Studies of Polymer Matrix Effect for Coextraction Type Anion-Selective Optode and Determination of Thiocyanate in Human Saliva

  • Hong, Young-Ki;Cha, Geun-Sig;Shin, Doo-Soon;Nam, Hak-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.10
    • /
    • pp.836-841
    • /
    • 1994
  • The polymer matrix effect on the selectivity, response rate and reproducibility for coextraction type anion-selective optode membranes were investigated with DOA-plasticized PVC, PVC/hydroxylated PVC, PU/hydroxylated PVC and DOS-plasticized CTA matrices. Optode membranes were prepared with TDMACl and ETH2412 dissolved in one of the four solvent polymeric matrices. The PU/hydroxylated PVC and PVC-based membranes have almost the same selectivity coefficients, while the CTA-based membrane is more selective toward lipophilic anions. The membrane with PU/hydroxylated PVC adhered strongly to a glass surface, and showed highly reproducible and relatively rapid response. Very poor adhesion of PVC/hydroxylated PVC and CTA-based membranes limited the usability of those membranes as sensor components. Based on these results, and considering the biocompatibility for clinical samples, the optode made with PU/hydroxylated PVC was applied to determine the thiocyanate ion in human saliva. The results obtained with this simple device were comparable to those with rather complicated ISE methods.

Gas Permeation Characteristics of PVC/PS Blend Laminated Membranes Prepared by Water Casting (PVC/PS 혼합 수면 전개 적층막의 기체투과 특성)

  • 남석태;최호상;김병식
    • Membrane Journal
    • /
    • v.3 no.3
    • /
    • pp.108-116
    • /
    • 1993
  • In PVC/PS pelyblend laminated membranes, perrneabilities were increased as increasing the blend ratio of PS and selectivities were increased with increasing the blend ratio of PVC. The gas permeation mechanism was shifted from the combination of Poiseuille and Knudsen flow model to the solution-diffusion model as decreasing the PS blend ratio. The structure of polyblend laminated membranes showed series model, where PS rich phase was formed at air side and PVC rich phase was at water side. The model of permeation in the polyblend laminated membranes also showed series model structure.

  • PDF

Reactive modification of PVC membranes for the improved performance

  • Jhaveri, Jainesh H.;Patel, Chetan M.;Murthy, Z.V.P.
    • Membrane and Water Treatment
    • /
    • v.9 no.6
    • /
    • pp.385-392
    • /
    • 2018
  • Poly vinyl chloride (PVC) was chemically modified, and used for ultrafiltration to analyze the performance. Non-solvent induced phase separation (NIPS) method was used to prepare membranes. The neat PVC membrane was casted and used as a control membrane. Modified membrane was prepared by reacting PVC with ethanolamine (EA) in the casting solution (labeled as CM-PVC). Pure water permeability (PWP) was evaluated by measuring pure water flux. Humic acid was used as model foulant solute to analyze flux and rejection ability of membranes. Flux and rejection data of neat and modified membranes were compared to prove the improvement in the filtration performance. The experimental results showed that for PVC and CM-PVC, PWP was calculated to be ~64 and ${\sim}143L/m^2{\cdot}h$, respectively, and the rejection of humic acid was found to be 98% and 100%, respectively. TGA was carried out to analyze the effect of chemical modification on the thermal stability of polymer. FT-IR analysis was another characterization technique used for the comparative study.

In-situ modification of PVC UF membrane by SiO2 sol in the coagulation bath during NIPS process

  • Cheng, Liang;Xu, Zhen-Liang;Yang, Hu;Wei, Yong-Min
    • Membrane and Water Treatment
    • /
    • v.9 no.5
    • /
    • pp.317-325
    • /
    • 2018
  • Polyvinyl chloride (PVC) ultrafiltration (UF) membrane was modified by silica sol in the coagulation bath during non-solvent induced phase separation (NIPS) process. The effects of silica sol concentrations on the morphology, surface property, mechanical strength and separation property of PVC UF membranes were systematically investigated. PVC membranes were characterized by Fourier transform infrared spectroscopy (FTIR), energy dispersive spectroscopy (EDS), scanning electron microscopy (SEM), contact angle goniometry and tensile strength measurement. The results showed that silica had been successfully assembled on the surface of PVC UF membrane. With the increase of silica sol concentration in the coagulation bath, the morphologies of PVC UF membranes changed from cavity structure to finger-like pore structure and asymmetric cross-section structure. The hydrophilicity and permeability of PVC UF membranes were further evaluated. When silica sol concentration was 20 wt.%, the modified PVC membrane exhibited the highest hydrophilicity with a static contact angle of $36.5^{\circ}$ and permeability of $91.8(L{\cdot}m^{-2}{\cdot}h^{-1})$. The structure of self-assemble silica had significant impact on the surface property, morphology, mechanical strength and resultant separation performance of the PVC membranes.

Proton Conducting Composite Membranes Consisting of PVC-g-PSSA Graft Copolymer and Heteropolyacid (PVC-g-PSSA가지형 공중합체와 헤테로폴리산을 이용한 수소이온 전도성 복합 전해질막)

  • Kim, Jong-Hak;Koh, Jong-Kwan;Choi, Jin-Kyu;Yeon, Seung-Hyeon;Ahn, Ik-Sung;Park, Jin-Won
    • Membrane Journal
    • /
    • v.19 no.2
    • /
    • pp.96-103
    • /
    • 2009
  • A series of organic-inorganic composite membranes from poly(vinyl chloride) (PVC) graft copolymer electrolyte and heteropolyacid (HPA) were prepared for proton conducting membranes. First, poly(vinyl chloride)-g-poly(styrene sulfonic acid) (PVC-g-PSSA) was synthesized by atom transfer radical polymerization (ATRP) using direct initiation of the secondary chlorines of PVC. HPA nanoparticles were then incorporated into the PVC-g-PSSA graft copolymer though the hydrogen bonding interactions, as confirmed by FT-IR spectroscopy. The proton conductivity of the composite membranes increased from 0.049 to 0.068 S/cm at room temperature with HPA contents up to 0.3 weight traction of HPA, presumably due to both the intrinsic conductivity of HPA particles and the enhanced acidity of the sulfonic acid of the graft copolymer. The water uptake decreased from 130 to 84% with the increase of HPA contents up to 0.45 of HPA weight traction, resulting from the decrease in number of water absorption sites due to hydrogen bonding interaction between the HPA particles and the polymer matrix. Thermal gravimetric analysis (TGA) demonstrated the enhancement of thermal stabilities of the composite membranes with increasing concentration of HPA.

Comparative Studies on Ammonium Ion Selective Electrodes Using Poly(Vinyl Chloride) and Polyurethane as Substrate Matrix Materials (Poly(Vinyl Chloride)와 Polyurethane을 지지체로 사용한 암모늄이온 선택성 전극의 특성비교)

  • Cho Chang-Ae;Park Su-Moon
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.3
    • /
    • pp.148-154
    • /
    • 2004
  • Ammonium ion selective electrodes have been prepared using nonactin as an ionophore and poly(vinyl chloride) (PVC) or polyurethane(PU) as a polymer matrix with or without a plasticizer, bis(2-ethylhexyl) adipate, and their performances have been evaluated. The reults indicate that PU-based electrodes can be designed to perform better although PVC-based electrodes generally show better performances. In efforts to explain the obervation, we also carried out atomic force microscopy as well as impedance studies, and the results suggests that islands of ion-ophores are formed in the PVC membranes through which ion transfers appear to be more facile than through the PU membranes. The PU membranes appear to have ionophores better dispersed throughout the film and are more resistive to ion mobilities in comparison to PVC films.

Preparation of Proton Conducting Anhydrous Membranes Using Poly(vinyl chloride) Comb-like Copolymer (Poly(vinyl chloride) 빗살형 공중합체를 이용한 무가습 수소이온 전도성 전해질막의 제조)

  • Kim, Jong-Hak;Koh, Joo-Hwan;Seo, Jin-Ah;Ahn, Sung-Hoon;Zeng, Xiaolei
    • Membrane Journal
    • /
    • v.19 no.2
    • /
    • pp.89-95
    • /
    • 2009
  • A comb-like copolymer consisting of a poly(vinyl chloride) backbone and poly(hydroxy ethyl acrylate) side chains, i.e. PVC-g-PHEA, was synthesized through atom transfer radical polymerization (ATRP). This comb-like copolymer was crosslinked with 4,5-imidazole dicarboxylic acid (IDA) via the esterification of the -OH groups of PHEA in the graft copolymer and the -COOH groups of IDA. Upon doping with phosphoric acid (PA, $H_3PO_4$) to form imidazole-PA complexes, the proton conductivity of the membranes continuously increased with increasing PA content. A maximum proton conductivity of 0.011 S/cm was achieved at $100^{\circ}C$ under anhydrous conditions. The PVC-g-PHEA/IDA/PA complex membranes exhibited good mechanical properties, i.e. 575 MPa of Young's modulus, as determined by a universal testing machine (UTM). Thermal gravimetric analysis (TGA) shows that the membranes were thermally stable up to $200^{\circ}C$.

Effect of Surfactants on the Electrochemical Performance of Cation-Selective Membrane Electrodes

  • Oh, Hyun-Joon;Cha, Geun-Sig;Nam, Hak-hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.1
    • /
    • pp.37-44
    • /
    • 2003
  • We examined the effect of polyether-type nonionic surfactants (Brij 35, Triton X-100, Tween 20 and Tween 80) on the potentiometric properties of sodium-, potassium- and calcium-selective membranes which are prepared with widely used ionophores and four kinds of polymer matrices [poly(vinyl chloride) (PVC), polyurethane (PU), PVC/PU blend, and silicone rubber (SR)]. It was found that the PVC-based membranes, which provide the best performance among all other matrix-based membranes in the absence of nonionic surfactants, exhibited larger change in their potentiometric properties when nonionic surfactants are added to the sample solution. On the other hand, the sodium-selective SR-based membrane with calix[4]arene, potassium-selective PVC/PU- or SR-based membrane with valinomycin, and the calcium-selective SR-based membrane with ETH 1001 provide almost identical analytical performance in the presence and absence of Tween 20 or Tween 80 surfactants. The origin of nonionic surfactants effect was also investigated by interpreting the experimental results obtained with various matrices and ionophores. The results suggest that the nonionic surfactant extracted into the membrane phase unselectively form complexes with the primary and interfering ions, resulting in increased background potential and lower binding ability for the ionophore. Such effects should result in deteriorated detection limits, reduced response slopes and lower selectivity for the primary ions.

Minimization of Asymmetry Potential in ETH 129-Based Calcium-Selective Membrane Electrodes

  • 박성배;정사라;차근식;김해동
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.11
    • /
    • pp.1033-1037
    • /
    • 1995
  • PVC-based calcium-selective electrodes doped with ETH 129 usually suffer from a shift in the standard potential when they are in contact with protein-containing solutions (e.g. blood serum) after being calibrated with aqueous standards. The shift is due to the development of asymmetry potential in inherently symmetric PVC membranes through the contamination of outer membrane surface by proteins in the biological samples. Membranes prepared with polyurethane showed much reduced shifts in terms of standard potential. This study was performed with a flow-injection system following a protocol designed to observe minor shifts in baseline potential. Other electrochemical properties of the system, including selectivity and response slope, were similar to those obtained with regular PVC-based ones. PVC-based calcium selective membrane electrodes, doped with commonly used ETH 1001, were also tested to compare their electrochemical performances.

Potentiometric Characteristics of Ion-Selective Electrodes Based on Upper-Rim Calix[4]crown Neutral Carrier

  • 강유라;오현준;이경문;차근식;남학현;백경수;임혜재
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.2
    • /
    • pp.207-211
    • /
    • 1998
  • Potentiometric characteristics of DOS plasticized PVC-based membranes containing upper-rim calix[4]crown neutral carrier to various metal cations and protonated alkylamines have been examined. Although the calix[4]crown-based membrane electrodes exhibited substantial emf responses to alkali and alkaline earth metal cations, their high detection limits (- log[Cs+]=4.5) and sub-Nernstian response slopes (48 mV/pCs+) to the most selective cation, cesium, indicate that the metal cation complexing ability of calix[4]crown is much weaker than that of macrocyclic crown ethers. However, the calix[4]crown-based membrane electrodes exhibited near-Nernstian response slopes (56 mV/decade for hexylNH3+) with low detection limits (log[hexylNH3+]= - 6.7) to most alkylammonium ions compared to those of blank (DOS plasticized PVC membrane with no ionophore) or crown ether-based membranes. While the selectivity patterns of blank and crown ether-based membranes are determined primarily by the lipophilicity of alkylammonium ions, the membranes doped with calix[4]crown ionophore could effectively discriminate the steric shapes of nonpolar alkyl groups of alkylammonium ions.