• Title/Summary/Keyword: PV generation system

Search Result 512, Processing Time 0.023 seconds

An Experimental Study of Performance Improvement of Air Type PV/T Collector Units (실험에 의한 공기식 태양광·열 복합 유닛의 성능 비교)

  • Kim, Jin-Hee;Yang, Yeon-Won;Kim, Jun-Tae
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.17-22
    • /
    • 2007
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. The solar collector utilizing these two aspects is called PV/T(photovoltaic/thermal) solar collector. This paper compares the experimental performance of two different types of air type PV/T collector units: the base case of a collector unit with 10cm gap for forced ventilation and the other unit with copper pin attached to PV module to enhance its thermal performance. The experimental results shows that the base case unit had the overall efficiency of 41.9% and the improved unit with copper pin attached to PV module had 50.1% efficiency. For these air type PV/T units, the forced ventilation of the air space improved the electrical performance as well as the thermal performance.

Performance characteristics of building-integrated transparent amorphous silicon PV system for a daylighting application (자연채광용 박막 투광형 BIPV 창호의 발전특성 분석 연구)

  • Yoon, Jong-Ho;Kim, Seok-Ge;Song, Jong-Wha;Lee, Sung-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.280-283
    • /
    • 2007
  • The first grid-connected, building-integrated transparent amorphous silicon photovoltaic installation has been operated since October 2004 in Yongin, Korea. The 2.2kWp transparent PV system was applied to the facade of entrance hall in newly constructed KOLON E&C R&D building. The PV module is a nominal 0.98m ${\times}$ 0.95m, 10% transparent, laminated, amorphous(a-Si) thin-film device rated at 44 Wp per module. To demonstrate the architectural features of thin film PV technologies for daylighting application, transparent PV modules are attached to the building envelope with the form of single glazed window and special point glazing(SPG) frames. Besides power generation, the 10% transmittance of a-Si PV module provides very smooth natural daylight to the entrance hall without any special shading devices for whole year. The installation is fully instrumented and is continuously monitored in order to allow the performance assessment of amorphous silicon PV operating at the prevailing conditions. This paper presents measured power performance data from the first 12 months of operation. For the first year, annual average system specific yield was just 486.4kWh/kWp/year which is almost half of typical amorphous silicon PV output under the best angle and orientation. It should be caused by building orientation and self-shading of adjacent mass. Besides annual power output, various statistical analysis was performed to identify the characteristics of transparent thin film PV system.

  • PDF

An Experimental Study on Relationship Between Temperature Change and Generation Performance of a-Si BIPV Window System (박막 BIPV창의 온도변화와 발전성능 상관관계에 관한 실측연구)

  • Kim, Bit-Na;Yoon, Jong-Ho;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.179-184
    • /
    • 2012
  • This research on building Integrated Photovoltaic System replacing windows and doors with amorphous silicon thin film PV windows and doors installing same exact mount on Mock-up. The windows and doors should be installed in different angle and bearing so that we can analyse the amount of electricity from them. The objective of the research is to evaluate and investigate the relationship between factors(intensity of solar radiation, PV window surface temperature, incidence angle, and sky conditions) that affects performance of PV window and performance. The range and method of this research is to establish monitoring system and analysis the data from the monitoring system to evaluate the performance of PV windows that have thin film of solar battery. We should evaluate the insolation according to the position of PV window, output, and surface temperature according to months and seasons so that we can figure out the relationship between these. And we should investigate the relationship between performance and efficiency according to incidence angle and sky condition so that we can figure out the correlation between factors and performance.

Performance Analysis of Anti-islanding Function for Grid-connected PV Inverter Systems under Parallel Connections (병렬운전하는 계통연계형 태양광 발전용 인버터의 단독운전 검출 성능 분석)

  • Jung, Young-Seok;Yu, Byung-Gyu;Kang, Gi-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.34-40
    • /
    • 2013
  • Islanding phenomenon of photovoltaic system is undesirable because it leads to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized re-closure. Anti-islanding protection is an important technical requirement for grid-connected PV system. Until now, various anti-islanding methods for detecting and preventing islanding of photovoltaic and other distributed generations have been proposed. Most of them are focusing on the anti-islanding performance of single PV system according to the related international and domestic standard test procedures. There are few studies on the islanding phenomenon for multiple photovoltaic operation in parallel. This paper presents performance analysis of anti-islanding function for grid-connected PV inverter systems when several PV inverters are connected in parallel.

The bidirectional DC module type PCS design for the System Inter Connection PV-ESS of Secure to Expandability (계통 연계 PV-ESS 확장성 확보를 위한 병렬 DC-모듈형 PCS 설계)

  • Hwang, Lark-Hoon;Na, Seung-Kwon;Choi, Byung-Sang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.1
    • /
    • pp.56-69
    • /
    • 2021
  • In this paper, the PV system with a link to the commercial system needs some advantages like small capacity, high power factor, high reliability, low harmonic output, maximum power operation of solar cell, and low cost, etc. as well as the properties of inverter. To transfer the PV energy of photovoltaic power generation system to the system and load, it requires PCS in both directions. The purpose of this paper is to confirm the stable power supply through the load leveling by presenting the PCS considering ESS of photovoltaic power generation. In order to achieve these purpose, 5 step process of operation mode algorithm were used according to the solar insolation amount and load capacity and the controller for charging/ discharging control was designed. For bidirectional and effective energy transfer, the bidirectional converter and battery at DC-link stage were connected and the DC-link voltage and inverter output voltage through the interactive inverter were controlled. In order to prove the validity of the suggested system, the simulation using PSIM was performed and were reviewed for its validity and stability. The 3[kW] PCS was manufactured and its test was conducted in order to check this situation. In addition, the system characteristics suggested through the test results was verified and the PCS system presented in this study was excellent and stronger than that of before system.

The Development of PV-Batttery Driven LED Security Lighting (태양광 배터리 하이브리드 시스템 기반 LED 보안등 개발)

  • Go, Seok-Il;Ahn, Seon-Ju;Park, Byeong-Ha;Choi, Joon-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.433-438
    • /
    • 2012
  • LED is expected as an environmentally friendly next generation light source with its good reliability and long lifetime. In this paper, we propose the PV-Battery Driven LED Security Lighting using the LabVIEW program. The remote monitoring is a program for monitoring the voltage and current that made from PV-Battery Driven LED security lighting in remote area. The main subject of this paper is about making the more useful monitoring program to get and save the data from LED Security Lighting. We develop a prototype of the proposed system.

  • PDF

Operating Performances of PV Energy Generation System with MPPT

  • Oh, Jin-Seok;Kim, Mark-Spatt;Lee, Yun-Hae;Jun, Sang-Tae;Yea, Seung-Hwan;Kim, Byeong-Deok;Lee, Yoon-Sik;Ji-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.479-486
    • /
    • 2003
  • This paper presents the Performance of PV(Photovoltaic) system. the design of MPPT and the battery characteristic. The output power of PV depends on the environmental factors such as insolation and cell temperature. It is proposed that the MPPT is based on an simple power control algorithm. Furthermore the converter has to maintain the optimum duty ratio. A switching strategy of converter for battery may Protect against excessive discharge and overcharge. This paper includes discussion on system reliability power quality and effects of the randomness of the wind and the solar radiation on system design.

A Study on optimal design for installion of 500kWp PV system testing ground (500kW급 태양광시험장 구축을 위한 최적설계에 관한연구)

  • Kim, Eui-Hwan;Jang, Ju-Yeon;Lim, Hee-Chun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.43-48
    • /
    • 2010
  • The performance of photovoltaic systems could be affected by various factors including installing conditions of modules, and their own efficiencies of solar cells and inverters. The installing conditions of a photovoltaic system including array types, tilting angles, azimuth, locations, quantities of sunshine, optimum angles of inclination and separated distance are analyzed using the SolarPro & Minitep SW simulation program, inorder to set up the installing conditions for improving system performance. The result from the simulation of the 500kWp PV system of Kochang with optimal installing conditions compared with normal conditions shows that the capacity factor has been increased from 11.02% to 12.06%.

Influence of High PV Penetration and STATCOM on Rotor Angle Stability of SMIB Transmission System

  • Selwa, FETISSI;Djamel, LABED;Imen, LABED
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.849-857
    • /
    • 2018
  • This paper aims is to study the effect of photovoltaic generation penetration and STATCOM on the transient stability of a single machine infinite bus (SMIB) system based on the rotor angle stability. The influence of STATCOM and PV penetration can be seen through damping oscillations, so that the generator remains stable with the rest of the system for various fault conditions. The simulation results obtained make it possible to efficient identify harmful and beneficial impact of increasing the PV penetration and the existence of STATCOM capability. The system model is created in MATLAB/ SIMULINK software.

A study of on the Efficiency Analysis for 3kW Utility interactive PV System (3kW 태양광발전시스템의 효율분석에 관한 연구)

  • Park, J.M.;Lim, H.W.;Choi, Y.O.;Lee, S.G.;Cho, G.B.;Baek, H.N
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.61-63
    • /
    • 2005
  • Utility interactive photovoltaic systems is one of the most premising applications of photovoltaic systems. These systems are employed in applications where utility service is already available. In this case, there is no need for battery storage because utility power may be used to supplement photovoltaic systems when the load exceeds available PV generation. The load receives electricity from both the photovoltaic array and the utility inter-tied. In this paper, Principle and operating characteristic of Utility Interconnected Photovoltaic System is presented. For the purpose of optimal utility Inter-tied photovoltaic system design and installation. It is that demonstrate throughout the installed 3 PV system respectively, 3kW utility interconnected residential system.

  • PDF