PET 장치와 화상 재구성법 (Positron Emission Computed Tomographs and Image Reconstruction Methods)

  • 이만구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권1호
    • /
    • pp.5-11
    • /
    • 1999
  • This paper reviews recent major activities on instrumentation and methodology of PET. The performance of the PET instrumentation can be expressed by four physical characteristics, 1) spatial resolution, 2) coincidence resolving time, 3) energy resolution, and 4) detection efficiency. The physical and technical aspects of PET systems are briefly discussed along with these characteristics. Toward high resolution PET the recent trend has been to design multiple rings of densely packed detector arrays with scintillators. In order to satisfy the sampling requirement in reconstruction, continuous detector units has been developed. Iterative image reconstruction algorithms have received considerable attention for improvement of both the sampling requirement and image quality toward the stationary PET. Better resolving time improves the maximum true coincidence rate, which is also increased with more detectors placed in coincidence with each other. It suggests that volume PET is promising for enhancement of detection efficiency. The scattered coincidence event rate may be reduced by using detectors with better energy resolution. The use of interplane septa, however, takes over improvement of energy resolution in 2D PET. Energy resolution becomes an important factor for image quality under the condition of septa removal such as volume PET. Toward full utilization of emitting photons, 3D reconstruction incorporating oblique rays has been studied, and volume reconstruction algorithms have been developed. Practical volume PET systems impose heavy burden not only to detector sets and coincidence circuits, but also to computers in the memory requirements and the data processing. In conclusion, there have been many ingenious methods in development of PET instrumentation, which are based on unique capability of PET. They will be expected to overcome technical limitations, and to approach the fundamental limits.

  • PDF

Effect of filters and reconstruction method on Cu-64 PET image

  • Lee, Seonhwa;Kim, Jung min;Kim, Jung Young;Kim, Jin Su
    • 대한방사성의약품학회지
    • /
    • 제3권2호
    • /
    • pp.65-71
    • /
    • 2017
  • To assess the effects of filter and reconstruction of Cu-64 PET data on Siemens scanner, the various reconstruction algorithm with various filters were assessed in terms of spatial resolution, non-uniformity (NU), recovery coefficient (RC), and spillover ratio (SOR). Image reconstruction was performed using filtered backprojection (FBP), 2D ordered subset expectation maximization (OSEM), 3D reprojection algorithm (3DRP), and maximum a posteriori algorithms (MAP). For the FBP reconstruction, ramp, butterworth, hamming, hanning, or parzen filters were used. Attenuation or scatter correction were performed to assess the effect of attenuation and scatter correction. Regarding spatial resolution, highest achievable volumetric resolution was $3.08mm^3$ at the center of FOV when MAP (${\beta}=0.1$) reconstruction method was used. SOR was below 4% for FBP when ramp, Hamming, Hanning, or Shepp-logan filter were used. The lowest NU (highest uniform) after attenuation & scatter correction was 5.39% when FBP (parzen filter) was used. Regarding RC, 0.9 < RC < 1.1 was obtained when OSEM (iteration: 10) was used when attenuation and scatter correction were applied. In this study, image quality of Cu-64 on Siemens Inveon PET was investigated. This data will helpful for the quantification of Cu-64 PET data.

PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가 (Evaluation of Standardized Uptake Value applying EQ PET across different PET/CT scanners and reconstruction)

  • 윤석환;김병진;문일상;이홍재
    • 핵의학기술
    • /
    • 제22권1호
    • /
    • pp.35-42
    • /
    • 2018
  • 양전자 방출 단층촬영에서 정량적 평가에 통상적으로 쓰이는 표준섭취계수(SUV : Standardized Uptake Value)는 종양의 병소와 병기의 진단 그리고 치료 성적 평가에 있어서 사용되고 있는 유용한 지표이다. 하지만 SUV는 환자의 체격, 검사까지의 시간, 부분용적 효과, 관심영역의 설정, 검사장비, 영상재구성 차이 등에 따라 변화 되므로 다양한 인자의 영향을 고려하여야만 한다. 그 중에서도 PET/CT 장비와 영상의 재구성 방법의 차이에 의한 SUV의 차이를 SIEMENS 사의 EQ PET을 이용하여 방사능의 차이를 보정 할 수 있게 되었다. 그러므로 본 연구에서는 phantom 실험과 FDG PET 임상영상의 SUVmax를 비교 하여 EQ PET을 적용함으로써, SUV의 변화를 평가 하고 EQ PET의 유용성에 대해서 검증해보고자 하였다. 본원의 3대의 PET/CT 장비인 Biograph true point 40, Biograph mCT 40, Biograph mCT 64 장비를 이용하여 $^{18}F-FDG$를 주입 한 NEMA IEC body phantom 영상을 획득 한 후 OSEM3D+PSF, OSEM3D+TOF, OSEM3D+PSF+TOF의 알고리즘을 이용하여 영상을 재구성 하였다. 각각 재구성된 영상에서 관심영역의 방사능 농도를 측정한 후, EARL에서 권고하는 NEMA IEC body phantom의 방사능 농도의 회복계수 값을 비교하여 서로 다른 PET system 간에 방사능 농도의 차이를 줄일 수 있는 EQ filter 값을 산출 하였다. 산출한 EQ Filter 값을 장비와 영상 재구성에 따라 적용하여 팬텀의 회복계수와 61명의 폐암환자의 FDG PET 영상에서 종양의 SUVmax를 비교 분석 하였다. 3대의 PET/CT 장비에서 영상의 재구성 알고리즘을 달리하여 획득한 phantom의 영상의 6개구의 평균 변동계수는 EQ PET 적용 전 후의 값은 OSEM3D 재구성 영상에서 각각 0.05, 0.04 OSEM3D+TOF 재구성 영상에서는 각각 0.04, 0.03, OSEM3D+PSF 재구성 영상에서는 각각 0.04, 0.03, OSEM3D+PSF+TOF 재구성 영상에서는 각각 0.03, 0.02 값을 보여 EQ PET 적용 후 팬텀의 6개 구의 평균 변동계수는 감소하였다. 임상 영상 비교 에서는 폐암환자 종양의 SUVmax는 OSEM3D, OSEM3D+TOF, OSEM3D+PSF, OSEM3D+PSF+TOF 순으로 증가하였으며, EQ PET 적용 후 재구성 영상에 대한 SUVmax는 통계적으로 유의한 차이가 없었다(p=1.000). PET/CT 영상에서 서로 다른 PET/CT 장비와 영상의 재구성 방법의 차이에 의해 발생하는 방사능 농도의 차이를 EQ PET을 이용하여 측정함으로서 장비와 영상 재구성별 방사능 농도의 편차가 감소되었다. PET 영상에서 정량적 평가에 이용되는 SUV의 편차를 줄일 수 있어 종양의 병소와 병기의 진단, 그리고 치료 성적평가의 정량적 평가 신뢰도가 향상 될 것으로 사료된다.

Breast PET CT 영상 재구성 변화에 따른 대조도 대 잡음비와 신호 대 잡음비의 비교평가 (Evaluation and Comparison of Contrast to Noise Ratio and Signal to Noise Ratio According to Change of Reconstruction on Breast PET/CT)

  • 이재영;이을규;김기원;정회원;유광열;박훈희;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.79-85
    • /
    • 2017
  • 본 연구는 양전자 컴퓨터단층촬영(Positron Emission Computed Tomography; PET-CT) 유방암 영상에서 질환관심영역(Region of Interest; ROI)의 대조도 대 잡음비(Contrast to Noise Ratio; CNR)와 신호 대 잡음비(Signal to Noise Ratio; SNR)를 재구성 기법별로 측정 평가하여 통계적 분석을 하고자 하였다. 연구대상은 서울소재 대학병원에서 유방 양전자 컴퓨터단층촬영(Breast PET-CT)을 검사한 환자 100명이다. 측정방법은 ImageJ 프로그램을 사용하여 표본의 인구사회학적 특성, 영상 재구성 기법별 유방암의 SNR과 CNR의 평균값, 95% 신뢰구간 값, SNR과 CNR의 평균차이 값 등을 분석하였다. SPSS Statistics21 통계프로그램으로 ANOVA 분석을 하였으며 p<0.05에서 유의한 것으로 판단하였다. 영상 재구성 기법별 분석결과는 CNR과 SNR 모두 TrueX_TOF, Iterative, Iterative-TOF, FBP-TOF 순으로 높은 값을 나타냈다(p<0.05). CNR과 SNR수치로 영상 재구성 기법의 특징을 조합하여 PET/CT 검사의 정확성과 편의성을 제공할 것이라 사료된다.

Performance evaluation of an adjustable gantry PET (AGPET) for small animal PET imaging

  • Song, Hankyeol;Kang, In Soo;Kim, Kyu Bom;Park, Chanwoo;Baek, Min Kyu;Lee, Seongyeon;Chung, Yong Hyun
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2646-2651
    • /
    • 2021
  • A rectangular-shaped PET system with an adjustable gantry (AGPET) has been developed for imaging small animals. The AGPET system employs a new depth of interaction (DOI) method using a depth dependent reflector patterns and a new digital time pickoff method based on the pulse reconstruction method. To evaluate the performance of the AGPET, timing resolution, intrinsic spatial resolution and point source images were acquired. The timing resolution and intrinsic spatial resolution were measured using two detector modules and Na-22 gamma source. The PET images were acquired in two field of view (FOV) sizes, 30 mm and 90 mm, to demonstrate the characteristic of the AGPET. As a result of in the experiment results, the timing resolution was 0.9 ns using the pulse reconstruction method based on the bi-exponential model. The intrinsic spatial resolution was an average of 1.7 mm and the spatial resolution of PET images after DOI correction was 2.08 mm and 2.25 mm at the centers of 30 mm and 90 mm FOV, respectively. The results show that the proposed AGPET system provided higher sensitivity and resolution for small animal imaging.

Monotonic and Parallelizable Algorithm for Simultaneous Reconstruction of Activity/Attenuation using Emission data in PET

  • Kim, Seung-Gu
    • Communications for Statistical Applications and Methods
    • /
    • 제8권1호
    • /
    • pp.299-309
    • /
    • 2001
  • In PET(Positron Emission Tomography), it is necessary to use transmission scan data in order to estimate the attenuation map. Recently, there are several empirical studies in which one might be able to estimate attenuation map and activity distribution simultaneously with emissive sinogram alone without transmission scan. However, their algorithms are based on the model in which does not include the background counts term, and so is unrealistic. If the background counts component has been included in the model, their algorithm would introduce non-monotonic reconstruction algorithm which results in vain in practice. in this paper, we develop a monotonic and parallelizable algorithm for simultaneous reconstruction of both characteristics and present the validity through some simulations.

  • PDF

재구성 방법(점 확산함수 적용 유무)에 따른 PET/MR 영상 평가 (Comparison of PET/MR image quality with and without point spread function algorithm according to reconstruction type)

  • 박찬록;문일상;노경운
    • 핵의학기술
    • /
    • 제22권1호
    • /
    • pp.43-45
    • /
    • 2018
  • NEMA IEC body phantom으로 PET/MR 스캐너를 이용해 MR 영상 기반의 감쇠보정 된 PET 영상을 얻고, 반복재구성 기반의 점 확산 함수(PSF)에 적용 유무에 따라 PET 영상을 Contrast recovery 와 SNR 의 평가 인자를 적용해 평가하였다. 또한, 동일한 재구성 방법에 따라 본원의 내원한 환자의 영상도 평가하였다. 데이터는 임상환자 와 팬텀 실험 모두 PSF를 적용해 재구성한 영상이 모두 영상의 질이 향상됨을 확인하였다. MR 기반으로 얻어진 PET 영상 평가가 추후에도 계속해서 필요하다고 사료된다.

Nuclear Medicine Physics: Review of Advanced Technology

  • Oh, Jungsu S.
    • 한국의학물리학회지:의학물리
    • /
    • 제31권3호
    • /
    • pp.81-98
    • /
    • 2020
  • This review aims to provide a brief, comprehensive overview of advanced technologies of nuclear medicine physics, with a focus on recent developments from both hardware and software perspectives. Developments in image acquisition/reconstruction, especially the time-of-flight and point spread function, have potential advantages in the image signal-to-noise ratio and spatial resolution. Modern detector materials and devices (including lutetium oxyorthosilicate, cadmium zinc tellurium, and silicon photomultiplier) as well as modern nuclear medicine imaging systems (including positron emission tomography [PET]/computerized tomography [CT], whole-body PET, PET/magnetic resonance [MR], and digital PET) enable not only high-quality digital image acquisition, but also subsequent image processing, including image reconstruction and post-reconstruction methods. Moreover, theranostics in nuclear medicine extend the usefulness of nuclear medicine physics far more than quantitative image-based diagnosis, playing a key role in personalized/precision medicine by raising the importance of internal radiation dosimetry in nuclear medicine. Now that deep-learning-based image processing can be incorporated in nuclear medicine image acquisition/processing, the aforementioned fields of nuclear medicine physics face the new era of Industry 4.0. Ongoing technological developments in nuclear medicine physics are leading to enhanced image quality and decreased radiation exposure as well as quantitative and personalized healthcare.

저선량에서의 TrueX 재구성 방법에 의한 유용성 평가 (The Evaluation of TrueX Reconstruction Method in Low Dose)

  • 오세문;김계환;김승정;이홍재;김진의
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.83-87
    • /
    • 2011
  • 최근 진단분야에서 PET/CT는 종양학 분야뿐만 아니라 심장 신경 등 여러 가지 분야에서 널리 활용되고 있다. PET/CT의 중요성이 높아지면서 영상의 질과 관련된 재구성 방법에 대한 연구도 활발히 진행되고 있다. 이 중 Siemens사의 TrueX 재구성 방법을 phantom 실험을 통해 Iterative 2D 재구성 방법과 비교 평가하여 임상적 유용성을 높이고자 하였다. 선량에 따른 영상을 비교 평가하기 위해 contrast ratio와 FWHM을 측정하였고 Biograph 40 True Point PET/CT (Siemens, Germany)를 사용하여 실험을 실시하였다. Contrast ratio를 구하기 위해 NEMA IEC PET body phantom (Data Spectrum Corp.)을 이용하였고, FWHM을 측정하기 위해 capillary tube를 사용하였다. 모든 영상은 10분씩 획득하였고, 영상 재구성은 현재 사용하고 있는 TrueX와 기존에 사용하던 Itertive 2D 알고리즘을 사용하였다. Iterative 2D는 임상에 적합한 parameter 조건을 적용하고 TrueX는 Siemens에서 권고하는 parameter를 적용하여 실험하였다. Capillary tube를 사용하여 FWHM을 측정한 결과, TrueX가 Iterative 2D 방식보다 낮게 나왔다. 저선량일수록 FWHM의 차이가 점점 커졌다. NEMA IEC PET body phantom을 사용하여 contrast ratio를 구한 결과, TrueX가 Itertive 2D보다 좋은 양상을 보였다. 그러나 선량에 따른 차이는 보이지 않았다. 본 연구에서는 영상 분석을 통해 TrueX가 Itertive 2D보다 contrast ratio와 spatial resolution이 높게 나타났다. 또한 TrueX를 통한 재구성 결과 저선량일수록 기존의 Iterative 2D보다 resolution은 좋은 양상을 보였고 contrast ratio는 큰 변화를 보이지 않았다. 즉 PET/CT에서 TrueX 재구성 기법이 환자의 피폭도 절감하고 질적으로 우수한 영상을 구현할 수 있어 임상적 이용가치가 높다고 생각된다.

  • PDF

특이값분해 기반 동적의료영상 재구성기법의 특징 파악을 위한 시뮬레이션 연구 (Simulation Study for Feature Identification of Dynamic Medical Image Reconstruction Technique Based on Singular Value Decomposition)

  • 김도휘;정영진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권2호
    • /
    • pp.119-130
    • /
    • 2019
  • Positron emission tomography (PET) is widely used imaging modality for effective and accurate functional testing and medical diagnosis using radioactive isotopes. However, PET has difficulties in acquiring images with high image quality due to constraints such as the amount of radioactive isotopes injected into the patient, the detection time, the characteristics of the detector, and the patient's motion. In order to overcome this problem, we have succeeded to improve the image quality by using the dynamic image reconstruction method based on singular value decomposition. However, there is still some question about the characteristics of the proposed technique. In this study, the characteristics of reconstruction method based on singular value decomposition was estimated over computational simulation. As a result, we confirmed that the singular value decomposition based reconstruction technique distinguishes the images well when the signal - to - noise ratio of the input image is more than 20 decibels and the feature vector angle is more than 60 degrees. In addition, the proposed methode to estimate the characteristics of reconstruction technique can be applied to other spatio-temporal feature based dynamic image reconstruction techniques. The deduced conclusion of this study can be useful guideline to apply medical image into SVD based dynamic image reconstruction technique to improve the accuracy of medical diagnosis.