• Title/Summary/Keyword: PMSG(Permanent Magnet Synchronous Generator)

Search Result 88, Processing Time 0.026 seconds

Empirical Evaluation of Tidal Current Generation System at Ul-Dol-Mok in Jin-do (진도 울돌목 조류발전 시스템 실증 평가)

  • Moon, Seok-Hwan;Park, Byung-Gun;Kim, Ji-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.2
    • /
    • pp.157-163
    • /
    • 2016
  • The empirical evaluation of grid-connected tidal current generation system is presented in this paper. The Ul-dol-mok in Jin-do has been estimated to have tidal power of 1GW. In order to experiment, HAT (Horizontal Axis Turbine) 3-blade and 20kW grid-connected tidal current generation system was established at Ul-dol-mok in Jin-do. To generate power of generator, the speed reference of the PMSG is generated from the Cp curve and TSR (Tip Speed Ratio) of the designed turbine. The control of the converter connected to the grid is controlled to regulate unity power factor. The result showed that the turbine efficiency and system efficiency is 37 % and 31 %. This was achieved that target rate is 30 %, 20 %, respectively.

A Study on Design of Control Device on Small Wind Generator Using 2-Level Boost Converter (2레벨용 부스트 컨버터를 이용한 소형풍력발전기 제동장치 설계에 관한 연구)

  • Moon, Chae-Joo;Chang, Young-Hak;So, Soon-Youl;Park, Tae-Sik;Jeong, Moon-Seon;Youn, Young-Chan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1481-1486
    • /
    • 2013
  • The small wind generator with existing mechanical control system has a frequent failure and malfunction, and its maintenance is difficult. In this paper, an electric control method using a boost converter for small wind generator was suggested. The suggested 2-level boost converter control device was manufactured and its experimental operation were conducted on a wind generator with 200 [W] capacity. As a result of experimental device, the control by a boost converter was executed at the point that the output voltage of a wind generator became 36 [V] so it could be identified that the output voltage of a wind generator diminished and then it became 0 [V] after 5 [sec]. Besides, in case of applying the method suggested in this paper to a small wind power generation facility for street lights, it is expected to reduce its maintenance by preventing a frequent failure of a generator and to improve its utilization rate.

Pitching Motion Analysis of Floating Spar-buoy Wind Turbine of 2MW Direct-drive PMSG (2 MW 영구자석 직접 구동형 부유식 스파 부이 풍력 발전기의 피칭 운동해석)

  • Shin, Pyungho;Kyong, Namho;Choi, Jungchul;Ko, Heesang
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.1
    • /
    • pp.1-14
    • /
    • 2017
  • A series of coupled time domain simulations considering stochastic waves and wind based on five 1-h time-domain analyses are performed in normal operating conditions. Power performance and tower base Fore-Aft bending moment and pitching motion response of the floating spar-buoy wind turbine with 2 MW direct-drive PMSG have been analyzed by using HAWC2 that account for aero-hydro-servo-elastic time domain simulations. When the floating spar-buoy wind turbine is tilted in the wind direction, maximum of platform pitching motion is close to $4^{\circ}$. Statistical characteristics of tower base Fore-Aft bending moment of floating spar-buoy wind turbine are compared to that of land-based wind turbine. Maximum of tower base Fore-Aft bending moment of floating spar-buoy wind turbine and land-based wind is 94,448 kNm, 40,560 kNm respectively. This results is due to changes in blade pitch angle resulting from relative motion between wave and movement of the floating spar-buoy wind turbine.

Development of Torque simulator for the performance analysis of the 10kW wind turbine system (10kW 풍력발전기의 동작특성 분석을 위한 토크 시뮬레이터 개발)

  • Kim, Se-Yoon;Kim, Sung-Ho;Lee, Jong-Hee;Moon, Jin-Young
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.6
    • /
    • pp.579-585
    • /
    • 2014
  • 10kW wind turbine is widely studied in the field of renewable energy for the merits of easy installation to the confined area such as hill, park and urban areas. The performance of various electrical devices such as converter and inverter in the wind turbine system should be systematically analyzed for various wind speeds. However, it is impossible to apply these devices directly to practical wind turbine system for the safety of wind turbine system. Therefore, it is required to develop torque simulator which can generate corresponding torque according to its wind speed. In this work, 10kW torque simulator which consists of three phase torque control inverter, 3 phase induction motor and PMSG(Permanent Magnet Synchronous Generator) is developed.

Power Smoothening Control of Wind Farms Based on Inertial Effect of Wind Turbine Systems

  • Nguyen, Thanh Hai;Lee, Dong-Choon;Kang, Jong-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.1096-1103
    • /
    • 2014
  • This paper proposes a novel strategy for attenuating the output power fluctuation of the wind farm (WF) in a range of tens of seconds delivered to the grid, where the kinetic energy caused by the large inertia of the wind turbine systems is utilized. A control scheme of the two-level structure is applied to control the wind farm, which consists of a supervisory control of the wind farm and individual wind turbine controls. The supervisory control generates the output power reference of the wind farm, which is filtered out from the available power extracted from the wind by a low-pass filter (LPF). A lead-lag compensator is used for compensating for the phase delay of the output power reference compared with the available power. By this control strategy, when the reference power is lower than the maximum available power, some of individual wind turbines are operated in the storing mode of the kinetic energy by increasing the turbine speeds. Then, these individual wind turbines release the kinetic power by reducing the turbine speed, when the power command is higher than the available power. In addition, the pitch angle control systems of the wind turbines are also employed to limit the turbine speed not higher than the limitation value during the storing mode of kinetic energy. For coordinating the de-rated operation of the WT and the storing or releasing modes of the kinetic energy, the output power fluctuations are reduced by about 20%. The PSCAD/EMTDC simulations have been carried out for a 10-MW wind farm equipped with the permanent-magnet synchronous generator (PMSG) to verify the validity of the proposed method.

Compensation of Unbalanced PCC Voltage in Off-shore Wind Farms of PMSG Type Turbine

  • Kang, Jayoon;Han, Daesu;Suh, Yongsug;Jung, Byoungchang;Kim, Jeongjoong;Park, Jonghyung;Choi, Youngjoon
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.215-216
    • /
    • 2014
  • This paper proposes a control algorithm for permanent magnet synchronous generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage offshore wind power system under unbalanced grid conditions. The proposed control algorithm particularly compensates for the unbalanced grid voltage at the point of common coupling in a collector bus of offshore wind power system. This control algorithm has been formulated based on the symmetrical components in positive and negative rotating synchronous reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power are described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of ac input current is injected to the point of common coupling in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm makes it possible to provide a balanced voltage at the point of common coupling resulting in the generated power of high quality from offshore wind power system under unbalanced network conditions.

  • PDF

Design of Power and Load Reduction Controller for a Medium-Capacity Wind Turbine (중형 풍력터빈의 출력 및 타워 하중저감 제어기 설계)

  • Kim, Kwansu;Paek, Insu;Kim, Cheol-Jin;Kim, Hyun-Gyu;Kim, Hyoung-Gil
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.1-12
    • /
    • 2016
  • A control algorithm for a 100 kW wind turbine is designed in this study. The wind turbine is operating as a variable speed variable pitch (VSVP) status. Also, this wind turbine is a permanent magnet synchronous generator (PMSG) Type. For the medium capacity wind turbine considered in this study, it was found that the optimum tip speed ratios to achieve the maximum power coefficients varied with wind speeds. Therefore a commercial blade element momentum theory and multi-body dynamics based program was implemented to consider the variation of aerodynamic coefficients with respect to Reynolds numbers and to find out the power and thrust coefficients with respect tip speed ratio and blade pitch angles. In the end a basic power controller was designed for below rated, transition and above rated regions, and a load reduction algorithm was designed to reduce tower vibration by the nacelle motion. As a result, damage equivalent Load (DEL) of tower fore-aft has been reduced by 32%. From dynamic simulations in the commercial program, the controller was found to work properly as designed. Experimental validation of the control algorithm will be done in the future.

A design of Hybrid power generation system for Ocean facilities (해양시설물용 하이브리드 발전시스템 설계)

  • Jung, Sung-Young;Oh, Jin-Seok
    • Journal of Navigation and Port Research
    • /
    • v.33 no.6
    • /
    • pp.381-385
    • /
    • 2009
  • Generally power system of ocean facility composes a solar generation system.The power to be generated by the solar system is changed according to the amount of sunlight of weather conditions. Output power of solar system is decreased with weather condition such as cloudy day and rainy day. And the power shortage of the ocean facility can occur due to the lack of solar energy. To solve this problem, this paper proposes the power control system for solar-wave hybrid system Wave generation system consists of wells turbine and permanent magnet synchronous generator(PMSG). This propose system set the specific area and measures the solar generation power and wave generation power. As a result of experiment, the solar power is a more static source than wave power, but the wave power provides energy during periods of no sunshine. The power characteristic of propose hybrid system have been obtained high reliability than a solar generation system.