• Title/Summary/Keyword: PET Scan

Search Result 253, Processing Time 0.033 seconds

Optimal Scan time Analysis for Pancreatic Cancer Distinction in Dual time PET-CT Exam (이중시간 PET/CT 검사에서 췌장암 판별을 위한 최적의 Scan time 분석)

  • Chang, Boseok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.305-311
    • /
    • 2019
  • In this study, present the most useful delay scan time by statistical analysis of SUVm data for 30 suspected pancreatic cancer patients. Two statistical analysis and a mathematical model was applied to the theoretical formula by glucose and insulin mechanics, and a mathematical model was created. Statistical analysis was performed via Metlab p/g. Optimal delay scan time was suggested by Metlab p/g for the change of SUV value over time.In this study, for diagnosis pancreatic cancer by dual time point PET/CT, propose optimal delay scan time 131.5 minuts. The proposed delay scan time showed statistical reliability applicable to the diagnosis of pancreatic cancer (p<0.05). Delayed scanning with the suggested delay scan time of 131.5 minutes is considered to be useful for the diagnosis of pancreatic cancer compared to general PET / CT scan.hen the delayed test is performed with the proposed delay scan time 131.5 minuts, Compared with general PET/CT scans.

Usefulness of Scan Position Change on Dual Time Point PET-CT in Pancreas Cancer (췌장암 Dual Time Point PET/CT 검사에서 Scan Position Change의 유용성 평가)

  • Chang, Boseok;Kim, Jae Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.299-305
    • /
    • 2016
  • Despite of the development of medical equipments and technology. Pancreatic cancer has maked high false positive rate and low survival rate compared to other cancers. Therefore, early catch of pancreatic cancer is the only way to enhance the viability. It is important to find the exact location of the pancreas cancer in early stage. The method of optimum scan for early detection of pancreatic cancer on PET/CT exam is proposed. Examined the anatomical region that potentially can be missing from the supine position of ordinary pet/ct exam. The characteristics and usefulness of angle variation ($0^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, $90^{\circ}$) of patients scan position is analyzed. The proposed scan method (named JJ-projection) is bringing advantage of anatomical discrimination by separating stomach, liver, gallbladder duodenum and pancreas. ROC curve analysis is shows to advantage of the JJ-Projection method. The sensitivity has increased 4.6% than the supine delay scan method, the results sensitivity has increased from 91% to 95.2%. The specificity has increased from 75.1% to 84%. Compared with the results observed in cancer by biological biopsy, The accuracy has increased from 86.8% to 94.1%.

The Role of PET in Thyroid Cancer (갑상선암에서 PET의 역할)

  • Yeo, Jeong-Seok
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.3
    • /
    • pp.147-154
    • /
    • 2002
  • The role of PET in the diagnosis and management of thyroid cancer is discussed. The major role of F-18 FDG PET is on patients with discordant negative I-131 scan and a positive serum thyroglobulin values. F-18 FDG PET scan localized metastatic sites in I-131 scan-negative thyroid carcinoma patients with high accuracy. F-18 PET is also valuable in medullary thyroid cancer with high calcitonin level. Focal thyroid uptake in patients with non-thyroidal diseas has high likelihood of thyroid cancer.

$^{18}F-FDG-PET/CT$ in Prostate Cancer (전립선암에서 $^{18}F-FDG-PET/CT$)

  • Jeon, Tae-Joo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.116-120
    • /
    • 2008
  • Prostate cancer is the second leading cause of cancer death of men in western countries and the death related to this disease in Korea is also getting increased. Although anatomic imaging tools such as transrectal US or MRI have been playing a great role in detection of primary prostate lesion, the evaluation of regional lymph node or distant organ metastasis using these modalities is not successful. $^{18}F-FDG-PET$ scan is emerging diagnostic tool for various malignancies. Considering the usual characteristics of prostate cancer such as slow growing and osteoblastic metastasis, the application of FDG PET scan to this disease might be limited. However, in advanced prostate cancer refractory to chemotherapy, FDG PET scan show strong FDG uptake and SUV changes in serial PET scan can be a good indicator of treatment response. Although FDG PET can be useful only in limited cases of prostate cancer, its indication can be widened in future owing to rapid technical improvement and accumulated experiences in this field.

Evaluation about a Usefulness of ECG-Gated Scan on 13N-ammonia PET (13N-ammonia 심장 PET 검사에서 ECG gated scan의 유용성 평가)

  • Kim, Jae-Il;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.20-23
    • /
    • 2016
  • Purpose Because of heart movement, PET image of heart is very blur. So, PET scan gated with ECG is necessary to improve a spatial resolution of heart PET image. In this study, we will evaluate a image quality of both gated $^{13}N-ammonia$ PET scan and non-gated one. Materials and Methods Before start a heart PET, we attached a ECG electrode on patients (n = 5, $aged=54{\pm}17$). And we started a list mode PET scan that used by a mCT40 PET/CT (siemens, germany) during 10 minute, injected $^{13}N-ammonia$ ($378{\pm}50MBq$) to a patients at same time. By using this list mode data, we reconstructed both gated PET image and non-gated PET image. Then we analysed a profiles of those images, performed a blind test, and subtracted a gated image on non-gated image. Results FWHM of a gated image is improved about 23% and there is a differency count distribution at a subtracted image from non-gated image to a gated image. But in case of blind test, everybody select the gated image as a better quality among each images. Conclusion As a result, we can find that image quality will improve by using gated PET scan. In additional, we can calculate a EF valve, apply QGS, QPS of PET. Therefore, the gated PET scan help improving an accuracy, applying a more information for a diagnosis.

  • PDF

Effective Dose Evaluation using Clinical PET/CT Acquisition Protocols (전신 PET/CT 영상 획득 프로토콜을 이용한 유효선량 평가)

  • Nam, So-Ra;Son, Hye-Kyung;Lee, Sang-Hoon;Lee, Chang-Lae;Cho, Hyo-Min;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.173-178
    • /
    • 2006
  • The purpose of this study was to evaluate the radiation dose for clinical PET/CT protocols in clinical environments using Alderson phantom and TLDs. Radiation doses were evaluated for both Philips GEMINI 16 slice PET/CT system and GE DSTe 16 slice PET/CT system. Specific organ doses with $^{137}Cs$ transmission scan, high quality CT scan and topogram in philips GEMINI PET/CT system were measured. Specific organ doses with CT scan for attenuation map, CT scan for diagnosis and topogram in GE DSTe PET/CT system were also measured. The organs were selected based on ICRP60 recommendation. The TLDs used for measurements were selected for within an accuracy of ${\pm}5%$ and calibrated in 10 MV X-ray radiation field. The effective doses for $^{137}Cs$ transmission scan, high qualify scan, and topogram in Philips GEMINI PET/CT system were $0.14{\pm}0.950,\;29.49{\pm}1.508\;and\;0.72{\pm}0.032mSv$ respectively. The effective doses for CT scan to make attenuation map, CT scan to diagnose and topogram in GE DSTe PET/CT system were $20.06{\pm}1.003,\;24.83{\pm}0.805\;and\;0.27{\pm}0.008mSv$ respectively. We evaluated the total effective dose by adding effective dose for PET Image. The total PET/CT doses for Philips GEMINI PET/CT (Topogram+$^{137}Cs$ transmission scan+PET, Topogram+high qualify CT+PET) and GE DSTe PET/CT (Topogram +CT for attenuation map+ PET, Topogram+diagnostic CT+ PET) are $7.65{\pm}0.951,\;37.00{\pm}1.508,\;27.12{\pm}1.003\;and\;31.89{\pm}0.805mSv$ respectively. Further study may be needed to be peformed to find optimal PET/CT acquisition protocols for reducing the patient exposure with good image qualify.

  • PDF

FDG-PET and MDP scan findings in chronic osteomyelitis of the left femur (좌측 대퇴골에 발생한 만성골수염의 PET와 MDP scan 영상)

  • Park, Chan-H.;Lee, Myoung-Hoon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.2
    • /
    • pp.143-145
    • /
    • 2002
  • A 49-year-old male patient with a carcinoma of the right pyriform sinus had a whole-body bone scan and gamma camera based F-18 FDG-PET for staging. Tc-99m MDP bone scan depicted diffuse increased uptake in the left femur due to chronic osteomyelitis but no skeletal metastasis. F-18-FDG-PET revealed increased focal bone uptake and uptake in the draining sinus due to chronic osteomyelitis in addition to visualization of the right pyriform sinus carcinoma and right neck nodal uptake. Fluorine-18 fluorodeoxyglucose-positron emission tomography is significantly more accurate than the bone scan in pinpointing chronic osteomyelitis focus and draining soft tissue infection.

Value of Bone Scan in Addition to F-18 FDG PET/CT and Characteristics of Discordant lesions between F-18 FDG PET/CT and Bone Scan in the Spinal Bony Metastasis (척추골전이에 있어 F-18 FDG PET/CT에 대한 골스캔의 추가적 역할 및 F-18 FDG PET/CT와 골스캔간에 불일치 병소에 대한 연구)

  • Jun, Sung-Min;Nam, Hyun-Yeol;Kim, In-Ju;Kim, Yong-Ki;Kim, Ju-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.218-228
    • /
    • 2008
  • Purpose: Our purpose was to evaluate spinal bony metastasis which could be missed on an F-18 FDG PET/CT (FDG PET/CT) alone, and to characterize discordant metastatic lesions between FDG PET/CT and bone scan. Material and Methods: FDG PET/CT and bone scans of 43 patients with spinal bony metastasis were analyzed retrospectively. A McNemar test was performed comparing the FDG PET/CT alone to the FDG PET/CT plus bone scan in the spinal bony metastases. A one-way chi-square test was performed to characterize the metastases that were missed on the FDG PET/CT alone. To evaluate discordant lesions between FDG PET/CT and bone scan, we performed logistic regression analyses. The independent variables were sites (cervical, thoracic, and lumbar), size (large and small), and maximum SUVs, and the dependant variable was bone scan uptake (positive and negative MDP uptake). Results: A significant difference was found between the FDG PET/CT alone and the FDG PET/CT combined with the bone scan (p < 0.01). Using the FDG PET/CT only, diffuse osteoblastic metastasis was missed with a significantly higher frequency (p = 0.04). In the univariate analysis, cervical vertebra and small size were related to negative MDP uptake, and thoracic vertebra and large size were related to positive MDP uptake. However, in the multivariate analysis, only the large size was related to positive MDP uptake. Conclusion: A bone scan in addition to the FDG PET/CT increased the ability to evaluate spinal bony metastases, especially for diffuse osteoblastic metastasis. Large metastasis was related to positive bone scan uptake in spinal bony metastasis.

Gamma Ray Detection Processing in PET/CT scanner (PET/CT 장치의 감마선 검출과정)

  • Park, Soung-Ock;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.125-132
    • /
    • 2006
  • The PET/CT scanner is an evolution in image technology. The two modalities are complementary with CT and PET images. The PET scan images are well known as low resolution anatomic landmak, but such problems may help with interpretation detailed anatomic framework such as that provided by CT scan. PET/CT offers some advantages-improved lesion localization and identification, more accurate tumor staging. etc. Conventional PET employs tranmission scan require around 4 min./bed position and 30 min. for whole body scan. But PET/CT scanner can reduced by 50% in whole body scan. Especially nowadays PET scanner LSO scintillator-based from BGO without septa and operate in 3-D acquisition mode with multidetectors CT. PET/CT scanner fusion problems solved through hardware rather than software. Such device provides with the capability to acquire accurately aligned anatomic and functional images from single scan. It is very important to effective detection from gamma ray source in PETdetector. And can be offer high quality diagnostic images. So we have study about detection processing of PET detector and high quality imaging process.

  • PDF

$^{18}$F-Fluoride-PET in Skeletal Imaging ($^{18}$F-Fluoride-PET을 이용한 골격계 영상)

  • Jeon, Tae-Joo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.253-258
    • /
    • 2009
  • Bone scintigraphy using $^{99m}$Tc-labeled phosphate agents has long been the standard evaluation method for whole skeletal system. However, recent shortage of $^{99m}$Tc supply and advanced positron emission tomography (PET) technology evoked the attention to surrogate radiopharmaceuticals and imaging modalities for bone. Actually, fluorine-18 ($^{18}$F) was the first bone seeking radiotracer before the introduction of $^{99m}$Tc-labeled agents even though its clinical application failed to become pervasive anymore after the rapid spread of Anger type gamma camera systems in early 1970s. However, rapidly developed PET technology made us refocus on the usefulness of $^{18}$F as a PET tracer. Early study comparing $^{18}$F-Na PET scan and planar bone scintigraphy reported that PET has higher sensitivity and specificity in the diagnosis of metastatic bone lesions than planar bone scan. Subsequent reports comparing between PET and both planar and SPECT bone image also revealed better results of PET scan in similar study groups. Rapid clinical application of PET/CT also accumulated considerable amount of experiences in skeletal evaluation and this modality is known to have better diagnostic power than stand alone PET system as well as bone scan. Furthermore $^{18}$F-Na PET/CT revealed better or at least equal results in detection of primary and metastatic bone lesions compared with CT and MRI. Therefore, it is obvious that $^{18}$F-Na PET/CT has potential to become new imaging modality for practical skeletal evaluation so continuous and careful evaluation of this modality and radiopharmaceutical must be required.