• Title/Summary/Keyword: PVC plasticizer

Search Result 70, Processing Time 0.02 seconds

Study on Estrogenic Activities of Phthalate Esters Using E-screen Assay and Competitive Binding Assay (E-screen Assay 및 상경적 결합반응을 이용한 Phthalate Esters의 내분비계 장애 작용 연구)

  • 한순영;한상국;문현주;김형식;이동하;김소희;김태성;박귀례
    • Toxicological Research
    • /
    • v.16 no.2
    • /
    • pp.141-146
    • /
    • 2000
  • Phthalate esters are used extensively as a plasticizer in the manufacture of plastic products such as PVC bags and medical devices. Recently, phthalate esters have been shown to induce endocrine system mediated responses. However. only a Jew studies have been conducted for estrogenic activity of phthalate esters. In this study estrogenic activities of seven phthalate esters. butyl benzyl phthalate (BBP), di(2-ethylhexyl) phthalate (DEHP), di-n-butylphthalate (DBP), diethylphthalate (DEP), di-n-pentylphthalate (DPP), di-n-propylphthalate (DPrP) and dicyclohexylphthalate (DCHP), were examined in vitro using E-screen assay and competitive binding assay. From the E-screen assay, BBP. DEHP. DBP and DEP showed weak estrogenic activity at the concentration of 5 $\mu\textrm{M}$. The relative proliferative effect (RPE) and the relative proliferative potency (RPP) were 50~70% and 0.01%. respectively, when compared with 500 pM of 17$\beta$-estradiol (E2). In competitive binding assay with the rat uterine estrogen receptor (ER), BBP and DEP showed weak binding potency [(l/$10^4$~1/$10^5$ of E2] while DEHP and DBP scarcely bound to ER. These results suggest that some phthalate esters have weak estrogenic activities in vitro.

  • PDF

Novel Tm(III) Membrane Sensor Based on 2,2'-Dianiline Disulfide and Its Application for the Fluoride Monitoring of Mouth Wash Preparations

  • Ganjali, Mohammad Reza;Norouzi, Parviz;Tamaddon, Atefeh;Husain, Syed Waqif
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.9
    • /
    • pp.1418-1422
    • /
    • 2006
  • In this work the construction of a novel poly(vinyl chloride) membrane sensor based on 2,2'-dianiline disulfide (DADS) as a neutral carrier, o-nitrophenyloctyl ether (NPOE) as a plasticizer and sodium tetraphenyl borate (NaTPB) as an anionic site with unique selectivity towards Tm(III) ions is reported. The electrode has a linear dynamic range between $1.0\;{\times}\;10^{-6}$ and $1.0\;{\times}\;10^{-2}$ M, with a nice Nernstian slope of 19.5 ${\pm}$ 0.3 mV per decade and a detection limit of $4.0\;{\times}\;10^{-7}$ M at the pH range of 4.8-8.5. It has a very fast response time (<15 s) in the whole concentration range, and can be used for at least 4 weeks without any considerable divergence in the electrode potentials. The proposed sensor revealed comparatively good selectivity with respect to most common metal ions, and especially lanthanide ions. It was used as an indicator electrode in the potentiometric titration of Tm(III) ions with EDTA and in direct determination of concentration of Tm(III) ions in binary mixtures. It was also applied in determination of fluoride ions in mouth wash preparations.

Synthesis of New Aromatic Ester Plasticizers and Their Endocrine Disrupting Screening (새로운 방향족 에스테르계 가소제 합성 및 내분비계 장애성 시험)

  • Yoo, Kyung-Ho;Ryu, Jae-Chun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.211-218
    • /
    • 2007
  • Based on the Benzoflex (Vesicol Chemical Co.) as PVC plasticizer substituents for Di-n-octyl phthalate (DOP), a series of new aromatic carboxylic acid ester compounds were designed as plasticizers, synthesized, and screened for the endocrine disrupting activity. 2-Hydroxybenzoic acid (1) and 2-methoxybenzoic acid (2) as the commercially available starting materials were reacted with diethylene glycol (3) in the presence of p-toluenesulfonic acid using Dean-Stark column to give diethylene glycol di-(2-hydroxy)benzoate (4, KH01) and diethylene glycol di-(2-methoxy)benzoate (5, KH02), respectively. And diethylene glycol di-(3-pyridinyl) ester (7, KH03) and dipropylene glycol di-(3-pyridinyl) ester (9, KH04) were obtained in high yields by treatment of nicotinoyl chloride (6) with diethylene glycol (3) and dipropylene glycol (8) in the presence of triethylamine as a base. To determine the estrogenic disrupting effect of new synthetic phthalate analogues, E-screen assay method was used. Of these compounds, 4 (KH01) was found to be compound without endocrine disrupting effect.

No Estrogenic Activity of Phthalate Esters in Ovariectomized Rat Uterotrophic Assay (랫드 자궁비대반응시험(Uterotrophic assay)을 이용한 phthalate esters의 에스트로겐성 작용 연구)

  • 한순영;문현주;김형식;김철규;신재호;오세동;장성재;박귀례
    • Biomolecules & Therapeutics
    • /
    • v.8 no.2
    • /
    • pp.147-152
    • /
    • 2000
  • The rodent uterotrophic assay is currently recommended as one of the primary in vivo assays far endocrine disrupting chemicals by the Organization for Economic Cooperation and Development (OECD) and Endocrine Disruptor Screening and Testing Advisory Committee (US EPA EDSTAC). Generally, this assay relies on the rapid increase in uterus and vagina weights when exposed to estrogenic compounds. Phthalate esters have been used extensively as a plasticizer in the manufacture of plastic products such as PVC films and medical devices. Recently, phthalate esters have been shown to induce endocrine system mediated responses. However, a flew studies have been conducted for the screening of their estrogenic activity. In this study the estrogenic activity of seven phthalate esters, butyl benzyl phthalate (BBP), di(2-ethylhexyl) phthalate (DEHP), di-n-butylphthalate (DBP), diethylphthalate (DEP), di-n-pentylphthalate (DPF), di-n-propylphthalate (DPrP) and dicyclohexylphthalate (DCHP), was examined in uterotrophic assay. Phthalate esters dissolved in corn oil were administered to ovariectomized (OVX) female Sprague-Dawley rats by sub-cutaneous injection for three consecutive days. fiats were sacrificed 24h after final treatment, and then uterus and vagina weights were deter mined. All phthalate esters tested in this assay did not change talc uterus and vagina weights at dosage levels up to 200 mg/kg/day treatment. These results demonstrated that phthalate esters did not exhibit estrogenic activity in vivo uterotrophic assay.

  • PDF

Silicone Rubber Blended with Polyurethane as the Matrix for Ion-Selective Membrane Electrodes

  • Lee, Hyun Jung;Rho, Kyung Lae;Kim, Chang Yong;Oh, Bong Kyun;Cha, Geun Sig;Nam, Hakhyun
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.623-630
    • /
    • 1995
  • Silicone rubber-based sodium-selective membranes are developed for solid-state ion sensors. It was shown that the potetiometric performance of SR-based membranes are greatly dependent on the type of neutral carriers employed; among the three ionophores, N,N,N',N'-tetracyclohexyl-1,2-phenylenedioxydiacetamide (ETH 2120), bis[(12-crown-4)methyl]dodecylmethylmalonate (D12C4DMM) and monensin methyl ester (MME), examined, only ETH 2120 was compatible with the SR-based matrix. Addition of about 20 wt% plasticizer to the SR-based matrix provided the resulting membranes with potentiometric properties essentially equivalent to those of the corresponding PVC-based membranes. Owing to the strong adhesive strength of SR-based membranes, the CWEs coated \vith those membranes exhibited long lifetime with conventional electrode-like performance. Blending of PU into the SR matrix increased the lifetime of CWEs from two weeks to one month.

  • PDF

Characteristics of Electrode Potential and AC Impendance of Perchlorate Ion-Selective Electrodes Based on Quaternary Phosphonium Salts in PVC Membranes (제4급 인산염을 이용한 과염소산 이온선택성 PVC막 전극의 전극전위와 AC 임피던스 특성)

  • 안형환
    • Membrane Journal
    • /
    • v.9 no.4
    • /
    • pp.230-239
    • /
    • 1999
  • Perchlorate ion-selective electrodes in PVC membranes that respond linearly to concentration 106 M were developed by incorporating the quaternary phosphonium salts as a canier. The effects of the chemical structure, the contents of canier, the kind of plasticizer and the membrane thickness on electrode characteristics such as the electrode slope, the linear respone range and the detection limit were studied. With this results, the detectable pH range, selectivity coefficients and AC impedance characteristics were compared and investigated. The perchlorate ion substituents of the quaternary phosphonium salts like tetraoctylphosphonium perchlorate (TOPP) , tetraphenylphosphonium perchlorate(TPPP), and tetrabutylphosphonium perchlorate(TBPP) as a canier were used. The electrode characteristics were better in the ascending order of TBPP < TPPP < TOPP, with the increase of carbon chain length of the alkyl group. Dioctylsebacate(OOS) was best as a plasticizer, the canier contents were better with 11.76 wt% and the optimum membrane thickness was 0.19 mm. Under the above condition, the electrode slope was 56.58 mV/$^P{ClO}_4$,the linear response range was $10^{-1}$\times$10^{-6}$ M, the detection limit was 9.66 x $10^{-7}$ M. The performance of electrode was better than Orion electrode. The electrode potential was stable within the pH range from 3 to 11. The order of the selectivity coefficients for the perchlorate ion was sol < F < Br < 1. With the result of impedance spectrum, it was found that the equivalent circuit for the electrode could be expressed by a series combination of solution resistance, parallel circuit consisting of the double layer capacitance and bulk resistance and Warburg impedance. And solution resistance was almost not appeared and Warburg impedance was highly appeared by diffusion. Then Warburg coefficient was 1.32$\times$$10^74 $\Omega$ $\cdot$ ${cm}^2/s^{1/2}$.

  • PDF

The Novel SCN- Ion-selective Electrode Based on the 1-Benzyl-3-(4-nitrophenyl) thio-urea Ionophore

  • Lee, Kyungmi;Kang, Dong Hyeon;Choe, Ju Eun;Yun, Mira;You, Jung-Min;Go, Min Jeong;Lee, Junseong;Jeon, Seungwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.11
    • /
    • pp.3175-3180
    • /
    • 2014
  • A potentiometric sensor based on the 1-benzyl-3-(4-nitrophenyl) thio-urea was synthesized and tested as an ionophore in PVC based membrane sensor towards $SCN^-$ ions. This membrane exhibits a linear stable response over a wide concentration range ($1.0{\times}10^{-5}$ to $1.0{\times}10^{-2}M$) with a slope of -59.2 mV/dec., a detection limit of ${\log}[SCN^-]=-5.05$, and a selectivity coefficient for thiocyanate against perchlorate anion of ${\log}K^{pot}_{SCN^-j}=-0.133$. The selectivity series of the membrane is as follows: $SCN^-$ > $ClO_4{^-}$ > $I^-$ > $NO_3{^-}$ > $HSO_3{^-}$ > $Cl^-$ > $HSO_4{^-}$ > $F^-$ > $CH_3COO^-$ > $HCO_3{^-}$ > $Br^-$ > $H_2PO_4{^-}$ > $SO{_3}^{2-}$ > $SO{_4}^{2-}$ > $CO{_3}^{2-}$. The proposed electrode showed good selectivity and a good response for the $SCN^-$ ion over a wide variety of other anions in pH 6.0 buffer solutions and has a fast response time of about < 5s. The influences of the membrane by pH, ionophore, and plasticizer were studied.

Studies on Genetic Toxicity of Epoxidized Soy Bean Oil (에폭시화 대두유의 유전독성 연구)

  • 한의식;정해관;김종원;박미선;엄미옥;강혁준;민수진;오혜영
    • Journal of Food Hygiene and Safety
    • /
    • v.16 no.2
    • /
    • pp.145-151
    • /
    • 2001
  • EpoxidiBed soy bean oil (ESBO) is a plasticizer of PVC which is being widely used as a gaskets for the lid of glass jars including baby food. Using reverse mutation assay, chromosome aberration test and micronucleus test, ESBO were evaluated the mutagenicity. In the reverse mutation test, ESBO did not induced mutagenicity in Salmonella typhimurium TA98, TA100, TA1535, TA1537, TA102 with and without metabolic activation. In the chromosome aberration test using CHL cells, the results showed no increased structural and numerical aberrations in the concentration of sample producing cytotoxicity with and without metabolic activation. The in vivo induction of micronuclei was measured in polychromatic erythrocytes of bone marrow of young (3weeks old) and adult (6 weeks old) ddY mice of both sex. At 24 hours after treatment with ESBO 20, 10, 5, 2.5 g/B.W. kg/corn oil 10 ml by oral route animals were sacrificed and bone marrow cells were prepared for smear slides. The results showed no increased micronucleated polychromatic erythrocytes regardless of sex and age. It was concluded that water soluble ESBO did not show certain genotoxicity within our studies conducted.

  • PDF

Time Serial Concentration of Phthalate Esters and Bisphenol-A Contaminated from Spring Water Container's Cap and Seal Film

  • Park Chan Koo;Shin Jeong Sik;Kim Min Young;Kim Pan Gyi
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.6
    • /
    • pp.457-466
    • /
    • 2005
  • Industrial plasticizers such as phthalates can induce peroxisome proliferation. A growing concern among environmental and health groups has arisen because phthalates such as di-2-ethy1hexy1 phthalate (DEHP) and DBP may cause hormonal disorders, reproductive toxicity, hepatocellular tumors, genital disorders owing to a capacity to bind estrogen receptors, and a low-dose toxic action during certain periods of fetal development. Phthalate esters are used extensively as a plasticizer for plastic manufacture such as PVC bags and medical devices. This study investigated the effects of leached components from spring water container's cap and seal film. Phthalates, e.g. dimethy1 phthalate (DMP), diethy1 phthalate (DEP), di-n-buty1 phthalate (DBP), benzy1buty1 phthalate (BBP), di-(2-ethy1hexy1) phthalate (DEHP), and bisphenol A (BPA) were measured in the spring water. The bisphenol A was not detected or below the detection limit on the leaching from cap, sealing or spring water. DEHP were detected 90-116 ppb on the leaching from seal after 2 weeks, and 0.48-0.51 ppb from the spring water after I week. BBP were measured from seal within 1 week 25.4-66 ppb and below 0.12 ppb from spring water within 2 days. DMP were detected from seal within 2 weeks 51-68.5 ppb and 0.12 ppb after 2 weeks. DEP were measured from seal within 2 weeks 48.1-141 ppb and the concentrations were increased by the time from 0.10 to 0.31 ppb at spring water. DBP were detected from the seal within 2 weeks 92.3-5100 ppb and the concentration were decreased by the time from 0.24 to 0.10 ppb at spring water. These results indicate that some phthalate esters contaminated with spring water using the intact cap and seal film. It is concluded that the measured levels of phthalates leaching from these materials might in vivo only be slightly less than 1/10 of the LOAEL.

Adverse Reproductive Effects on Plasma Vitellogenin and Sex Steroid Levels, and Gonadosomatic Index in Juvenile Common Carps (Cyprinus carpio) Exposed to 17$\beta$-Estradiol and D-2-Ethylhexyl Phthalate

  • Seo, Jinwon;Park, Kyung-Seo;Moon, Woon-Gi;Lee, Sung-Kyu
    • Proceedings of the Korea Society of Environmental Biology Conference
    • /
    • 2002.11a
    • /
    • pp.141-144
    • /
    • 2002
  • Environmental estrogens are natural or synthetic substances present in the aquatic environment, especially in effluent from sewage treatment. However, the adverse effects of these estrogenic substances on fish reproduction are unknown. Di-2-ethylhexyl phthalate (DEHP) is the most common phthalate, which Ps used as a plasticizer in polyvinylchloride (PVC), and it is widespread in the environment and has been found in aquatic organisms and sediments. Therefore, juvenile common carps (Cyprinus carpio) were exposed to nominal concentrations of 17$\beta$-estradiol (E2) (0.5, 5, 50 $\mu\textrm{g}$/L) and DEHP (10, 100, 500 $\mu\textrm{g}$/L) for 21 days, to determine the adverse reproductive effects of these compounds on plasma vitellogenin (VTG) induction, sex steroid level, and gonad weight. Electrophoresis (SDS-PAGE) revealed that much of VTG was induced in fish exposed to 5 and 50 E$_2$ $\mu\textrm{g}$/L, but none of DEHP exposure showed induction. Enzyme-linked immunosorbent assay (ELISA) revealed that VTG was significantly induced in fish exposed to 5 and 50 E$_2$ $\mu\textrm{g}$/L, and combination of 50 E$_2$ $\mu\textrm{g}$/L with 10 and 500 DEHP $\mu\textrm{g}$/L, but none of DEHP exposure showed induction. Analysis of sex steroid levels in some fish revealed that testosterone (T) was detected in both male and female fish of the control and DEHP exposures, but none of fish exposed to 22 concentrations had detectable testosterone level. On the other hand, E$_2$ exposure induced 17$\beta$-estradiol in plasma of male fish, but there was no induction of 17$\beta$-estradiol in plasma of male fish exposed to DEHP. Comparison of gonadosomatic index (GSI) revealed that maximal E$_2$ exposure inhibited ovarian growth, but maximal DEHP exposure stimulated testicular growth. The results indicated that those comparisons can be a useful bio-indicator for determining adverse reproductive effect of endocrine disrupting chemicals (EDCs).

  • PDF