• 제목/요약/키워드: PM concentration

검색결과 4,284건 처리시간 0.033초

서울시 미세먼지 농도의 지역적 특성파악을 위한 연구 - 구별 분포 특성 및 차량등록대수와의 관계 - (Understanding on Regional Characteristics of Particular Matter in Seoul - Distribution of Concentration in Borough Spatial Area and Relation with the Number of Registered Vehicles -)

  • 박종길;최윤정;정우식
    • 한국환경과학회지
    • /
    • 제26권1호
    • /
    • pp.55-65
    • /
    • 2017
  • Average concentration of PM in Seoul metropolitan area satisfied the Korean air quality standard in 2010. Furthermore, concentration of PM in all boroughs across Seoul met the air environment standard in 2012. $PM_{10}$ concentration was relatively higher in center of Seoul in comparison to the rest, while $PM_{2.5}$ concentration showed exactly the contrary result. We analyzed the effect that PM emissions from vehicles would have on PM concentrations across Seoul. The results showed that average annual PM concentration recently decreased in Seoul although the number of vehicles registered annually continued its upward trend. By contrast, average fine dust concentrations in Seoul showed a decline which suggested that correlation between annual average PM concentrations and number of registered vehicles remained low. However, year-on-year vehicle registration rate recently showed a declining tendency in the same way as the trend of changes in average PM concentrations. Particularly, the upward trend in annual average PM concentrations in 2002 and 2007 was consistent with the increase in vehicle registration rate, suggesting that vehicle registration rate was closely associated with changes in PM concentrations.

시정자료를 이용한 황사의 미세먼지 농도추정 방법 연구 (Study of Methodology for Estimating PM10 Concentration of Asian Dust Using Visibility Data)

  • 이효정;이은희;이상삼;김승범
    • 대기
    • /
    • 제22권1호
    • /
    • pp.13-28
    • /
    • 2012
  • The $PM_{10}$ concentration data is useful for indentifying intensity and a transport way of Asian dust. However, it is difficult to identify them properly due to the limited spatial resolution and coverage. Therefore, a methodology to estimate $PM_{10}$ concentration using visibility data obtained from synoptic observation was developed. To derive the converting function, correlation between visibility and $PM_{10}$ concentration is investigated using visibility and $PM_{10}$ concentration data observed at 20 stations in Korea from 2005 to 2009. To minimize bias due to atmospheric moisture, data with higher relative humidity over a critical value were eliminated while deriving $PM_{10}$-visibility relationship. As a result, an exponentially decreasing function of visibility is obtained under the condition that relative humidity is less than 82%. Verification of the visibility converting function to $PM_{10}$ concentration was carried out for the dust cases in 2010. It was found that spatial distributions of $PM_{10}$ calculated by visibility are in good agreement with the observed $PM_{10}$ distribution, especially for the strong dust cases in 2010. And correlation between the derived and observed $PM_{10}$ concentration was 0.63. We applied the function to obtain distributions of $PM_{10}$ concentration over North Korea, in which concentration data are not available, and compared them with satellite derived dust index, IODI distributions for dust cases in 2010. It is shown that the visibility function estimates quite similar patterns of dust concentration with IODI image, which suggests that it can contribute for prediction by indentifying transport route of Asian dust.

부산지역 겨울철 고농도 미세먼지 발생일의 기상학적 특성 (Meteorological Characteristics of the Wintertime High PM10 Concentration Episodes in Busan)

  • 전병일
    • 한국환경과학회지
    • /
    • 제21권7호
    • /
    • pp.815-824
    • /
    • 2012
  • The purpose of this study was to analyze the meteorological characteristics of wintertime high PM10 concentration episodes in Busan. $PM_{10}$ concentration has been reduced for the past four years and recorded near or exceeded 100 ${\mu}g/m^3$ (national standard of $PM_{10}$). High concentration episodes in Busan were 6 case, $PM_{2.5}/PM_{10}$ ratio was 0.36~0.39(mean 0.55). High $PM_{10}$ concentration occurred during higher air temperature, more solar radiation and sunshine, lower relative humidity, and smaller cloud amount. Synoptically, it also occurred when Busan was in the center or the edge of anticyclone and when sea breeze intruded. An analysis of upper air sounding showed that high $PM_{10}$ concentration occurred when surface inversion layer and upper subsidence inversion layer existed, and when boundary layer depth and vertical mixing coefficient were low. An analysis of backward trajectory of air mass showed that high $PM_{10}$ concentration was largely affected by long range transport considering that it occurs when air mass is intruded from China.

부산 구덕산 미세먼지의 금속성분 및 이온성분 농도 특성 (Characteristics of Metallic and Ionic Elements Concentration in PM10 at Guducsan in Busan)

  • 전병일
    • 한국환경과학회지
    • /
    • 제25권5호
    • /
    • pp.715-726
    • /
    • 2016
  • This study investigates the characteristics of metallic and ionic elements concentration, concentration according to transport path, and factor analysis in $PM_{10}$ at Guducsan in Busan in the springtime of 2015. $PM_{10}$ concentration in Guducsan and Gwaebeopdong were $59.5{\pm}9.04{\mu}g/m^3$ and $87.5{\pm}20.2{\mu}g/m^3$, respectively. Contribution rate of water-soluble ions and secondary ion in $PM_{10}$ concentration in Guducsan were 37.0% and 27.8% respectively. [$NO_3{^-}/SO{_4}^{2-}$] ratio and contribution rate of sea salt of $PM_{10}$ in Guducsan and Gwaebeopdong were 0.91 and 1.12, 7.0% and 5.3%, respectively. The results of the backward trajectory analysis indicates that $PM_{10}$ concentration, total inorganic water-soluble ions and total secondary ions were high when the air parcels moved from Sandong region in China than non-Sandong and northen China to Busan area. The results of the factor analysis at Guducsan indicates that factor 1 was anthropogenic source effects such as automobile emissions and industrial combustion processes, factor 2 was marine sources such as sea salts from sea, and factor 3 was soil component sources.

부산지역 PM10과 PM2.5 중의 금속 농도와 이온농도 특성 (Characteristics of Metallic and Ionic Concentrations in PM10 and PM2.5 in Busan)

  • 전병일;황용식
    • 한국환경과학회지
    • /
    • 제23권5호
    • /
    • pp.819-827
    • /
    • 2014
  • This study analyzes the chemical composition of metallic elements and water-soluble ions in $PM_{10}$ and $PM_{2.5}$. $PM_{10}$ and $PM_{2.5}$ concentrations in Busan during 2010-2012 were $97.2{\pm}67.5$ and $67.5{\pm}32.8{\mu}g/m^3$, respectively, and the mean $PM_{2.5}/PM_{10}$ concentration ratio was 0.73. The contribution rate of water-soluble ions to $PM_{10}$ ranged from 29.0% to 58.6%(a mean of 38.6%) and that to $PM_{2.5}$ ranged from 33.9% to 58.4%(a mean of 43.1%). The contribution rate of sea salt to $PM_{10}$ was 13.9% for 2011 and 9.7% for 2012, while that to $PM_{2.5}$ was 17.4% for 2011 and 10.1% for 2012. $PM_{10}$ concentration during Asian dust events was $334.3{\mu}g/m^3$ and $113.3{\mu}g/m^3$ during non-Asian dust events, and the $PM_{10}$ concentration ratio of Asian Dust/Non Asian dust was 2.95. On the other hand, the $PM_{2.5}$ concentration in Asian dust was $157.4{\mu}g/m^3$ and $83.2{\mu}g/m^3$ in Non Asian dust, and the $PM_{2.5}$ concentration ratio of Asian Dust/Non Asian dust was 1.89, which was lower than that of $PM_{10}$.

Carassius auratus(goldfish)를 이용한 BPMC와 Carbaryl의 생물농축계수의 측정 (Determination of Bioconcentration Factor on BPMC and Carbaryl in Carassius auratus(goldfish))

  • 박선열;민경진;강회양
    • 한국환경보건학회지
    • /
    • 제20권1호
    • /
    • pp.75-82
    • /
    • 1994
  • Bioconcentration Factor (BCF) is known as important criteria for ecotoxicology on hazardous chemicals. But there is no standard method for determining BCF and reported BCFs were slightly different in accordance with authors. This study was performed with aims to determine BCFs on BPMC and Carbaryl. Carassius auratus(goldfish) be chosen as test organism and test period were 3-day, 5-day and 10-day. Extract solvents were n-hexane and acetonitrile. GC-ECD was used to detecting carbamates. The obtained results were as follows: 1. It was possible to determine short term BCF$_s$ of Carbaryl or BPMC through relatively simple procedure. 2. BCF$_3$ of Carbaryl in concentration of 1, 2, 5, 10 ppm were 0.34 $\pm$ 0.06, 0.18 $\pm$ 0.02, 0.10 $\pm$ 0.01, 0.06 $\pm$ 0.01 respectively. BCF$_5$ of Carbaryl were 0.34 $\pm$ 0.05, 0.18 $\pm$ 0.02, 0.13 $\pm$ 0.01 and 0.07 $\pm$ 0.01, BCF$_{10}3$ of Carbaryl were 0.45 $\pm$ 0.05, 0.27 $\pm$ 0.02, 0.16 $\pm$ 0.02 and 0.09 $\pm$ 0.01. BCF$_3$ of BPMC in concentration of 1, 2, 5 ppm were 4.66 $\pm$ 0.17, 2.64 $\pm$ 0.49, 1.88 $\pm$ 0.24 respectively. BCF$_5$ of BPMC were 4.09 $\pm$ 0.50, 2.42 $\pm$ 0.37 and 1.83 $\pm$ 0.15. 3. BCF$_s$ of BPMC were decreased as increasing concentration. However, BPMC concentration in fish were increased in contrast to BCF. But more concentrated BPMC was found in fish 3-day test than found concentration in fish 5-day test. 4. Same trend appeared in Carbaryl. BCF$_s$ of Carbaryl were decreased as increasing concentration and prolonging test period. But found Carbaryl concentration in fish were increased. 5. BCF$_s$ of BPMC were higher than that of Carbaryl by 10 times, in spite of the physicochemical properties of the two carbamates were similar to each other. Further study is recommended to find out the reason of the difference.

  • PDF

시정을 이용하여 추정한 1982~2014년 서울과 춘천의 PM2.5 농도 변화 추이 (Using visibility to estimate PM2.5 concentration trends in Seoul and Chuncheon from 1982 to 2014)

  • 이용희;곽경환
    • 한국대기환경학회지
    • /
    • 제34권1호
    • /
    • pp.156-165
    • /
    • 2018
  • Long-term trend analysis on air pollutant concentrations is very important to diagnose the present status and plan for the future. In this study, the long-term trends of $PM_{2.5}$ concentrations were estimated based on the relationship between the visibility and $PM_{2.5}$ concentration regarding the effects of relative humidity in Seoul and Chuncheon. The relationships between the visibility and $PM_{2.5}$ concentration were derived from the measurement data in 2015 and 2016. Then, the annual trends of $PM_{2.5}$ concentration from 1982 to 2014 were estimated and compared to those of $PM_{10}$ concentration available in Seoul and Chuncheon. During the estimation process, four ranges of relative humidity were considered such as less than 30%, 31~50%, 51~70%, and 71~90%. In Seoul and Chuncheon, the visibility and $PM_{2.5}$ concentration generally have the inverse relationship while the visibility decreases as the relative humidity increases. The estimated $PM_{2.5}$ concentrations similarly showed the decreasing tendencies from 2006 to 2012 in Seoul and Chuncheon. However, the estimated $PM_{2.5}$ concentrations showed the increasing tendency before 2005 in Chuncheon in contrast to the decreasing tendency in Seoul. This implies that the long-term trends of $PM_{2.5}$ concentration in different cities in South Korea reflect the local influencing factors. For example, 'Special Act on the Improvement of Atmospheric Environment in the Seoul Metropolitan Area' can affect the different long-term trends in Seoul and Chuncheon. The estimated $PM_{2.5}$ concentrations were validated with the measured ones in Seoul and Chuncheon. While the general tendencies were well matched between the estimated and measured concentrations, the $PM_{2.5}$ concentration trends in 1990s and their monthly variations are needed to be improved quantitatively using more reference data for longer years.

시·공간적 풍계에 따른 부산지역 고농도 PM2.5의 일변화 특성 (Characteristics of Diurnal Variation of High PM2.5 Concentration by Spatio-Temporal Wind System in Busan, Korea)

  • 김부경;이동인;김정창;이준호
    • 한국지구과학회지
    • /
    • 제33권6호
    • /
    • pp.469-480
    • /
    • 2012
  • 본 연구는 3년(2005. 12. 1-2008. 11. 30) 동안 부산의 $PM_{2.5}$ 대기오염자동관측소(장림동: 공업지역, 좌동: 주거지역) 측정자료 중 고농도 $PM_{2.5}$(24시간 환경기준 $50{\mu}g/m^3$)에 대한 $PM_{2.5}$$PM_{2.5}/PM_{10}$ 농도비의 일변화 특성과 함께 시 공간적 풍계(풍향 및 풍속)에 따른 특성을 분석하고자 하였다. 고농도 $PM_{2.5}$는 장림동과 좌동 각각 182일 및 27일이었다. 장림동에서 고농도 $PM_{2.5}$의 시간평균농도 및 $PM_{2.5}/PM_{10}$ 농도비의 일변화는 모든 계절에서 오후에 비해 새벽과 오전 및 야간에 높은 비슷한 패턴을 나타내었다. 좌동의 여름 주간에 $PM_{2.5}/PM_{10}$ 농도비가 증가하는 것은 해양조건에서 광화학반응에 의해 생성되는 이차 입자상물질 중 $PM_{10}$의 거대입자 농도가 미세입자인 $PM_{2.5}$ 농도보다 더 감소하기 때문이다. 시간대별로 시 공간적 풍계(풍향 및 풍속등급) 특성을 분석하였다. 그 결과, 고농도 $PM_{2.5}$는 장림동에서 공업단지의 산업활동에 의한 오염물질 정체와 주변지역의 오염물질 이동에 의해 발생되었다. 좌동에서는 주로 주거와 상업활동으로 인한 지역적 오염물질 정체로 발생하는 것으로 나타났다.

다중이용시설의 위생상태에 관한 조사연구 (A Study on the Sanitation Condition of Public Facility)

  • 김종오;정용택
    • 환경위생공학
    • /
    • 제24권1호
    • /
    • pp.47-55
    • /
    • 2009
  • Indoor air Quality in public facility same as bus terminal and subway station is very important for civil health. The purpose of this study was to investigate the concentration and distribution of PM10 and falling microorganism at the 5 subway stations and bus terminals from Summer 2003 to Summer 2005 in Kyunggi Province. The results were as follows. 1. The highest concentration of PM10 was $187ug/m^3$ at Bucheon Bus Terminal in 2005 while the lowest concentration of PM10 was $78ug/m^3$ at Suwon Bus Terminal in 2003. The year variation of PM10 concentration at the bus terminals in Kyunggi Province was in order of 2005 > 2004 > 2003. The average concentration of PM10 at the five Bus Terminal was $127ug/m^3$. 2. The highest concentration of PM10 was $225ug/m^3$ at Euijungbu Station l in 2004 while the lowest concentration of PM10 was $115ug/m^3$ at Suwon Station in 2003. The year variation of PM10 at the subway stations in Kyunggi Province was in order of 2004 > 2005 > 2003. The average concentration of PM10 at the five subway stations was $164ug/m^3$. 3. The average amount of falling microoganism at the five bus terminal in Kyunggi Provinc was 201CFU/plate. The minimum is 124 CFU/plate at Seongnam Bus Terminal in 2004 while the maximum is 268CFU/plate at Euijungbu Bus Terminal in summer 2005. The higher concentration of PM10 was 206CFU/plate in 2004 than 199CFU/plate in 2003 and 2005. 4. The minimum is 107CFU/plate at Anyang station in 2003 while the maximum was 263CFU/plate at Euijungbu station in 2003. The average amount of falling microoganism at the five subway stations in Kyunggi Province was 179 CFU/plate. The year variation of falling microorganism at the subway stations in Kyunggi Province was in order of 2004 > 2005 > 2003.

Carbamate계 농약의 생체농축계수 측정 (Determination of Bioconcentration Factor on Carbamates)

  • 민경진
    • 한국환경보건학회지
    • /
    • 제20권4호
    • /
    • pp.80-89
    • /
    • 1994
  • It was reported that BCF's (Bioconcentration Factor) on Carbaryl and BPMC in concentration of 1, 2, 5 and 10 ppm, previously. Carassius auratus(goldfish) was chosen as test organism. Carbamates in fish and in test water were extracted with n-hexane and acetonitrile. GC-ECD was used to detecting and quantitating of Carbamates. Also, partition coefficients were determined with Stir flask method. To evaluate environmental toxicological profiles of tested compounds, experimental concentration were 0.05, 0.1 and 0.5 ppm in contrast to previous report. It was considered that higher BCFs of BPMC due to its higher partition coefficient compared to Carbaryl. The obtained results were as follows: 1. It was possible to determine short term BCF of Carbaryl and BPMC through relatively simple procedure in environmental concentrations. 2. BCF$_3$ of Carbaryl in concentration of 0.05, 0.1 and 0.5 ppm were 4.666 $\pm$ 0.002, 3.622 $\pm$ 0.004, 1.200 $\pm$ 0.002 and BCF$_5$ were 3.897 $\pm$ 0.005, 4.219 $\pm$ 0.017 and 1.186 $\pm$ 0.054, respectively. In the case of BPMC in same condition, BCF$_3$ were 4.077 $\pm$ 0.014, 4.900 $\pm$ 0.005, 4.750 $\pm$ 0.009 and BCF$_5$ were 3.465 $\pm$ 0.010, 4.612 $\pm$ 0.011 and 4.075 $\pm$ 0.012, respectively. 3. Carbaryl concentration in fish extract was increased as increasing test concentration, but BCF were decreased as prolonging test period, especially dropped at 0.5 ppm. 4. In the case of BPMC, BCF were decreased as increasing test concentration, but the concentration in fish extract of 3-day test group was slightly higher than that of 5-day test group. 5. Higher BPMC concentration in fish extract was due to its higher partition coefficient to compared with Carbaryl. 6. Determined logP of Carbaryl and BPMC were 2.200 and 3.180. But the calculated BCF using suggested equation was so different that predict BCF. It is suggested that BCF's of Carbamates have to be determined by experiment.

  • PDF