• Title/Summary/Keyword: PET Scan

Search Result 254, Processing Time 0.038 seconds

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF

Evaluation of Proper Image Acquisition Time by Change of Infusion dose in PET/CT (PET/CT 검사에서 주입선량의 변화에 따른 적정한 영상획득시간의 평가)

  • Kim, Chang Hyeon;Lee, Hyun Kuk;Song, Chi Ok;Lee, Gi Heun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.22-27
    • /
    • 2014
  • Purpose There is the recent PET/CT scan in tendency that use low dose to reduce patient's exposure along with development of equipments. We diminished $^{18}F$-FDG dose of patient to reduce patient's exposure after setting up GE Discovery 690 PET/CT scanner (GE Healthcare, Milwaukee, USA) establishment at this hospital in 2011. Accordingly, We evaluate acquisition time per proper bed by change of infusion dose to maintain quality of image of PET/CT scanner. Materials and Methods We inserted Air, Teflon, hot cylinder in NEMA NU2-1994 phantom and maintained radioactivity concentration based on the ratio 4:1 of hot cylinder and back ground activity and increased hot cylinder's concentration to 3, 4.3, 5.5, 6.7 MBq/kg, after acquisition image as increase acquisition time per bed to 30 seconds, 1 minute, 1 minute 30 seconds, 2 minute, 2 minutes 30 seconds, 3 minutes, 3 minutes 30 seconds, 4 minutes, 4 minutes 30 seconds, 5 minutes, 5 minutes 30 seconds, 10 minutes, 20 minutes, and 30 minutes, ROI was set up on hot cylinder and back radioactivity region. We computated standard deviation of Signal to Noise Ratio (SNR) and BKG (Background), compared with hot cylinder's concentration and change by acquisition time per bed, after measured Standard Uptake Value maximum ($SUV_{max}$). Also, we compared each standard deviation of $SUV_{max}$, SNR, BKG following in change of inspection waiting time (15minutes and 1 hour) by using 4.3 MBq phantom. Results The radioactive concentration per unit mass was increased to 3, 4.3, 5.5, 6.7 MBqs. And when we increased time/bed of each concentration from 1 minute 30 seconds to 30 minutes, we found that the $SUV_{max}$ of hot cylinder acquisition time per bed changed seriously according to each radioactive concentration in up to 18.3 to at least 7.3 from 30 seconds to 2 minutes. On the other side, that displayed changelessly at least 5.6 in up to 8 from 2 minutes 30 seconds to 30 minutes. SNR by radioactive change per unit mass was fixed to up to 0.49 in at least 0.41 in 3 MBqs and accroding as acquisition time per bed increased, rose to up to 0.59, 0.54 in each at least 0.23, 0.39 in 4.3 MBqs and in 5.5 MBqs. It was high to up to 0.59 from 30 seconds in radioactivity concentration 6.7 MBqs, but kept fixed from 0.43 to 0.53. Standard deviation of BKG (Background) was low from 0.38 to 0.06 in 3 MBqs and from 2 minutes 30 seconds after, low from 0.38 to 0 in 4.3 MBqs and 5.5 MBqs from 1 minute 30 seconds after, low from 0.33 to 0.05 in 6.7 MBqs at all section from 30 seconds to 30 minutes. In result that was changed the inspection waiting time to 15 minutes and 1 hour by 4.3 MBq phantoms, $SUV_{max}$ represented each other fixed values from 2 minutes 30 seconds of acquisition time per bed and SNR shown similar values from 1 minute 30 seconds. Conclusion As shown in the above, when we increased radioactive concentration per unit mass by 3, 4.3, 5.5, 6.7 MBqs, the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the same way, in the change of inspection waiting time (15 minutes and 1 hour), we could find that the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the result of this NEMA NU2-1994 phantom experiment, we found that the minimum acquisition time per bed was 2 minutes 30 seconds for evaluating values of fixed $SUV_{max}$ and SNR even in change of inserting radioactive concentration. However, this acquisition time can be different according to features and qualities of equipment.

  • PDF

The Synchronous Occurrence of Splenic Marginal Zone Lymphoma in a Patient with Early Gastric Cancer: A Case Report (조기 위암과 동반된 비장 변연부 림프종 1예)

  • Park, Hyo-Jun;Kim, Keung-Mi;Choi, Min-Gew;Noh, Jae-Hyung;Sohn, Tae-Sung;Bae, Jae-Moon;Kim, Sung
    • Journal of Gastric Cancer
    • /
    • v.9 no.2
    • /
    • pp.63-67
    • /
    • 2009
  • Splenic marginal zone lymphoma (SMZL) is a rare type of non-Hodgkin's lymphoma (NHL). We report here on a patient who displayed the synchronous occurrence of SMZL and early gastric cancer (EGC). The patient was a 74 year-old male with liver cirrhosis. An EGC in the gastric antrum was diagnosed and the preoperative abdomen computed tomography scan revealed splenomegaly and intra-abdominal lymphadenopathy. We performed subtotal gastrectomy and the postoperative pathologic examination revealed adenocarcinoma limited to the gastric mucosa and SMZL in the lymph nodes. The patient recovered from the surgery without complications and is now awaiting chemotherapy. SMZL has an indolent clinical course with good long-term survival and so there is the possibility of the occurrence of a second primary malignancy. Rare cases of a second primary malignancy being diagnosed along with SMZL have been described in the literature. Patients with SMZL should be carefully followed after treatment to detect the possible occurance of a second primary malignancy.

  • PDF

Burnt-out Metastatic Prostate Cancer

  • Shin, Dong Suk;Koo, Dong Hoe;Yoo, Suhyeon;Ju, Deok Yun;Jang, Cheol Min;Joo, Kwan Joong;Shin, Hyun Chul;Chae, Seoung Wan
    • Journal of Yeungnam Medical Science
    • /
    • v.30 no.2
    • /
    • pp.116-119
    • /
    • 2013
  • A burnt-out prostate cancer tumor is a very rare clinical entity. The term 'burnt-out' refers to a primary tumor that has spontaneously and nearly completely regressed without treatment. Since metastasis of prostate cancer is usually encountered in the presence of advanced disease, distant metastasis with an undetectable primary tumor is very rare. We report herein a case of a burnt-out prostate cancer tumor that metastasized to the thoracic (T) spine and caused cord compression. A 66-year-old man visited the Emergency Department due to weakness of both legs for the past two days. His blood and urine tests were normal at the time. His spine magnetic resonance imaging (MRI) scans looked like bone metastasis that involved the T-7 vertebral body and a posterior element, and caused spinal cord compression. Other images, including from the brain MRI, neck/chest/abdomino-pelvic computed tomography (CT) scan and 18F-fluorodeoxyglucose (FDG)-positron emission tomography (PET) and endoscopy, revealed no lesions that suggested malignancy. After total corpectomy T-7 and screw fixation/fusion at T5 to T10, the pathology report revealed a metastatic carcinoma that was strongly positive for prostate-specific antigen (PSA). The serum PSA value was 1.5 ng/mL. The transrectal 12-core prostate biopsy and ultrasonography showed no definitive hypoechoic lesion, but one specimen had slight (only 1%) adenocarcinoma with a Gleason score of 6 (3+3). The final diagnosis was burned-out prostate cancer with an initial normal PSA value. Although metastatic disease with an unknown primary origin was confirmed, a more aggressive approach in seeking the primary origin could provide a more specific treatment strategy and greater clinical benefit to patients.

Improvement of Endoscopic Image using De-Interlacing Technique (De-Interlace 기법을 이용한 내시경 영상의 화질 개선)

  • 신동익;조민수;허수진
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.469-476
    • /
    • 1998
  • In the case of acquisition and displaying medical Images such as ultrasonography and endoscopy on VGA monitor of PC system, image degradation of tear-drop appears through scan conversion. In this study, we compare several methods which can solve this degradation and implement the hardware system that resolves this problem in real-time with PC. It is possible to represent high quality image display and real-time processing and acquisition with specific de-interlacing device and PCI bridge on our hardware system. Image quality is improved remarkably on our hardware system. It is implemented as PC-based system, so acquiring, saving images and describing text comment on those images and PACS networking can be easily implemented.metabolism. All images were spatially normalized to MNI standard PET template and smoothed with 16mm FWHM Gaussian kernel using SPM96. Mean count in cerebral region was normalized. The VOls for 34 cerebral regions were previously defined on the standard template and 17 different counts of mirrored regions to hemispheric midline were extracted from spatially normalized images. A three-layer feed-forward error back-propagation neural network classifier with 7 input nodes and 3 output nodes was used. The network was trained to interpret metabolic patterns and produce identical diagnoses with those of expert viewers. The performance of the neural network was optimized by testing with 5~40 nodes in hidden layer. Randomly selected 40 images from each group were used to train the network and the remainders were used to test the learned network. The optimized neural network gave a maximum agreement rate of 80.3% with expert viewers. It used 20 hidden nodes and was trained for 1508 epochs. Also, neural network gave agreement rates of 75~80% with 10 or 30 nodes in hidden layer. We conclude that artificial neural network performed as well as human experts and could be potentially useful as clinical decision support tool for the localization of epileptogenic zones.

  • PDF

Evaluation of the Effect of Metal Artifacts Varying the Parameters of the Attenuation Map for the artificial Hip Joint in SPECT/CT (SPECT/CT에서 인공고관절에 대한 감쇠보정지도(Attenuation Map)의 매개변수 변화에 따른 금속 인공물(Metal Artifact)의 영향 평가)

  • Kim, Sang Gyu;Kim, Jung Yul;Park, Min Soo;Jo, Seung Hyun;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.3-7
    • /
    • 2014
  • Purpose SPECT/CT scan to be performed attenuation correction on the basis of CT induce an overestimation of the site due to the beam hardening artifact by metal cover and reduce the images quality. Therefore, this study using a phantom that has been inserted artificial hip joint investigated that effect on the SPECT/CT image causing by metal artifact for varying the parameters of the Attenuation Map. Materials and Methods Siemens Symbia T16 SPECT/CT equipment was used. Artificial hip joint was inserted to SPECT/PET phantom, 17 mm sphere of Bright Streak area in CT image was filled with Tc-99m so that the radiation activity was 8 times compared to background. And then Hot and Background was measured in varying Wide Beam Coefficient on Attenuation Map and RBR (Region to Background Ratio) of Metal and Non-Metal was calculated and analyzed depending on the presence or absence of the hip joint. Results It tended to hot count of Non-Metal and Metal to increase as the value of the manual mode is increased, hot count ratio with the group of both manual mode 0.5 and 0.4 is the best match. Also, in automatic mode, the ratio of RBRNon-Metal and RBRMetal was 1.135, statistically significant difference was not observed in the manual mode 0.5 and 0.4. Conclusion In the automatic mode of Wide Beam Coefficient in attenuation correction map, it was found that it is over-correction by 13.52%, it was possible to minimize the over-correction by the artifact in 0.5 and 0.4 of manual mode. Further studies should be performed in order to apply to a patient with the help of this and it is considered possible to reduce the over-correction by the metal artifact of an artificial hip joint for Hip-Resurfacing Arthroplasty patients, and to improve the diagnostic performance.

  • PDF

Locally Advanced, Unresectable Pancreatic Cancer Treated by Stereotactic Radiation Therapy (국소적으로 진행된, 절제 불가능한 췌장암에서 정위 방사선 치료)

  • Choi Chul-Won;Kim Mi-Sook;Cho Chul-Koo;Yoo Seong-Yul;Yang Kwang-Mo;Yoo Hyung-Jun;Lee Dong-Han;Ji Young-Hoon;Han Chul-Ju;Kim Jin;Kim Young-Han
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.11-20
    • /
    • 2006
  • Puroose: In order to find out whether stereotactic radiation therapy (RT) using CyberKnife (CK) could improve survival rate and lower acute toxicity compared to conventional RT. Materials and Methods: From April 2003 through April 2004, 19 patients with Eastern Cooperative Oncology Group (ECOG) performance status ${\leq}3$ and locally advanced pancreas cancer without distant metastasis, evaluated by CT or PET/CT, were included. We administered stereotactic RT consisting of either 33 Gy, 36 Gy or 39 Gy in 3 fractions to 6, 4 and 9 patients, respectively, in an effort to increase the radiation dose step by step, and analyzed the survival rate and gastrointestinal toxicities by the acute radiation morbidity criteria of Radiation Therapeutic Oncology Group (RTOG). Prognostic factors of age, sex, ECOG performance score, chemotherapy, bypass surgery, radiation dose, CA 19-9, planning target volume (PTV), and adjacent organ and vessel invasion on CT scan were evaluated by Log Rank test. Results: The median survival time was 11 months with 1-year survival rate of 36.8%. During follow-up period (range $3{\sim}20$ months, median 10 months), no significant gastrointestinal acute toxicity (RTOG grade 3) was observed. In univariate analysis, age, sex, ECOG performance score, chemotherapy, bypass surgery, radiation dose, CA 19-9 level, and adjacent organ and vessel invasion did not show any significant changes of survival rate, however, patients with PTV (80 cc showed more favorable survival rate than those with PTV>80 cc (p-value<0.05). In multivariate analysis, age younger than 65 years and PTV>80 cc showed better survival rate. Conclusion: In terms of survival, the efficacy of stereotactic radiation therapy using CK was found to be superior or similar to other recent studies achieved with conventional RT with intensive chemotherapy, high dose conformal RT, intraoperative RT (IORT), or intensity modulated RT (IMRT). Furthermore, severe toxicity was not observed. Short treatment time in relation to the short life expectancy gave patients more convenience and, finally, quality of life would be increased. Consequently, this could be regarded as an effective novel treatment modality for locally advanced, unresectable pancreas cancer. PTV would be a helpful prognostic factor for CK.

A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Kim, Bit-Na;Cho, Suk Won;Lee, Juyoung;Lyu, Kwang Yeul;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to 99mTc emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radio technologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radio technologists. Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8cm$, mean weight: $65.9{\pm}1.4kg$). Radiation was measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150, and 200 cm, respectively. Then, all the procedure was given with a portable radiation shielding on the location of head, chest, and abdomen at the distance of 100, 150, and 200 cm and transmittance was calculated. In 10 cm, head ($105.40{\mu}Sv/h$) was the highest and foot($15.85{\mu}Sv/h$) was the lowest. In 200 cm, head, chest, and abdomen showed similar. On head, the measured dose rates were $9.56{\mu}Sv/h$, $5.23{\mu}Sv/h$, and $3.40{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, and $1.27{\mu}Sv/h$ in 100, 150, and 200 cm on head. On chest, the measured dose rates were $8.54{\mu}Sv/h$, $4.90{\mu}Sv/h$, $3.44{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, and $1.13{\mu}Sv/h$ in 100, 150, and 200 cm on chest. On abdomen, the measured dose rates were $9.83{\mu}Sv/h$, $5.15{\mu}Sv/h$, and $3.18{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, and $1.23{\mu}Sv/h$ in 100, 150, and 200 cm on abdomen. Transmittance was increased as the distance was expanded. As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the technologists.

Thallium-201 SPECT in the Evaluation of Postoperative Tumor Recurrence on the Chest Wall in Lung Cancer (폐암 수술 후 흉벽의 종양 재발 검출에 있어 Tl-201 폐 SPECT의 유용성)

  • Ryu, Young-Hoon;Kim, Hyung-Jung;Ahn, Chul-Min;Kim, Se-Kyu;Paik, Hyo-Chae;Lee, Doo-Yun;Chung, Kyung-Young;Yune, Min-Jin;Park, Sang-Jung;Moon, Sung-Wook;Kim, Sang-Jin;Lee, Jong-Doo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.5
    • /
    • pp.542-549
    • /
    • 2002
  • Purpose : The purpose of our study was to assess the usefulness of the Tl-201 SPECT for the detection of the postoperative tumor recurrence on chest wall. Methods: 28 patients including 14 with suspected recurrence of tumor in the chest wall on postoperative chest cr scan, 10 with postoperative pleural effusion which proved benign on radiologic, cytologic and laboratory findings, and 4 with chronic tuberculous empyema as control group were included. All patients underwent SPECT 30 minutes and 4 hours after intravenous injection of 111MBq of Tl-201. Tumor uptake was visually graded by two interpreters and scored as follows : no uptake:0, similar to contralateral lung: 1, higher than contralateral lung but less than heart:2 and similar to heart:3. Results : Markedly increased (grade 3 or 2) Tl-201 uptake was noted in patients with suspected recurrence of tumor in the chest wall (13/14) whereas no (8/10) or minimal (2/10) uptake along the collapsed lung in patients with postoperative benign pleural effusion. In two patients, Tl-201 SPECT revealed additional recurrent tumor mass lesions that were barely perceptible on chest cr scan. Patients with chronic tuberculous empyema showed relatively smoothly marginated increased uptake along the chest wall 4/4), but lesser in degree (grade 1 or 2), when compared to recurrent tumor uptake. Conclusion : Tl-201 lung SPECT seems to be useful to detect postoperative tumor recurrence on chest wall and to differentiate malignant from benign pleural effusion and may provide additional information to the morphologic data obtained by CT.

Development and Assessment Individual Maximum Permissible Dose Method of I-131 Therapy in High Risk Patients with Differentiated Papillary Thyroid Cancer (물리학 선량법을 이용한 갑상선암의 개인별 최대안전용량 I-131 치료법 개발과 유용성 평가)

  • Kim, Jeong-Chul;Yoon, Jung-Han;Bom, Hee-Seung;JaeGal, Young-Jong;Song, Ho-Chun;Min, Jung-Joon;Jeong, Heong;Kim, Seong-Min;Heo, Young-Jun;Li, Ming-Hao;Park, Young-Kyu;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.110-119
    • /
    • 2003
  • Purpose: Radioiodine (I-131) therapy is an effective modality to reduce both recurrence and mortality rates in differentiated thyroid cancer. Whether higher doses shows higher therapeutic responses was still debatable. The purpose of this study was to validate curve-fitting (CF) method measuring maximum permissible dose (MPD) by a biological dosimetry using metaphase analysis of peripheral blood lymphocytes. Materials and Methods: Therapeutic effects of MPD was evaluated in 58 patients (49 females and 9 males, mean age $50{\pm}11$ years) of papillary thyroid cancer. Among them 43 patients were treated with ${\Leq}7.4GBq$, while 15 patients with ${\geq}9.25GBq$. The former was defined as low-dose group, and the latter high-dose group. Therapeutic response was defined as complete response when complete disappearance of lesions on follow-up I-131 scan and undetectable serum thyroglobulin levels were found. Statistical comparison between groups were done using chi-square test. P value less than 0.05 was regarded as statistically significant. Results: MPD measured by CF method using tracer and therapeutic doses were $13.3{\pm}1.9\;and\;13.8{\pm}2.1GBq$, respectively (p=0.20). They showed a significant correlation (r=0.8, p<0.0001). Exposed doses to blood measured by CF and biological methods were $1.54{\pm}0.03\;and\;1.78{\pm}0.03Gy$ (p=0.01). They also showed a significant correlation (r=0.86, p=0.01). High-dose group showed a significantly higher rate of complete response (12/15, 80%) as compared to the low-dose group (22/43, 51.2%) (p=0.05). While occurrence of side effects was not different between two groups (40% vs. 30.2%, p=0.46). Conclusion: Measurement of MPD using CF method is reliable, and the high-dose I-131 therapy using MPD gains significantly higher therapeutic effects as compared with low-dose therapy.