• 제목/요약/키워드: PV.1

검색결과 1,004건 처리시간 0.029초

The Development Measuring System of Temperature Effect to Produce Electric Power of Solar Cell

  • Sadmai, Ong-art
    • International journal of advanced smart convergence
    • /
    • 제4권1호
    • /
    • pp.104-113
    • /
    • 2015
  • This paper focuses on a temperature effects on a PV panel which has been installed in Thailand. The main objective is cleaning PV panels and reduce temperature of PV panel by water injects from waterway and experimental results of PV power what it is difference. This project is designed by PLC control system which water injects and control PV temperature, In addition, this project consists of hardware and software such as water pump, water injection and PLC control has been automatically and it can be control system manually. The automatic control system is working when PV temperature rises up over 45 degree Celsius after that the pumping machine would inject water to the surface of PV panels and it must be stop when the PV panel temperature comes down less than 45 degree Celsius. The result of actual experimental found that the control system has been done correctly under specify condition. The experimental has been shown electrical data before and after water injects on PV system found that the electrical power a bit increases and The energy has been taken from PV panel less than energy consumption equipment of control system which taken to operate the water injecting system.

Performance Ratio of Crystalline Si and Triple Junction a-Si Thin Film Photovoltaic Modules for the Application to BIPVs

  • Cha, Hae-Lim;Ko, Jae-Woo;Lim, Jong-Rok;Kim, David-Kwangsoon;Ahn, Hyung-Keun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권1호
    • /
    • pp.30-34
    • /
    • 2017
  • The building integrated photovoltaic system (BIPV) attracts attention with regard to the future of the photovoltaic (PV) industry. It is because one of the promising national and civilian projects in the country. Since land area is limited, there is considerable interest in BIPV systems with a variety of angles and shapes of PV panels. It is therefore expected to be one of the major fields for the PV industry in the future. Since the irradiation is different from each installation angle, the output can be predicted by the angles. This is critical for a PV system to be operated at maximum power and use an efficient design. The development characteristics of tilted angles based on data results obtained via long-term monitoring need to be analyzed. The ratio of the theoretically available and actual outputs is compared with the installation angles of each PV module to provide a suitable PV system for the user.

건물통합형 PV Solar Roof의 통풍효과 실험분석 (Experimental Analysis of Ventilation Effect on the Performance of Building-Integrated PV Solar Roof)

  • 김진희;이강록;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.73-79
    • /
    • 2006
  • The integration of PV modules into building facades or roof could raise PV module temperature that results in the reduction of electrical power generation. Lowering operating temperature of PV module is important in this respect, and PV module temperature should be considered more accurately, for building-integrated PV(BIPV) systems in predicting their performance. This paper describes a BIPV solar roof design and verifies its performance through experiment In relation to the effect of ventilation in space between PV module and roof surface. The results showed that the ventilation in the space had a positive effect in lowering the module temperature of the BIPV solar roof that enhanced the performance of its electricity generation.

한국의 태양광 정책 및 국가 R&D 과제 현황 (Status of Korean Photovoltaic Policy and National R&D Projects)

  • 김희정;방기성;안종득;박진호
    • Current Photovoltaic Research
    • /
    • 제1권1호
    • /
    • pp.1-10
    • /
    • 2013
  • The photovoltaic (PV) industry, which occupies about 80% share of domestic new and renewable energy (NRE) sales, has played an important role in the development of the Korean NRE industry. This was made possible by the government's implementation of the 3rd Basic New and Renewable Energy Plan, which promoted strategic PV R&D, infrastructure building, and a variety of PV deployment programs. For instance, 'One Million Green Homes', 'Feed in Tariff', and 'Renewable Portfolio Standards' programs contributed greatly to the dissemination of PV systems in the country. Furthermore, these programs were supported with more than 380 billion Won over 6 year period (2007~2012). The strategic PV R&D contributed to the fast follow-up in commercial technologies. Because of the recent, sharp decline in PV prices caused by oversupply and economic crisis in European countries, both foreign and domestic PV companies are going through painful restructuring. Under these circumstances, the Korean PV industry needs to find a new strategy for making a breakthrough, and in this sense a proactive role of the Korean government is desperately needed.

Analysis of IEC 61727 Photovoltaic (PV) systems Characteristics of the utility interface

  • Lee, Jeong Hyeon;Yoon, Yong Ho;Kim, Jae Moon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권2호
    • /
    • pp.90-95
    • /
    • 2015
  • This paper describes IEC 61727 standard of Photovoltaic (PV) systems -Characteristics of the utility interface. IEC 61727 standard tests include utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1) voltage, current and frequency, 2) normal voltage operating range, 3) flicker, 4) DC injection, 5) normal frequency operating range, 6) harmonics and 7) waveform distortion, 8) power factor of PV inverter. Also personnel safety and equipment protection part includes test items 1)loss of utility voltage, 2)over/under voltage and frequency, 3)Islanding protection, 4)response to utility recovery, 5)earthing, 6)short circuit protection, 7)Isolation and switching of PV inverter. In this paper, each item of IEC 61727 standard test is studied and analyzed and finally full tested by PV inverter performance function.

Identification and Characterization of Coronatine-Producing Pseudomonas syringae pv. actinidiae

  • Han, Hyo-Shim;Koh, Young-Jin;Hur, Jae-Seoun;Jung, Jae-Sung
    • Journal of Microbiology and Biotechnology
    • /
    • 제13권1호
    • /
    • pp.110-118
    • /
    • 2003
  • Pseudomonas syringae pv. actinidiae strains, which cause canker disease in kiwifruit, were collected from kiwifruit orchards in Korea and identified using biochemical and physiological tests. The nucleotide sequences of the 16s rDNA and 16s-23s internally transcribed spacer of the isolates were found to be Identical to those of' the pathotype strain, Kwl 1, of P syringae pv. actinidiae. Remarkably, no coding sequence for phaseolotoxin biosynthesis or phaseolotoxin- resistant ornithine carbamoyltransferase was found by PCR amplification in any of the new Korean isolates of pseudomonas syringae pv. actinidiae, although this was clearly identified in the control pathotype Kwl 1 reference strain. In contrast, three primer sets derived from the coronatine biosynthetic gene cluster and DNA from the Korean strains yielded amplified DNA fragments of the expected size. A sequence analysis of the PCR products revealed that P. syringae pv. actinidiae and the Korean strains of pv. actinidiae contain coronafncate ligase genes (cfl)with identical sequences, whereas their. corR genes exhibited 91% sequence similarity. The production of coronatine, instead of phaseolotoxin, by the Korean strains of P. syringae pv. actinidiae was confirmed by a bioassay using reference pathovars known to produce coronatine and phaseolotoxin. The genes for coronatine biosynthesis in the Korean strains of P. syringae pv. actinidiae were found to be present on plasmids.

소형 PV 유닛올 위한 원격 태양광 트레킹 시스템 (Remote Sun Tracker for Small-Sized PV Solar Unit)

  • 김기완;김주만;김영인;김병철
    • 융합신호처리학회논문지
    • /
    • 제12권3호
    • /
    • pp.222-227
    • /
    • 2011
  • 2층 트레킹 방식을 적용한 PV 태양광 발전 유닛은 고정형에 비해 동일 면적의 패널로 140% 이상의 발전 출력을 얻을 수 있다는 것이 밝혀져 있다. 그러나 이 방식은 고정형 또는 1축 제어방식에 비해 트레킹 기구가 복잡하고 제어전력이 커서 소 출력 PV 유닛에 있어서는 상대적으로 불리하다. 본 논문에서는 소형 PV 발전유닛의 경제성을 개선하는 방법으로 복수개의 소 출력 PV 유닛을 묶어서 1개소의 중앙제어장치에서 간헐식으로 원격제어 함으로써 각 유닛의 트레킹 관련 기구를 간소화 시키는 동시에 제어전력을 경감 시킬 수 있음을 소개한다. 또한 대규모의 PV 발전 플랜트를 건설하기 어려운 환경에서 적합한 방식으로 활용할 수 있음을 소개한다.

신뢰도를 고려한 태양광시스템의 배전계통 연계 알고리즘에 관한 연구 (A Study on the Algorithm for Interconnection of PV System on Power Distribution System Considering Reliability)

  • 문종필
    • 전기학회논문지P
    • /
    • 제60권4호
    • /
    • pp.241-245
    • /
    • 2011
  • In this paper, when photovoltaic (PV) systems are connected to power distribution system, most effective capacity and connected-point of PV system are presented considering power distribution system reliability. The reliability model of PV system is presented considering the duration of sunshine. Also the model of time-varying load and reliability test system bus2 model are used. To simulate the effects of PV system, various cases are selected; (1) base case which is no connection of PV system to power distribution system when faults are occurred, (2) 3MW case which is 3[MW] connection of PV system (3) 4[MW] case, and (4) 20[MW] case which is 20[MW] connection of PV system to the bus of power distribution system. The capacity limit of connected PV system is settled to 14[MW] for all cases except case 4. The reliability for residential, general, industrial, and educational customer is evaluated.

벼 종자에서 Xanthomonas campestris pv. oryzae의 분리를 위한 선택배지 (A Semiselective Medium for the Isolation of Xanthomonas campestris pv. oryzae from Rice Seed)

  • 김형무;송완엽;소인영;이두구
    • 한국식물병리학회지
    • /
    • 제10권1호
    • /
    • pp.13-17
    • /
    • 1994
  • A semiselective agar medium (XCO) was developed for the isolation of bacterial blight pathogen, Xanthomonas campestris pv. oryzae, from rice seed. The medium contained yeast extract 1.0 g, peptone 2.0 g, sucrose 5.0 g, sodium glutamate 1.0 g, FeSO4.7H2O 0.05 g, Fe.EDTA 1 mg, cephalexin 20 mg, Evan blue (0.1%) 1.5 ml, bromcresol purple (0.1%) 2.5ml, cycloheximide 100 mg and agar 15.0 g per liter. Colonies of X. c. pv. oryzae were 4~5 mm in diameter, smooth, round, blue (darker center) and convex after 6 days incubation at 28$^{\circ}C$. The recovery of 6 isolates of X. c. pv. oryzae on the XOC medium ranged from 81% to 120% (mean 98.2%) in comparison to Wakimoto's medium. The number of saprophytic bacteria from 10 rice seed lots on XCO medium was reduced to 70.4% of that on Wakimoto's medium. The recovery of X. c. pv. oryzae added to rice seed on XOC medium ranged from 67% to 87% (mean 75.6%) of that on Wakimoto's medium.

  • PDF

PV 시스템을 이용한 전기자동차 충전소의 구조시스템 연구 (A Study of Electronic Vehicle Charging Station Structure System Using PV(Photovoltaic) System)

  • 임재휘;윤성원
    • 한국공간구조학회논문집
    • /
    • 제11권1호
    • /
    • pp.105-112
    • /
    • 2011
  • 전기자동차의 상용화시대에 대비한 전기자동차 충전네트워크가 시급해지고 있다. 해외에서는 주차장에 PV시스템을 설치하여 얻어진 전력으로 전기자동차 충전을 할 수 있는 전기자동차 충전소가 설치되어지고 있다. 또한 우리나라에서도 충전인프라 구축방안 및 전기자동차 충전시설 지원기준 등을 설정하여 제시하고 있지만 해외처럼 PV시스템을 이용한 전기자동차 충전소의 사례가 국내에는 없으며, 일반전력을 이용한 전기자동차 충전소만 제시하고 있다. 따라서 본 논문에서는 국내의 전기자동차 충전네트워크 구축에 대비하여 국내 외 태양광 주차장과 해외 PV시스템 전기자동차 충전소의 사례를 조사하여 구조시스템, 구조 재료 등을 분석하여 비교 분석한 결과, 해외 PV시스템 전기자동차 충전소의 경우 캔틸레버 구조와 소규모 타입이 많이 설치되었다.