DOI QR코드

DOI QR Code

The Analysis of Patterns and Risk Factors of Newly Developed Vertebral Compression Fractures after Percutaneous Vertebroplasty

  • Yoo, Chai Min (Department of Neurosurgery, Gyeongsang National University School of Medicine) ;
  • Park, Kyung Bum (Department of Neurosurgery, Gyeongsang National University School of Medicine) ;
  • Hwang, Soo Hyun (Department of Neurosurgery, Gyeongsang National University School of Medicine) ;
  • Kang, Dong Ho (Department of Neurosurgery, Gyeongsang National University School of Medicine) ;
  • Jung, Jin Myung (Department of Neurosurgery, Gyeongsang National University School of Medicine) ;
  • Park, In Sung (Department of Neurosurgery, Gyeongsang National University School of Medicine)
  • Received : 2012.03.16
  • Accepted : 2012.10.04
  • Published : 2012.10.28

Abstract

Objective : The purpose of this study was to investigate the patterns and the risk factors of newly developed vertebral compression fractures (VCFs) after percutaneous vertebroplasty (PVP). Methods : We performed a retrospective review of the 244 patients treated with PVP from September 2006 to February 2011. Among these patients, we selected 49 patients with newly developed VCFs following PVP as the new VCFs group, and the remaining 195 patients as the no VCFs group. The new VCFs group was further divided into 2 groups : an adjacent fractures group and a nonadjacent fractures group. The following data were collected from the groups : age, gender, body weight/height, body mass index (BMI), bone mineral density (BMD) score of the spine and femur, level of initial fracture, restoration rate of anterior/middle vertebral height, and intradiscal cement leakage, volume of polymethylmethacrylate (PMMA). Results : Age, gender, mean body height/weight, mean BMI and volume of PMMA of each of the group are not statistically significantly associated with fractures. In comparison between the new VCFs group and the no VCFs group, lower BMD, intradiscal cement leakage and anterior vertebral height restoration were the significant predictive factors of the fracture. In addition, new VCFs occurrence at the adjacent spines was statistically significant, when the initial fracture levels were confined to the thoracolumbar junction, among the subgroups of new VCFs. Conclusion : Lower spinal BMD, the greater anterior vertebral height restoration rate and intradiscal cement leakage were confirmed as risk factors for newly formed VCFs after PVP.

Keywords

References

  1. Ahn Y, Lee JH, Lee HY, Lee SH, Keem SH : Predictive factors for subsequent vertebral fracture after percutaneous vertebroplasty. J Neurosurg Spine 9 : 129-136, 2008 https://doi.org/10.3171/SPI/2008/9/8/129
  2. Amar AP, Larsen DW, Esnaashari N, Albuquerque FC, Lavine SD, Teitelbaum GP : Percutaneous transpedicular polymethylmethacrylate vertebroplasty for the treatment of spinal compression fractures. Neurosurgery 49 : 1105-1114; discussion 1114-1115, 2001
  3. Ananthakrishnan D, Berven S, Deviren V, Cheng K, Lotz JC, Xu Z, et al. : The effect on anterior column loading due to different vertebral augmentation techniques. Clin Biomech (Bristol, Avon) 20 : 25-31, 2005 https://doi.org/10.1016/j.clinbiomech.2004.09.004
  4. Baroud G, Heini P, Nemes J, Bohner M, Ferguson S, Steffen T : Biomechanical explanation of adjacent fractures following vertebroplasty. Radiology 229 : 606-607; author reply 607-608, 2003 https://doi.org/10.1148/radiol.2292030378
  5. Belkoff SM, Mathis JM, Jasper LE, Deramond H : The biomechanics of vertebroplasty. The effect of cement volume on mechanical behavior. Spine (Phila Pa 1976) 26 : 1537-1541, 2001 https://doi.org/10.1097/00007632-200107150-00007
  6. Berlemann U, Ferguson SJ, Nolte LP, Heini PF : Adjacent vertebral failure after vertebroplasty. A biomechanical investigation. J Bone Joint Surg Br 84 : 748-752, 2002 https://doi.org/10.1302/0301-620X.84B5.11841
  7. Deramond H, Depriester C, Toussaint P, Galibert P : Percutaneous vertebroplasty. Seminars in Musculoskeletal Radiology, 1997, Vol 1, pp285-296 https://doi.org/10.1055/s-2008-1080150
  8. Fujiwara S, Kasagi F, Yamada M, Kodama K : Risk factors for hip fracture in a Japanese cohort. J Bone Miner Res 12 : 998-1004, 1997 https://doi.org/10.1359/jbmr.1997.12.7.998
  9. Galibert P, Deramond H, Rosat P, Le Gars D : [Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty]. Neurochirurgie 33 : 166-168, 1987
  10. Garfin SR, Yuan HA, Reiley MA : New technologies in spine : kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures. Spine (Phila Pa 1976) 26 : 1511-1515, 2001 https://doi.org/10.1097/00007632-200107150-00002
  11. Grados F, Depriester C, Cayrolle G, Hardy N, Deramond H, Fardellone P : Long-term observations of vertebral osteoporotic fractures treated by percutaneous vertebroplasty. Rheumatology (Oxford) 39 : 1410- 1414, 2000 https://doi.org/10.1093/rheumatology/39.12.1410
  12. Heini PF, Wälchli B, Berlemann U : Percutaneous transpedicular verteunionbroplasty with PMMA : operative technique and early results. A prospective study for the treatment of osteoporotic compression fractures. Eur Spine J 9 : 445-450, 2000 https://doi.org/10.1007/s005860000182
  13. Hodler J, Peck D, Gilula LA : Midterm outcome after vertebroplasty : predictive value of technical and patient-related factors. Radiology 227 : 662-668, 2003 https://doi.org/10.1148/radiol.2273011930
  14. Jensen ME, Evans AJ, Mathis JM, Kallmes DF, Cloft HJ, Dion JE : Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures : technical aspects. AJNR Am J Neuroradiol 18 : 1897-1904, 1997
  15. Kaufmann TJ, Trout AT, Kallmes DF : The effects of cement volume on clinical outcomes of percutaneous vertebroplasty. AJNR Am J Neuroradiol 27 : 1933-1937, 2006
  16. Kim SH, Kang HS, Choi JA, Ahn JM : Risk factors of new compression fractures in adjacent vertebrae after percutaneous vertebroplasty. Acta Radiol 45 : 440-445, 2004 https://doi.org/10.1080/02841850410005615
  17. Komemushi A, Tanigawa N, Kariya S, Kojima H, Shomura Y, Komemushi S, et al. : Percutaneous vertebroplasty for osteoporotic compression fracture : multivariate study of predictors of new vertebral body fracture. Cardiovasc Intervent Radiol 29 : 580-585, 2006 https://doi.org/10.1007/s00270-005-0138-5
  18. Lin EP, Ekholm S, Hiwatashi A, Westesson PL : Vertebroplasty : cement leakage into the disc increases the risk of new fracture of adjacent vertebral body. AJNR Am J Neuroradiol 25 : 175-180, 2004
  19. Lin WC, Cheng TT, Lee YC, Wang TN, Cheng YF, Lui CC, et al. : New vertebral osteoporotic compression fractures after percutaneous vertebroplasty : retrospective analysis of risk factors. J Vasc Interv Radiol 19 : 225-231, 2008 https://doi.org/10.1016/j.jvir.2007.09.008
  20. Lindsay R, Burge RT, Strauss DM : One year outcomes and costs following a vertebral fracture. Osteoporos Int 16 : 78-85, 2005 https://doi.org/10.1007/s00198-004-1646-x
  21. Lindsay R, Silverman SL, Cooper C, Hanley DA, Barton I, Broy SB, et al. : Risk of new vertebral fracture in the year following a fracture. JAMA 285 : 320-323, 2001 https://doi.org/10.1001/jama.285.3.320
  22. Mirovsky Y, Anekstein Y, Shalmon E, Peer A : Vacuum clefts of the vertebral bodies. AJNR Am J Neuroradiol 26 : 1634-1640, 2005
  23. Pope MH : Biomechanics of the lumbar spine. Ann Med 21 : 347-351, 1989 https://doi.org/10.3109/07853898909149219
  24. Ross PD, Davis JW, Epstein RS, Wasnich RD : Pre-existing fractures and bone mass predict vertebral fracture incidence in women. Ann Intern Med 114 : 919-923, 1991 https://doi.org/10.7326/0003-4819-114-11-919
  25. Syed MI, Patel NA, Jan S, Harron MS, Morar K, Shaikh A : Intradiskal extravasation with low-volume cement filling in percutaneous vertebroplasty. AJNR Am J Neuroradiol 26 : 2397-2401, 2005
  26. Thomas T, Barou O, Vico L, Alexandre C, Lafage-Proust MH : Recurrence of vertebral fracture with cyclical etidronate therapy in osteoporosis : histomorphometry and X-Ray microanalysis evaluation. J Bone Miner Res 14 : 198-205, 1999 https://doi.org/10.1359/jbmr.1999.14.2.198
  27. Trout AT, Kallmes DF, Kaufmann TJ : New fractures after vertebroplasty : adjacent fractures occur significantly sooner. AJNR Am J Neuroradiol 27 : 217-223, 2006
  28. Uppin AA, Hirsch JA, Centenera LV, Pfiefer BA, Pazianos AG, Choi IS : Occurrence of new vertebral body fracture after percutaneous vertebroplasty in patients with osteoporosis. Radiology 226 : 119-124, 2003 https://doi.org/10.1148/radiol.2261011911
  29. Winking M, Stahl JP, Oertel M, Schnettler R, Böker DK : Treatment of pain from osteoporotic vertebral collapse by percutaneous PMMA vertebroplasty. Acta Neurochir (Wien) 146 : 469-476, 2004 https://doi.org/10.1007/s00701-004-0259-7

Cited by

  1. Risk Factors for New Vertebral Compression Fractures After Percutaneous Vertebroplasty : Qualitative Evidence Synthesized From a Systematic Review vol.38, pp.12, 2012, https://doi.org/10.1097/brs.0b013e31828cf15b
  2. Risk Factors for Subsequent Fracture after Osteoporotic Vertebral Compression Fracture vol.9, pp.2, 2013, https://doi.org/10.13004/kjnt.2013.9.2.120
  3. Cement Leakage in Percutaneous Vertebroplasty for Spinal Metastases: A Retrospective Evaluation of Incidence and Risk Factors vol.39, pp.5, 2012, https://doi.org/10.1097/brs.0000000000000134
  4. Risk factors for new vertebral compression fractures after vertebroplasty: a meta‐analysis vol.86, pp.7, 2016, https://doi.org/10.1111/ans.13428
  5. Letter to the Editor concerning “Risk factors of new symptomatic vertebral compression fractures in osteoporotic patients undergone percutaneous vertebroplasty” by HL. Ren et al. (Eur Spin vol.26, pp.5, 2012, https://doi.org/10.1007/s00586-017-5022-x
  6. Effect of zoledronic acid on lumbar spinal fusion in osteoporotic patients vol.26, pp.11, 2012, https://doi.org/10.1007/s00586-017-5286-1
  7. Clinical outcome comparison of polymethylmethacrylate bone cement with and without mineralized collagen modification for osteoporotic vertebral compression fractures vol.97, pp.37, 2012, https://doi.org/10.1097/md.0000000000012204
  8. Clinical application of the pedicle in vitro restorer in percutaneous kyphoplasty vol.13, pp.None, 2018, https://doi.org/10.1186/s13018-018-0978-8
  9. Percutaneous Vertebroplasty Does Not Increase the Incidence of New Fractures in Adjacent and Nonadjacent Vertebral Bodies vol.32, pp.2, 2012, https://doi.org/10.1097/bsd.0000000000000734
  10. Letter : A Retrospective Analysis in 1347 Patients Undergoing Cement Augmentation for Osteoporotic Vertebral Compression Fracture Is the Sandwich Vertebra at a Higher Risk of Further Fracture? vol.88, pp.6, 2012, https://doi.org/10.1093/neuros/nyab067
  11. A study on the relationship between the rate of vertebral body height loss before balloon kyphoplasty and early adjacent vertebral fracture vol.34, pp.4, 2012, https://doi.org/10.3233/bmr-200121
  12. Does prophylactic vertebral augmentation reduce the refracture rate in osteoporotic vertebral fracture patients: a meta-analysis vol.30, pp.9, 2012, https://doi.org/10.1007/s00586-021-06899-w
  13. What are risk factors for subsequent fracture after vertebral augmentation in patients with thoracolumbar osteoporotic vertebral fractures vol.22, pp.1, 2021, https://doi.org/10.1186/s12891-021-04946-7