Kim, Young-Sung;Jeong, Jung-Il;Kim, Jae-Chul;Cho, Sung-Min
Proceedings of the KIEE Conference
/
2007.07a
/
pp.533-534
/
2007
This paper investigates impulsive noise from a pole transformer in low voltage distribution system for power line communication. EMI noise from the pole transformer is indicated from the experiment. The noise has certain characteristics because it is caused by partial discharge. The noise level is above -35dBm without a filter. Therefore, the filter which is made of ferrite is used in order to eliminate the noise. the noise filters should be applied to both the phase line and the neutral line. Otherwise, It is likely to have little overall impact on elimination of noises. the performance of filter is verified with various experiments. In conclusion, the equivalent circuit of power line communication including noise source is described as a lumped circuit.
Moon K. H.;Shin M. C.;Seo H. S.;Choi S. Y.;Choi I. H.;Kim H. M.;Hur N. Y.;Cha J. S.
Proceedings of the KIEE Conference
/
summer
/
pp.313-315
/
2004
최근의 전력선통신(PLC: Power Line Communication)은 협대역인 450KHz에서 광대역인 30MHz로 확대되어 고속의 데이터 전송이 가능하게 되었다[1]. 본 논문에서는 광대역 채널특성과 더불어 고속의 데이터 전송까지 가능하도록 하기 위해 새로운M-ary SS(spread spectrum) 기반의 고속 전력선통신시스템을 제시하고 임펄스잡음과 같은 전력선 채널환경 하에서의 BER(Bite Error Rate)특성에 대한 모의실험을 거쳐서 제안 방식의 유용성을 확인하였다
Cha J. S.;Shin M. C.;Seo H. S.;Choi S. Y.;Kweon G. B.;Choi I. H.;Kim H. M.;Moon K. H.
Proceedings of the KIEE Conference
/
summer
/
pp.327-329
/
2004
전력선통신(PLC : Power Line Communication)은 실제 네트워크를 작성할 수 있는 이점은 있지만 이로 인해서 말단의 망 구성이 복잡해지고 여러 부하 장치들의 사용과 운용이 시간과 공간에 따라 전송 특성이 수시로 가변 하는 특성을 가지게 된다. 이러한 특성은 통신시스템 성능상의 다중 경로페이딩의 지연과 성분을 가지게 되므로, 열악한 통신 채널 환경 띤 다중 사용자 간섭에 의한 원인이 된다. 본 논문에서는 이런 원인을 극복하기 위한 한 가지방편으로서, 저간섭 전력선 통신에 적용 가능한 이진 ZCD 확산 코드를 제시하고, 상관 특성을 도출해 봄으로서, 그 유효성을 확인한다.
Proceedings of the Korean Institute of Information and Commucation Sciences Conference
/
2014.05a
/
pp.921-922
/
2014
에너지 절약과 에너지 재생산 측면에 있어서 일상생활에서 낭비되고 있는 에너지를 다시 회수하여 재사용 할 수 있는 시스템은 경제적인 측면에서 그 가치가 높다고 할 수 있다. 이러한 관점에서 일반 주유소나 도장시설 등과 같은 환경에서 무심히 대기로 배출되는 휘발성 유증기를 포집하여 다시 에너지로 재사용하게 되면 경제적인 효과가 높다고 할 수 있다. 본 논문은 기존의 PLC 기반으로 동작하고 있는 휘발성유기화합물에 대한 액화장치(Liquefaction equipment)를 정보통신기술(Information & Communication Technology)을 접목시켜 액화장치를 효율적으로 관리하고, 내부 액화온도를 적절하게 제어하여 액화기의 효율을 향상시키고자 한다. 또한 액화기의 운전상태에 대한 정보를 ZigBee 기반의 무선 통신기술을 도입하여 원격지 관리서버로 액화기 상태정보를 전송하여 액화기에 대한 합리적인 운전 스케쥴 관리와 에너지 생산성을 높이고자 하며, 스마트기기로 모니터링 할 수 있도록 액화장치의 정보를 제공하고자 한다.
The Motion controllers provide the sophisticated performance and enhanced capabilities we can see in the movements of robotic systems. Several types of motion controllers are available, some based on the kind of overall control system in use. PLC (Programmable Logic Controller)-based motion controllers still predominate. The many peoples use MCU (Micro Controller Unit)-based board level motion controllers and will continue to in the near-term future. These motion controllers control a variety motor system like robotic systems. Generally, They consist of large and complex circuits. PLC-based motion controller consists of high performance PLC, development tool, and application specific software. It can be cause to generate several problems that are large size and space, much cabling, and additional high coasts. MCU-based motion controller consists of memories like ROM and RAM, I/O interface ports, and decoder in order to operate MCU. Additionally, it needs DPRAM to communicate with host PC, counter to get position information of motor by using encoder signal, additional circuits to control servo, and application specific software to generate a various velocity profiles. It can be causes to generate several problems that are overall system complexity, large size and space, much cabling, large power consumption and additional high costs. Also, it needs much times to calculate velocity profile because of generating by software method and don't generate various velocity profiles like arbitrary velocity profile. Therefore, It is hard to generate expected various velocity profiles. And further, to embed real-time OS (Operating System) is considered for more reliable motion control. In this paper, the structure of chip-based precision motion controller is proposed to solve above-mentioned problems of control systems. This proposed motion controller is designed with a FPGA (Field Programmable Gate Arrays) by using the VHDL (Very high speed integrated circuit Hardware Description Language) and Handel-C that is program language for deign hardware. This motion controller consists of Velocity Profile Generator (VPG) part to generate expected various velocity profiles, PCI Interface part to communicate with host PC, Feedback Counter part to get position information by using encoder signal, Clock Generator to generate expected various clock signal, Controller part to control position of motor with generated velocity profile and position information, and Data Converter part to convert and transmit compatible data to D/A converter.
The Transactions of The Korean Institute of Electrical Engineers
/
v.59
no.11
/
pp.2043-2047
/
2010
This study is to solve problems of depletion of RF bandwidth frequency, confusion possibility, security that current wireless communications system have and is to confirm possibility of applying next generation network. To solve problems of current wireless communications system, visible light communications system for power line communications using ATmega16 Microcontroller is was realized and receiver property was analyzed. PLC exclusive chip APLC-485MA, Microcontroller ATmega16, 5pi bulb type LED and high flux LED, visible light receiving sensor LLS08-A1 were used for transmitter and receiver. Performance was analyzed by designed program and an oscilloscope. It was showed average 20% improved receiver rate rather than bulb type LED in the case of high flux LED through voltage change rate on communication distance and LED type of distance between 10 to 50 cm. The blue LED showed the best performance among measured LED types with above 10% of voltage decreasing rate. But As it gradually becomes more distant, the precise date was difficult to obtain due to weak light. To overcome these sort of problems, specific values such as changing conditions and efficiency value relevant to light emitting parts and visible light receiving sensor should be calculated and continuous study and improvements should also be accomplished for the better communications condition.
Kim, Gwan-Hyung;Kang, Sung-In;Jeon, Jae-Hwan;Kwon, Oh-Hyun;Oh, Am-Suk;Cho, Hyun-Cheol
Proceedings of the Korean Institute of Information and Commucation Sciences Conference
/
2010.10a
/
pp.577-578
/
2010
The current marine communication networks are usually composed of NMEA0183, NMEA2000, and MiTS protocols which are located on the physical layer based on RS-422, RS-485, CAN, and EtherNet. This paper proposes a new bridge based on the DC power line communication technique supported from the NMEA0183 to design inside marine systems.
Kim, Kwan-Kyu;Yeom, Keong-Tae;Kim, Kwan-Woong;Kim, Yong-Kab
The Journal of the Korea Contents Association
/
v.8
no.6
/
pp.1-7
/
2008
The paper is to solve the problem of existing sound system, which has difficulties of system organization and the increase of additional install cost and unfriendly interior. To solve the existing system, we drew the new sound system based on PLC and studied it. A transmitter and a receiver were designed using the PLC chip INT5500CS. Sound system was configured with a CD player that sound signals are sent from the transmitter and a speaker connected to the receiver. For analysis of characteristics of this system, a USBPre external sound card and Smaart Live 5 which is a PC-based sound measuring program were added. As a result of our experiment, the measured signal level is $2{\sim}3$[dB] lower than reference signal, latency is 16.69[ms] and the specific character of coherency is bad in high frequency band. Otherwise, this system transmits and receives signals over 90[%] in good condition as a result of measuring pink noise, frequency(1kHz), and phase, magnitude. In view of the result so far achieved, the system designed our team has excellent performance, it resolves defect of existing audio signal transmition system.
The Journal of Korea Institute of Information, Electronics, and Communication Technology
/
v.9
no.3
/
pp.285-290
/
2016
In rural area, our farmers confront decreasing benefits owing to imported crops and increased cost. Recently, the government encourage the 6th Industry that merges farming, rural resources, and information and communication technology. Therefor the government makes an investment in supplying 'smart greenhouse' in which a farmer monitor growing crops and environment information to control growing condition. The objective of this study is developing an Moving Monitor and Control System for crops in green House. This system includes a movable sensing unit, a controlling unit, and a server PC unit. The movable sensing unit contains high resolution IP camera, temperature and humidity sensor and WiFi repeater. It rolls on a rail hanging beneath the ceiling of a green house. The controlling unit contains embedded PC, PLC module, WiFi router, and BLDC motor to drive the movable sensing unit. And the server PC unit contains a integrated farm management software and home pages and databases in which the images of crops and environment informations. The movable sensing unit moves widely in a green house and gathers lots of information. The server saves these informations and provides them to customers with the direct commercing web page. This system will help farmers to control house environment and sales their crops in online market. Eventually It will be helpful for farmers to increase their benefits.
The Journal of The Korea Institute of Intelligent Transport Systems
/
v.10
no.1
/
pp.124-130
/
2011
In this paper, we propose a method for the efficient power use in power outage. The cost is high and conversion into the other function is difficult since the terminal used in conventional home network system has a dedicated function. This method is based on home network system employed with photovoltaic system. Throughout the modularization of the terminal, the variable function and cost reduction can be achieved. Additionally the unit cost can be reduced by using the power line communication. The prototype of light-control terminal has been implemented. The experimental results with the terminal show the performance of light-control system and the possibility of the commercialization can be achieved.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.