    • 제24권6호
    • /
    • pp.659-669
    • /
    • 2008
  • Two sets of four parallel activated sludge reactors (ASRs) maintaining an MLSS of 3000 mg/L were operated to investigate the effect of DO, HRTs and bio-contact media (BCM) packing ratios on the removal efficiency of organic matters and nitrogen. Packing ratios of BCM to BCM-ASR systems 1, 2, 3, and 4 were 0% (suspended growth only), 10%, 15% and 20%, respectively. All systems were operated at an HRT of 4 hr, 6 hr, and 8 hr, respectively; DO concentration was maintained 0.5~1.0 mg/L and 1.5~2.0 mg/L for each HRT condition. In terms of TSS, TCODcr and SCODcr removal efficiency, all systems had a similar level of the removal efficiency under varied HRTs, and DO. But organic removal efficiency of systems with BCM was approximately 3~5% higher than systems without BCM at the same HRT and the DO. About the nitrification efficiency, with high DO (1.5~2.0 mg/L), as HRT (4 hr, 6 hr, 8 hr) or BCM packing ratio increased, the slight increment of nitrification efficiency was observed. However, under the low DO (0.5~1.0 mg/L), increase of BCM packing ratio and HRT resulted in large increase of the nitrification efficiency. At the same HRT and BCM packing ratio, the nitrification efficiency increased greatly with up to 15% as DO increased. When the HRT increased from 4hr to 8hr, the denitrification efficiency slightly increased by 5~10% only, under all DO conditions. Systems with BCM had higher denitrification efficiency, ranged 62.7~91.1% than systems without BCM showed 32.1~65.6%. And the increase in BCM packing ratio from 10% to 20% resulted in about 14~16% denitrification efficiency increment. BCM packing ratio showed great effect on the denitrification. The increase of the DO (from 0.5~1.0 mg/L to 1.5~2.0 mg/L) at the same HRT and BCM packing ratio resulted in slight decrease of denitrification efficiency with up to 7% for systems with BCM. But for systems without BCM, the denitrification efficiency decreased with up to 28%. In all system, the denitrification efficiency had more influence on the TN removal efficiency than nitrification efficiency. So, BCM packing ratio (0%, 10%, 15%, 20%) has greater effect on the TN removal than HRT and DO. The TN removal efficiency increased as packing ratio of BCM increased with up to 45%. As a result, the highest TN removal efficiency was observed 73.7% at the condition showed the highest denitrification efficiency that DO of 0.5~1.0 mg/L, an HRT of 8 hr, and 20% of BCM packing ratio was maintained.

자궁경부암 강내조사 3차원 치료계획 시 Packing의 유용성 분석 (Packing effects on the intracavitary radiation Therapy 3-Dimension plan of the uterine cervix cancer)

  • 시창근;조정근;이두현;김선영;김태윤
    • 대한방사선치료학회지
    • /
    • 제17권1호
    • /
    • pp.1-8
    • /
    • 2005
  • 목적 : CT영상을 이용한 삼차원치료계획을 수립하여 방광과 직장의 점선량(point dose)과 체적선량(volume dose)에 대해 선량-체적 히스토그램(Dose-Volume Histogram)을 이용하여 자궁경부암의 강내치료에 사용하는 packing의 효과를 분석하였다. 대상 및 방법 : 자궁경부암 환자 7명을 대상으로 하여 동일조건하에서 packing을 시행했을 때와 제거했을 때 각각 CT촬영(Ultra Z, marconi, USA)을 하여 치료계획장치(Plato Brachy the Rapy V14.2.4)에서 방광과 직장의 reference point를 각각 표시하고 ICRU38에 따라 A point에 치료계획을 시행하였다. 하지만 rectum의 경우 ICRU에서 제시한 point가 rectum 선량을 대표할 수 있는 값으로 적절하지 않기 때문에 maximum point를 찾아 비교하였다. 그리고 rectum과 bladder의 $50\%,\;80\%,\;100\%$선량의 volume에 따른 체적선량을 알아보았다. 측정한 값들을 윌콕슨 부호검정(SAS 통계분석처리 프로그램)을 통하여 packing의 효과를 분석하였다. 결과 : Packing 제거 시에서의 방광과 직장의 reference point 선량은 $116.94{\pm}35.42\%,\;117.59{\pm}21.08\%$이었고, packing 시행한 경우에는 각각 $107.08{\pm}38.12\%,\;95.19{\pm}21.32\%$이었다. Packing시행 후에 방광은 $9.86\%$, 직장은 $22.4\%$감소하였다. Packing제거시의 방광과 직장 maximum point 선량은 $164.51{\pm}50.89\%,\;128.81{\pm}33.05\%$, packing시행한 경우 각각 $142.31{\pm}44.79,\;110.08{\pm}37.03\%$이었다. packing시행 후에 방광과직장 maximum point 선량이 $22.2\%,\;18.73\%$줄어들었다. packing제거시 방광과 직장선량의 $50\%,\;80\%,\;100\%$선량의 Volume은 방광이 $48.62{\pm}18.09\%,\;16.12{\pm}11.15\%,\;7.51{\pm}6.63\%$, 직장이 $23.41{\pm}14.44\%,\;6.27{\pm}4.28\%,\;2.79{\pm}2.27\%$이었고, packing시행한 경우의 $50\%,\;80\%,\;100\%$선량의 volume은 방광이 $40.33{\pm}16.72\%,\;11.63{\pm}8.72\%,\;4.87{\pm}4.75\%$, 직장이 $18.96{\pm}8.37\%,\;4.75{\pm}2.58\%,\;1.58{\pm}1.06\%$이었다. packing시행 후에 $50\%,\;80\%,\;100\%$선량의 volume 방광은 $8.29\%,\;4.49\%,\;2.64\%$, 직장은 $4.45\%,\;1.52\%,\;1.21\%$ 감소하였다. 결론 : 자궁경부암의 강내치료 시 사용하는 packing의 효과를 CT를 이용한 삼차원치료계획을 통하여 알아본 결과 ICRU 38에서 권고하는 방광과 직장의 기준 점선량(reference point dose)의 경우 P값이 각각 0.0781, 0.0781이었고, 최대점선량(maximum point dose)은 P값이 각각 0.0156, 0.0156으로써 유의한 차이를 보이는 것으로 나타났으나 $50\%,\;80\%,\;100\%$를 초과하는 체적선량(volume dose)의 경우 p갈이 0.15이상으로써 유의하지 않은 것으로 나타났다. 다시 말해서 packing의 효과가 점선량의 경우 차이가 있는 것으로 보이지만 실제 체적선량은 별 차이가 없는 것으로 분석되었다. 그 이유를 살펴보니 방광과 직장의 용적(volume)은 넓은데 비해 packing을 하는 부분은 일부분에 지나지 않아서 큰 선량감소의 효과가 없었던 것으로 보인다. 하지만 방사선의 강도는 거리 역 제곱에 비례하므로 거리가 멀면 멀수록 방사선의 강도는 약해진다. 따라서 packing을 실시하여 방광과 직장의 장해를 최소화하는데 노력을 기울여야 할 것이다.

  • PDF

반나절 비강충전이 비골 골절 수술결과에 미치는 영향 (The Effect of Half Day Nasal Packing in Results of Closed Reduction of Nasal Bone Fracture)

  • 한동길;김태섭
    • 대한두개안면성형외과학회지
    • /
    • 제13권2호
    • /
    • pp.119-124
    • /
    • 2012
  • Purpose: Closed reduction and nasal packings for 3-7 days is usual procedures in managing nasal bone fracture. Most patients experience several discomfort owing to lack of nasal breathing. There are many reports concerning how to reduce patient's discomforts or complications. But it is obvious that the duration of nasal packing is 3-7 days. The aim of this study is evaluate the effect of half day nasal packing in results of nasal bone fracture. Methods: The study was performed on 97 nasal bone fracture patients who had simple nasal bone fractures from January to June 2012. The incidence, cause, patient's discomfort and satisfaction with half day nasal packing are analyzed according to patient's medical records and questionnaire at each nasal packing removal, postoperative 4 weeks. Results: Young male patients, especially the teenagers and the twenties were the common age group, and physical violence was most common cause of injury. A total of 78 out of 97 patients were male. In 92 cases, closed reduction were applied. Approximately, 87% of the patients were satisfied with the outcomes. Conclusion: Half day nasal packing is considered as an effective method to minimize patient's discomfort owing to prolonged absence of nasal breathing with maintenance of stability.

비골 골절 교정 후 Rolled Silastic Sheet를 이용한 비강 충진의 효과 (The Effect of Nasal Packing with Rolled Silastic Sheet after Closed Reduction of Nasal Bone Fracture)

  • 손경민;양정열;김규보;한윤주;천지선
    • Archives of Plastic Surgery
    • /
    • 제38권5호
    • /
    • pp.602-608
    • /
    • 2011
  • Purpose: Nasal bone fracture is the most common type of facial bone fracture and most of nasal bone fracture is combined with septal fracture frequently. Nasal septum is important to support the distal nose and to maintain the nasal airway. But nasal septal fractures are usually unrecognized and untreated at the time of operation. Recently, various materials were using for nasal packing after closed reduction, however these materials are not focused on the correction of nasal bone and nasal septal fracture and many patients are suffered from nasal packing materials. Thus, the purpose of this study is to compare routine packing materials and rolled silastic sheet with respect to postoperative effect of correction of nasal bone fracture and discomfort of nasal packing materials. Methods: We examined 320 patients treated nasal bone fracture from January 2008 to December 2010. For Group I (n=92), $Merocel^{(R)}$ was used for nasal packing, for Group II (n=152) vaseline gauze was used, and Rolled silastic sheet (RSS) with vaseline gauze packing (VGP) was used for Group III (n=76). Under the general anesthesia, all patients were operated by closed reduction and nasal packing was done using three kinds of packing materials. At the time of postoperative 7 days, packing material was removed and studied for pt's satisfaction and postop. complications. Results: In patients with RSS with VGP, the complaints (nasal obstruction, foreign compressive sensation and discomfort during food ingestion) of keeping the nasal packing were decreased ($p$ <0.05) and the postoperative complication (deviation) were decreased comparing to vaseline gauze packing and $Merocel^{(R)}$ packing, however, these differences were not statistically significant ($p$ >0.05). Conclusion: Postoperative nasal packing with RSS with VGP was more comfortable to the patients and it was more effective method to correct the nasal bone fracture and nasal septal fracture.