• 제목/요약/키워드: POM-01

검색결과 3건 처리시간 0.017초

스카이라디오미터 모델에 따른 에어러솔의 광학적 특성 비교 (Comparison of Aerosol Optical Properties from Different Models of Skyradiometer)

  • 최용주;김영성;손병주
    • 대기
    • /
    • 제21권3호
    • /
    • pp.311-317
    • /
    • 2011
  • Aerosol optical properties from the radiation measurements by SKYNET PREDE skyradiometers, POM-01 and POM-02 were compared during the inter-calibration campaign at Seoul in February 2009. The monochromatic solar flux at the top of the atmosphere ($F_0$) gave a relative standard deviation (RSD) of 9-10% for both instruments. This comparatively high value of RSD was probably because $F_0$ was determined at short time intervals, in the morning and afternoon, using the measurements made in the polluted environment of Seoul. Although POM-02 was more effective in tracking the solar radiation, aerosol optical depths (AODs) from the two instruments were very similar after the cloud screening procedure. The squared correlation coefficients ($R^2$) of single scattering albedo (SSA) and real and imaginary refractive indices between the two instruments was around 0.5 but increased to 0.7-0.8 when only using AOD greater than 0.4. Nevertheless, mean values of the Angstrom exponent, SSA, and the imaginary refractive index of POM-02 were higher than those of POM-01.

Development of a device to improve the precision of water surface identification for MeV electron beam dosimetry

  • F. Okky Agassy;Jong In Park;In Jung Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1431-1440
    • /
    • 2024
  • The study aimed to develop a laser-based distance meter (LDM) to improve water surface identification for clinical MeV electron beam dosimetry, as inaccurate water surface determination can lead to imprecise positioning of ionization chambers (ICs). The LDM consisted of a laser ranging sensor, a signal processing microcontroller, and a tablet PC for data acquisition. I50 (the water depth at which ionization current drops to 50 % of its maximum) measurements of electron beams were performed using six different types of ICs and compared to other water surface identification methods. The LDM demonstrated reproducible I50 measurements with a level of 0.01 cm for all six ICs. The uncertainty of water depth was evaluated at 0.008 cm with the LDM. The LDM also exposed discrepancies between I50 measurements using different ICs, which was partially reduced by applying an optimum shift of IC's point of measurement (POM) or effective point of measurement (EPOM). However, residual discrepancies due to the energy dependency of the cylindrical chamber's EPOM caused remained. The LDM offers straightforward and efficient means for precision water surface identification, minimizing reliance on individual operator skills.

전문 발 관리실 이용자의 발 반사요법 인식수준 및 관련요인 (Perception Level of Foot Reflex Therapy and Its Related Factors among Customers using Foot Care Service Centers)

  • 김영호;김범호
    • 한국산학기술학회논문지
    • /
    • 제14권3호
    • /
    • pp.1350-1358
    • /
    • 2013
  • 본 연구는 발 반사마사지를 받는 이용자들의 발 반사요법에 대한 인식수준을 알아보고 그에 관련된 요인을 규명하고자 2011년 09월 01일부터 10월 30일까지의 기간 동안에 대전지역에 소재하고 있는 전문 발 관리실 3곳의 이용자 181명을 대상으로 구조화된 자기기입식 설문지를 이용한 설문조사를 실시하였다. 연구결과, 전체 조사대상자의 발 반사마사지요법 인식수준에 대한 평균점수는 $32.19{\pm}5.32$점(11개 항목의 점수범위; 0-44점)으로 나타났으며, 일반적 특성별 발 반사마사지요법 인식수준은 학력이 높을수록 유의하게 높았다(p=0.020). 조사대상자의 발 반사마사지 요법에 대한 태도 및 실천도에 따른 발 반사마사지요법 인식수준은 "질병치유를 위해서 한다"는 군에서(p=0.034), 발 반사마사지 시작 시 "질병이 있었다"는 군에서(p=0.030). 발 마사지 이용기간이 길수록(p=0.000), 발 반사마사지를 타인에게 "권유 하겠다"는 군에서 유의하게 높았다(p=0.004). 다중회귀분석 결과 발 반사마사지요법 인식수준에 영향을 미치는 관련요인으로는 발 반사마사지 이용 이유, 발 반사마사지 시작 시 건강상태, 발 반사마사지 이용기간 및 발 반사마사지의 타인에의 권유여부가 유의한 변수로 선정되었으며 이들 변수에 대한 설명력은 26.1%이었다. 위와 같은 결과를 볼 때, 전문 발 관리실 이용자들의 발 반사마사지요법 인식수준은 일반적 특성 변수들보다는 발 반사마사지에 대한 태도 및 실천도를 설명하는 변수들과 관련성이 높은 것을 알 수 있었다.