• Title/Summary/Keyword: PS4

Search Result 1,260, Processing Time 0.029 seconds

Synthesis, Characterization and Haemocompatibility of Poly(styrene-b-isobutylene-b-styrene) Triblock Copolymers (폴리(스티렌-이소부틸렌-스티렌) 삼중블록 공중합체의 합성, 분석 및 혈액적합성)

  • Ren, Ping;Wu, Yi-Bo;Guo, Wen-Ii;Li, Shu-Xin;Mao, Jing;Xiao, Fei;Li, Kang
    • Polymer(Korea)
    • /
    • v.35 no.1
    • /
    • pp.40-46
    • /
    • 2011
  • The synthesis of well-defined poly(styrene-b-isobutylene-b-styrene) (SIBS) triblock copolymers was accomplished by cationic sequential block copolymerization of isobutylene (IB) with styrene (St) using 1,4-di(2-chloro-2-propyl) benzene (DCC) /$TiCl_4$/2,6-di-tert-butylpyridine(DtBP) as an initiating system in methyl chloride ($CH_3Cl$)/methylcyclohexane(MeChx) (50/50 v/v) solvent mixture at $-80^{\circ}C$. The triblock copolymers exhibited excellent thermoplastic and elastomeric characteristics. Tensile strengths and Shore hardness increased with increasing polystyrene (PS) content, while elongation at break decreased. The blood-compatibility of SIBS was assessed by SEM observation of the platelet adhesion, blood clotting time and haemolysis ratio. The haemolysis ratios were below 5% which met the medical materials standard. The platelet adhesion test further indicated that SIBS block copolymers had a good blood compatibility.

Effects of Micropores on the Freezing-Thawing Resistance of High Volume Slag Concrete (슬래그를 다량 치환한 콘크리트의 동결융해 저항성능에 미치는 미세공극의 영향)

  • Kim, Rae-Hwan;Kim, Gyu-Yong;Lee, Bo-Kyeong;Shin, Kyoung-Su;Song, Gwon-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.67-74
    • /
    • 2015
  • In this study, effects of micropores on the freezing-thawing resistance of high volume slag concrete are reviewed. Concrete was made with slag which contains the ground granulated blast furnace slag(GGBS) and the pig iron preliminary treatment slag(PS) by replacing 0, 40, 70 %, then compressive strength, freezing-thawing resistance, micropores were reviewed. Also, specified design strength, target air contents were set. Deterioration was induced by using 14-day-age specimen which has low compressive strength for evaluating deterioration by freeze-thawing action. As results of the experiment, despite of specified design strength which has been set similarly and ensured target air contents, the pore size distribution of the concrete showed different results. Micropores in GGBS70 specimen have small amount of water which is likely to freeze because there is small amount of pore volume of 10~100 nm size at 0 cycle which has not been influenced by freezing-thawing. For these reasons, it was confirmed that the freezing-thawing resistance performance of GGBS70 is significantly superior than other specimens because relatively small expansion pressure is generated compared to the other specimens.

A Pulser System with Parallel Spark Gaps at High Repetition Rate

  • Lee, Byung-Joon;Nam, Jong-Woo;Rahaman, Hasibur;Nam, Sang-Hoon;Ahn, Jae-Woon;Jo, Seung-Whan;Kwon, Hae-Ok
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.305-312
    • /
    • 2011
  • A primary interest of this work is to develop an efficient and powerful repetitive pulser system for the application of ultra wide band generation. The important component of the pulser system is a small-sized coaxial type spark gap with planar electrodes filled with SF6 gas. A repetitive switching action by the coaxial spark gap generates two consecutive pulses in less than a microsecond with rise times of a few hundred picoseconds (ps). A set of several parameters for the repetitive switching of the spark gap is required to be optimized in charging and discharging systems of the pulser. The parameters in the charging system include a circuit scheme, circuit elements, the applied voltage and current ratings from power supplies. The parameters in the discharging system include the spark gap geometry, electrode gap distance, gas type, gas pressure and the load. The characteristics of the spark gap discharge, such as breakdown voltage, output current pulse and recovery rate are too dynamic to control by switching continuously at a high pulse repetition rate (PRR). This leads to a low charging efficiency of the spark gap system. The breakthrough of the low charging efficiency is achieved by a parallel operation of two spark gaps system. The operational behavior of the two spark gaps system is presented in this paper. The work has focused on improvement of the charging efficiency by scaling the PRR of each spark gap in the two spark gaps system.

An Experimental Study on Energy Consumption of Air Washer Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 에어와셔 외기공조시스템의 에너지소비량에 관한 실험적 연구)

  • Kim, Ki-Cheol;Kim, Hyung-Tae;Song, Gen-Soo;Yoo, Kyung-Hoon;Son, Seung-Woo;Shin, Dae-Kun;Park, Dug-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.297-305
    • /
    • 2012
  • In recent large-scale semiconductor manufacturing clean rooms, the energy consumption of outdoor air conditioning systems to heat, humidify, cool and dehumidify incoming outdoor air represents about 45% of the total air conditioning load required to maintain a clean room environment. Therefore, the energy performance evaluation and analysis of outdoor air conditioning systems is useful for reducing the outdoor air conditioning load for a clean room. In the present study, an experiment was conducted to compare the energy consumption of outdoor air conditioning systems with a simple air washer, an exhaust air heat recovery type air washer and a DCC return water heat recovery type air washer. It was shown from the present lab-scale experiment with an outdoor air flow of 1,000 $m^3/h$ that the exhaust air heat recovery type and DCC return water heat recovery type air washer outdoor air conditioning systems were more energy-efficient for the summer and winter operations than the simple air washer outdoor air conditioning system and furthermore, the DCC return water heat recovery type one was the most energy-efficient in the winter operation.

Production and Characterization of Extracellular Phospholipase D from Streptomyces sp. YU100

  • Lim, Si-Kyu;Choi, Jae-Woong;Chung, Min-Ho;Lee, Eun-Tae;Khang, Yong-Ho;Kim, Sang-Dal;Nam, Doo-Hyun
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.2
    • /
    • pp.189-195
    • /
    • 2002
  • Using Streptomyces sp. YU100 isolated from Korean soil, the fermentative production of phospholipase D was attempted along with its purification and characterization studies. When different carbon and nitrogen sources were supplemented in the culture medium, glucose and yeast extract were found to be the best. By varying the concentration of nutrients and calcium carbonate, the optimal culture medium was determined as 2.0% glucose, 1.5% yeast extract, 0.5% tryptone 0.3% calcium carbonate. During cultivation, the strain secreted most of the phospholipase D in the early stage of growth within 24 h. The phospholipase D produced in the culture broth exhibited hydrolytic activity as well as transphosphatidylation activity on lecithin (phosphatidylcholine). In particular, the culture broth showed 8.7 units/ml of hydrolytic activity when cultivated at $28^{\circ}C$ for 1.5 days. The phospholipase D was purified using 80% ammonium sulfate precipitation and DEAE-Sepharose CL-6B column chromatography, which produced a major band of 57 kDa on a 10% SDS-polyacrylamide gel with purity higher than 80%. The enzyme showed an optimal pH of 7 in hydrolytic reaction, and at pH 4 in a transphosphatidylation reaction. The enzyme activity increased until the reaction temperature was elevated to $60^{\circ}C$. The enzyme was relatively stable at high temperatures and neutral pH, but significantly unstable in the alkaline range. Among the detergents tested as emulsifiers of phospholipids, the highest enzyme activity was observed when 1.5% Triton X-100 was employed. However, no inhibitory effect by metal ions was detected. Under optimized reaction conditions, the purified enzyme not only completely decomposed PC to phosphatidic acid within 1 h, but also exhibited higher than 80% conversion rate of PC to PS by transphosphatidylation within 4 h.

A Clinical Study of Patent Ductus Arteriosus (동맥관 개존증의 임상적 고찰)

  • Jo, Jung-Gu;Park, Geon-Ju;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.574-581
    • /
    • 1985
  • Surgical treatment for PDA has been pivotal in historical development of surgery for congenital heart disease. A clinical study on 36 cases of operated PDA were performed during period from Aug. 1981 to Jul. 1985 at the Department of Thoracic & Cardiovascular Surgery in Chonbuk University. The following results are obtained. 1. The 8 males and 28 females ranged in age from 2 yrs, to 24 yrs, [mean 11 yrs.] 2. Chief complaints of the patients were dyspnea on exertion in 61%, palpitation in 39%, frequent URI in 12%, and no subjective symptoms in 11%. 3. On auscultation, continuous machinery murmur heard in 94% and systolic in 14%. 4. Radiologic findings of chest P-A showed increased density of pulmonary vascularity in 94%, cardiomegaly in 69%, and within normal limits in 5% of the patients. 5. EKG findings of the patients revealed LVH in 69%, RVH in 6%, BVH in 6%, and within normal limits in 17%. 6. Of the 36 patients, cardiac catheterization was performed in 34 patients. The results showed mean Qp/Qs = 2.25, mean Pp/Ps=0.42, and mean systolic pulmonary arterial pressure=53mmHg. 7. Surgical methods were as followed: The 32 case of ductal ligation and one case of division & suture technique for PDA through the left posterolateral thoracotomy were done. And 2 cases of ductal ligation one suture closure through the pulmonary artery were performed under the cardiopulmonary bypass. 8. Intraoperative complication was ductal rupture with division 8< suture for PDA and transient hoarseness in 1, recanalization in 1, and urethral stricture in 1 case postoperatively. 9. One patient died due to ductal rupture intraoperatively and operative mortality was 2.8%.

  • PDF

Selection of Pear Trees Free from Pear Black Leaf Spot Disease and Resistant Test for Pear Tree Cultivars (배나무잎검은점병 무독수의 선발 및 품종 저항성)

  • Oh, Jung Hwan;Nam, Ki Woong;Mizutani, Fusao
    • Horticultural Science & Technology
    • /
    • v.19 no.1
    • /
    • pp.43-47
    • /
    • 2001
  • This study was conducted to investigate the integrated control strategy against pear black leaf spot disease. Using indicator plant PS-95 we selected six virus-free trees (cv. Niitaka) from commercial orchards in the major pear production area. Disease symptom by pear black leaf spot in the shoot of pear (Niitaka) has been successfully inhibited by heat treatments for 3 weeks at temperature of $40^{\circ}C$ (day) and $32^{\circ}C$ (night) or 4 weeks at $37^{\circ}C$ and $30^{\circ}C$, respectively. However, survival rate of the shoot tips on stocks was low. Seven cultivars Niitaka, Imamura- aki, Waseaka, Nijisseiki, Wasenijisseiki, Shinsetsu and Whangkeumbae produced visible symptoms in the first year after inoculation with the virus. Other 11 selections remained symptomless. Two resistant cultivars Suwhangbae and Gamcheonbae were selected, which showed high fruit quality. It is recommended that these cultivars could be top-grafted onto the infected Niitaka trees to overcome the damage caused by the disease in the orchard.

  • PDF

Overview and Recent Development of Recycling Waste Refrigerators (폐(廢) 냉장고(冷藏庫) 재활용(再活用) 현황(現況)과 기술(技術) 전망(展望))

  • Yang, Hyunseok;Kim, Geon-Hong;Kong, Man-Sik;Park, Kiejin;Lee, Gwang Weon;Kim, Bo Saeng
    • Resources Recycling
    • /
    • v.22 no.4
    • /
    • pp.70-80
    • /
    • 2013
  • Waste refrigerator is the most large amount of item being recycled and the recycling process is the most complicated in WEEE (Waste Electrical and Electronic Equipment) because refrigerator is biggest product and consists of various parts and materials such as ferrous, non-ferrous, and plastics. Recently, recycling process of waste refrigerator has been being more complex since large capacity 2 door refrigerators and standing Kimchi refrigerators with various material are distributed on custom market. In addition, recycling of valuable resource from waste refrigerator is mandatory by WEEEs recycling legislation; therefore, high efficiency recycling enough for economic and environment-friendly recovery of valuable resource through present technical situation analysis and comparison of recycling technologies of waste refrigerator with advanced country.

Effects of Myofascial Release and Posture Correction Exercise on the Neck Movement and the Quality of Sleep in Patients with Chronic Tension-Type Headaches

  • Cho, Sunghak
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.4
    • /
    • pp.1897-1902
    • /
    • 2019
  • Background: Tension-type headaches, which make up the highest proportion of headaches, are prone to develop into chronic tension-type headaches (CTTH). The characteristic of CTTH in patients is that the active myofascial trigger point (ATrP) which causes pain in the muscles of the back of the head is increased, compared to the normal headache and moves the head position forward. Objective: The aim of this study was to investigate the effects of myofascial release (MFR) and posture correction in effectively improving neck function and sleep quality in the symptoms of CTTH patients. Design: Observer-blind study Methods: To reduce ATrP, MFR was applied and exercise was also applied to correct posture. The subjects of this study were 48 individuals randomly divided into three groups; The MFR group using the MFR technique; The MFR with exercise group subject to both the MFR technique and forward head position correction exercises (MFREx), and the control group. MFR and MFREx groups were given the relevant interventions twice a week for four consecutive weeks, and went through the number ATrPs, range of motion (ROM) of neck, Neck Disability Index (NDI) and the Pittsburgh Sleep Quality Index (PSQI) before and after the intervention. A physical therapist, who was fully familiar with the measuring methods of the equipment, was the measurer and not aware of the target's condition was blinded to take measurements only before and after intervention. Results: There was a significant improvement in the ATrP, Neck ROM, NDI and PSQI in the group of patients to whom the MFR technique and MFREx were applied. MFREx was more effective in increasing neck mobility. Conclusions: According to this study, the application of MFR is effective in improving neck movement and sleep quality in chronic tension headache patients.

Detection of Land Subsidence and its Relationship with Land Cover Types using ESA Sentinel Satellites data: A case study of Quetta valley, Pakistan

  • Ahmad, Waqas;Kim, Dongkyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.148-148
    • /
    • 2018
  • Land subsidence caused by excessive groundwater pumping is a serious hydro-geological hazard. The spatial variability in land use, unbalanced groundwater extraction and aquifer characteristics are the key factors which make the problem more difficult to monitor using conventional methods. This study uses the European Space Agency (ESA) Sentinel satellites to investigate and monitor land subsidence varying with different land covers and groundwater use in the arid Quetta valley, Pakistan. The Persistent Scattering Differential Interferometry of Synthetic Aperture Radar (PS-DInSAR) method was used to develop 28 subsidence interferograms of the study area for the period between 16 Oct 2014 and 06 Oct 2016 using ESA's Sentinel-1 SAR data. The uncertainty of DInSAR result is first minimized by removing the dynamic effect caused by atmospheric factors and then filtered using the radar Amplitude Dispersion Index (ADI) to select only the stable pixels. Finally the subsidence maps were generated by spatially interpolating the land subsidence at the stable pixels, the comparison of DInSAR subsidence with GPS readings showed an R 2 of 0.94 and mean absolute error of $5.7{\pm}4.1mm$. The subsidence maps were also analysed for the effect of aquifer type and 4 land covers which were derived from Sentienl-2 multispectral images. The analysis show that during the two year period, the study area experienced highly non-linear land subsidence ranging from 10 to 280 mm. The subsidence at different land covers was significantly different from each other except between the urban and barren land. The barren land and seasonally cultivated area show minor to moderate subsidence while the orchard and urban area with high groundwater extraction rate showed excessive amount of land subsidence. Moreover, the land subsidence and groundwater drawdown was found to be linearly proportional to each other.

  • PDF