• Title/Summary/Keyword: PV.1

Search Result 1,008, Processing Time 0.027 seconds

Effect of Cultivars, Sowing Date and Cropping System on the Development of Soybean Bacterial Pustule in the Field (콩 품종, 파종시기 및 작부체계가 콩 불마름병 발생에 미치는 영향)

  • Hong, Sung-Jun;Kim, Yong-Ki;Shim, Chang-Ki;Kim, Min-Jeong;Park, Jong-Ho;Han, Eun-Jung;Jee, Hyeong-Jin
    • Korean Journal of Organic Agriculture
    • /
    • v.22 no.4
    • /
    • pp.773-787
    • /
    • 2014
  • Bacterial pustule of soybean caused by Xanthomonas axonopodis pv. glycines is one of the most prevalent bacterial diseases in many areas where soybeans are grown. This study was carried out to evaluate the effect of cultivars, sowing date and cropping system on the suppression of soybean bacterial pustule in the field. One hundred soybean cultivars were screened for disease resistance against bacterial pustule in naturally infested field. Among them, fourteen cultivars including 'Pureun' were found to be high resistant. And thirty cultivars showed to be moderate resistant(less than 3% of diseased leaf area). When Soybean cultivar 'Taekwang' were sown in four different dates, May 25, June 5, June 15, and June 25, at 10 day-interval in Milyang, the diseased leaf area of bacterial pustule was 23.3%-25.7%, 14.7%-18.0%, 10.7%-12.8%, and 1.0%-2.7%, respectively. The lowest percentage of diseased leaf area was recorded in the plots sown on June 25, whereas the highest percentage of diseased leaf area was recorded in the plot sown on May 25. As sowing time was delayed, incidence of soybean bacterial pustule found to be comparatively reduced. From December in 2006 to June in 2007, we surveyed the pathogen population of soybean bacterial pustule in five cropping upland soils where soybean was cultivated. The survey result showed the bacterial pustule pathogens were detected from the all cropping soils. The pathogen populations of soybean bacterial pustule in soybean-barley and soybean-garlic cropping soil were significantly lower than that of the other cropping soils. In addition, the incidence of soybean bacterial pustule was decreased under the two cropping systems.

Economic Evaluation of Unused Space PV System Using the RETScreen Model - A Case Study of Busan, Gangseo-gu - (RETScreen 기반 유휴공간 태양광 발전 시스템의 경제성 평가 연구 - 부산시 강서구 사례를 중심으로 -)

  • Kang, Seongmin;Jeon, Youngjae;Cho, Sung Heum;Lee, Daekyeom;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.8 no.1
    • /
    • pp.21-30
    • /
    • 2017
  • Recently, There has been much discussed about unused space. This space can be used in a variety of ways. Utilizing it as a facility, craft shop, and utilizing renewable energy generation facilities. Especially, in terms of climate change should be supplied renewable energy. Renewable energy needs to be developed in terms of responding to climate change, and the recent Paris agreement is also emphasizing the importance of renewable energy. In particular, renewable energy needs to be widely disseminated. And renewable energy is limited space. In this regard, idle land can provide opportunities for securing new renewable energy generation facilities. The introduction of new and renewable energy facilities in idle space can enhance the self-sufficiency rate of the local community, which is significant in terms of responding to climate. In this study, to investigate the possibility of utilizing a unused space for a photovoltaic power generation facility, we investigated the amount of electricity which could be generated through photovoltaic power generation, and the economic effects, using a RETScreen model. The results showed that 9,738 MWh of power can be generated and that $4,540tCO_2eqcan$ be saved. Regarding the economic effect, the net present value of the facility was shown to be 2,247,389,020 KRW. As the net present value was shown to be positive, we believe that the installation of a photovoltaic power generation facility in an unused space would have a positive economic effect. We found the net present value following the fluctuation of the SMP price to be positive, though there was some variation. However, as the economic efficiency was shown to be low because the net present value in relation to the maintenance costs was negative, we believe that maintenance costs must be taken fully into account when evaluating economic efficiency. In particular, as subsidies can be used to cover maintenance costs which must be factored into photovoltaic power generation, we believe that photovoltaic power generation can have an economic effect. Because spaces not currently in use can have a positive economic effect as renewable energy power generation facilities, and can also contribute to the reduction of greenhouse gas emissions, unused spaces are thought to greatly help local governments to cope with climate change as well as reinforcing their related capabilities. We believe our study will help local governments with decisions relating to unused real estate utilization in the future.

Identification of Quantitative Trait Loci Associated with Resistance to Bacterial Pustule (Xanthomonas axonopodis pv. glycines) in Soybean (SSR 분자표지이용 콩 불마름병 저항성 관여 양적형질 유전자좌(QTL) 분석)

  • Seo, MinJung;Kang, Sung-Taeg;Moon, Jung-Kyung;Lee, Seukki;Kim, Yul-Ho;Jeong, Kwang-Ho;Yun, Hong-Tae
    • Korean Journal of Breeding Science
    • /
    • v.41 no.4
    • /
    • pp.456-462
    • /
    • 2009
  • Bacterial pustule (BP), caused by Xanthomonas axonopodis pv. glycines, is prevalent disease in major soybean production areas. BP can reduce seed yield as well as seed quality. To identify the genomic region associated with the resistance to BP, QTL analysis was conducted using $F_{10}$ RIL (recombinant inbred lines) population, Keunolkong${\times}$Shinpaldalkong. Four QTLs for BP disease were identified on the linkage group B2, D2, I and K in field accounts for 36.4% of the phenotypic variation. Especially, QTL at near of Satt135 on LG D2 was identified in green house experiment explaining 20.9% of the phenotypic variation was found to be a major QTL conferring BP. One of these QTLs, Satt135 on the LG D2, was also identified in green house experiment. In both field and green house condition, the position of major QTL for BP was detected between Satt135 and Satt397 on the LG D2. The major QTL for BP may be used for minimizing soybean BP through effective marker-assisted selection (MAS).

A Study on the Voltage Stabilization Method of Distribution System Using Battery Energy Storage System and Step Voltage Regulator

  • Kim, Byung-ki;Park, Jae-Beom;Choi, Sung-Sik;Jang, Moon-Seok;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.11-18
    • /
    • 2017
  • In order to maintain customer voltages within the allowable limit($220{\pm}13V$) as much as possible, tap operation strategy of SVR(Step Voltage Regulator) which is located in primary feeder, is widely used for voltage control in the utilities. However, SVR in nature has operation characteristic of the delay time ranging from 30 to 150 sec, and then the compensation of BESS (Battery Energy Storage System) during the delay time is being required because the customer voltages in distribution system may violate the allowable limit during the delay time of SVR. Furthermore, interconnection of PV(Photovoltaic) system could make a difficultly to keep customer voltage within the allowable limit. Therefore, this paper presents an optimal coordination operation algorithm between BESS and SVR based on a conventional LDC (Line Drop Compensation) method which is decided by stochastic approach. Through the modeling of SVR and BESS using the PSCAD/EMTDC, it is confirmed that customer voltages in distribution system can be maintained within the allowable limit.

Fabrication and Test of HTS Flux Pump Combined with Solar Energy System (태양광에너지 시스템이 결합된 HTS 자속펌프의 제작 및 예비실험)

  • Kim, Dae-Wook;Chung, Yoon-Do;Jo, Hyun-Chul;Yoon, Yong-Soo;Kim, Hyun-Ki;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.1
    • /
    • pp.22-26
    • /
    • 2011
  • As new one of superconducting power supplies, we proposed an HTS flux pump utilized a solar energy system. As an eternal electric energy can be converted by the solar system, the solar energy system is promisingly applied as an energy source in the power applications. Especially, since the solar energy system played a role in conventional utility power, total power consumption of the flux pump system are provided by solar energy. That means its operating efficiency is remarkably improved compared with developed flux pumps. A solar energy system is comprised of solar panel, photo-voltaic (PV) controller, converter and battery. The HTS flux pump consists of an electromagnet, two thermal heaters and a Bi-2223 magnet. In this paper, we describe the possibility the fusion technology between superconducting power supply and solar energy system. As a fundamental step, the fabrication, structure and experimental results are explained.

Study and Control of Photovoltaic Water Pumping System

  • Khlifi, Mohamed Arbi
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.117-124
    • /
    • 2016
  • Solar photovoltaic pumping system is one of most important of renewable energy applications especially in rural areas. Besides, the control strategy for standalone solar pumping system based on induction motor and without DC/DC converter has been widely studied and discussed in the literature. This topology is of great concern due its economic issues, especially when a standard frequency converter (SFCs) with scalar control is used instead of a dedicated PV inverter. This paper proposes an external control module to generate SFCs frequency reference in order to ensure both maximum power point tracking (MPPT). We present method of modeling and control of photovoltaic pumping system based centrifugal pump controlled by new improved incremental conductance in order to optimize the price and operation of pumping system this MPPT algorithm have many advantages like can be eliminate proportional integral controller It is a low cost solution since it requires no additional power equipment. The induction motor driven pump that is powered by a solar array is controlled by the indirect field oriented control (IFOC). The effectiveness of the proposed approach is illustrated by simulations carried out under Matlab Software. The experimental results are compared with simulation results.

Renewable energy deployment policy-instruments for Cameroon: Implications on energy security, climate change mitigation and sustainable development

  • Enow-Arrey, Frankline
    • Bulletin of the Korea Photovoltaic Society
    • /
    • v.6 no.1
    • /
    • pp.56-68
    • /
    • 2020
  • Cameroon is a lower middle-income country with a population of 25.87 million inhabitants distributed over a surface area of 475,442 ㎢. Cameroon has very rich potentials in renewable energy resources such as solar energy, wind energy, small hydropower, geothermal energy and biomass. However, renewable energy constitutes less than 0.1% of energy mix of the country. The energy generation mix of Cameroon is dominated by large hydropower and thermal power. Cameroon ratified the Paris Agreement in July 2016 with an ambitious 20% greenhouse gas (GHG) emission reduction. This study attempts to investigate some renewable energy deployment policy-instruments that could enable the country enhance renewable energy deployment, gain energy independence, fulfill Nationally Determined Contribution (NDC) and achieve Sustainable Development Goals. It begins with an analysis of the status of energy sector in Cameroon. It further highlights the importance of renewable energy in mitigating climate change by decarbonizing the energy mix of the country to fulfill NDC and SDGs. Moreover, this study proposes some renewable energy deployment policy-solutions to the government. Solar energy is the most feasible renewable energy source in Cameroon. Feed-in Tariffs (FiT), is the best renewable energy support policy for Cameroon. Finally, this study concludes with some recommendations such as the necessity of building an Energy Storage System as well a renewable energy information and statistics infrastructure.

Resource Use Efficiency of Electricity Sector in the Maldives

  • SHUMAIS, Mohamed
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.1
    • /
    • pp.111-121
    • /
    • 2020
  • The study measures the resource use efficiency of diesel based power generation in the Maldives and analyses factors which influence efficiency levels. Stochastic frontier analysis (SFA) technique is applied to data on 30 plants over two year period from 2016 to 2017. The study finds that technical efficiency scores varies from 0.44 to 0.98 across power plants. About 33 percent of the plants have scores below the mean technical efficiency score of 0.87. Empirical results indicate ownership and use of solar photovoltaic (PV) have an influence on improving efficiency levels. Privately owned power plants in resort islands obtained higher technical efficiency scores compared to public and community owned power plants. This is a significant finding as the first study that used power plants in tourist sector in a comparative study. Size of the power plants was not found significant, but relatively small installed capacities can also be efficient. This finding is important because in many inhabited islands installed capacities remain oversized compared to the load. The benchmarking exercise offers model power plants that are relatively efficient, for other power plants and policy makers in small islands to learn from.

The power quality measurement and analysis of concentrated PV system in LV distribution system (저용량 태양광 발전기가 집중 배치된 저압 계통의 전기품질 측정 및 분석)

  • Chae, Woo-Kyu;Kim, Jae-Un;Yoon, Gi-Gab;Seo, Jung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.78-80
    • /
    • 2006
  • 최근 정부의 '태양광주택 10만호 보급사업'으로 저압계통 연계형 태양광 발전시스템이 배전계통의 곳곳에 도입되었다. 기존에는 주로 저용량 태양광(3kW 내외)이 1대씩 연계되어 계통에 큰 영향을 주지 않았지만, 최근에는 공동주택 등에 30${\sim}$100대씩 집중적으로 도입되고 있어 여러 가지 문제점이 나타나고 있다. 이와 관련하여 본 논문에서는 50kVA 주상변압기 1대에 2.3kW급 태양광 32대가 연계된 지역의 전기품질을 측정하고 그 문제점을 분석하였다. 태양광 주택단지 인입지점에서 측정결과 전압이 250V를 상회하는 경우도 있었으며, 주상변압기 2차 직하는 태양광이 연계된 A상의 경우 B상, C상에 비하여 약 2V높은 전압을 기록하였지만 그 값은 정상 범위였다. 전압 상승 요인의 분석결과 태양광의 연계용량이 변압기의 용량을 크게 초과하였으며 저압선도 상위 규격으로 교체될 필요가 있었다.

  • PDF

Development and Performance Evaluation of Fine Stage for 3-DOF Error Compensation of a Linear Axis (직선 이송축의 3자유도 오차 보정을 위한 미세 구동 스테이지 개발 및 성능 평가)

  • Lee, Jae Chang;Lee, Min Jae;Yang, Seung Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.1
    • /
    • pp.53-58
    • /
    • 2017
  • A fine stage is developed for the 3-DOF error compensation of a linear axis in order to improve the positioning accuracy. This stage is designed as a planar parallel mechanism, and the joints are based on a flexure hinge to achieve ultra-precise positioning. Also, the effect of Abbe's offsets between the measuring and driving coordinate systems is minimized to ensure an exact error compensation. The mode shapes of the designed stage are analyzed to verify the desired 3-DOF motions, and the workspace and displacement of a piezoelectric actuator (PZT) for compensation are analyzed using forward and inverse kinematics. The 3-DOF error of a linear axis is measured and compensated by using the developed fine stage. A marked improvement is observed compared to the results obtained without error compensation. The peak-to-valley (PV) values of the positional and rotational errors are reduced by 92.6% and 91.3%, respectively.