• Title/Summary/Keyword: PTI

Search Result 57, Processing Time 0.026 seconds

The Effect of Coordinative Locomotor Training Using Elastic Bands on the Flexibility and Body Alignment of Elementary School Right-Handed Baseball Players

  • Jeong, Mobeom
    • The Journal of Korean Physical Therapy
    • /
    • v.33 no.5
    • /
    • pp.217-223
    • /
    • 2021
  • Purpose: This study sought to identify the effects of coordinative locomotor training (CLT) using elastic bands on the flexibility and body alignment of right-handed baseball players in elementary school. Methods: The subjects were 20 instructed right-handed baseball players in elementary school. They were classified into the experimental group with 10 players (n=10) to be given coordinative locomotor training using elastic bands and the control group with 10 players (n=10). Flexibility was measured by the sit and reach exercise. Body alignment was measured using formetric 4D method to measure the trunk imbalance angle (TI), trunk torsion angle (TT), pelvic tilt angle (PTi), pelvic torsion angle (PTo), pelvic rotation angle (PR), kyphotic angle (Ky), and lordotic angle (Lo). Results: There was a significant increase in the flexibility within the experimental group (p<0.05). after the intervention. There was also a significant increase in the difference between the experimental group and the control group (p<0.05). There was a significant decrease in PR during body alignment in the experimental group after intervention (p<0.05). An analysis of the differences between groups showed a significant decrease in the PR of the experimental group compared to the control group (p<0.05). Conclusion: These findings show that coordinative locomotor training using elastic bands would be effective for enhancing the flexibility and pelvic rotation of elementary school right-handed baseball players.

Correlation Analysis between Plantar Pressure and Body Alignment According to the Dominant Hand of Elementary School Baseball Players (초등학교 야구선수들의 우세손에 따른 족저압과 신체 정렬간의 상관관계 분석)

  • Jeong, Mo-Beom
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.3
    • /
    • pp.115-121
    • /
    • 2021
  • PURPOSE: This study analyzed the correlation between the plantar pressure and body alignment according to the dominant hand of elementary school baseball players. METHODS: The subjects consisted of 32 elementary school baseball players. The 32 players were classified in the right-hand dominant group (Rt. Group, n = 22) and left-hand dominant group (Lt. group, n = 10). The plantar pressure was measured using a pedoscan to determine the maximum pressure and pressure distribution. The body alignment was measured using a fometric 4D to measure the trunk imbalance angle (TI), pelvic tilt angle (PTi), pelvic torsion angle (PTo), pelvis rotation angle (PR), kyphotic angle (Ky), lordotic angle (Lo), and trunk torsion angle (TT). RESULTS: Participants showed correlations in the Rt. group, according to the left maximum pressure, Lo (r = .592, p < .05), and TT (r = .514, p < .05); according to the right maximum pressure, PR (r = .539, p < .05), and Lo (r = .503, p < .05). In the left pressure distribution, the PR (r = -.521, p < .05) showed a negative correlation. In the Lt. group, the PT (r = -.591, p < .05) showed a negative correlation in the left pressure distribution. CONCLUSION: These results can be used as basic data for a body analysis study of elementary school baseball players in the future.

Novel Design of 8T Ternary SRAM for Low Power Sensor System

  • Jihyeong Yun;Sunmean Kim
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.152-157
    • /
    • 2024
  • In this study, we propose a novel 8T ternary SRAM that can process three logic values (0, 1, and 2) with only two additional transistors, compared with the conventional 6T binary SRAM. The circuit structure consists of positive and negative ternary inverters (PTI and NTI, respectively) with carbon-nanotube field-effect transistors, replacing conventional cross-coupled inverters. In logic '0' or '2,' the proposed SRAM cell operates the same way as conventional binary SRAM. For logic '1,' it works differently as storage nodes on each side retain voltages of VDD/2 and VDD, respectively, using the subthreshold current of two additional transistors. By applying the ternary system, the data capacity increases exponentially as the number of cells increases compared with the 6T binary SRAM, and the proposed design has an 18.87% data density improvement. In addition, the Synopsys HSPICE simulation validates the reduction in static power consumption by 71.4% in the array system. In addition, the static noise margins are above 222 mV, ensuring the stability of the cell operation when VDD is set to 0.9 V.

Transient Stability Analysis using Large-Scale Real Time Digital Simulator

  • Yoon, Yong-Beum;Kim, Tae-Kyun;Won, Jong-Ryul;Shin, Jeong-Hoon;Kim, Yong-Hak;Cha, Seung-Tae;Choo, Jin-Boo
    • KIEE International Transactions on Power Engineering
    • /
    • v.11A no.4
    • /
    • pp.33-38
    • /
    • 2001
  • The KEPS(KEPCO's Enhanced Power system Simulator) Real Time Digital Simulator(RTDS) is the largest real time power system simulator ever built. A power system which includes 320 (3-phase) buses and 90 generators has been modeled and run in real time. Since such large-scale systems were involved, it was not practical to validate them using non-real time electro-magnetic transient programs such as EMTDC™ or EMTP. Instead, the results of the real time electromagnetic transient simulation were validated by comparing to transient stability simulations run using PTI's PSS/E™ program. The comparison of results from the two programs is very good in almost all cases. However, as expected, some differences did exist and were investigated. The differences in the results were primarily traced to the fact that the electromagnetic transient solution algorithm provides more detail solutions and therefore greater accuracy than the transient stability algorithm. After finding very good comparison of results between RTDS Simulator and PSS/E, and after investigating the discrepancies found, KEPCO gained the necessary confidence to use the large-scale real time simulator to analyze and develop their power system.

  • PDF

Finger Mounted Pneumatic Tactile Display and Psychophysical Experiments (손끝 부착 형 공기촉감 제시장치의 개발 및 심리 물리학적 실험)

  • Kim, Yeong-Mi;Oakley, Ian;Ryu, Je-Ha
    • 한국HCI학회:학술대회논문집
    • /
    • 2006.02a
    • /
    • pp.467-473
    • /
    • 2006
  • 가상환경 또는 실제환경에서 정보를 제공하는 햅틱 인터페이스의 필요성이 점점 증가 함에 따라 촉감을 제공 하기 위한 다양한 햅틱 장치가 개발되었고 각 장치의 특성과 성능 평가를 위해 기초적인 정신(심리) 물리학적 연구가 수행 되고 있다. 본 논문에서는 여러 가지 햅틱 인터페이스 중 손가락 끝에 부착하는 형태의 새로운 공기 촉감 제시장치(PTI: Pneumatic Tactile Interface)를 제시하고 이 장치의 유용성을 입증하기 위해 localization rate, 시간 분해능, 길이 분해능, 강도의 세기 등의 심리 물리학적 실험(Psychophysical Experiment) 수행 결과를 제시한다. 공기촉감 시스템은 50개의 출력까지 확장 가능한 공기촉감 하드웨어로 구성 되어있고 손가락 끝에 부착하는 형태로 구성 하기 위해 5*5의 배열의 디스플레이를 제작하였다. 16명의 피실험자가 A, B 두 그룹으로 나뉘어 각각 2가지의 심리물리학 실험을 수행하였다. localization rate의 경우 9개의 다른 자극의 위치를 구별하기 위해 3*3 배열로 구성된 밀집된 디스플레이와 확장된 디스플레이로 측정을 수행하여 각각 58.13%, 85.9%의 localization rate를 얻을 수 있었다. 그리고 100번의 반복 실험을 통해 약 2.6mm의 길이 분해능을 얻을 수 있었고 자극 강도 실험의 경우, 실제의 강도가 세짐에 따라 피 실험 자들이 느끼는 강도의 척도도 증가 하며, 강도가 약해 질수록 피 실험 자들이 느끼는 강도 역시 거의 선형적으로 감소함을 알 수 있었다. 그러나 시간 분해능의 경우에는 시스템을 구성하는 밸브의 성능으로 인해 20ms 이하의 시간 분해능 측정은 제한 되었다. 이러한 심리 물리학 실험을 통하여 개발된 공기촉감 제시장치가 다양한 정보를 전달하는데 충분하다는 결론을 내릴 수 있으며, 제안된 시스템을 사용하는 여러 가지 어플리케이션을 제시하였다.

  • PDF

A novel WD40 protein, BnSWD1, is involved in salt stress in Brassica napus

  • Lee, Sang-Hun;Lee, Jun-Hee;Paek, Kyung-Hee;Kwon, Suk-Yoon;Cho, Hye-Sun;Kim, Shin-Je;Park, Jeong-Mee
    • Plant Biotechnology Reports
    • /
    • v.4 no.2
    • /
    • pp.165-172
    • /
    • 2010
  • Genes that are expressed early in specific response to high salinity conditions were isolated from rapeseed plant (Brassica napus L.) using an mRNA differential display method. Five PCR fragments (DD1.5) were isolated that were induced by, but showed different response kinetics to, 200 mM NaCl. Nucleotide sequence analysis and homology search revealed that the deduced amino sequences of three of the five cDNA fragments showed considerable similarity to those of ${\beta}$-mannosidase (DD1), tomato Pti-6 proteins (DD5), and the tobacco harpin-induced protein hin1 (DD4), respectively. In contrast, the remaining clones, DD3 and DD2, did not correspond to any substantial existing annotation. Using the DD3 fragment as a probe, we isolated a full-length cDNA clone from the cDNA library, which we termed BnSWD1 (Brassica napus salt responsive WD40 1). The predicted amino-acid sequence of BnSWD1 contains eight WD40 repeats and is conserved in all eukaryotes. Notably, the BnSWD1 gene is expressed at high levels under salt-stress conditions. Furthermore, we found that BnSWD1 was upregulated after treatment with abscisic acid, salicylic acid, and methyl jasmonate. Our study suggests that BnSWD1, which is a novel WD40 repeat-containing protein, has a function in salt-stress responses in plants, possibly via abscisic acid-dependent and/or -independent signaling pathways.

Optimal Control of Voltage and Reactive Power in Local Area Using Genetic Algorithm (유전알고리즘을 이용한 지역계통의 전압 및 무효전력 최적제어)

  • 김종율;김학만;남기영
    • Journal of Energy Engineering
    • /
    • v.12 no.1
    • /
    • pp.42-48
    • /
    • 2003
  • In system planing and operation, voltage and reactive power control is very important. The voltage deviation and system losses can be reduced through control of reactive power sources. In general, there are several different reactive power sources, we used switched shunt capacitor to improve the voltage profile and to reduce system losses. Since there are many switched shunt capacitors in power system, so it if necessary to coordinate these switched shunt capacitors. In this study, Genetic Algorithm (GA) is used to find optimal coordination of switched shunt capacitors in a local area of power system. In case study, the effectiveness of the proposed method is demonstrated in KEPCO's power system. The simulation is performed by PSS/E and the results of simulation are compared with sensitivity method.

Responses of self-anchored suspension bridge to sudden breakage of hangers

  • Qiu, Wenliang;Jiang, Meng;Zhang, Zhe
    • Structural Engineering and Mechanics
    • /
    • v.50 no.2
    • /
    • pp.241-255
    • /
    • 2014
  • The girder of self-anchored suspension bridge is subjected to large compression force applied by main cables. So, serious damage of the girder due to breakage of hangers may cause collapse of the whole bridge. With the time increasing, the hangers may break suddenly for their resistance capacities decrease due to corrosion. Using nonlinear static and dynamic analysis methods and adopting 3D finite element model, the responses of a concrete self-anchored suspension bridge to sudden breakage of hangers are studied in this paper. The results show that the sudden breakage of a hanger has significant effects on tensions of the hangers next to the broken hanger, bending and torsion moments of the girder, moments of the towers and reaction forces of the bearings. The results obtained from dynamic analysis method are very different from those obtained from static analysis method. The maximum tension of hanger produced by breakage of a hanger exceeds 2.2 times of its initial value, the maximum dynamic amplification factor reaches 2.54, which is larger than the value of 2.0 recommended for cable-stayed bridge in PTI codes. If two adjacent hangers on the same side of bridge break one after another, the maximum tension of other hangers exceeds 3.0 times of its initial value. If the safety factor adopted to design hanger is too small, or the hangers have been exposed to corrosion, the bridge may collapse due to breakage of two adjacent hangers.

Design and Implementation of POI Service based on Terrestrial-DMB (지상파 DMB 기반의 POI 서비스 설계 및 구현)

  • Jeong, Young-Ho;Kim, Soon-Choul;Cho, Sam-Mo;Kim, Geon;Ahn, Chung-Hyun;Kim, Whan-Woo
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.127-130
    • /
    • 2005
  • 우수한 이동수신 성능을 지닌 지상파 DMB(T-DMB: Terrestrial-Digital Multimedia Broadcasting)의 킬러앱(Killer App)이라 불리는 교통 및 여행정보(TTI: Traffic and Travel Information) 서비스는 주 5일 근무제 실시와 지속적인 자동차수 증가로 인해 그 중요성이 부각되고 있다. 지상파 DMB 기반의 TTI 서비스 전송을 위한 프로토콜로 국제 표준인 TPEG(Transport Protocol Expert Group)이 유력시 되고 있으나, 현재 국제 표준화가 완료된 서비스 규격으로는 속도 ${\cdot}$ 유고정보 및 대중교통수단 관련 정보 전송이 가능한 RTM(Raod Traffic Message)과 PTI(Public Transport Information) 뿐이다. 국내의 경우, 속도 정보 제공을 위한 새로운 서비스 규격으로 CTT(Congestion and Travel Time Information)에 대한 표준화 작업이 진행 중에 있다. 최근 이동통신 인프라 대신 지상파 DMB를 기반으로 한 새로운 위치기반서비스의 규격 제정의 필요성이 대두되었으며, 이에 따라 이를 위한 국내 표준화 활동이 본격적으로 추진될 예정이다. 본 논문에서는 기존 TPEG 규격과 완벽히 호환되는 위치기반서비스 전송을 위한 새로운 POI(Point Of Interest) 프로토콜을 제안하였다. 이의 검증을 위해 POI 데이터 서비스 저작 및 전송서버 및 POI 수신 플랫폼을 설계 ${\cdot}$ 구현하여 송수신 플랫폼을 구성하였으며, 구축된 플랫폼을 이용한 방송실험을 통해 제안된 POI 서비스 응용 프로토콜의 안정성 및 전송 효율성을 확인하였다.

  • PDF

Effect of Modified High-heels on Metatarsal Stress in Female Workers

  • Kim, Kwantae;Peng, Hsien-Te
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.3
    • /
    • pp.197-204
    • /
    • 2019
  • Objective: The purpose of this study was to identify the effect of high-heels (HH) modification on metatarsal stress in female workers. Method: Seven females who work in clothing stores ($heights=160.4{\pm}3.9cm$; $weights=47.4{\pm}4.1kg$; $age=31.3{\pm}11.1yrs$; $HH\;wear\;career=8{\pm}6.5yrs$) wore two types of HH (original and modified). The modified HH had been grooved with 1.5 cm radius and 0.2 cm depth around the first metatarsal area inside of the shoes using the modified shoe-last. Participants were asked to walk for 15 minutes on a treadmill and to stand for 10 minutes with original and modified HH, respectively. Kinetics data were collected by the F-scan in-shoe system. After each test, participants were asked to rate their perceived exertion using the Borg's 15-grade RPE scale and interviewed about their feeling of HH. Nonparametric Wilcoxon signed-rank test and effect size (Cohen's d) were used to determine the difference of the variables of interest between the original and modified HH. Results: In the present study, modified HH of the peak contact pressure of 1st metatarsal (PCP) left, PCP right, pressure time integral (PTI) left, peak pressure gradient (PPG) left during standing and PPG right during walking are greater than original HH. And even it didn't show statistically significant, the average in all pressure values of modified HH showed bigger than original HH. It surmised to be related to awkward with modified HH. Even though they said to feel the comfortable cause of big space inside of HH in the interview, they seemed to be not enough time to adapt with new HH. So their walking and standing postures were unstable. Conclusion: Modified the fore-medial part of HH can reduce the stress in the first metatarsal head and big toe area during standing and walking.