• Title/Summary/Keyword: PPG 신호

Search Result 143, Processing Time 0.023 seconds

Research on Classification of 2 dimension Emotion by Pattern analysis of Autonomic response (자율신경계 반응 패턴 분석을 통한 2차원 감성 분류에 대한 연구)

  • 황민철;임평규;김혜진;김세영
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.11a
    • /
    • pp.279-282
    • /
    • 2002
  • 자율신경계 반응은 인간의 각성을 측정하는 변수가 될 수 있다(황민철 외, 2001). 본 연구에서는 자율신경계 반응만으로 인간의 2차원 감성 분류를 할 수 있는지를 살펴보았다. 5명의 피험자에게 대중가요나 효과음 등과 같은 다양한 청각자극을 제시하여 감성을 유발한 후, 자율신경계의 반응을 3가지 생리신호(GSR, SKT, PPG)를 통해 측정하여 반응 패턴을 분석하였다. 결과적으로, 자율신경계 반응 패턴은 각성/이완뿐만 아니라 쾌/불쾌간 감성 구분의 가능성을 확인할 수 있었다.

  • PDF

Respiratory Effort Monitoring Using Pulse Transit Time in Human (인체에서 맥파전달시간을 이용한 호흡노력 모니터링)

  • 정동근
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.485-489
    • /
    • 2002
  • In this study. respiratory efforts were monitored by the change of pulse transit time (PTT) which is related with the arterial pressure PTT is the time interval between the peak of R wave in ECG and the maximal slope point of photoplethysmogram(PPG). Biosignals, ECG and finger photoplethysmogram(PPG), were converted to digital data, and PTT was evaluated in personal computer with every heart beat. Results were presented as a graph using spline interpolation. The software was implemented in C$\^$++/ as a window-based application program. PTT was periodically changed according to airflow in resting respiration. In the resting respiration, PTT was changed according to the respiratory cycle. The amplitude of PTT fluctuation was increased by deep respiration, and increased by partial airway obstruction. These results suggest that PTT is responsible to respiratory effort which could be evaluated by the pattern of PTT change. And it is expected that PTT could be applied in the monitoring of respiratory effort by noninvasive methods, and is very useful method for the evaluation of respiratory distress.

Measurement of a Blood Velocity by using Photoplethysmograph and Radial Artery Pulse Wave Equipped with Magnetic Hall Device (자성 홀소자 맥진기와 용적맥파계의 맥진파형을 이용한 혈류속도 측정 연구)

  • Jang, Deok-Hyeong;Kim, Dam-Bee;Choi, Suel-Gi;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.4
    • /
    • pp.130-135
    • /
    • 2012
  • One prototype product of clip-type pulsimeter equipped with magnetic field sensing semiconductor Hall device after one permanent magnet attached "Chwan" position in center of a radial artery was developed. The clip-pulsimeter was composed of the hard ware system measuring to voltage signals. To measure the blood velocity, the radial artery pulsimeter is simultaneously connected the PPG (photoplethysmograph). Analysis and comparison of two pulse waves data has done obtained from a clinical test of forty subjects of 20 ages. The value of a blood velocity simultaneously measured from a radial artery puls wave and PPG is an average value of 0.8m/s. The usage of this research results is possible to store the biomedical signals for health care.

Ring-type Heart Rate Sensor and Monitoring system for Sensor Network Application (센서 네트워크 응용을 위한 반지형 맥박센서와 모니터링 시스템)

  • Jang, In-Hun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.5
    • /
    • pp.619-625
    • /
    • 2007
  • As low power, low cost wireless communication technology like Bluetooth, Zigbee, RFID has been put to practical use together with the wellbeing trend, the concern about ubiquitous health care has been greatly increased and u-Health is becoming one of the most important application in the sensor network field. Especially, development of the medical services to be able to cope with a state of emergency for solitary senior citizens and the aged in silver town is very meaningful itself and their needs are also expected to continuously increase with a rapid increase in an aging population. In this paper we demonstrate the feasibility of extracting accurate heart rate variability (HRV) measurements from photoelectric plethysmography(PPG) signals gathered by a ring type pulse oximeter sensor attached to the finger. For this, we made 2 types of ring sensor, that is reflective and pervious type, and developed the remote monitoring system which is able to collect HR data from ring sensor, analyze and cope with a state of emergency.

Correlation between Stories and Emotional Responses for American Movies (영화 스토리와 관객 감성반응과의 상관성에 대한 연구)

  • Woo, Jeong-Gueon
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.7
    • /
    • pp.13-19
    • /
    • 2021
  • While watching the movie, the audience shows various emotional reactions. Emotional reactions such as sadness and anger, joy and anger appear depending on the storyline of the film. This aspect can be seen through the audience's brain wave response. This study is to examine the relationship between the movie story development and the movie story development through brain wave measurement of the emotional reaction of the audience in situations and events occurring in the movie development. Four American films, which represent each genre and are well known to many people, were selected for the study. These are of the adventure genre, of the animation genre, of the action genre, and of the drama genre. In order to measure the emotional response of these movies, four cases were set centered on the PPG of EEG and analyzed as a time series graph pattern. It can be seen that the emotional response on the graph has a certain relationship with the story development. It is expected that this study will help in selecting a genre when making a movie in the future, especially when deciding how to compose and develop a story, and it will help to induce the emotions of the audience.

Design of Tag to Measure Biomedical Signal for Interfacing with Smart phone (스마트 폰 연동형 생체신호 측정 태그 설계)

  • Kwon, Eon-hyeok;Lee, Dong-chang;Jo, Su-hyun;Lee, Ju-won;Nam, Jae-hyun;Park, Hee-jung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.819-821
    • /
    • 2014
  • This study is proposed the design method of tag to measure biomedical signal for interfacing with smart phone. The measurable physiological signals are ECG and PPG. On the smart phone by using the measured signals, we have designed the tag that can extract parameters such as heart rate, heart rate distribution, mean blood pressure, arterial stiffness, autonomic nervous balance. By using the estimated medical informations from this tag, One's health status will be able to manage one.

  • PDF

Application of Biosignal Data Compression for u-Health Sensor Network System (u-헬스 센서 네트워크 시스템의 생체신호 압축 처리)

  • Lee, Yong-Gyu;Park, Ji-Ho;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.352-358
    • /
    • 2012
  • A sensor network system can be an efficient tool for healthcare telemetry for multiple users due to its power efficiency. One drawback is its limited data size. This paper proposed a real-time application of data compression/decompression method in u-Health monitoring system in order to improve the network efficiency. Our high priority was given to maintain a high quality of signal reconstruction since it is important to receive undistorted waveform. Our method consisted of down sampling coding and differential Huffman coding. Down sampling was applied based on the Nyquist-Shannon sampling theorem and signal amplitude was taken into account to increase compression rate in the differential Huffman coding. Our method was successfully tested in a ZigBee and WLAN dual network. Electrocardiogram (ECG) had an average compression ratio of 3.99 : 1 with 0.24% percentage root mean square difference (PRD). Photoplethysmogram (PPG) showed an average CR of 37.99 : 1 with 0.16% PRD. Our method produced an outstanding PRD compared to other previous reports.

WSN platform for health and environmental monitoring system for workers (해상 근로자 건강 및 환경 모니터링을 위한 WSN 플랫폼)

  • Gu, Ye-Jin;Lyu, Changjin;Lee, Su-Bin;Chung, Wan-Young
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2018.10a
    • /
    • pp.928-931
    • /
    • 2018
  • 고립된 해상 작업 환경에서의 작업자의 건강상태 관리와 혹시 모를 추락탐지는 작업자의 안전을 위해 매우 중요하다. 본 논문에서는 이러한 고립공간 작업자의 안전을 모니터링하기 위한 헬멧에 부착할 수 있는 IoT 시스템을 위한 알고리즘을 제안한다. 이는 장치가 작업 중에 긴급 상황인지 신속하게 판단할 수 있다. 스마트폰은 누구나 들고 다니기 때문에 사용자 환경은 스마트폰을 이용하여 적용되었다. 작업자들이 착용할 용도이기 때문에 PPG 센서는 불편하지 않도록 귀에 부착한다. PPG 센서를 단독으로 사용하여 스트레스 정도를 파악한다. 3축 가속도 센서는 헬멧에 부착되고 추락을 감지하는데 사용된다. 우리는 여러 센서와 블루투스 통신을 이용하여 발전된 센서 시스템을 만든다. 또한, 우리는 3축 가속도 샘플을 분석하고 정규화하는 알고리즘을 JAVA에서 구현하였다. 스마트 폰을 사용하는 이점은 신호 처리를 위해 별도의 마이크로프로세서(mcu)가 필요하지 않으며 내부 통신 시스템을 통해 제어 센터에 정보를 전송할 수 있다는 것이다.

Peak Detection of Pulse Wave Based on Fuzzy Inference and Multi Sub-Band Filters for U-Healthcare (U-헬스케어를 위한 퍼지추론과 다중 하위대역 필터를 기반한 맥파 최대치 검출)

  • Lee, Ju-Won;Lee, Byeong-Ro
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.12
    • /
    • pp.2159-2164
    • /
    • 2008
  • Ubiquitous healthcare system is system that monitors and manages user's health information, and most important in the healthcare system is accuracy of the measured health data. But, the accuracy changes remarkably according to user's motion artifacts in real life. To elevate accuracy of health data, we proposed new algorithm to detect maximum point of pulse wave for heart rate extraction. and the proposed algorithm is to detect maximum points detect of pulse wave in photo-plethysmography signal included motion artifacts by fuzzy inference and multi sub-band filters. In results of experiment to evaluate the performance of the proposed algorithm, we could verify the proposed algorithm extracted maximum point of pulse wave in complex motion artifacts.

Color Therapy Lighting for Physical and Mental Relaxation based on Bio-signal (생체신호 기반의 심신 완화를 위한 컬러테라피 조명등)

  • Lee, Min-Hye;Kang, Sun-kyoung;Shin, Seong-yoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.660-662
    • /
    • 2022
  • Due to the prolonged aftermath of COVID-19, the number of modern people suffering from stress and mental illness is increasing. Recently, various methods of color therapy are being studied using LED lighting to improve concentration, relieve stress, manage skin, and improve sleep quality. In this paper, pulse waves are measured and heart rate variability is extracted using a PPG (Photoplethysmogram) sensor to analyze a person's mental and physical state. Using RGBLED and Arduino, we propose a mood lighting system that automatically changes colors according to changes in mental and physical conditions by producing color lighting of various wavelengths, which are mainly used to stabilize the mental state.

  • PDF