A study of the communication transfer mode of physical signal (EKG, PPG) (생체신호(EKG, PPG)의 통신전송 모드에 대한 연구)

  • Kim, Jeong-Lae;Kim, Gwan-Seok;Kim, Jae-Yoon;Kim, Han-Na;Jang, Eun-Yiu
    • The Journal of the Convergence on Culture Technology
    • /
    • v.3 no.2
    • /
    • pp.55-59
    • /
    • 2017
  • We are confirmed to the transfer degree of physical signal with the communication code on the wireless communication system. The physical transfer system was consisted of such as ECG, PPG and Bluetooth part that received signal. Communication method was take the international standard level of IEEE802.15.1 forms, the frequency transition was needed the bandwidth of communication for transfer signal with the band-communication method. The program was expressed to receive with wireless communication condition that was consisted of such as the serial chart, processing and app inventor. Their signal was identified to transfer certainly the corrected signal. Therefore, signal processing for coding by the real-time graphing and using processing by a standard capacity of serial-chart graphing that will be possible to progress the improvement effectiveness of wireless communication system.

Design of Filter to Reject Motion Artifacts of PPG Signal by Using Two Photosensors

  • Lee, Ju-Won;Nam, Jae-Hyun
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.1
    • /
    • pp.91-95
    • /
    • 2012
  • The photoplethysmography (PPG) signal measured from a mobile healthcare device contains various motion artifacts occurring from a patient’s movements. Recently, to reject the motion artifacts, the method of using an acceleration sensor was suggested, but such sensors are very expensive. Therefore, this study deals with a novel sensor device to replace the acceleration sensor, and evaluated the performance of the proposed sensor experimentally. In the results of the experiments, it is shown that the proposed sensor device can reconstruct the PPG signal despite the occurrence of motion artifacts, and also that the variation rate in heart rate analysis was 1.22%. According to the experimental results, the proposed method can be applied to design a low-cost device.

A study on the development and performance evaluation of reflective type Heart rate measurement system for PAPS (PAPS를 위한 반사형 맥파 측정 장치의 개발 및 성능 평가)

  • Kim, Sheen-Ja;Lee, Young-Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.1
    • /
    • pp.160-166
    • /
    • 2012
  • We performed the development and performance evaluation of reflective type heart rate measurement system for PAPS. We used chip LED and chip photo TR. for low power driving. The measured PPG signal is preprocessed using high pass filter and low pass filter, and the preprocessed signal is displayed by LabVIEW. Also LabVIEW include the algorithm that extract effective signal and calculate the heart rate. We made sure that it will be able to apply to measurement equipment with high accuracy and repetition from exercising subject using this system and algorithm.

Feedback control for stable PPG measurement (안정된 광전용적맥파(PPG) 측정을 위한 피드백 제어 연구)

  • Lee, Hyun-Ki;Jho, Jung-Hyun;Sin, Woo-Sik;Yoo, Gil-Won
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.891-892
    • /
    • 2006
  • Photoplethsymogram (PPG) drifts due to the changes in respiration and blood perfusion as well as external light. This hinders a proper PPG measurement. We controlled DC drifts by controlling the signal ground of PPG signals. A microprocessor-based system successfully controlled DC drifts of PPG signals.

  • PDF

Development of Blood Pressure Estimation Methods Using The PPG and ECG Sensors (PPG 및 ECG 센서를 이용한 혈압추정 기법 개발)

  • Park, Hyun-Moon;Lee, Jung-Chul;Hwang, Tae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1257-1264
    • /
    • 2019
  • The traditional cuff-based method for BP(Blood Pressure) measurement is not suitable for continuous real-time BP measurement techniques. For this reason, the previous studies estimated various blood pressures by fusion with the electrocardiography (ECG) and photoplethysmogram (PPG) sensor signals. However, conventional techniques based on PPG bio-sensing measurement face many challenging issues such as noisy supply fluctuation, small pulsation, and drifting non-pulsatile. This paper proposed a novel BP estimation methods using PPG and ECG sensors, which can be derived from the relationship between PPG and ECG using PTT(Pulse Transit Time) and PWV(Pulse Wave Velocity). Unlike conventional height ratio features, which are extracted on the basis of the peaks in the PPG and ECG waveform. The proposed method can be reliably obtained even if there are missing peaks among the sensed PPG signal. The increased reliability comes from periodical estimation of the peak-to-peak interval time using ECG and PPG. After 250,000 times trials of the blood pressure measurement, the proposed estimation technique was verified with the accuracy of ±28.5% error, compared to a commercialized BP device.

A Study on the Temperature Dependence of PPG Measurement Devices (PPG 측정 장치에서의 온도 영향에 대한 연구)

  • Kim, Namsub
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.3
    • /
    • pp.306-311
    • /
    • 2019
  • This paper presents the temperature dependence of transmission-type and reflection-type PPG measurement devices that have been developed in the previous research. PPG signal can be distorted by external temperature such as skin temperature so that many of research was focused on the skin temperature effect. However, this paper focuses on the temperature of the device itself and we studied on the effect of device internal temperature. Experimental results showed that the temperature was increased like an irrational function graph and the transmission-type was not affected by the internal temperature but the reflection-type was affected by the internal temperature.

A Study on the Quantitative Pulse Type Classification of the Photoplethysmography (광용적맥파의 정량적 맥파형 분류에 관한 연구)

  • Jang, Dae-Jeun;Farooq, Umar;Park, Seung-Hun;Hahn, Min-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.328-334
    • /
    • 2010
  • Over the past few years, a considerable number of methods have been proposed and applied for the classification of photoplethysmography (PPG). Most of the previous studies, however, focused on the qualitative description of the pulse type according to specific disease and thus provided ambiguous criteria to interpreters. In order to screen out this problem, we present a quantitative method for the pulse type classification including the second derivative of photoplethysmography (SDPTG). In the PPG signal, we have classified the signal as 4 types using the position and the presence of the dicrotic wave. In addition, we have categorized the SDPTG signal as 7 types using the position and the presence of "c" and "d" wave and the sign of "c" wave. In order to check the efficacy of the proposed pulse type classification rule, we collected pulse signals from 155 subjects with different ages and sex. From the correlation analysis, Class 1(p<0.01) and Class 2(p<0.01) in the PPG signal are significantly correlated with ages. In a similar manner Class A(p<0.01), Class C(p<0.05), Class D(p<0.01), and Class F(p<0.01) in the SDPTG signal are considerably correlated with the ages. From these observations, and some earlier ones [4], [5], we can conclude that since the newly proposed method has objectivity and clarity in pulse type classification, this method can be used as an alternative of previous classification rules including similar age-related characteristics.

A Study on the Implementation of Transmission type PPG Measurement Device in a Wrist Watch (손목시계 형태의 투과형 PPG 측정 장치의 구현에 관한 연구)

  • Kim, Namsub
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.2
    • /
    • pp.161-167
    • /
    • 2017
  • This paper presents an effective PPG measurement device in a wrist watch for smart healthcare. PPG can be acquired by measuring absorption of light and PPG measurement device is classified as transmission and reflection type. Reflection type is easy to implement but vulnerable to motion artifact. Moreover, reflection type must use 2 hands at once if the device is implemeted in a wrist watch. This paper describes the implementation of robust transmission type PPG measurement device by using previous developed reflection type device. PPG sensor is clip type and can be separated from the device so that the influence of motion artifact can be reduced. The proposed device can transmit the measured signal in real-time and is useful for smart healthcare. For evaluation of the proposed device, PPG signals are compared with reflection type in the same condition. The results show that the proposed device has 20% improvement in performance.

Threat Detection Algorithm for Wearable Device User based on PPG Signal Processing (웨어러블 디바이스 착용자의 신변 보호를 위한 PPG 신호 처리 및 위협 감지 알고리즘 개발)

  • Sohee Yoo;Gyuwon Hwang;Jaehyun Yoo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2024.05a
    • /
    • pp.648-649
    • /
    • 2024
  • 웨어러블 디바이스 착용자의 PPG 신호 데이터로 위협 상황을 감지하는 알고리즘을 개발한다. 본 논문에서는 외부 환경에 예민한 PPG 센서에 최적화된 전처리 알고리즘을 제안하고 긍정 및 부정 영상 시청 실험을 통해 얻은 PPG 신호 데이터를 이용하여 위험 상황과 안전한 상황을 구분하는 정확도 96.87%의 1D-CNN 모델을 개발한다.

Comparison of vascular compliance between normal and replanted fingers using second derivative of photoplethysmogram (PPG 2차 미분을 이용한 정상과 재접합 손가락의 혈관 탄성도 비교)

  • Kim, Sung-Woo;Kim, Jin-Tae;Hong, Hyun-Ki;Kim, Soo-Chan;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.42-44
    • /
    • 2006
  • Up to the present, finger replantation patients have complained about various symptoms because of blood circulatory failure. Objective evaluation methods for the level of the blood circulatory failures in fingers were needed other than patient's subjective symptoms and complaints. Photoplethysmogram(PPG) measured from fingers is very useful for evaluation of vascular aging and sclerosis level since the PPG signal represents characteristics of peripheral vascular. Several researchers have reported that second derivative of the finger PPG waveform was useful to evaluate vascular compliance and developed various analysis methods for vascular compliance. However, vascular compliance study for finger replantation patient was never evaluated by using second derivative of PPG. Therefore, we aimed to objectively compare and to assess normal and replanted finger vascular compliance using the second derivative of PPG waveform in this study. The evaluated factors of second derivative of PPG are 'a', 'b', 'c', 'd', 'e' and b/a represents vascular compliance. Study found out that when vascular compliance is decreased, b/a is increased, the absolute value of b/a is decreased. For 43 finger replantation patients, the average vascular compliance of replanted finger is lower than the normal finger statistically(p=0.001). we suggested an objective evaluation of finger vascular compliance for finger replantation patients and effect of surgical operation.

  • PDF