• Title/Summary/Keyword: PWm Rectifier

Search Result 287, Processing Time 0.026 seconds

A Zero-Current-Transition Synchronous Buck Converter Using Auxiliary Circuit with Soft-Switching (소프트 스위칭 방식의 보조 회로를 활용한 영전류 천이형 싱크로너스 벅 컨버터)

  • Lee, Eui-Cheon;Choi, Hyun-Chil
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.359-366
    • /
    • 2013
  • This paper proposes a zero-current-transition(ZCT) synchronous buck converter using auxiliary circuit with soft-switching for light weight and high efficiency. In this scheme, an auxiliary circuit is added to the conventional synchronous rectifier buck converter and used to achieve soft-switching condition for both the main switch and synchronous switch. In addition, the switch in the auxiliary circuit operates under soft-switching conditions. Thus, the proposed converter provides a higher efficiency. The basic operations, in this paper, are discussed and design guidelines are presented. The usefulness of the proposed converter is verified on a 200KHz, 20 W prototype converter.

A Study On The Power Factor Correction Of The Boost Converter Without The Input Current Measurement (입력 전류의 측정이 필요없는 Boost 컨버터의 역률 보정에 관한 연구)

  • Cho, Sang-Jun;Lee, Kwang-Won
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.376-378
    • /
    • 1996
  • This paper presents a new PFC control method which replaces a fast line current measurement with a filtered load current measurement. Using the power balance relation between the input and the output of the boost converter. the input current can be described as the function of load current. Thus the PWM signal which effects the switching control of the boost converter is generated using the PFC input voltage, the PFC output voltage and the load current as input variables. By using a filter between the bridge rectifier and a dc-to-dc converter, the input voltage of the dc-to-dc converter is forced to always maintain above zero volt. Then the input current traces a sinewave in phase. The proposed scheme accomplishes a very high power factor and a low harmonic distortion of the line current. The validity of this scheme is demonstrated through simulation.

  • PDF

Air-Conditioner Power Source device to meet the Harmonic guide lines (에어컨 전원장치의 고조파 저감)

  • Mun Sang-Pil;Suh Ki-Young;Lee Hyun-Woo;Kim Young-Mun
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.171-174
    • /
    • 2001
  • This paper proposes a nonlinear impedance circuit composed by diodes and inductors or capacitors. This circuit needs no control circuits and switches, and the impedance .value is changed by the polarity of current or voltage. and this paper presents one of these applications to improve the input current of capacitor input diode rectifiers. The rectifier using the nonlinear impedance circuit id constructed with four diodes and four capacitors in addition to the conventional rectifiers, that is, it has eight diodes and five capacitors, including a DC link capacitor. It makes harmonic components of the input current reduce and the power factor improve. A circuit design method is shown by experimentation and confirmed simulation. It explained that compared conventional pulse width modulated (PWM) inverter with half pulse-width modulated (HPWM) inverter. Proposed HPWM inverter eliminated dead-time by lowering switching loss and holding over-shooting.

  • PDF

A study of regenerative inverter system with capability of harmonic reduction (고조파 저감 능력을 가진 회생용 인버터 시스템 연구)

  • Choi, Chang-Youl;Bae, Chang-Hwan;Jang, Su-Jin;Song, Sang-Hun;Won, Cung-Yeun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.443-448
    • /
    • 2005
  • This paper proposed a regeneration inverter system, which can regenerate the excessive power form dc bus line to ac source for traction system. The proposed regeneration inverter system for dc traction can reduce harmonics which are include to ac current source. The regenerative inverter is operated as two modes. As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. In the paper, a regeneration inverter used PWM DC/AC converter algorithm. And an active power filter used p-q theory. The simulation was composed as a prototype model[3kW]. Simulation results show that two algorithm can be used to real model[100kW]. Finally, the inverter was successfully operated as regeneration mode.

  • PDF

A Novel Soft-Switching Full-Bridge PWM Converter with an Energy Recovery Circuit

  • Lee, Dong-Young;Cho, Bo-Hyung;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.809-821
    • /
    • 2009
  • This paper proposes a new phase-shift full-bridge DC-DC converter by applying energy recovery circuits to a conventional full-bridge DC-DC converter in plasma display panel applications. The converter can achieve soft-switching in main-switches by an extra auxiliary resonant network even with the wide operating condition of both output load and input voltage. The un-coupled design guidelines to the main bridge-leg component parameters for soft-switching operation contribute to conduction loss reduction in the transformer primary side leading to efficiency improvement. The auxiliary switches in the resonant network also operate in zero-current switching. This paper analyzes the operation modes of the proposed scheme and presents the key design guidelines through steady state analysis. Also, the paper verifies the validity of the circuits by hardware experiments with a 1kW DC/DC converter prototype.

Bidirectional High-Frequency Link Inverter with Deadbeat Control

  • Salam, Zainal
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.726-735
    • /
    • 2009
  • This paper presents a Bidirectional High-Frequency Link (BHFL) inverter that utilizes the Deadbeat controller. The main features of this topology are the reduced size of the inverter and fewer power switches. On the secondary side of the transformer, the active rectifier employs only two power switches, thus reducing switching losses. Using this configuration, the inverter is capable of carrying a bidirectional power flow. The inverter is controlled by a Deadbeat controller, which consists of the inner current loop, outer voltage loop and a feedforward controller. Additional disturbance decoupling networks are employed to improve the system's robustness towards load variations. A 1-kVA prototype inverter has been constructed and the Deadbeat control algorithm is experimentally verified. The experimental results show that the inverter has high efficiency (91%) with low steady state output voltage total harmonics distortion (1.5%).

Analysis and Design of a Soft-Switched PWM Sepic DC-DC Converter

  • Kim, In-Dong;Kim, Jin-Young;Nho, Eui-Cheol;Kim, Heung-Geun
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.461-467
    • /
    • 2010
  • This paper proposes a new soft-switched Sepic converter. It has low switching losses and low conduction losses due to its auxiliary communicated circuit and synchronous rectifier operation, respectively. Because of its positive and buck/boost-like DC voltage transfer function (M=D/(1-D)), the proposed converter is desirable for use in distributed power systems. The proposed converter has versions both with and without a transformer. The paper also suggests some design guidelines in terms of the power circuit and the control loop for the proposed converter.

A single-carrier comparison PWM method for Voltage Control of Vienna Rectifier (단일 반송파를 이용한 Vienna Converter의 전압 제어)

  • Yoon, Byung-Chul;Shin, Hee-Kuen;Kim, Hag-Wone;Cho, Kwan-Yuhl;Lim, Byung-Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.149-150
    • /
    • 2011
  • 본 논문에서는 3-Level Vienna Converter를 간단히 제어 하기 위한 단일 반송파 비교 방식의 전압제어 방법을 제안 한다. 제안된 전압 제어 방식은 Two-Level 전압 변조 방식의 상전압 지령과 단자 전압 지령은 그대로 사용하고, 삼각파 비교부만 비엔나 정류기에 적합하게 단일 반송파를 이용한 방식으로 바꿔 SVPWM을 간단하게 구현할 수 있으며, 기존의 Two-Level 컨버터에서 적용하던 다양한 선형 변조 및 과변조 방식 등 전압제어 알고리듬과 전류제어 알고리듬 등을 Three - Level 컨버터에 쉽게 적용 할 수 있다.

  • PDF

A Study on Active Power Filter for Compensation of Power Factor and Harmonic Currents (역률개선 및 고조파 보상을 위한 능동전력필터에 관한 연구)

  • Kim, Y.H.;Kim, J.S.;Kwon, G.H.;Chung, Y.H.;Choi, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1074-1076
    • /
    • 1992
  • By using nonlinear loads in power line, reactive power and harmonics are occured. In this thesis, on the basis of the instantaneous reactive power theory, the calculation method of compensation current commands and the current control characteristics of active power filter using voltage source PWM converter are presented. The calculation of compensation current is performed by DSP within 50 usec. And the Pl control of current is performed by analog devices. The compensations of harmonic current in rectifier loads and unbalance currents are proved by experiments.

  • PDF

High Frequency Electronic Ballast with High Efficiency and High Power Factor (고효율 고역률 고주파 전자식 안정기)

  • You, Wan-Sik;Moon, Tae-Hwan;Kim, Hee-Jun;Cho, Kyu-Min
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1110-1112
    • /
    • 2001
  • This paper presents a high frequency electronic ballast with high efficiency and high power factor. The proposed ballast have driven by the half bridge inverter which is linked diode rectifier without DC link capacitor. Minimized elements of circuit configurations can make the efficiency of the ballast increase. High input power factor which is up to 0.96 can be achieved and the crest factor of lamp current waveforms is controlled with below 1.75 by using a novel control scheme which has PFM and PWM methods simultaneously. In this paper, the circuit configurations of the proposed ballast and the control schemes are described. The usefulness of the proposed ballast is confirmed with the simulation results.

  • PDF