• Title/Summary/Keyword: PICN

Search Result 9, Processing Time 0.021 seconds

Novel CAD/CAM hybrid blocks: PICN and RNC (새로운 CAD/CAM 블록의사용 : PICN and RNC)

  • Ko, Kyung-Ho
    • The Journal of the Korean dental association
    • /
    • v.56 no.3
    • /
    • pp.167-174
    • /
    • 2018
  • The development of dental materials has widened the scope of materials by changes in processing methods. CAD/CAM processing enables the use of zirconia as a dental material. Recent esthetic materials development has been made. For aesthetic purposes, a block for CAD/CAM processing by mixing polymer and ceramic materials are fabricated. However there is no guideline of how these materials should be used in actual clinical practice. Mechanical properties, wear and clinical studies were reviewed.

  • PDF

Magnetic and Infrared Spectral Studies of Oxovanadium (IV)-Carboxylate Complexes (옥소바나듐 (IV)-카르복실레이트 착물의 자기적 및 적외적 분광학적 성질)

  • Yoon-Bo Shim;Sung-Nak Choi;Jong-Yul Park
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.76-83
    • /
    • 1986
  • Four oxovandium(IV) complexes with carboxylate ligands, $VO(picn)_2$, $VO(htmq)_2$, $VO(quin)_2$ and $VO(pyra)_2{\cdot}2H_2O)$ have been prepared and studied. Infrared spectral data coupled with the results of magnetic susceptibility study strongly suggest that there are relatively strong intermolecular interactions in $VO(picn)_2$ and $VO(htmq)_2$. In all oxovanadium(IV) complexes studied in this work, the carboxylate ligand coordinates to the metal ion in the unidentated fashion. Some fundamental vibration modes of oxovanadium(IV) complexes were empirically assigned from the difference in the spectrum of metal complex with free ligand.

  • PDF

The effect of thickness and translucency of polymer-infiltrated ceramic-network material on degree of conversion of resin cements

  • Barutcigil, Kubilay;Buyukkaplan, Ulviye Sebnem
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.61-66
    • /
    • 2020
  • PURPOSE. The aim of the present study was to determine the degree of conversion of light- and dual-cured resin cements used in the cementation of all-ceramic restorations under different thicknesses of translucent (T) and high-translucent (HT) polymer-infiltrated ceramic-network (PICN) material. MATERIALS AND METHODS. T and HT PICN blocks were prepared at 0.5, 1.0, 1.5, and 2.0 mm thicknesses (n=80). Resin cement samples were prepared with a diameter of 6 mm and a thickness of 100 ㎛. Light-cured resin cement was polymerized for 30 seconds, and dual-cure resin cement was polymerized for 20 seconds (n=180). Fourier transform infrared spectroscopy (FTIR) was used for degree of conversion measurements. The obtained data were analyzed with ANOVA and Tukey HSD, and independent t-test. RESULTS. As a result of FTIR analysis, the degree of conversion of the light-cured resin cement prepared under 1.5- and 2.0-mm-thick T and HT ceramics was found to be lower than that of the control group. Regarding the degree of conversion of the dual-cured resin cement group, there was no significant difference from the control group. CONCLUSION. Within the limitation of present study, it can be concluded that using of dual cure resin cement can be suggested for cementation of PICN material, especially for thicknesses of 1.5 mm and above.

Magnetic and Spectroscopic Studies of some Oxovanadium(IV) Complexes having O = V(O)$_4$ Chromophore

  • Choi, Sung-Nak;Kim, Young-Inn;Shim, Yoon-Bo;Choo, Hi-Shik;Kim, Young-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.2
    • /
    • pp.138-142
    • /
    • 1989
  • Three oxovanadium(IV) complexes with bidentate ligands having only oxygen donor atoms, benzohydroxamic acid (Hben), 8-hydroxyquinoline-N-oxide(Hhqno) and picolinic acid-N-oxide (Hpicn) are prepared and magnetic and spectroscopic properties are investigated for the complexes $VO(ben)_2,\;VO(hqno)_2\;and \;VO(picn)_2.$ Magnetic data together with IR results strongly indicate that dimeric intermolecular interaction is significant in $VO(ben)_2$ while the presence of polymeric V-O${\cdot}{\cdot}$V-O interaction is suggestive in $VO(picn)_2$. For all three complexes, three electronic d-d transitions were observed; extremely strong optical absorption of these bands of $VO(ben)_2$ in DMSO are supposed to be arised from a great metal-ligand covalency. Some fundamental vibration modes of oxovanadium(IV) complexes were empirically assigned from the differences in the spectrum of metal complexes with free ligand.

Effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material

  • Ozarslan, Mehmet Mustafa;Buyukaplan, Ulviye Sbnem;Barutcigil, Cagtay;Arslan, Merve;Tuker, Nurullah;Barutcigil, Kubilay
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.16-20
    • /
    • 2016
  • PURPOSE. Polymer infiltrated ceramic network (PICN) materials, also called hybrid ceramics, are new materials in dental market. The manufacturer of the PICN material VITA Enamic suggests 3 different finishing procedures for this new material. In the present study, surface roughness and color differences caused from different finishing procedures of VITA Enamic were investigated. MATERIALS AND METHODS. 120 specimens were prepared in dimensions $2{\times}10{\times}12mm$ from VITA Enamic hybrid ceramic blocks with 'high translucency' and 'translucency 2M2' shades. The specimens were divided into 8 groups. For each group, different finishing procedures suggested by the manufacturer were performed. Surface roughness values were determined by a tactile portable profilometer. Color changes were evaluated using a clinical spectrophotometer. The data were analyzed using one-way ANOVA and Tukey's post-hoc comparison. The significance level was set at ${\alpha}=0.05$. RESULTS. The roughest surfaces were observed in Glaze Groups. Their surface roughness values were similar to that of the control group. Clinical Kit and Technical Kit groups did not show a statistically significant difference regarding surface roughness (P>.05). The largest color difference regarding ${\Delta}E_{00}$ was observed in Clinical Kit finishing groups. There were also statistically significant color changes between the groups (P<.05). However, all the groups showed clinically acceptable color change (${\Delta}E_{00}$<2.25) except Clinical Kit Groups (${\Delta}E_{00}$>2.25). CONCLUSION. Within the limitations of the present study, it may be suggested that finishing the VITA Enamic restorations by Technical Kit instead of Glaze and Clinical Kit gives better clinical performance in regard to surface roughness and shade matching.

Effects of staining liquids and finishing methods on translucency of a hybrid ceramic material having two different translucency levels

  • Buyukkaplan, Sebnem Ulviye;Ozarslan, Mehmet Mustafa;Barutcigil, Cagatay;Arslan, Merve;Barutcigil, Kubilay;Yoldan, Elif Ece
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.387-393
    • /
    • 2017
  • PURPOSE. Beverages may affect the translucency of esthetic dental restorative materials.The aim of the present study was to investigate the effects of coffee and red wine on the translucency of a PICN material with two translucency levels, and finished with different methods. MATERIALS AND METHODS. 2M2 high translucent and translucent VITA Enamic hybrid ceramic blocks were investigated. Rectangular specimens with the dimensions of $12mm{\times}14mm{\times}2mm$ were prepared. The specimens were finished and polished with different methods as suggested by the manufacturer. The translucency parameters of the specimens were evaluated before and after 24 hours, 7 days, and 28 days immersion in distilled water, coffee and red wine. Translucency parameters were measured using a portable spectrophotometer. RESULTS. At the end of 28 days, there was no statistically significant difference between the groups of specimens kept in coffee (P>.05). In the red wine groups, there was a statistically significant difference between the control group and all other groups (P<.05) at the end of 28 days. CONCLUSION. The translucency of hybrid ceramic for a restoration may not be important regarding the effects of coffee on translucency change because the specimens with different translucencies and finishing methods that were immersed to coffee had similar translucency parameters at the end of 28 days. The translucency of hybrid ceramic may be important in the case of red wine, however, since the results showed that highly translucent specimens exposed to red wine demonstrated better translucency parameters than specimens made from translucent blocks at the end of 28 days.

Wear evaluation of CAD-CAM dental ceramic materials by chewing simulation

  • Turker, Izim;Kursoglu, Pinar
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.5
    • /
    • pp.281-291
    • /
    • 2021
  • PURPOSE. To evaluate the wear of computer-aided design/computer-aided manufacturing (CAD-CAM) dental ceramic materials opposed by enamel as a function of increased chewing forces. MATERIALS AND METHODS. The enamel cusps of healthy human third molar teeth (n = 40) opposed by materials from CAD-CAM dental ceramic groups (n = 10), including Vita Enamic® (ENA), a polymer-infiltrated ceramic network (PICN); GC Cerasmart® (CERA), a resin nanoceramic; Celtra® Duo (DUO), a zirconia-reinforced lithium silicate (ZLS) ceramic; and IPS e.max ZirCAD (ZIR), a polycrystalline zirconia, were exposed to chewing simulation (1,200,000 cycles; 120 N load; 1 Hz frequency; 0.7 mm lateral and 2 mm vertical motion). The wear of both enamel cusps and materials was quantified using a 3D laser scanner, and the wear mechanisms were evaluated by scanning electron microscopy (SEM). The results were analysed using Welch ANOVA and Kruskal Wallis test (α = .05). RESULTS. ZIR showed lower volume loss (0.02 ± 0.01 mm3) than ENA, CERA and DUO (P = .001, P = .018 and P = .005, respectively). The wear of cusp/DUO [0.59 mm3 (0.50-1.63 mm3)] was higher than cusp/CERA [0.17 mm3 (0.04-0.41 mm3)] (P = .007). ZIR showed completely different wear mechanism in SEM. CONCLUSION. Composite structured materials such as PICN and ZLS ceramic exhibit more abrasive effect on opposing enamel due to their loss against wear, compared to uniform structured zirconia. The resin nano-ceramic causes the lowest enamel wear thanks to its flexible nano-ceramic microstructure. While zirconia appears to be an enamel-friendly material in wear volume loss, it can cause microstructural defects of enamel.

Effect of the type of resin cement on the fracture resistance of chairside CAD-CAM materials after aging

  • Laura Vitoria Rizzatto;Daniel Meneghetti;Marielle Di Domenico;Julia Cadorin Facenda;Katia Raquel Weber;Pedro Henrique Corazza;Marcia Borba
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.3
    • /
    • pp.136-144
    • /
    • 2023
  • PURPOSE. The study objective was to evaluate the influence of the type of resin cement on the flexural strength and load to fracture of two chairside CADCAM materials after aging. MATERIALS AND METHODS. A polymer-infiltrated ceramic network (PICN) and a nanoceramic resin (RNC) were used to produce the specimens. Two types of dual-cure resin cements, a self-adhesive and a universal, were investigated. Bilayer specimens were produced (n = 10) and aged for 6 months in a humid environment before the biaxial flexural strength test (σf). Bonded specimens were subjected to a mechanical aging protocol (50 N, 2 Hz, 37℃ water, 500,000 cycles) before the compressive load test (Lf). σf and Lf data were analyzed using two-way ANOVA and Tukey tests (α = .05). Chi-square test was used to analyze the relationship between failure mode and experimental group (α = .05). RESULTS. The type of resin cement and the interaction between factors had no effect on the σf and Lf of the specimens, while the type of restorative material was significant. RNC had higher σf and Lf than PICN. There was a significant association among the type of cracks identified for specimens tested in Lf and the restorative material. CONCLUSION. The type of resin cement had no effect on the flexural strength and load to fracture of the two investigated CAD-CAM chairside materials after aging.

Effect of surface treatments and universal adhesive application on the microshear bond strength of CAD/CAM materials

  • Sismanoglu, Soner;Gurcan, Aliye Tugce;Yildirim-Bilmez, Zuhal;Turunc-Oguzman, Rana;Gumustas, Burak
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.1
    • /
    • pp.22-32
    • /
    • 2020
  • PURPOSE. The aim of this study was to evaluate the microshear bond strength (µSBS) of four computer-aided design/computer-aided manufacturing (CAD/CAM) blocks repaired with composite resin using three different surface treatment protocols. MATERIALS AND METHODS. Four different CAD/CAM blocks were used in this study: (1) flexible hybrid ceramic (FHC), (2) resin nanoceramic (RNC), (c) polymer infiltrated ceramic network (PICN) and (4) feldspar ceramic (FC). All groups were further divided into four subgroups according to surface treatment: control, hydrofluoric acid etching (HF), air-borne particle abrasion with aluminum oxide (AlO), and tribochemical silica coating (TSC). After surface treatments, silane was applied to half of the specimens. Then, a silane-containing universal adhesive was applied, and specimens were repaired with a composite, Next, µSBS test was performed. Additional specimens were examined with a contact profilometer and scanning electron microscopy. The data were analyzed with ANOVA and Tukey tests. RESULTS. The findings revealed that silane application yielded higher µSBS values (P<.05). All surface treatments were showed a significant increase in µSBS values compared to the control (P<.05). For FHC and RNC, the most influential treatments were AlO and TSC (P<.05). CONCLUSION. Surface treatment is mandatory when the silane is not preferred, but the best bond strength values were obtained with the combination of surface treatment and silane application. HF provides improved bond strength when the ceramic content of material increases, whereas AlO and TSC gives improved bond strength when the composite content of material increases.