• Title/Summary/Keyword: PSF

Search Result 275, Processing Time 0.028 seconds

What are the Differences in Outcome among Various Fusion Methods of the Lumbar Spine?

  • Kang, Suk-Hyung;Kim, Young-Baeg;Park, Seung-Won;Hong, Hyun-Jong;Min, Byung-Kook
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.1
    • /
    • pp.39-43
    • /
    • 2005
  • Objective: For Posterior lumbar interbody fusion(PLIF) various cages or iliac bone dowels are used with or without pedicle screw fixation(PSF). To evaluate and compare the clinical and radiological results of different fusion methods, we intend to verify the effect of added PSF on PLIF, the effect of bone cages and several factors which are thought to be related with the postoperative prognosis. Methods: One hundred and ninety seven patients with lumbar spinal stenosis and instability or spondylolisthesis underwent various fusion operations from May 1993 to May 2003. The patients were divided into five groups, group A (PLIF with autologous bone dowels, N=24), group B (PLIF with bone cages, N=13), group C (PLIF with bone dowels and PSF, N=37), group D (PLIF with bone cages and PSF, N=30) and group E (PSF with intertransverse bone graft, N=93) for comparison and analyzed for the outcome and fusion rate. Results: Outcome was not significantly different among the five groups. In intervertebral height (IVH) changes between pre- and post-operation, Group B ($2.42{\pm}2.20mm$) was better than Group A ($-1.33{\pm}2.05mm$). But in the Group C, D and E, the IVH changes were not different statistically. Fusion rate of group C, D was higher than that of Group A and B. But the intervertebral height(IVH) increased significantly in group B($2.42{\pm}2.20mm$). Fusion rate of group C and D were higher than that of group A and D. Conclusion: Intervertebral cages are superior to autologous iliac bone dowels for maintaining intervertebral height in PLIF. The additional pedicle screw fixation seems to stabilize the graft and improve fusion rates.

A Study on Polymeric Membranes for Oxygen-electrode System (산소전극 시스템에 사용되는 고분자막에 관한 연구)

  • 박희영;김현준;정용섭;홍석인
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.04a
    • /
    • pp.52-53
    • /
    • 1995
  • 현재 상용화 되어있는 산소/질소 분리용 고분자 분리막은 비교적 낮은 선택도를 가지고 있다. 즉, 이점은 확산도와 용해도를 조절함으로써 분리막의 투과선택도를 높일 수 있는 가능성을 보여주고 있으며 보다 높은 투과도와 투과선택도를 갖는 새로운 고분자 재료의 선택이 분리막을 통한 기체 분리나 그 상업적 이용에 절실히 요구되고 있다. PSf는 상용성, 화학적 내구력, 강도, 높은 유리전이온도와 우수한 기체투과성질을 가진 고분자로 분리막에 많이 응용되고 있다. Erb 등은 용매로 DMF(dimethylformamide)와 THF(tetrahydrofuran)를 사용하여 막을 제조하였다. 상부 흐름압력이 5atm일때 각 기체의 투과도 계수는, 헬륨이 11, 이산화탄소가 5.5, 메탄이 0.5, 질소가 0.2였으며, PSf막에 대한 각 기체의 투과는 Henry mode보다 Langmuir mode에서 더욱 우세하게 일어난다고 생각하였다. 또한 Ghosal 등은 PSf에 nitro기를 도입한 nitrated PSf의 투과특성을 조사하였다. 실험결과 nitro group이 치환된 PSf막이 nitro group이 없는 막에 비해 투과도는 낮았지만 선택도는 증가하였다. 구조가 다른 여러가지의 PSf막을 통한 기체 투과성질은 Ghem 등에 의해 밝혀졌다. Membrane-covered probes를 이용한 폴라로그램(polarogram) 방법은 산소를 측정하는데 가장 보편적인 방업ㅂ으로, 산소 탐침(oxygen probe)의 원리는 소위 효소 전극을 발전시키는데 이용되어 왔다. 효소전극은 산소와 실험하고자 하는 물질간의 특정한 효소반응에 기초를 둔 다양한 물질의 선택적 측정을 위한 것이다. 이때 센서에 응용되는 합성막은 산소에 대해 선택적인 투과를 해야하며, 상대적으로 높은 산소확산계수와 물에 대해서는 낮은 투과도를 가져야 한다. 높은 산소확산계수는 반응을 빠르게 하는 잇점이 있으며 물에 대한 낮은 투과도는 센서내의 전해질 물질을 유지보호하는 역할을 한다. 분리막이 산소전극에 이용될 경우 높은 산소 확산계수 이외에도 적절한 기계적 강도, 열적 안정성 등이 요구된다.

  • PDF

The Effects of Physical Aging of PSF/AS4 Laminate on Fatigue (PSF/AS4 복합재료의 가속노화가 피로강도에 미치는 영향)

  • Kim, Hyung-Won
    • Composites Research
    • /
    • v.19 no.4
    • /
    • pp.1-6
    • /
    • 2006
  • The effects of aging on fatigue of PSF/AS4 laminates tvas studied using the new energy release rate analysis. The analysis by the variational mechanics has been useful in providing fracture mechanics interpretation of matrix microcracking in cross-ply laminates. This paper describes the changes of the critical energy release rate ${\Delta}Gmc$(microcracking toughness) about the variation of the aging period during fatigue loading. The master plot by modified Pans-law gives a characterization of a material system's resistance to microcrack formation. PSF/AS4 $[0/902]_s$ laminates were aged at four different temperatures based on the glass transition temperature for 60 days. At all temperatures, the toughness decreased with aging time. The decrease of the toughness at higher temperature was faster than at lower temperature. To assess the effects of aging on fatigue, the unaged laminates were compared with the laminates which were aged for 60 days at $170^{\circ}C$ near $180^{\circ}C\;T_g$. The slope of dD/dN versus A 6u, of the aged laminates was lower than that of the unaged laminates. There was a significant shift of the aged data to formation of microcracks at the lower values of ${\Delta}G_m$.

Effect of covering materials on seedling quality of rice (못자리 피복재가 벼의 묘소질에 미치는 영향)

  • Song, Suk-Yeon;Kim, Tae-Heon;Sohn, Jae-Keun
    • Current Research on Agriculture and Life Sciences
    • /
    • v.28
    • /
    • pp.47-52
    • /
    • 2010
  • This study was carried out to investigate the availability of covering material used for raising seedlings in the rice nursery bed. The pre-germinated seeds of a rice cultivar 'Chilbo' were sown into seedling tray ($60{\times}30{\times}2.5cm$) on 20th April and 3rd May 2010. Polypropylene spunbonded fabric (PSF) and lagging were used for covering materials in rice nursery bed. The growth characteristics of seedlings were evaluated at 8, 15 and 25 days after sowing (DAS) in the nursery beds covered with PSF and lagging, respectively. The plant height of 8-day old seedlings grown in lagging nursery bed was longer by 2cm than those in PSF nursery bed when the seeds were sown on 20th April, but seedling quality grown in lagging nursery bed was poor compared with that in PSF nursery bed. The growth characteristics of 15-day old seedlings were similar to that of 8-day old seedlings. The plant height of 8, 15 and 25-day old seedlings grown in lagging nursery was longer than those in PSF nursery when the seeds were sown on 3rd May. The seedling quality grown in PSF nursery was better than that in lagging nursery. The seedlings grown in PSF nursery have more leaves and better seedling quality compared with that of lagging nursery. The seedling quality was remarkably decreased with the increase of nursery period in lagging bed but seedlings quality were recovered at 5 days after hardening treatment by removing the lagging.

  • PDF

Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT (PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가)

  • Choong-Woon Lee;Yeon-Wook You;Jong-Woon Mun;Yun-Cheol Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.47-54
    • /
    • 2023
  • Purpose PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 mm with matrix size 128×128, slice thickness 3.75 mm, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in Wilcoxon signed rank test results (P value<0.001). Conclusion PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

  • PDF

고감도 형광판을 이용한 실시간 IMRT 선량 분석 가능성 연구

  • 고영은;이병용;안승도;이상욱;김종훈;신성수;최은경
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.36-36
    • /
    • 2003
  • 목적 : 고감도 형광판과 필름을 이용하여 실시간으로 선량을 측정하여 IMRT 선량분포를 검증하는데 사용하는 가능성을 알아보고자 하였다. 대상 및 방법 : 본 연구에서 개발한 물팬텀은 지름 25cm 아크릴 원통과 원통의 중앙부분에 삽입되는 고감도 형광판으로 구성되어 있다. 이를 사용하여 dose linearity correction factor를 구하기 위해 dmax 지점에서 6MV x-ray를 고감도형광판에 조사하여 blurring correction factor를 구하였다. CCD를 이용하여 고감도 형광판에서 나오는 영상을 수집하였다. 고감도 형광판에서 수집한 영상의 x축 profile은 RTP에서 얻은 profile과 비교하였고, 이온전리함으로 scanning한 데이터를 이용하여 고감도 형광판과 물에서 빛에 의한 산란선 때문에 발생하는 blurring effect를 교정하였다. 여기서 계산된 blurring effect factor를 고감도 형광판에서 수집된 영상에 적용하였다. 결과 : CCD 카메라는 형광판의 전 영역을 감지할 수 있고, 조사시간은 형광판의 중첩된 영상의 선량에 비례하였다. 물팬텀에서 형광판의 blurring effect 는 가우시안 분포로 표현할 수 있었다. 또한 Deconvolution kernel은 원통 팬텀에서 지름 $\pm$5cm 이내의 범위에 위치하였고, 따라서 형광판 영상으로부터의 실제 선량분 포를 뽑아낼 수 있었다. RTP 에서 계산된 선량분포와 blurring correction factor로 교정한 후 중첩시켜 얻은 고감도 형광판 영상의 선량분포는 일치하였다. 결론 : 정기적인 IMRT 선량 검증에 대한 실시간 선량측정 방법이 개발되었다. 고감도 형광판 영상과 CCD 카메라를 사용한 물팬텀으로, IMRT 치료계획에 대한 선량분포를 검증할 수 있는 가능성을 보였다.비의 회전에 의한 오차 보정, 필름의 광학적 밀도에 관한 보정 등 여러 가지 계통적 오차들에 대한 보정들이 선량분포 확인과정의 이해와 그 기준마련에 도움이 되겠지만 우리가 다룬 원점 불일치에 비해서 상대적으로 무시할 수 있었다. 마지막으로 선량분포 확인의 최종목표인 3 차원 선량분포 확인의 실제 적용을 위한 연구가 최적화 알고리듬을 이용하여 실험 중에 있다.\times$5cm, 10$\times$10cm, 15$\times$l5cm, 20$\times$20cm인 경우, 측정하여 얻은 PSF가 0.8%, 0.2%, 0.4%, 0.2%로 약간 높지만, 두 값은 매우 유사한 것으로 나타났다. 그리고, 기존의 BSF를 이용해 구한 TAR과 BJR 25에서 권고하는 PSF를 이용해 구한 TAR을 비교한 결과 field size 에 따라 약 1%-1.5% 정도로 BSF를 이용하여 구한 TAR보다 PSF를 이용하여 구한 TAR이 1.3% 정도 높게 나타났지만, 이것은 두 값의 절대적인 차이일 뿐, 실제로는 PSF를 이용하여 구한 TAR이 측정해서 구한 TAR과는 매우 유사한 값을 보여주고 있다. 결론 : 기존의 BSF를 이용해 구한 TAR과 PSF를 이용해 구한 TAR을 비교하였을 때, 약 1.3% 정도 높게 내고 있지만, 기존의 TAR보다는 PSF를 이용해 구한 TAR이 BJR 25와 잘 일치하고 있으므로 Co-60 원격치료용 방사선 조사장치를 사용할 경우 BSF보다는 PSF를 사용하는 것이 타당한 것으로 사료된다.tokines의 변화는 비록 통계학적인 차이는 없지만 비타민 C를 사용한 환자의 cytokines이 모두 사용하지 않은 환자에 비해 감소하였음을 보였다. 비타민 C는 부작용이 거의 없는 안전한 약으로서 말기 암 환자에서 비타민 C사용은 임상 증상을 호전시키는 데 도움

  • PDF

Sub-brow Resection via Relocation of Retro-orbicularis Oculi Fat and Preseptal Fat Unit (눈둘레근뒤 지방과 앞사이막 지방 단위의 재배치술을 통한 눈썹하 절제술)

  • Cha, Jeong-Ho;Woo, Sang-Min;Kim, Jin-Woo;Jung, Jae-Hak;Kim, Young-Hwan;Sun, Hook
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.477-484
    • /
    • 2011
  • Purpose: Retro-orbicularis oculi fat (ROOF) and preseptal fat pad (PSF) are deep fat structures of frontal and supraorbital area, that encounter galeal fat pad (GFP). If galeal wall is weakened by aging process, GFP loses its anchoring structure, moved downward pushing ROOF and PSF. This especially occur in lateral brow area. As a result of drooping, eyebrow affects the eyelid covering PSF as a sac descended to a lateral hooding and ptotic eyelid simultaneously. Consequently, in the case of lateral hooding and brow ptosis, besides the skin, deep fat structures (ROOF and PSF) should be corrected as well. Methods: ROOF-PSF repositioning technique in subbrow resection were performed. 21 cases of patients from April, 2007 to January, 2008. Before surgery, all patients were examined carefully to evaluate the degrees of dermatochalasia, drooping of the eyebrow, marginal reflex distance 1 (MRD1), eyelid crease height. Surgery was performed under local anesthesia, then excised the drooped eyelid skin by lateral subbrow resection, removed proper amount of ROOF, repositioned ROOF-PSF at the supraorbital rim, and fix it on periosteum. During follow up periods, the patients were surveyed of the satisfaction of surgery, and postoperative MRD1 was evaluated. Results: One patient had a hematoma on left eyebrow, and another one patient had a numbness on left forehead for two months. Except for these two patients, all patients had good results without any significant complications. The mean follow up period was about 5 months, and the position of lateral eyebrow maintained above the supraorbital rim in all cases. Postoperatively, MRD1 increased by 0.8 mm in 5-months mean follow up period. Conclusion: In patient with lateral brow ptosis and lateral hooding, the ROOF-PSF repositioning technique in sub-brow resection could be a good operative option.

Aboveground biomass of tropical rain forests by forest type in Brunei Darussalam (브루나이 열대우림의 산림 유형별 지상부 바이오매스 추정)

  • Jang, Minju;Roh, Yujin;Kim, Hyung-sub;Lee, Jeongmin;Son, Yowhan
    • Korean Journal of Environmental Biology
    • /
    • v.39 no.3
    • /
    • pp.266-272
    • /
    • 2021
  • The aboveground biomass (AGB) was estimated in mixed dipterocarp forests (MDF), peat swamp forests (PSF), and heath forests (HF) in Brunei Darussalam. A total of 81 (20 m×20 m) plots were established for MDF, PSF, and HF in three regions. The diameter at breast height(DBH) of all live trees (DBH≥10 cm) was measured within the plots. The AGB was calculated using an allometric equation with the measured DBH. The AGB(Mg ha-1) for MDF, PSF, and HF was 603.3±159.9, 305.9±23.4, and 284.3±19.3, respectively, and was significantly different among the forest types (p<0.05). The greater AGB in MDF than those in PSF and HF was due to the presence of emergent trees in MDF. The results showed that the number of emergent trees varied by forest type. Consequently, the appearance of the emergent trees could be one of the main factors affecting AGB in Southeast Asia's tropical rain forests.

Estimation of Circularly Symmetric Point Spread Function for Digital Auto-Focusing (디지털 자동 초점을 위한 등방성 점확산함수 추정)

  • Kim, Dong-Gyun;Park, Young-Uk;Lee, Jin-Hee;Paik, Joon-Ki
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.1
    • /
    • pp.7-13
    • /
    • 2009
  • This paper presents a circularly symmetric point spread function (PSF) estimation technique for a fully digital auto-focusing system. The proposed algorithm provides realistic, unsupervised PSF estimation by establishing the relationship between one-dimensional ideal step response and two-dimensional circularly symmetric PSF.