• Title/Summary/Keyword: PLC(power line communication)

Search Result 278, Processing Time 0.02 seconds

Vertex Coloring based Slot Reuse Scheduling for Power Line Communications

  • Yoon, Sung-Guk
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2135-2141
    • /
    • 2015
  • Power line communication (PLC) is one of the major communication technologies in smart grid since it combines good communication capability with easy and simple deployment. As a power network can be modeled as a graph, we propose a vertex coloring based slot reuse scheduling in the time division multiple access (TDMA) period for PLCs. Our objective is to minimize the number of assigned time slots, while satisfying the quality of service (QoS) requirement of each station. Since the scheduling problem is NP-hard, we propose an efficient heuristic scheduling, which consists of repeated vertex coloring and slot reuse improvement algorithms. The simulation results confirm that the proposed algorithm significantly reduces the total number of time slots.

Power Line Communication for Electronic Vehicle Systems (전기차 시스템을 위한 전력선 통신)

  • Park, Jae Jung;Kim, Yun Hyun;Kim, Jin Young;Seo, Jong Kwan;Lee, Jae Jo
    • Journal of Satellite, Information and Communications
    • /
    • v.7 no.2
    • /
    • pp.13-17
    • /
    • 2012
  • In recent years, type of the car is changing. Instead of cars that use internal combustion engines, we will use mainly eco-friendly electric vehicles. However, the utilization of electric vehicles brings enormous increase of power consumption. Thus, efficient power management and intelligent power consumption is required. Demand response can be effective measures of power consumption. In this paper, we present demand response technology applications, communication method, PLC application and simulation result.

Zigbee & PLC Integrated Gateway Development for U-Health Care Environment and Intelligent Home Network (유비쿼터스 헬스케어 환경 및 지능형 홈 네트워크를 위한 Zigbee & PLC 통합 게이트웨이 개발)

  • Son, Hui-Bae;Kim, Sung-Yun;Rhee, Young-Chul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.4
    • /
    • pp.73-80
    • /
    • 2009
  • In this paper, we implemented the integrated gateway for health care and home network system based on PLC(Power Line Communication) and Zigbee. The designed system is consists of sensors, integrated gateway, Zigbee module and PLC modem. The integrated gateway will transmit the data which is collected by health care sensors to health care control system and control an appliance for comfortable environment to medical facilities. The implemented gateway can support various health care and home network service.

  • PDF

A Design of Wavelet OFDM based on CIC Filter (CIC 필터를 이용한 Wavelet OFDM 설계)

  • Moon, Ki-Tak;Jang, Dong-Won;Kim, Kyung-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.2C
    • /
    • pp.93-98
    • /
    • 2011
  • Currently, The new communication system was very important because of the increasing demand for Internet access. One of these alternatives is the PLC. But, Power Line is not suitable for communication. So, electromagnetic wave is generated from Power Line during flow of communication information. And the electromagnetic wave is interfered with Wireless Communication Service using the same frequency range. To eliminate this interference by used Notch tilter. Wavelet OFDM in another way, while one is used. In this paper, Wavelet OFDM CIC filter used in the CMFB structure by applying a further lowering the value of the side-lobe is proposed to improve performance.

Implementation of dimming system using FH/SS Power Line Communication modem (FH방식의 전력선 모뎀에 의한 집단 조광제어 시스템 구현)

  • Choi Won-ho;Park Jun-yong;No Kyoung-ho;Park Chong-yeon
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.163-166
    • /
    • 2004
  • The conventional fluorescent lamp dimming system using an another control line is complex and will increased the cost. Therefore, many studies have focused on the wireless communication, but it is not fit for dimming system because of the interference generated by the infra-red light of lamp or switching noises in ballast. So, we applied the power line communication on the dimming system and we proposed a new coupling circuit using the voltage controlled impedance convertor for improving the performance of the FH/SS PLC modem. The performance for the proposed modem is evaluted by the BER.

  • PDF

Robust Approach for Channel Estimation in Power Line Communication

  • Huang, Jiyan;Wang, Peng;Wan, Qun
    • Journal of Communications and Networks
    • /
    • v.14 no.3
    • /
    • pp.237-242
    • /
    • 2012
  • One of the major problems for accurate channel estimation in power line communication systems is impulsive noise. Traditional channel estimation algorithms are based on the assumption of Gaussian noise, or the need to locate the positions of impulsive noise. The algorithms may lose optimality when impulsive noise exists in the channel, or if the location estimation of impulsive noise is inaccurate. In the present paper, an effective channel estimation algorithm based on a robust cost function is proposed to mitigate impulsive noise. The proposed method can provide a closed-form solution, and the application of robust estimation theory enables the proposed method to be free from localization of impulsive noise and thus can guarantee that the proposed method has better performance. Simulations verified the proposed algorithm.

Power Line Communication-based Heated Glass Temperature Control System (전력선통신을 이용한 선박 및 건축용 발열유리 온도제어 시스템)

  • Lee, Su-Hyeong;Kim, In-Dong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.2
    • /
    • pp.105-114
    • /
    • 2015
  • Heated glasses are widely used to prevent surface condensation and freezing in ship and building windows. This study proposes a heated glass temperature control system composed of power and control circuits to control the temperature of heated glasses. The proposed temperature control system adopts a digital controller instead of a conventional analog controller. Thus, the proposed system has better characteristics, such as precise setup and control of glass temperature, setup and control of output power, and control mode change between ON/OFF and phase controls. The system can also implement multi-functional control algorithms. The control characteristics are not dependent upon external disturbances, such as ambient temperature and electrical noises. Furthermore, the proposed temperature control system utilizes the power line communication (PLC) method to control the number of heated glasses without any extra communication lines. The system proposes a new communication protocol with strong immunity to electrical switching noises. A new sensorless algorithm is used to detect the temperature of the heated glass. This study presents the design guidelines in detail and its effectiveness are confirmed by implementing a 4-kw prototype temperature control system.

A Design of Foundation Technology for PLC-based Smart-grave(Tumulus) System

  • Huh, Jun-Ho;Koh, Taehoon;Seo, Kyungryong
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.11
    • /
    • pp.1319-1331
    • /
    • 2015
  • In the Republic of Korea, there's been a culture called 'Hyo' since Koryo Dynasty and this word represents the meaning of paying utmost respects to one's own parents and ancestors whether they are alive or have passed. However, nowadays, most of people live away from their family gravesites so that they do not and cannot take care of them except on the special holidays. For this reason, people could not respond promptly to the incidents occurred at the sites as they receive notifications much later dates most of the time. Thus, in this paper, we propose a low-cost gravesite monitoring system which the users can immediately respond to the disastrous events after being informed of current situations through PLC without delay. For the performance evaluation, the lab and test bed experiments were performed on an actual ship using 200Mbps and 500Mbps products instead of performing an on-site experiment after the system has actually been constructed. The Mountain Region PLC was installed on the power lines and the result showed successful 36.14Mbps communication. Therefore, we expect that this study will contribute in time and cost reduction while constructing the internet infrastructures in mountain regions or building the Smart-graves, tumulus, and charnel houses.

Implementation of Integrated Interface based on Wire and Wireless Dual Network for Ensuring the Reliability of Intelligent LED Lighting System (지능형 LED 조명 시스템의 신뢰성 확보를 위한 유무선 이중망 통합 인터페이스 구현)

  • Lee, Un-Seon;Park, Tae-Jin;Park, Man-Gon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.306-312
    • /
    • 2014
  • The ZigBee communication method, which is the most frequently applied to the LED lighting control system, has drawbacks of low-speed and low-capacity, and the communication failure possibility due to environmental influences is on the rise. Therefore, it is important to secure the communication reliability by applying an integrated interface with a wire-wireless dual-network. This paper developed a communication module, which has a platform converging and combining the ZigBee of USN environments with the PLC of power line communication environments, to implement a dualized communication interface system supporting the wire-wireless integrated protocol, and implemented a wire-wireless networking device and a control system software technology. As a result, it was automatically switched into the PLC communication within 4.4 seconds on average when there was an access failure in the ZigBee communication network, so a reliable communication network was built.

A spectral efficient transmission method for ofdm-based power line communications (직교주파수분할다중화기반 전력선통신에서 대역 효율적인 전송기법)

  • Kim, Byung Wook
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.4
    • /
    • pp.25-32
    • /
    • 2014
  • Powerline communications (PLC) is a promising medium for network access technology where smart grid aided network services can be provided. In the presence of frequency selective fading in the PLC channel, orthogonal frequency division multiplexing (OFDM) is a technique for reliable communications. This paper presents a spectral efficient method using a superimposed hidden pilot for OFDM-based PLC systems. Based on the scheme using a hidden pilot, it is possible to estimate the channel with no consumption of bandwidth, but with utilization of power allocated to the hidden pilot. Computer simulations showed that the proposed scheme provides higher achievable data rate than that of the conventional schemes in low voltage and medium voltage transmission lines.