• Title/Summary/Keyword: PM Point

Search Result 1,374, Processing Time 0.03 seconds

NEW PHOTOMETRIC PIPELINE TO EXPLORE TEMPORAL AND SPATIAL VARIABILITY WITH KMTNET DEEP-SOUTH OBSERVATIONS

  • Chang, Seo-Won;Byun, Yong-Ik;Shin, Min-Su;Yi, Hahn;Kim, Myung-Jin;Moon, Hong-Kyu;Choi, Young-Jun;Cha, Sang-Mok;Lee, Yongseok
    • Journal of The Korean Astronomical Society
    • /
    • v.51 no.5
    • /
    • pp.129-142
    • /
    • 2018
  • The DEEP-South (the Deep Ecliptic Patrol of the Southern Sky) photometric census of small Solar System bodies produces massive time-series data of variable, transient or moving objects as a by-product. To fully investigate unexplored variable phenomena, we present an application of multi-aperture photometry and FastBit indexing techniques for faster access to a portion of the DEEP-South year-one data. Our new pipeline is designed to perform automated point source detection, robust high-precision photometry and calibration of non-crowded fields which have overlap with previously surveyed areas. In this paper, we show some examples of catalog-based variability searches to find new variable stars and to recover targeted asteroids. We discover 21 new periodic variables with period ranging between 0.1 and 31 days, including four eclipsing binary systems (detached, over-contact, and ellipsoidal variables), one white dwarf/M dwarf pair candidate, and rotating variable stars. We also recover astrometry (< ${\pm}1-2$ arcsec level accuracy) and photometry of two targeted near-earth asteroids, 2006 DZ169 and 1996 SK, along with the small- (~0.12 mag) and relatively large-amplitude (~0.5 mag) variations of their dominant rotational signals in R-band.

Analysis of air pollution in subway area of Busan Metropolitan City (부산광역시 지하철역 지하공간의 대기오염 특성)

  • Lee, Hwa-Woon;Jang, Nan-Sim;Kwak, Jin;Lee, Hee-Ryung;Kim, Hee-Man
    • Journal of Environmental Science International
    • /
    • v.11 no.3
    • /
    • pp.169-176
    • /
    • 2002
  • The purpose of this study is designed to estimate the air quality of subway stations that have the underground platforms in Pusan Metropolitan City, from September to November 2000, over seven times. The subjects include Yonsan-dong station, Somyon station, Pusan station, Nampo-dong station, and Tushil station. The samplings were conducted at three points of each station, i.e. gate, ticket gates, and platforms. The major materials for analysis were CO, NO, NO$_2$, and $O_3$. The experiment was conducted at 7:00 pm with KIMOTO HS-seven Handy sampler and Tedlar Bag of SKC INC(U.S.A). In order to more fully understand station environments, we also measured temperature at each point. The results showed that $O_3$ average concentration at Yonsan-dong station was higher than others with 38~51 ppb. The average concentration of NO was high at ticket gate and platform at Somyon station(119 ppb, 122 ppb), Nampo-dong station(102 ppb, 100 ppb). These results show that the air pollution of stations with underground shopping malls was higher than others. At Somyon station having a junction station, NO and NO$_2$ concentration level of platform-2(noncrowded) was higher than platform-1(crowded). This is most likely due to the accumulation of air pollutants and inadequate ventilation systems.

The 100Watt Unit Power Amplifier Using Temperature Independent Biasing for DTV Repeater Application (Temperature Independent Biasing을 사용한 DTV 중계기용 100Watt급 단위 전력증폭기의 구현)

  • Lee, Young-Sub;Jeon, Joong-Sung;Lee, Seok-Jeong;Ye, Byeong-Duck;Hong, Tchang-Hee
    • Journal of Navigation and Port Research
    • /
    • v.26 no.2
    • /
    • pp.215-220
    • /
    • 2002
  • In this paper, the 100 watt unit ower amplifier using temperature independent biasing for DTV (Digital Television) repeater application is designed and fabricated. The DC operation point of this unit power amplifier at temperature variation from $20^{\circ}C$ to $100^{\circ}C$ is fixed by active bias circuit. The variation of current consumption in the 100 watt unit power amplifier has an excellent characteristics of less than 0.6A. The implemented unit power amplifier has the gain over 12dB, the gain flatness of less than 0.5dB and input and output return, loss of than 15dB over the DTV repeater frequency range (470~806MHz). This unit power amplifier yields intermodulation distortion(IMD) of more than 32dBc at 2MHz offset, which satisfies the IMD at output power of 100 watt (50dBm).

A Study on Flux Barrier of Permanent Magnet Assisted Reluctance Synchronous Motor Design using FEM (FEM을 이용한 영구자석형 릴럭턴스 동기전동기의 자속 장벽 설계에 대한 연구)

  • Kim, Nam-Hun;Nam, Sang-Hyun;Choi, Kyeong-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.295-302
    • /
    • 2008
  • This paper examines the design and the performance of a PMA-RSM(permanent-magnet assisted reluctance synchronous motor) for washing machine. A FEM(finite element method) is used to analyze performance and maximum torque characteristic of the proposed PMA-RSM. The designed motor is a combination of salient poles, which is making reluctance torque, and permanent magnet which are located on the air-gap of rotor to get a enough torque during low speed resign. Typical flux barrier type reluctance synchronous motor and the effects of adding magnet into the flux barrier of the rotor of a PMA-RSM are compared and examined. Also the maximum torque point of the reluctance torque by reluctance and reaction torque by magnetic alignment torque, which is in barrier, of the proposed PMS-RSM are derived through simulation. Using this results, the characteristics analysis of a performance, an average torque and a torque ripple of flux barrier RSM and the proposed PMA-RSM are performed through FEM under the saturation effect respectively.

Development of a High-Resolution Electrocardiography for the Detection of Late Potentials (Late Potential의 검출을 위한 고해상도 심전계의 개발)

  • 우응제;박승훈
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.449-458
    • /
    • 1996
  • Most of the conventional electrocardiowaphs foil to detect signals other than P-QRS-T due to the limited SNR and bandwidth. High-resolution electrocardiography(HRECG) provides better SNR and wider bandwidth for the detection of micro-potentials with higher frequency components such as vontricular late potentials(LP). We have developed a HRECG using uncorrected XYZ lead for the detection of LPs. The overall gain of the amplifier is 4000 and the bandwidth is 0.5-300Hz without using 60Hz notch filter. Three 16-bit A/D converters sample X, Y, and Z signals simultaneously with a sampling frequency of 2000Hz. Sampled data are transmitted to a PC via a DMA-controlled, optically-coupled serial communication channel. In order to further reduce the noise, we implemented a signal averaging algorithm that averaged many instances of aligned beats. The beat alignment was carried out through the use of a template matching technique that finds a location maximizing cross-correlation with a given beat tem- plate. Beat alignment error was reduced to $\pm$0.25ms. FIR high-pass filter with cut-off frequency of 40Hz was applied to remove the low frequency components of the averaged X, Y, and Z signals. QRS onset and end point were determined from the vector magnitude of the sigrlaIL and some parameters needed to detect the existence of LP were estimated. The entire system was designed for the easy application of the future research topics including the optimal lead system, filter design, new parameter extraction, etc. In the developed HRECG, without signal averaging, the noise level was less than 5$\mu$V$_rms RTI$. With signal averaging of at least 100 beats, the noise level was reduced to 0.5$\mu$V$_rms RTI$, which is low enough to detect LPs. The developed HRECG will provide a new advanced functionality to interpretive ECG analyzers.

  • PDF

A Study on the Sound Quality Improvement Using the Equal Compensation Filter in Bark-scale for the Cross-talk Cancellation (크로스토크 제거를 위한 바크스케일 등가 보상 필터를 이용한 음질 향상에 관한 연구)

  • Kim, Hack-Jin;Kim, Soon-Hyub
    • The KIPS Transactions:PartB
    • /
    • v.11B no.3
    • /
    • pp.345-352
    • /
    • 2004
  • This paper deals a method to deliver more realistic sound by cancelling the cross-talk which is inherent to the 5.1 channel speaker system. The acoustical model for cross-talk cancellation is the free field model. This model minimizes distortion of sound. 1 used the bark scale sound quality compensation which based on psycho-acoustic. For the surround channels, band-limited sound quality compensation is performed in the frequency domain. I also performed the sound qualify assessment test on the traditional 2 channel stereo and 5.1 channel system. This test is performed in the tort chamber which satisfies the ITU-R specifications. 1 uses the IACC(Inter-Aural Cross-Correlation) to determine the preferences of the amateur and the golden ear experts to asses the trans-aural filter. According to the result from the proposed method, I got more the 38dB separation rates with the Dolby standard speaker array. The results on the diffusion by the subjective test with the experts shows 0.4∼0.5 point Increased then before.

Strengthening of conventional dental glass ionomer cement by addition of chitosan powders with low or high molecular weight (저/고분자량 키토산에 의한 종래형 치과용 글라스아이오노머 시멘트의 강화)

  • Kim, Dong-Ae;Kim, Gyu-Ri;Jun, Soo-Kyung;Lee, Jung-Hwan;Lee, Hae-Hyoung
    • Korean Journal of Dental Materials
    • /
    • v.44 no.1
    • /
    • pp.69-77
    • /
    • 2017
  • The aim of this study was to investigate the effects of chitosan powder addition on the strengthening of conventional glass ionomer cement. Two types of chitosan powders with different molecular weight were mixed with conventional glass ionomer cement (GIC): low-molecular weight chitosan (CL; 50~190 kDa), high-molecular weight chitosan (CH; 310~375 kDa). The chitosan powders (CL and CH) were separately added into the GIC liquid (0.25-0.5 wt%) under magnetic stirring, or mixed with the GIC powder by ball-milling for 24 h using zirconia balls. The mixing ratio of prepared cement was 2:1 for powder to liquid. Net setting time of cements was measured by ISO 9917-1. The specimens for the compressive strength (CS; $4{\times}6mm$), diametral tensile strength (DTS; $6{\times}4mm$), three-point flexure (FS; $2{\times}2{\times}25mm$) with flexure modulus (FM) were obtained from cements at 1, 7, and 14 days after storing in distilled water at $(37{\pm}1)^{\circ}C$. All mechanical strength tests were conducted with a cross-head speed of 1 mm/min. Data were statistically analyzed by one-way ANOVA and Tukey HSD post-hoc test. The mechanical properties of conventional glass ionomer cement was significantly enhanced by addition of 0.5 wt% CL to cement liquid (CS, DTS), or by addition of 10 wt% CH (FS) to cement powder. The CL particles incorporated into the set cement were firmly bonded to the GIC matrix (SEM). Within the limitation of this study, the results indicated that chitosan powders can be successfully added to enhance the mechanical properties of conventional GIC.

A Study on the Simulation of Non-Point Pollutant in Hapcheon Dam Watershed Using HSPF Model (HSPF 모델을 이용한 합천댐 유역의 비점오염물질 유출 모의 방안에 대한 연구)

  • Cho, Hyun Kyung;Kim, Sang Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.421-421
    • /
    • 2019
  • 본 연구의 목적은 HSPF 모델을 이용하여 비점오염물질이 수질에 미치는 영향을 평가하는 것이다. 합천댐 유역을 연구대상지역으로 선정하였으며, 입력자료는 유역도, 하천도, 토지이용도, 수치표고모델 및 기상자료 등을 이용하였다. HSPF 모형은 2000년부터 2016년까지의 실측값을 이용하여 보정 및 검증이 이루어졌다. 수문 보정을 위한 매개변수는 사용자 설명서와 참고문헌에 근거하여 선정하였으며, 시행착오법에 의해 수행되었다. 모델의 적용성 평가는 $R^2$, RMSE, RMAE, NSE를 사용하였고 $R^2$가 0.78에서 0.83, RMSE는 2.55에서 2.76mm/day, RMAE는 0.46에서 0.48mm/day, NSE는 0.81에서 0.82까지의 범위로 나타났으며, 연간 유출량이 ${\pm}4%$ 오차 이내로 산정되었다. 수질 모형을 구동하기 위한 수질 자료는 환경부에서 제시한 지침에 따라 생활계, 축산계, 산업계, 토지이용량에 따른 발생 부하량과 배출부하량을 산정하였다. 수질 모형 또한 수문과 같은 기간의 자료를 이용하여 보정 및 검정이 이루어졌다. 보정 결과 연평균 BOD의 차이가 0.22mg/L이고 오차범위는 13%였으며, T-N과 T-P는 0.66mg/L, 0.027mg/L의 차이를 가지며 오차범위는 각각 16%, 13%로 나타났다. 수질항목 중에서도 비점오염 관리의 효과를 평가하기 위해 비점오염물질 중 가장 큰 비중을 차지하는 축산계에 감소 시나리오를 적용하였다. 축산계의 배출부하량 감소율이 20%일때의 BOD, T-N, T-P는 각각 3%, 1%, 3% 감소하였으며 40% 감소율을 적용하였을때는 5%, 3%, 4% 감소하였다. 이러한 수질 해석을 결과를 토대로 효과적인 오염물질 방법을 적용하여 수질 개선과 합천댐 유역의 목표수질을 달성 할 수 있을 것으로 판단된다.

  • PDF

Characterization of Atmospheric Dispersion Pattern from Large Sources in Chungnam, Korea (충남지역 대형사업장의 대기오염물질 확산 특성 파악)

  • Choi, Woo Yeong;Park, Min Ha;Jung, Chang Hoon;Kim, Yong Pyo;Lee, Ji Yi
    • Particle and aerosol research
    • /
    • v.17 no.3
    • /
    • pp.55-69
    • /
    • 2021
  • Chungnam region accounts for the largest SOX (22.8%) emission with the second-largest NOX (10.8%) emission in Korea due to the integration of many large industrial sources including a steel mill, coal-fired power plants, and petrochemical complex. Air pollutants emitted by large industrial sources can cause harmful problems to humans and the environment. Thus, it is necessary to understand dispersion patterns of air pollutants from large industrial sources in Chungnam to characterize atmospheric contamination in Chungnam and the surrounding area. In this study, seasonal atmospheric dispersion characteristics for SOX, NOX, and PM2.5 from ten major point sources in Chungnam were evaluated using HYSPLIT 4 model, and their contributions to SO2, NO2 concentrations in the regions near the source areas were estimated. The predictions of the HYSPLIT 4 model show a seasonal different dispersion pattern, in which air pollutants were dispersed toward the southeast in winter while, northeast in summer. In summer, due to weaker wind speed, air pollutants concentrations were higher than in winter, and they were dispersed to the metropolitan area. The local emissions of air pollutants in Taean area had a greater influence on the ambient SO2 and NO2 concentrations at Taean, whereas SOX and NOX emissions from large sources located at Seosan showed relatevely little effect on the ambient ambient SO2 and NO2 concentrations at Seosan.

A Study on the Correlationship between Wearable ECG and Clinical ECG Measurements (웨어러블 심전도 측정과 임상 심전도 측정과의 상관관계에 대한 연구)

  • Lee, Kang-Hwi;Lee, Seong-Su;Kim, Sang-Min;Lee, Hyeok-Jae;Min, Kyoung-Jin;Kang, Hyun-Kyu;Lee, Joo-Hyeon;Kwak, Hwy-Kuen;Ko, Yun-Soo;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1690-1698
    • /
    • 2018
  • Recent advances in ICT technology have transformed many of our daily lives and attracted a lot of attention to personal health. Heart beat measurement that reflects cardiac activities has been used in various fields such as exercise evaluation and psychological state evaluation for a long time, but its utilization method is limited due to its differentiation from clinical electrocardiogram. Therefore, in this study, we could observe the change of the measured signal according to the change of the distance and the position of the measuring electrodes which are non-standard electrode configuration. Based on the electric dipole model of the heart, correlation with clinical electrocardiogram could be confirmed by synthesizing multiple surface potentials measured with a shorter electrode distance than standard one. From the electromagnetic point of view, the distance between the measuring electrodes corresponds to the distance that the electric potential by the cardiac electric dipole moves, and the electric potential measured at the body surface is proportional to the moving distance of the electric potential. Therefore, it is preferable to make the distance between electrodes as long as possible, and to position the measuring electrode close to the ventricle rather than the atrium. In addition, it was found that standard electrocardiographic waveforms could be synthesized by using arithmetic sum of multiple measuring electrodes due to the relationship of electrical dipole vectors, which is obtained by dividing and positioning a plurality of measuring electrodes on a reference electrode line, such as Lead-I, Lead-II direction. Also, we obtained a significant Pearson correlation coefficient ($r=0.9113{\pm}0.0169$) as a result of synthetic experiments on four subjects.