• 제목/요약/키워드: PP2A

Search Result 1,080, Processing Time 0.029 seconds

Hydrophilic Modification of Polypropylene Microfiltration Membrane by Radiation-Induced Graft Polymerization and Water Permeability (방사선 조사 그라프트중합에 의한 폴리프로필렌 정밀여과막의 친수화 및 물 투과특성)

  • Park, Jae-Hyung;Lee, Kune-Woo;Hwang, Taek-Sung;Lee, Jae-Won;Oh, Won-Jin
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.954-959
    • /
    • 1999
  • Radiation-induced grafting of 2-hydroxyethyl methacrylate(HEMA), acrylic acid(AAc) and methacrylic acid(MAAc) onto polypropylene microfiltration membrane has been studied. The effect of grafting conditions such as solvent composition(MeOH and $H_2O$) and monomer concentration on the grafting yield in investigated. The highest degree of grafting is obtained at a solvent composition of 25% $H_2O$:75% MeOH for HEMA, pure water for AAc and 50% $H_2O$:50% MeOH for MAAc. Modification of the PP membranes with hydrophilic monomers is shown to cause an increase in the water permeation flux of the membranes. It is found that HEMA is the best monomer to increase the water permeation flux and the highest water permeation flux is obtained at 99% degree of grafting. The water permeation flux of AAc-grafted PP membrane and MAAc-grafted PP membrane is very sensitive to environmental pH and $Cu^{2+}$ ion, but the water permeation flux of HEMA-grafted PP membrane scarcely depends on pH and $Cu^{2+}$ ion.

  • PDF

Effect of Temperature on Tensile Fracture Behavior of Glass Fiber Polypropylene Composites (온도변화에 따른 GF/PP복합재료의 인장파괴거동)

  • 고성위;엄윤성;허경환;김엄기;김형진
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.240-245
    • /
    • 2001
  • The tensile strength and failure mechanisms of glass fiber polypropylene (GF/PP) composites are investigated in the temperature range from ambient to 8$0^{\circ}C$. The tensile strength increases as fiber volume fraction ratio increase. The tensile strength shows a maximum at ambient temperature, and it tens to decrease as temperature goes up. Major failure mechanisms of GF/PP composites can be classified as fiber matrix debonding, fiber pull-out, delamination and matrix deformation.

  • PDF

Spalling Properties of 80MPa High Strength Concrete with Fiber (복합섬유(PP,NY)를 혼입한 설계강도 80MPa 3성분계 고강도콘크리트의 폭렬특성)

  • Kim, Seong-Deok;Lee, Bum-Sik;Bae, kee-Sun;Kim, Sang-yun;Park, Su-Hee
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.51-54
    • /
    • 2009
  • In this study, the fire resistance test was carried out with a parameter such as fiber(PP+NY) mixed ratio on high strength concrete with 80MPa, and the spalling resistance property was evaluated. Concrete material test was carried out with a parameter such as fiber(PP+NY) mixed ratio(0%, 0.05%, 0.1%, 0.2%) of high strength concrete with 80MPa. Although the flowability and the strength capacity were delicately decreased with a increase of fiber mixed ratio, they satisfied the target limits. As the spalling resistance property after the fire resistance test of 3 hours, the spalling was partly shown on the high strength concrete with fiber(PP+NY) mixed ratio of 0% but, wasn't shown on the high strength concrete with fiber(PP+NY) mixed ratio of 0.05% ~ 0.2%.

  • PDF

Shape-Stabilized Phase Change Materals : Frozen Gel from Polypropylene and n-Octadecane For Latent Heat Storage

  • Son, Tae-Won;Kim, Tae-Hun;Kim, Bong-Shik;Kim, Byung-Giu
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.375-375
    • /
    • 2006
  • The preparation methods are to be used as "melting method" and "absorption method", respectively. The reaction mixture in the reaction container was heating up the reaction mixture to $200^{\circ}C$ for 2 hour. The mixing time of lab scale preparation should be provided quit long, instead of the short working time in a compounder vessel. And The PP-PCM mixture in the reaction container was heating up the mixture around $60-80^{\circ}C$ for 2 hour. A melting method of frozen gel with 50/50 weight ratio of polypropylene-normal octadecane was prepared by adding PP chip and normal octadecane. An absorption method of frozen gel with 70/30 weight ratio of PP 4.8-normal n-octadecane was prepared by adding PP powder and normal octadecnae.

  • PDF

A PROOF OF STIRLING'S FORMULA

  • Park, June-Sang
    • Communications of the Korean Mathematical Society
    • /
    • v.9 no.4
    • /
    • pp.853-855
    • /
    • 1994
  • The object of present note is to give a very short proof of Stirling's formula which uses only a formula for the generalized zeta function. There are several proofs for this formula. For example, Dr. E. J. Routh gave an elementary proof using Wallis' theorem in lectures at Cambridge ([5, pp.66-68]). We can find another proof which used the Maclaurin summation formula ([5, pp.116-120]). In [1], they used the Central Limit Theorem or the inversion theorem for characteristic functions. In [2], pp. Diaconis and D. Freeman provided another proof similarly as in [1]. J. M. Patin [7] used the Lebesgue dominated convergence theorem.

  • PDF

Mospholops Mosphogicel Chauge on the Derelopmest of Duitus Oeferers of Meat Trppe Cockerds (육닭 정관의 발육에 따른 형태학적 변화)

  • 한방근;김우권;이재홍
    • Korean Journal of Animal Reproduction
    • /
    • v.8 no.1
    • /
    • pp.46-55
    • /
    • 1984
  • The purpose of the experiment was to clarify morphologically normal growth pattern of the ductus deference in accordance with the sex maturity of meat-type cockerels. 1. Diameter of lumens in u, pp.r, mid and lower parts of ductus deferens, the most conspicuous enlargement of lumen was observed in the lower part. Heights of epithelial layers of ductus deferens showed abrupt growth at 12 weeks of age with subsequent gradual growth in all the part of u, pp.r, mid and lower, and heights of those at 30 weeks were a, pp.oximately 4 times as large in the u, pp.r and mid parts and 5 times as large in the lower part in contrast to those at 4 weeks of age. Thickness of muscular layer of ductus showed gradual growth in contrast with the diameter of lumen and height of epithelial layer, showing 1.3 times as large in the u, pp.r part, 1.6 times in the mid part and 1.9 times in the lower part at 30 weeks of age in contrast to the thickness at 4 weeks of age. 2. Within 10 weeks after hatching, lining cells of ductus deferens were mainly composed of round cells and columnar cells in simple columnar epithelium. During 10th to 20th week, the lining cells were mainly composed of high columnar cells and round cells in pseudostratified epithelium. From 22nd week, the lining cells were composed of pseudostratified columnar cells. Whereas round cells disa, pp.ared gradually. Enlargement of lumen and pooling of sperms in ductus deferens coincided with the maturation of seminiferous tubules. 3. In simple correlation between the values of testis weight and the values from various measurements in the ductus deferens, there was significant correlation coefficient with each other. 4. In the India ink absorption test, India ink granules were not absorbed on the epithelium of the ductus deferens, but the granules reactive to acid phosphatase a, pp.ared in a line on the free border of each parts of the ductus deferens. The granules reactive to alkaline phosphatase were noted on the luminal border of ductus deferens mainly, but weak reaction showed than acid phophatase were a, pp.ared. The granules reactive to PAS were a, pp.ared mostly near on the free border of hte epithelial cells of ductus deferens. 5. Number of sperm, Indes of sperm vitality and MRT in the different parts of ductus deferens were tended to be somewhat dominant in the mid and lower parts than in u, pp.r part, even though not significant in the statistical analysis. Ratio of sperm abnormality was tended to be relatively high in the u, pp.r part too, and in the sperm of abnormality blunted head was less in number significantly in the mid and lower part than in the u, pp.r part.

  • PDF

Strength Properties of RC Slabs under Elevated Temperatures from Fire (화재시 온도증가로 인한 RC 슬래브의 강도 특성)

  • Im, Cho-Rong;Chung, Chul-Hun;Kim, Yu-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.4
    • /
    • pp.48-60
    • /
    • 2010
  • The fire resistance performance of 2 RC slabs after exposure to the ISO-834 fire standard without loading has been experimentally investigated. A Comparison is made of the fire resistance performance between RC slabs without PP(polypropylene) fibers and RC slabs with PP fibers. From the fire test results, the presence of PP fibers in RC slabs can reduce spalling and enhance their fire resistance. Until now, the determination of fire resistance of reinforced concrete(RC) slabs has essentially been based on tabulated data. According to ACI 216 code and EUROCODE 2, the design of concrete structures is essentially based on tabulated data for appropriate concrete cover and various fire durations. From the comparison between fire test results and codes, current fire design provisions of codes such as the ACI 216 and the EUROCODE 2 are unconservative for estimating mechanical properties of RC slabs at elevated temperatures.

An Energy Efficient $V_{pp}$ Generator using a Variable Pumping Clock Frequency for Mobile DRAM (가변 펌핑 클록 주파수를 이용한 모바일 D램용 고효율 승압 전압 발생기)

  • Kim, Kyu-Young;Lee, Doo-Chan;Park, Jong-Sun;Kim, Soo-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.6
    • /
    • pp.13-21
    • /
    • 2010
  • A energy efficient $V_{pp}$ generator using a variable pumping frequency for mobile DRAM is presented in this paper. The proposed $V_{pp}$ generator exploits 3 stages of a cross-coupled charge pump for energy efficiency. Instead of using a fixed pumping frequency in the conventional $V_{pp}$ generator, our proposed $V_{pp}$ generator adopts a voltage-controlled oscillator and uses variable frequencies to reduce the ramp-up time. As a result, our $V_{pp}$ generator generates 3.0 V output voltage with 24.0-${\mu}s$ ramp-up time at 2 mA current load and 1 nF capacitor load with 1.2 V supply voltage. Experimental results show that the proposed $V_{pp}$ generator consumes around 26% less energy (1573 nJ $\rightarrow$ 1162 nJ) and reduces 29% less ramp-up time (33.7-${\mu}s$ $\rightarrow$ 24.0-${\mu}s$) compared to the conventional approach.

Spalling Reduction Effect of PP Fibers and Silica Fume on High Strength Reinforced Concrete Columns (PP섬유 및 실리카흄이 고강도 철근콘크리트 기둥의 폭열 저감에 미치는 영향)

  • Yoo, Suk-Hyeong
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.1-6
    • /
    • 2009
  • High Strength Concrete has a disadvantage of the brittle failure under fire due to the spalling. It is reported that spalling is caused by the vapor pressure under fire and polypropylene (PP) fiber has an important role in protecting from spalling. The silica fume which is essentially mixed in high strength concrete decrease the permeability of concrete, and this will increase the degree of spalling. The fire resistance characteristics of high-strength reinforced concrete columns with various contents of PP fiber and silica fume were investigated in this study. In results, the ratio of unstressed residual strength of columns increases as the content of PP fiber increases from 0% to 0.2% and the ratio decreases as the content of silica fume increases from 7% to 21%.