• Title/Summary/Keyword: PSS 검출

Search Result 19, Processing Time 0.027 seconds

Fabrication of TiO2/polyelectrolyte thin film for a methyl mercaptan gas sensor (메칠멜캅탄 가스센서용 TiO2/전해질폴리머 박막 제조)

  • Kim, Jin-Ho;Hwang, Jong-Hee;Lee, Mi-Jai;Kim, Sei-Ki;Lim, Tae-Young
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.5
    • /
    • pp.221-226
    • /
    • 2010
  • Quartz crystal microbalance (QCM) gas sensor to detect methyl mercaptan ($CH_3SH$) gas was fabricated by depositing $TiO_2$ nanoparticles and polyelectrolyte on the electrode of QCM. The $TiO_2$/poly(sodium 4-styrenesulfonate) (PSS) thin film fabricated by a layer-by-layer self-assembly (LBL-SA) method showed a high surface area and increased the sensitivity of gas sensor. When the QCM sensors coated with triethanolamine (TEA) or ($TiO_2$/PSS) were exposed to methyl mercaptan gas (1.0 ppm), the frequency shifts of QCM with TEA casting film and $TiO_2$/PSS thin film were ca. 9 Hz and ca. 24 Hz, respectively. As the bilayer number of ($TiO_2$/PSS) increased, the frequency shift of QCM sensor with ($TiO_2$/PSS) thin film was gradually increased. In addition, the frequency shift of QCM sensor was gradually increased as the concentration of methyl mercaptan gas increased from 0.5 ppm to 2.0 ppm. In this study, the surface morphology and sensor property of QCM sensor coated with ($TiO_2$/PSS) thin film were measured.

A Study on Cell ID Detection Scheme Using Synchronization Signals for 5G NR System (5G NR 시스템을 위한 동기 신호를 이용한 cell ID 검출을 위한 방법 연구)

  • Ahn, Haesung;Cha, Eunyoung;Kim, Hyeongseok;Kim, Jeongchang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2020.07a
    • /
    • pp.593-595
    • /
    • 2020
  • 본 논문에서는 5G NR 시스템을 위한 동기 신호를 이용한 cell ID 검출 방법에 대한 성능을 비교하였다. 5G NR(fifth-generation new radio) 시스템의 송신기는 SS/PBCH (synchronization signal/physical broadcast channel) 블록을 송신하며, 수신기는 수신된 SS/PBCH 블록을 이용하여 주파수 및 타이밍 오프셋 (frequency and timing offset)을 추정 할 수 있으며, cell ID (cell identity)는 PSS (primary synchronization signal)와 SSS (secondary synchronization signal)를 통해 검출할 수 있다. 본 논문에서는 cell ID 를 검출할 수 있는 방법으로서 2-stage 디코딩 방법과 결합 최대우도 결정 규칙 (joint maximum-likelihood decision rule: joint ML) 디코딩 방법을 사용하였다. Joint ML 디코딩 방법은 2-stage 디코딩 방법에 비해 더 좋은 검출 성능을 보이지만, 복잡도 측면에서는 2-stage 디코딩 방법이 joint ML 디코딩 방법에 비해 더 낮은 복잡도를 갖는 것을 확인하였다.

  • PDF

A Study on the Characteristics of New Frequency Controller According to Changing the Frequency Measurement Position of HVDC System (HVDC 시스템의 주파수 신호검출 위치 변경에 따른 새로운 주파수 제어기 특성 연구)

  • Kim Chan-Ki;Han Byoung-Sung;Park Jong-Kwang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.457-467
    • /
    • 2005
  • This paper deals with the new frequency controller of the HVDC scheme linking Haenam to Cheju Island. The primary aim of the study is to develop and evaluate a new frequency controller after the removing of the present synchronous compensators. The simulation methods are the mix of PSCAD/EMTDC and PSS/E, the main system studies are done for the transient state analysis using PSCAD/EMTDC. The study cases are completed involving 3 phase, single phase trip and load tripping events and study plots presented. In conclusion, the new frequency measurement from the AC network gives effective frequency control and dynamic performance.

Performance Evaluation of PBCH Detection of LTE-Based 5G MBMS and 5G NR for Cellular Broadcast (셀룰러 방송을 위한 LTE 기반 5G MBMS와 5G NR의 PBCH 검출 성능 평가)

  • Ahn, Haesung;Kim, Hyeongseok;Cha, Eunyoung;Kim, Jeongchang;Ahn, Seok-Ki;Kwon, Sunhyoung;Park, Sung-Ik;Hur, Namho
    • Journal of Broadcast Engineering
    • /
    • v.26 no.6
    • /
    • pp.766-777
    • /
    • 2021
  • This paper presents an improved scheme for detection of the physical broadcast channel (PBCH) in long-term evolution (LTE)-based fifth-generation (5G) multimedia broadcast and multicast services (MBMS) and 5G new radio (NR) for cellular broadcast. In the time domain, by combining the correlations between the received signal and primary synchronization signal (PSS) within all SS/PBCH blocks, the frame synchronization and the start position of the SS/PBCH blocks can be obtained. In this paper, to improve the detection performance of PBCH for 5G NR, a combining scheme of PBCH signals within a frame is proposed. In addition, the performance of the proposed detection scheme is evaluated and the performance is compared with the conventional scheme for PBCH detection of LTE-based 5G MBMS. The simulation results show that the detection performance of PBCH for 5G NR is improved by combining the PBCH signals and outperforms LTE-based 5G MBMS under the additive white Gaussian noise (AWGN), fixed, and mobile environments.

Voltammetric Sensor Incorporated with Conductive Polymer, Tyrosinase, and Ionic Liquid Electrolyte for Bisphenol F (전도성고분자, 티로시나아제 효소 및 이온성 액체 전해질을 융합한 전압전류법 기반의 비스페놀F 검출 센서)

  • Sung Eun Ji;Sang Hyuk Lee;Hye Jin Lee
    • Applied Chemistry for Engineering
    • /
    • v.34 no.3
    • /
    • pp.258-263
    • /
    • 2023
  • In this study, conductive polymers and the enzyme tyrosinase (Tyr) were deposited on the surface of a screen printed carbon electrode (SPCE), which can be fabricated as a disposable sensor chip, and applied to the detection of bisphenol F (BPF), an endocrine disruptor with proven links to male diseases and thyroid disorders, using electrochemical methods. On the surface of the SPCE working electrode, which was negatively charged by oxygen plasma treatment, a positively charged conductive polymer, poly(diallyldimethyl ammonium chloride) (PDDA), a negatively charged polymer compound, poly(sodium 4-styrenesulfonate) (PSS), and another layer of PDDA were layered by electrostatic attraction in the order of PDDA, PSS, and finally PDDA. Then, a layer of Tyr, which was negatively charged due to pH adjustment to 7.0, was added to create a PDDA-PSS-PDDA-Tyr sensor for BPF. When the electrode sensor is exposed to a BPF solution, which is the substrate and target analyte, 4,4'-methylenebis(cyclohexa-3,5-diene-1,2-dione) is generated by an oxidation reaction with the Tyr enzyme on the electrode surface. The reduction process of the product at 0.1 V (vs. Ag/AgCl) generating 4,4'-methylenebis(benzene-1,2-diol) was measured using cyclic and differential pulse voltammetries, resulting in a change in the peak current with respect to the concentration of BPF. In addition, we compared the detection performance of BPF using an ionic liquid electrolyte as an alternative to phosphate-buffered saline, which has been used in many previous sensing studies. Furthermore, the selectivity of bisphenol S, which acts as an interfering substance with a similar structure to BPF, was investigated. Finally, we demonstrated the practical applicability of the sensor by applying it to analyze the concentration of BPF in real samples prepared in the laboratory.

Optimized Condition of Genomic DNA Extraction and PCR Methods for GMO Detection in Potato (유전자재조합 감자의 검정을 위한 DNA분리 및 PCR검출의 최적조건 탐색)

  • Shin, Weon-Sun;Kim, Myung-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.591-597
    • /
    • 2003
  • To compare the quality of genomic DNA extracted from potato for PCR detection, four different methods, such as silica-based membrane method, silica-coated bead method, STE solution treatment, and CTAB-phenol/chloroform method, were evaluated. Also, to remove an excessive carbohydrate from the potato, ${\alpha}$- and ${\beta}$-amylase were used individually and in combination. When used both silica-based membrane method and silica-coated bead method combined with enzymes, the genomic DNAs were extracted from the raw potato with high purity for PCR. However, the silica-coated head method combined with enzyme treatment was the most efficient for extraction of the genomic DNA from the frozen fried potatoes. When applied with STE solution, the highly purified DNA was extracted from the raw potatoes without enzyme treatment in adequate yield for PCR. In cases of processed potatoes, such as frozen-fried potato and fabricated potato chips, CTAB-phenol/chloroform method is mostly feasible for DNA extraction and PCR efficacy at high sensitivity. As the results of PCR amplification, 216bp of PCR product was detected on 2% agarose gel electrophoresis, but any amplicons derived from New leaf and New leaf Y gene was not detected in any sample.

Development and Application of DNA Analysis Method for Identificaion of Main Ingredients in Starch (전분의 주원료 판별을 위한 유전자 분석법 개발 및 적용)

  • Park, Yong-Chjun;Kim, Mi-Ra;Kim, Yong-Sang;Lee, Ho-Yeon;Kim, Kyu-Heon;Lee, Jae-Hwang;Kim, Jae-I;Lee, Sang-Jae;Lee, Hwa-Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.2
    • /
    • pp.181-187
    • /
    • 2013
  • Identification of main ingredients in starches has been investigated using physicochemical analysis method mainly. However, physicochemical properties such as particle size have limitations in determining the differences among mixed starches. Therefore, we developed a molecular biological method to identify materials used in starch, as a sample, 11 kinds of starches including sweet potato starch, potato starch, corn starch, and tapioca starch. DNeasy plant mini kit, magnetic DNA purification system, and CTAB methods were used to extract DNA from samples. After gene extraction, whole genome amplification (WGA) was performed to amplify the extracted DNA. Species-specific primers were used as followings: ib-286-F/ib-286-R (105 bp), Pss 01n-5'/Pss 01n-3' (216 bp), SS11b 3-5'/SS11b 3-3' (114 bp), and SSRY26-F/SSRY26-R (121 bp) gene for sweet potato, potato, corn, and tapioca, respectively. In this study, we could confirm the main ingredients using WGA and PCR method.

Enhanced Sensitivity of PEDOT Microtubule Electrode to Hydrogen Peroxide by Treatment with Gold (금 처리를 통한 PEDOT 마이크로튜브 전극의 과산화수소 검출 특성 향상)

  • Park, Jongseo;Son, Yongkeun
    • Polymer(Korea)
    • /
    • v.38 no.6
    • /
    • pp.809-814
    • /
    • 2014
  • An array structure of conducting polymer microtubule was fabricated for an amperometric biosensor. 3,4-Ethylenedioxythiophene (EDOT) was electropolymerized in the microporous template membrane with poly(3,4-ethylenedioxythiophene)/poly(4-styrenesulfonic acid) (PEDOT/PSS) composite as a binder. The array structure can provide enhanced current collecting capability due to large active surface area compared to the macroscopic area of the electrode itself. For a biosensor application, the array electrode was tested for $H_2O_2$ detection and showed very sluggish electrochemical response to $H_2O_2$. To enhance the detection efficiency to the oxidation of $H_2O_2$, gold was treated on the electrode by two different approaches: sputtering and electrochemical deposition. Gold treatment with either method greatly enhanced the sensitivity of the electrode to $H_2O_2$. So, conducting polymer microtubule array with gold treatment was expected to be a sensitive amperometric biosensor system based on the detection of $H_2O_2$.

On-Site Diagnosis of Fire Blight with Antibody-Based Diagnostic Strips (항혈청 기반 진단 스트립을 이용한 과수 화상병 현장진단)

  • Heo, Gwang-Il;Shin, Doo-San;Son, Soo-Hyeong;Oh, Chang-Sik;Park, Duck Hwan;Lee, Young-Kee;Cha, Jae-Soon
    • Research in Plant Disease
    • /
    • v.23 no.4
    • /
    • pp.306-313
    • /
    • 2017
  • Recently fire blight occurred in the Republic of Korea and eradication program for the disease has been executed since then. Specificity and detection sensitivity of the 2 antibody-based diagnostic strips to Korean isolates of Erwinia amylovora (Ea) and their application for on-site diagnosis were evaluated in this study. Ea AgriStrip, a commercial diagnostic kit, and EB strip, developed in this study, reacted positively to the all tested Korean Ea strains and also to most of Erwinia pyrifoliae (Ep) strains causing black shoot blight. They reacted negatively to all Pusedomonas syringae pv. syringae (Pss) strains that cause shoot blight on apple. Detection sensitivity was similar between the 2 strips. For on-site diagnosis, the two strips reacted positively only to the extractions of the fire-blighted samples on all fire blight occurred orchards except one orchard at which on-site diagnosis was carried out at winter time. In addition, they reacted positively to the black-shoot blighted extractions from the black shoot blight occurred apple orchard. These results suggest that both EB strip and Ea AgriStrip would be useful for on-site diagnosis of fire blight in Korea.