• Title/Summary/Keyword: PPG 신호

Search Result 145, Processing Time 0.026 seconds

Real-time Intelligent Health and Attention Monitoring System for Car Driver (실시간 지능형 운전자 건강 및 주의 모니터링 시스템)

  • Shin, Heung-Sub;Jung, Sang-Joong;Seo, Yong-Su;Chung, Wan-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.5
    • /
    • pp.1303-1310
    • /
    • 2010
  • Recently, researches related with automative mechanism have been widely studied to increase the driver's safety by continuously monitoring the driver's health condition to prevent driver's drowsiness. This paper describes the design of wearable chest belt for ECG and reflectance pulse oximetry for SpO2 sensors based on wireless sensor network to monitor the driver's healthcare status. ECG, SpO2 and heart rate signals can be transmitted via wireless sensor node to base station connected to the server. Intelligent monitoring system is designed at the server to analyze the SpO2 and ECG signals. HRV (Heart Rate Variability) signals can be obtained by processing the ECG and PPG signals. HRV signals are further analyzed based on time and frequency domain to determine the driver's drowsiness status.

A Study on the Implementation of a Portable Healthcare System using Zigbee (Zigbee를 이용한 휴대형 헬스케어 시스템 구현에 관한 연구)

  • Kang, Sung-In;Kim, Gwan-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.9
    • /
    • pp.1793-1798
    • /
    • 2007
  • Recently there are some trends to construct smart home system infrastructure depending upon the development of Information and Communication Technology. Also requirements of the Ubiquitous Healthcare Systems at home which can monitor the status of health continuously are increased rapidly comparing with hospitals. Healthcare service can be divided into two categories. The first one is Alarm Service that can be used for the emergency status and the other one is Remote Support Service which can monitor the patient including home environments and give those diagnosis information to medical office or to his family. Generally wired networks and fixed healthcare measuring system have some limits to transmit reliable realtime based information for both categories described above comparing with portable monitoring system. Getting over the inefficiency we will design and implement portable healthcare system under the wireless Zigbee network environments.

Chronic Disease Management using Smart Mobile Device (스마트 모바일 기기를 이용한 만성질환 관리)

  • Kim, Gui-Jung;Han, Jung-Soo
    • Journal of Digital Convergence
    • /
    • v.12 no.4
    • /
    • pp.335-342
    • /
    • 2014
  • According to the recent trends in the growing elderly population, the chronically ill have increased. Thus the importance of the health care issues for them has emerged. In this paper, we want to implement a chronic disease management system using smart mobile devices. Proposed chronic disease management system is consisted of the biometric sensor, smart mobile devices, the patient management server, patient management DB, and patient symptoms analysis agent. The biometric sensor detects a biological information. Smart mobile devices receive the patient information from the sensor and transmit the information to the patient management server. The patient management server, patient management DB, and patient symptoms agent analysis agent analyze to process data delivered through a wireless communication network. Bio-signals includes modules of ECG, blood pressure, blood sugar and PPG. We are able to determine the current health status by monitoring measured biometric data through chronically ill health management system. We will focus on the individual service to be appropriate for a patient group in a mobile environment.

Estimation of Respiration Using Photoplethysmograph During Sleep (광용적맥파 신호를 이용한 수면 중 호흡 추정)

  • Park, Jong-Uk;Lee, Jeon;Lee, Hyo-Ki;Kim, Hojoong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.105-110
    • /
    • 2013
  • Respiratory signal is one of the important physiological information indicating the status and function of the body. Recent studies have provided the possibility of being able to estimate the respiratory signal by using a change of PWV(pulse width variability), PRV(pulse rate variability) and PAV(pulse amplitude variability) in the PPG (photoplethysmography) signal during daily life. But, it is not clear whether the respiratory monitoring is possible even during sleep. Therefore, in this paper, we estimated the respiration from PWV, PRV and PAV of PPG signals during sleep. In addition, respiration rates of the estimated respiration signal were calculated through a time-frequency analysis, and errors between respiration rates calculated from each parameter and from reference signal were evaluated in terms of 1 sec, 10 sec and 1 min. As a result, it showed the errors in PWV(1s: $36.38{\pm}37.69$ mHz, 10s: $36.53{\pm}38.16$ mHz, 60s: $30.35{\pm}38.72$ mHz), in PRV(1s: $1.45{\pm}1.38$ mHz, 10s: $1.44{\pm}1.37$ mHz, 60s: $0.45{\pm}0.56$ mHz), and in PAV(1s: $1.05{\pm}0.81$ mHz, 10s: $1.05{\pm}0.79$ mHz, 60s: $0.56{\pm}0.93$ mHz). The errors in PRV and PAV are lower than that of PWV. Finally, we concluded that PRV and PAV are more effective than PWV in monitoring the respiration in daily life as well as during sleep.

Development of Oriental-Western Fusion Patient Monitor by Using the Clip-type Pulsimeter Equipped with a Hall Sensor, the Electrocardiograph, and the Photoplethysmograph (홀센서 집게형 맥진기와 심전도-용적맥파계를 이용한 한양방 융합용 환자감시장치 개발연구)

  • Lee, Dae-Hui;Hong, Yu-Sik;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.4
    • /
    • pp.135-143
    • /
    • 2013
  • The clip-type pulsimeter equipped with a Hall sensor has a permanent magnet attached in the "Chwan" position to the center of a radial artery. The clip-type pulsimeter is composed of a hardware system measuring voltage signals. These electrical bio-signals display pulse rate, non-invasive blood pressure, respiratory rate, pulse wave velocity (PWV), and spatial pulse wave velocity (SPWV) simultaneously measured by using the radial artery pulsimeter, the electrocardiograph (ECG), and the photoplethysmograph (PPG). The findings of this research may be useful for developing a oriental-western biomedical signal storage device, that is, the new and fusion patient monitor, for a U-health-care system.

The process of estimating user response to training stimuli of joint attention using a robot (로봇활용 공동 주의 훈련자극에 대한 사용자 반응상태를 추정하는 프로세스)

  • Kim, Da-Young;Yun, Sang-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.10
    • /
    • pp.1427-1434
    • /
    • 2021
  • In this paper, we propose a psychological state estimation process that computes children's attention and tension in response to training stimuli. Joint attention was adopted as the training stimulus required for behavioral intervention, and the Discrete trial training (DTT) technique was applied as the training protocol. Three types of training stimulation contents are composed to check the user's attention and tension level and provided mounted on a character-shaped tabletop robot. Then, the gaze response to the user's training stimulus is estimated with the vision-based head pose recognition and geometrical calculation model, and the nervous system response is analyzed using the PPG and GSR bio-signals using heart rate variability(HRV) and histogram techniques. Through experiments using robots, it was confirmed that the psychological response of users to training contents on joint attention could be quantified.

Development of 3 Channel Biomedical Signal Measurement System for Mac-yule (맥율용 3채널 생체신호 계측시스템 개발)

  • Byeon, M.K.;Kim, H.J.;Jang, J.K.;Han, S.W.;Huh, W.
    • Journal of IKEEE
    • /
    • v.11 no.1 s.20
    • /
    • pp.24-29
    • /
    • 2007
  • In this paper, we developed a Mac-Yule measurement system which consider psychological stable state of patience. The developed system consist with a hardware device that can derive a EEG, respiration and pulse wave, and a software which acquire a biological signal and signal processing The EEGs are derived with bipolar method from frontal head. The respiration signals obtain from nasal front with a transducer which consist with thermistor bridge. The pulse waves are detected from earlobe with photoplethysmograph method. A power spectrum of EEG are used as the decision parameters of psychological stable state of patience. The decision of Mac-Yule are defined as origin text method that of numbers of pulse to 1 respiration period. As the results of experiment with developed system, we could have a spectrum band discretion of EEG signal, stable respiration signal detection and automatic gain controlled pulse signal with realtime. And then, we could detect Mac-Yules from processed signals.

  • PDF

Affective interaction to emotion expressive VR agents (가상현실 에이전트와의 감성적 상호작용 기법)

  • Choi, Ahyoung
    • Journal of the Korea Computer Graphics Society
    • /
    • v.22 no.5
    • /
    • pp.37-47
    • /
    • 2016
  • This study evaluate user feedback such as physiological response and facial expression when subjects play a social decision making game with interactive virtual agent partners. In the social decision making game, subjects will invest some of money or credit in one of projects. Their partners (virtual agents) will also invest in one of the projects. They will interact with different kinds of virtual agents which behave reciprocated or unreciprocated behavior while expressing socially affective facial expression. The total money or credit which the subject earns is contingent on partner's choice. From this study, I observed that subject's appraisal of interaction with cooperative/uncooperative (or friendly/unfriendly) virtual agents in an investment game result in increased autonomic and somatic response, and that these responses were observed by physiological signal and facial expression in real time. For assessing user feedback, Photoplethysmography (PPG) sensor, Galvanic skin response (GSR) sensor while capturing front facial image of the subject from web camera were used. After all trials, subjects asked to answer to questions associated with evaluation how much these interaction with virtual agents affect to their appraisals.

PPG and MPG waveform difference research using Bloodflow simulator (혈류 시뮬레이터를 이용한 매질별 광용적맥파 및 자계용적맥파 파형 차이점 연구)

  • Kim, Kyeng-Nam;Lee, Kang-Hwi;Lee, Young-Jae;Kang, Seung-Jin;Lee, Jeong-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1399-1400
    • /
    • 2015
  • 광용적맥파는 인체 내에 흐르는 혈류의 움직임을 빛을 이용하여 관찰 및 측정하며, 자계용적맥파는 코일 주변에 발생하는 자기장을 이용하여 신호를 측정한다. 본 논문에서는 매질별 광용적맥파형과 자계용적맥파형을 혈류 시뮬레이터를 이용하여 비교하였다. 혈류 시뮬레이터의 출력파형은 동맥혈압파형으로 설정하여 실험을 진행하였다. 매질은 음용수와 식염수를 이용하였으며, 매질별 광용적맥파형의 변화는 거의 드러나지 않았으나 자계용적맥파의 파형은 변화가 있음을 확인하였다.

  • PDF

The positive effect of motion base in virtual navigation (가상주행에서 모션베이스의 긍정적인 효과)

  • 김영윤;김은남;고희동;김현택
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.11a
    • /
    • pp.103-109
    • /
    • 2002
  • 본 연구에서는 가상현실사용자들이 모션베이스를 사용함에 따라 가상현실에 대한 평가가 어떻게 달라지는지를 조사하였다. 33명의 피험자를 대상으로 모션베이스 평가설문과 자기보고를 통해 가상현실에서의 현실감, 재미, 멀미감을 조사하고 가상주행 전, 중, 후에 내장근전위, 피부전도도, 말초체온, 말초혈류량, 심박률, 눈 깜박임의 생리신호를 측정, 분석함으로써 모션베이스 유무에 따른 심리·생리적인 변수들에서의 차이를 알아보았다. 모든 피험자는 2주 간격으로 모션베이스 사용조건과 모션베이스를 사용하지 않는 조건에서 두 번 가상현실을 경험하였다. 가상현실에 대한 현실감, 재미항목에서 모두 모션베이스를 사용한 조건이 높은 점수를 나타냈다. 또한 모션베이스를 사용한 조건에서 멀미보고수가 감소하는 경향이 나타났다. Tachyarrythmia의 상대파워 변화량과 PPG 최대진폭의 평균변화량 비교는 모션베이스를 사용한 가상현실 조건이 생리적인 요동을 적게 일으키는 것으로 나타났다. 이러한 결과들은 시각제시기와 동기화된 모션베이스를 도입함으로써, 가상현실에 대한 현실감은 높이면서 멀미감은 줄일 수 있다는 가능성을 보여준다.

  • PDF