• 제목/요약/키워드: PMMA bone cement

검색결과 34건 처리시간 0.025초

인공무릎관절에 있어서 임플란트의 재료 및 고정방법에 따른 응력분석 (Stress Analysis of Total Knee System Depending on Implant Materials and Fixation Methods)

  • 조철형;조용균;최재봉;최귀원
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.484-488
    • /
    • 1997
  • Three-dimensional finite element analyses were used to compare the stress distribution and the stability of the fixation among seven different tibial components and to investigate the effect due to implant materials in total knee arthroplasty. The components included an intact tibia(Type I), Cemented Cobalt-Chromium tibial tray implanted with a PMMA cemented Co-Cr stem(Type II), Cemented Co-Cr tibial tray with a uncemented Co-Cr stem(Type III), Cemented Ultra High Molecular Weight Polyethylene (UHMWPE) tibial tray with a cemented UHMWPE stem (Type IV), Cemented UHMWPE tray with a uncemented UHMWPE stem(Type V), Cemented Co-Cr tray without a stem(Type VI), and Cemented UHMWPE tray without a stem(Type VII). Uncemented components were assumed to have complete bony in growth and a rigid state of fixation between component and bone. The interface between bone/cement/component of cemented components was also assumed to be fully bonded. Bi-condylar forces were applied. The results indicated that Uncemented stem components provided lower bone stress shielding and stress concentration. The UHMWPE tray and stem component showed better agreement with the intact tibia than the Co-Cr Alloy tray and stem components. If the implant tray can be fixed firmed without a stem, Cemented PE tray without a stem(Type VII) may be recommended to give the best characteristics in the sense of stress distribution and stability.

  • PDF

골 시멘트 중합 비율 변경이 척추성형술 치료에 미치는 영향에 대한 비교 분석 (A Micro Finite Element Analysis on Effects of Altering Monomer-to-Powder ]Ratio of Bone Cement During Vertebroplasty)

  • 김형도;탁계래;김한성
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권6호
    • /
    • pp.451-458
    • /
    • 2002
  • 골다공증이란 골량의 감소에 의해 야기되며. 해면골 미세구조의 골밀도가 감소하는 질병이다. 약물치료(부갑상선 호르몬)법은 골소주의 두께 및 골의 강도를 어느 정도 증가시킬 수 있는 호르몬 치료법이다. 척추성형술은 골다공성 척추 압박 골절의 치료를 위하여 척추 해면골에 주사기를 통하여 골 시멘트를 주입하는 최소 침습적 수술법이다. 임상적으로 골 시멘트의 물성치에 영향을 미치더라도 점성 감소와 주입 시간 확보를 위해 중합비율을 변경하여 사용한다. 본 연구의 목적은 골 시멘트 중합비율 변경에 따른 척추 해면골의 역학적 특성을 알아보고자 한다. 본 논문에서 는 수정된 보로노이 도형을 이용하여 척추 해면골의 유한요소 모델을 생성하고, 골 시멘트의 중합비율(0.40~l.07$m\ell$/g)에 따른 척추 해면골의 강도회복 정도를 비교하였다. 또한 골다공증 치료에서 호르몬 치료와 골 시멘트 치료의 상대적인 영향을 비교 분석하였다. 분석결과 골 시멘트 치료모델의 탄성계수와 강도는 정상 상태의 약 50%로 회복되었으며, 이 값은 호르몬 치료 모델의 약 2배이다. 0.53$m\ell$/g의 중합비율에서 골 시멘트의 탄성계수와 강도가 최고이며 1.07$m\ell$/g의 중합비율에서 최소의 탄성계수와 강도(각각 42%와 49%)이지만 약물 치료보다는 더 효과적임을 알 수 있다. 척추성형술시 제작사에서 추천하는 중합비율과 다른 비율을 사용할 경우 골 시멘트의 물성치 감소뿐만 아니라 환자의 골 밀도에 따라서 해면골의 강도회복에 문제가 발생할 수 있다는 것을 알 수 있었다.

PHILOS plate fixation with polymethyl methacrylate cement augmentation of an osteoporotic proximal humerus fracture

  • Kim, Do-Young;Kim, Tae-Yeong;Hwang, Jung-Taek
    • Clinics in Shoulder and Elbow
    • /
    • 제23권3호
    • /
    • pp.156-158
    • /
    • 2020
  • PHILOS plate fixation in osteoporotic proximal humerus fracture of old age is well-known for high complication rate, especially metal failure, providing various augmentation techniques, such as calcium phosphate cement, allogenous or autologous bone graft. We report a case of polymethyl methacrylate augmentation to provide appropriate reduction with a significant mechanical support. This can be a treatment option for displaced unstable osteoporotic proximal humerus fracture with marked bony defect.

Successful Carapace Puncture Wound Repair with Polymethyl Methacrylate (PMMA) in an Amur Softshell Turtle (Pelodiscus maackii)

  • Ha, Minjong;Lee, Do Na;Ahmed, Sohail;Han, Janghee;Yeon, Seong-Chan
    • 한국임상수의학회지
    • /
    • 제39권4호
    • /
    • pp.185-191
    • /
    • 2022
  • An Amur softshell turtle with multiple shell injuries was admitted to the Seoul Wildlife Center on 19 May 2021. The most severe lesion was a puncture wound requiring urgent closure. In addition to routine supportive therapy, the damaged shell was patched with biocompatible polymethyl methacrylate (PMMA) materials (bone cement and dental acrylic) and fiberglass. Despite a few methods to repair the carapace or plastron of hard-shelled turtles, shell repair in the Amur softshell turtle has rarely been reported. This paper reports the repair process of a puncture wound in the carapace of a softshell turtle using polymethyl methacrylate (PMMA). PMMA is a biocompatible acrylic polymer that forms a tight structure that holds the implant against tissue defects, such as skin, bones, and dentures. Fiberglass, a preferred fiber in various medical fields, was used with PMMA to provide extra strength and waterproof capability. After the procedure, there were no signs of edema, inflammation, bleeding, skin discoloration, or any other complications. Accordingly, this can be a method of choice in softshell turtles using biocompatible materials to cover the lesion in the carapace and provide appropriate wound management, supportive therapy, and a suitable course of antibiotics considering all other circumstances.

Bone ingrowth 향상을 위해 플라즈마 용사된 초내식성 오스테나이트 스테인리스강의 다공성 코팅층에 대한 연구 (A Study on Plasma Sprayed Porous Super Austenitic Stainless Steel Coating for Improvement of Bone Ingrowth)

  • 오근택;박용수
    • 한국표면공학회지
    • /
    • 제29권2호
    • /
    • pp.81-92
    • /
    • 1996
  • The cementless fixation of bone ingrowth by porous coatings on artificial hip joint prostheses are replacing polymethylmethacrylate(PMMA) bone cement fixations. However, the major interests in the field of porous metal coating are environmental corrosivity accelerated by metal ion release, deterioration in the mechanical property of the coating, and the mechanical failure of the coatings as well as the substrate. Therefore, the selection of right materials for coatings and the development of porous coating techniques must be accomplished. Because of the existing problems in Ti and Ti alloys which are used extensively, this study is focused on the plasma spraying technique for coating on super stainless steel substrate. In order to determine the optimum conditions which satisfy the requirement for the porous coatings, under the plasma spraying, we selected the experimental parameters which extensively influenced on the characteristics of the coating through the pre-examination. Spray distance has been selected among 120, 160, and 200mm and primary gas flow rate among 70, 100, and 130 SCFH. Current and secondary gas($H_2$) flow rate was fixed at 400A, and 15 SCFH respectively. To understand the characteristics of the coatings, surface morphology, cross-sectional micro-structure, surface roughness, residual stress, and corrosion resistance were elucidated and the best conditions for the bone ingrowth improvement on artificial hip joint prostheses were found.

  • PDF

The Analysis of Patterns and Risk Factors of Newly Developed Vertebral Compression Fractures after Percutaneous Vertebroplasty

  • Yoo, Chai Min;Park, Kyung Bum;Hwang, Soo Hyun;Kang, Dong Ho;Jung, Jin Myung;Park, In Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권4호
    • /
    • pp.339-345
    • /
    • 2012
  • Objective : The purpose of this study was to investigate the patterns and the risk factors of newly developed vertebral compression fractures (VCFs) after percutaneous vertebroplasty (PVP). Methods : We performed a retrospective review of the 244 patients treated with PVP from September 2006 to February 2011. Among these patients, we selected 49 patients with newly developed VCFs following PVP as the new VCFs group, and the remaining 195 patients as the no VCFs group. The new VCFs group was further divided into 2 groups : an adjacent fractures group and a nonadjacent fractures group. The following data were collected from the groups : age, gender, body weight/height, body mass index (BMI), bone mineral density (BMD) score of the spine and femur, level of initial fracture, restoration rate of anterior/middle vertebral height, and intradiscal cement leakage, volume of polymethylmethacrylate (PMMA). Results : Age, gender, mean body height/weight, mean BMI and volume of PMMA of each of the group are not statistically significantly associated with fractures. In comparison between the new VCFs group and the no VCFs group, lower BMD, intradiscal cement leakage and anterior vertebral height restoration were the significant predictive factors of the fracture. In addition, new VCFs occurrence at the adjacent spines was statistically significant, when the initial fracture levels were confined to the thoracolumbar junction, among the subgroups of new VCFs. Conclusion : Lower spinal BMD, the greater anterior vertebral height restoration rate and intradiscal cement leakage were confirmed as risk factors for newly formed VCFs after PVP.

반코마이신을 함유한 Polymethylmetacrylate 비드를 이용한 만성 골수염의 치험례 (THE USE OF VANCOMYCIN-IMPREGNATED POLYMETHYLMETACTYLATE BEADS FOR THE TREATMENT OF CHRONIC OSTEOMYELITIS)

  • 이형석;박영주;최동주;김미자;장계표;김정래;김선엽;안병근
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권6호
    • /
    • pp.672-676
    • /
    • 2000
  • One of the current treatment methods for chronic osteomyelitis is removal of the infected and necrotic tissue to reduce the bacterial concentration as much as possible. This is performed concomitantly with antibiotic therapy. Chronic osteomyelitis(C.O.) implies chronic ischemia of the diseased bone. Thus, the treatment for C.O. requires high systemic level of antibiotics. In some cases, however, inherent undesirable adverse effects(for example, nephrotoxicity, ototoxicity, and others) may render this course of treatment difficult. Knowing that residual monomers are released from hardened bone cement, installation of antibiotic-impregnated PMMA(polymethyl-methacrylate) beads in situ have been one of treatment methods of C.O. When introduced into the wound, they established an exceedingly high level of local antibiotics for prolonged period without high systemic level of antibiotics. We experienced favorable results with vancomycin-impregnated PMMA beads for the treatment of C.O. of the mandible. So, we report it with literature reviews.

  • PDF

Polymethylmethacrylate-Augmented Screw Fixation for Stabilization of the Osteoporotic Spine : A Three-Year Follow-Up of 37 Patients

  • Moon, Bong-Ju;Cho, Bo-Young;Choi, Eun-Young;Zhang, Ho-Yeol
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권4호
    • /
    • pp.305-311
    • /
    • 2009
  • Objective : The purpose of this study was to determine the efficacy, radiological findings, clinical outcomes and complications in patients with lumbar stenosis and osteoporosis after the use of polymethylmethacrylate (PMMA) augmentation of a cannulated pedicle screw. Methods : Thirty-seven patients with degenerative spinal stenosis and osteoporosis (T-score < -2.5) underwent lumbar fusion using the Dream Technology Pedicle Screw ($DTPS^{TM}$, Dream Spine Total Solutions, Dream STS, Seoul. Korea) between 2005 and 2007. The clinical outcomes were evaluated by using the visual analog scale (VAS) and the Prolo scale. Radiologic findings were documented through computed tomography (CT) and plain films. Results : Thirty-seven patients were evaluated and included, 2 males and 35 females with an average bone mineral density (BMD) of $0.47g/cm^2$. The average age of the patients was 68.7 (range, 57-88). The preoperative VAS for low back and leg pain ($7.87{\pm}0.95$ and $8.82{\pm}0.83$) were higher as compared with postoperative VAS ($2.30{\pm}1.61$ and $1.42{\pm}0.73$) with statistical significance (p = 0.006, p = 0.003). According to the Prolo scale, 11, 22, one and three patients were in excellent, good, fair and poor conditions, respectively. The average amount of the injected cement per one cannulated screw was $1.83{\pm}0.11\;mL$. Conclusion : The results show favorable outcome both clinically and radiographically for 37 patients who underwent lumbar fusion using $DTPS^{TM}$ and PMMA. Based on the results, the use of this surgical method can be a safe and effective option for the operation on the osteoporotic spine.

척추성형술이 인접 척추체에 미치는 영향 (The effects of vertebroplasty on adjacent vertebra)

  • 박정수;최철현;채수원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.746-750
    • /
    • 2007
  • Vertebroplasty has drawn much attention as a medical treatment for the compression fracture of spine, which strengthens the vertebral body and corrects deformity, and relieves pain in patients by injecting bone cement. However vertebroplasty can cause fracture on adjacent vertebra due to relative stiffness change. This study involves the biomechanical evaluation of the vertebroplasty especially on adjacent vertebral body. The finite element method has been employed to analyze the patient who was treated vertebroplasty under static and dynamic loading. For this study, a three-dimentioal model of the three-level ligamentous lumbar segment ($L1{\sim}L3$)is created from medical image data (CT)and compared with the experimental results in vitro.

  • PDF

대퇴골 전자간 골절의 새로운 수술기법에 관한 생체역학적 분석 (A Biomechanical Study on a New Surgical Procedure for the Treatment of Intertrochanteric Fractures in relation to Osteoporosis of Varying Degrees)

  • 김봉주;이성재;권순용;탁계래;이권용
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권5호
    • /
    • pp.401-410
    • /
    • 2003
  • 본 연구에서는 유한요소법을 이용하여 대퇴골 전자간 골절 치료에 대한 다양한 수술기법을 골밀도 변화에 따라 생체역학적으로 분석하여 이를 평가하고자 한다. 이에 구현된 모델들은 압박 고관절 나사만을 이용하여 시술한 모델 (Type I), 삽입된 압박 고관절 나사 주위에 시멘트 영역을 확보한 뒤 골 시멘트로 보강하는 시술을 구현한 모델 (Type II),대학교추가의 골소실이 없이 시멘트를 가압하여 주입하는 시술을 구현한 모델 (TypeIII)의 3가지 형태로 구현하였다. 시술 상황에 따라 골절부위와 삽입물의 경계면 주위에 접촉요소를 사용하기 위해 적절한 마찰계수를 설정하였으며, 골다공증 정도 (Singh Indices, II∼V)에 따라 대퇴골의 물성치를 적절하게 적용시켰다. 각 모델에 있어 골밀도 변화에 따른 수술기법의 차이를 분석하기 위하여 다음과 같은 인자를 분석하였다 : (a) 대퇴골두 내에서의 von Mises 응력 부피비, (b) 대퇴골두 망상골과 인공 삽입물내에서의 최대 von Mises 응력 (PVMS), (c) 대퇴골두 내에서의 최대 von Mises 변형률 (MVMS), (d) 골절 부위와 인공 삽입물 주위에서의 미세운동량. 수술기법 중 Type III가 대퇴골두 내에서 골밀도 변화에 상관없이 가장 낮은 PVMS, MVMS 수치를 보여 가장 효율적인 결과를 나타내었다. 이는 기존 시술법 (Type I,II)에 비해 내고정 실패 가능성이 가장 적을 것으로 예측되었다. 특히, 골밀도가 낮을 때에는 Type III의 수술 효과가 더욱 커지는 것으로 나타났다. 또한, 삽입물 주위에서 미세운동량을 분석한 결과, Type III의 수치가 다른 시술법들의 15∼20%로 나타나 시멘트를 가 압하여 보강하는 시술법이 삽입물 주위의 미세운동을 억제하는데 있어 가장 효과적이다는 것을 증명하는 것이다. 이러한 결과로부터, 압박 고관절 나사를 이용한 대퇴골두 전자간 골절 치료에 있어 골 시멘트를 가압하여 보강하는 방법이 골밀도가 낮은 환자에 있어 인공삽입물의 내고정 및 골유합에 가장 큰 효과를 보일 것으로 사료된다.