• Title/Summary/Keyword: PWM 제어

Search Result 1,418, Processing Time 0.031 seconds

A Study on the Step-up DC-DC Converter for PV System Application Under Variable Input Voltage Condition (가변 입력 전압 조건하에서 태양광 시스템 적용을 위한 승압형 DC-DC 컨버터 연구)

  • Ju-Yeop Lee;Se-Cheon Oh;Il-Hyeong Jo;Ye-Jin Kim;Yun-Seok Ko
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.4
    • /
    • pp.677-684
    • /
    • 2024
  • In this paper, the design method of a step-up DC-DC converter based on PWM control was studied for solar power system application. The operating principle of the switching mode step-up type DC-DC converter was analyzed and the basic design method was studied. For photovoltaic system application, an output voltage feedback control algorithm based on PWM control was developed to enable the converter's output voltage to follow the target voltage under variable input conditions. As a procedure to verify the effectiveness of the proposed algorithm, a prototype of a step-up DC-DC converter with a single feedback output voltage was designed and made by boosting the input voltage DC 10V to DC 30V. In experiments with prototypes, it was confirmed that the output voltage of the oscilloscope and LCD accurately followed the target output voltage. In the performance evaluation test, it was confirmed that the output voltage of the oscilloscope and LCD accurately followed the target output voltage by showing an error rate within 1 [%] of the reference voltage.

PI Type Decoupling Control Scheme for PWM Converters (PWM 컨버터의 PI Type 비간섭 제어)

  • Lim, Sun-Kyoung;Jung, Jin-Hwan;Nam, Kwang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2062-2065
    • /
    • 1997
  • 컨버터나 인버터의 운전에 있어서 비간섭 전류제어는 그 시스템의 성능에 직접적으로 영향을 주는 중요한 요인이다. 하지만 일반적인 비간섭 제어방식은 모터나 입력 인덕터에 파리미터 오차가 있으면 잘 동작하지 않는다 이 논문에서는 PI 형태의 새로운 비간섭제어 방식을 제안하였다. 이 방식의 가장 큰 장점은 파라미터 오차에 대해 강인성을 가지는 것이다. 시뮬레이션을 통하여 제안된 제어기의 성능을 살펴보았다.

  • PDF

Control of a Single-Phase PWM Converter under Distorted Source Voltage (왜곡된 전원 전압 하에서 단상 PWM 컨버터의 제어기법)

  • Ahn, Chang-Heon;Kim, Sang-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.19-20
    • /
    • 2014
  • 본 논문에서는 왜곡된 단상 전원 전압 하에서도 교류 입력 전류를 정현적으로 제어할 수 있도록 하는 제어기법을 제안하였다. 단상의 물리량을 가상의 삼상 물리량으로 변환하여 이를 d-q축 동기좌표계로 변환된 물리량으로 제어하는 동기좌표계 전류제어기법을 적용하였으며, 왜곡된 전원 전압에 의한 왜곡된 위상각 성분을 추출하여 이를 d-q축 동기좌표계 지령전류에 보상하는 방법을 제안하였다. 제안한 기법으로 왜곡된 전원 전압 하에서도 교류 입력 전류의 고조파를 5%이내로 제한할 수 있음을 시뮬레이션을 통하여 확인하였다.

  • PDF

초고속복합분자펌프 제어기 개발

  • O, Hyeong-Rok;Lee, In-Chan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.99-99
    • /
    • 2012
  • 본 개발에서는 초고속복합분자펌프 구동을 위한 디지털 구동장치를 설계하였다. BLDC구동을 위한 디지털 제어 시스템의 핵심제어 보드 설계 및 모듈 설계를 하여 보드제작 및 기본성능평가를 하고 고속 회전 실험을 하였다. AMB제어기는 넓은 제어대역폭을 확보하기 위하여 FPGA 1개와 마이크로 콘트롤러 2개를 사용하여 구성하였으며 FPGA로 AMB구동을 위한 PWM기능과 CPU 2개의 원활한 Data 통신을 위하여 Dual Memory을 구현하였으며 PWM의 디지털노이즈 회피를 위하여 AMB구동용 PWM과 동기화하여 Gap Sensor 및 전류센서신호 샘플링할 수 있도록 ADC를 구동 및 샘플링한다. 그리고 Gap Sensor 구동 회로와 제어기회로를 하나의 보드로 구연하였다.

  • PDF

Battery charger for PHEV using AC-DC PWM buck converter (AC-DC PWM Buck 컨버터를 이용한 PHEV용 배터리 충전장치)

  • Park, Sang-Hoon;Kim, Keun-Young;Lee, Seung-Kyung;Won, Chung-Yuen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.319-321
    • /
    • 2009
  • 일반적으로 가장 간단한 구조의 배터리 충전장치는 교류를 직류로 변환하기 위한 다이오드 정류기와 직류의 크기를 변환하기 위한 컨버터로 구성되어 있다. 하지만, 이러한 구조로 되어있는 충전장치의 경우 입력단 역률저하로 인하여 전력변환장치에 과도전류나 파형의 왜곡 현상 등을 초래하게 되고, 정류기와 컨버터로 구성되는 2단 전력변환구조이기 때문에 효율에도 좋지 않은 영향을 미치게 된다. 따라서 본 논문에서는 역률제어가 가능한 단일 컨버터 구조를 갖는 플러그인 하이브리드 전기자동차용 42V 배터리 충전장치를 연구하였다. 본 논문에서 연구한 배터리 충전장치는 PWM 방식의 AC-DC Buck 컨버터를 이용한 전력 변환장치와 입력단 역률제어 및 컨버터 출력을 제어하기위한 제어기로 구성되어있다. 본 논문에서 연구한 배터리 충전장치는 시뮬레이션을 통하여 역률제어 및 컨버터 출력을 확인하고 그 타당성을 검토하였다.

  • PDF

Battery charging system Using Parallel Operation Control Technique. (병렬운전 제어기법을 적용한 베터리 충전 장치)

  • Yoon, Ju-Houc;Lee, Jong-Hun;Kim, Hong-Min;Ahn, Jin-Woo;Lee, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.365-366
    • /
    • 2010
  • 본 논문은 큰 용량의 배터리 충전을 위해 PWM 인버터 방식을 적용한 개별 전원장치를 병렬로 구성하여 제어하는 방식을 제안한다. 대용량의 단일 전원장치는 전력소자의 정격으로 인해 사이리스터를 사용하게 되고, 이와같은 방법은 급격한 부하 변동에 대해 응답성이 낮고 대용량의 파워필터를 사용해야 하는 단점이 발생한다. PWM 인버터 기술을 적용한 개별 전원장치를 병렬로 구성하여 제어하게 되면, 위 단점을 해소할 수 있게 되고, 전부하 영역에서 고효율의 안정적인 제어 운전이 가능하다. 제안된 방식은 PWM 인버터와 변압기 및 전력 필터로 구성하였고, 별도의 병렬 제어기가 없이 부하 전류의 분담이 가능하도록 설계 하였다.

  • PDF

Implementation of SVPWM Module for the Multi-Motor Control (다중모터 제어를 위한 SVPWM 모듈의 구현)

  • Ha, Dong-Hyun;Hyun, Dong-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.124-129
    • /
    • 2009
  • Recently, PWM inverter is widely utilized for many industrial applications such as high performance drive and space vector pulse width modulation(SVPWM) inverter which has high voltage ratio and low harmonics compared to conventional PWM inverter. This paper presents the implementation on a field programmable gate array(FPGA) of a SVPWM module for a voltage source inverter. The SVPWM module consists of PWM generator, current and position sensor interface and dead time compensator. The implemented SVPWM module can be integrated with a digital signal processor(DSP) to provide a flexible and effective solution for high performance voltage source inverter and for the use of multi-motor control. The performance of SVPWM module is verified by simulation and several experimental results.

Analysis of a Three Phase PWM AC/DC Converter With Input Current Waveform and Power Factor Correction (입력 전류 파형과 역률 개선 제어기법에 의한 3상 PWM 컨버터 해석)

  • 이수흠;배영호;최종수;백종현
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.93-102
    • /
    • 1998
  • This paper describes to control system for AC to DC converter which has been widely used to power source in industrial factory and domestics. In this paper, three-phase PWM AC to DC Boost converter that operates with unity power factor and sinusodial input line currents is presented. The current control of this converter is based on the predicted current control strategy with fixed switching frequency and the line currents track to reference currents within one sampling time interval. By using this control strategy low ripples in the output current and the voltage as well as fast dynamic response are achieved with small dc link capacitance employed.ployed.

  • PDF

Zero-Transient Current Control Method for PWM Dimming of LED (LED의 펄스폭 변조를 통한 휘도조절시 과도구간이 존재하지 않는 전류 제어 기법)

  • Yoon, Young-Nam;Lee, Sang-Hyun;Cho, Sang-Ho;Hong, Sung-Soo;Kim, Chang-Sub;Lee, Hyo-Bum;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.64-70
    • /
    • 2011
  • This paper presents a zero-transient current control method for PWM dimming of LED. Since the proposed LED current control method has no transient state, it features a high resolution, high linearity, and no current overshoot through LED along a wide dimming range. The operational principles of the proposed LED current control circuit are presented. To confirm the validity of the proposed method experimental results from a prototype circuit of the 46-inch LCD TV are given.

New Optimal PWM Scheme for Minimizing the Harmonic Effects of VSI-PWM Inverter (VSI-PWM 인버터의 고주파 영향을 최소화하기 위한 새로운 Optimal PWM 방식)

  • 이윤종;이일형;정동화
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.15 no.11
    • /
    • pp.886-897
    • /
    • 1990
  • This paper is proposed new optimal PWM scheme is based on a defined linear relationship between the successive pulsewidths of the PWM pattern. The calculation of the pulsewidths in the new PWM scheme is caried out without referring to the equations of CW and MW. With this scheme the PWM pattern for microprocessor controlled inverters can be composed easily by obtaining the optimal increment in sucessive pulsiwidths of the pattern. Furthmore, the harmonic level at the output of PWM inverter are always very low because this PWM pattern is selected on the basis of minimum THD. Theis scheme is applied to 1(Hp), three phase induction motor, and compared with conventional regular PWM scheme. The results of calculations and experiments show that new optimal PWM scheme could provide an effective generalized approach for minimization of harmonics in the VSI-PWM inverter.

  • PDF