• Title/Summary/Keyword: PDP TVs

Search Result 117, Processing Time 0.031 seconds

Operating Characteristics of LLC Series Resonant Converter (LLC 직렬공진 컨버터 동작특성)

  • Kang, Sung-In;Yoon, Kwang-Ho;Park, Jun-Ho;Huh, Dong-Young;Kim, Eun-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.472-482
    • /
    • 2007
  • The LLC series resonant converter with a LLT (Inductor-Inductor-Transformer) transformer design process and experimentation results for PDP TV power supply is presented. LLT transformer used to combine the inductor and transformer into one unit has the increased leakage inductance in the primary and secondary due to the winding method and the use of the gaped core. The increased leakage inductance in the primary and secondary of LLT transformer can be impacted on the DC voltage gain characteristics of LLC series resonant converter, In this paper, DC gain characteristics and the experimental results of the LLC series resonant converter with a LLT transformer are verified on the Math-CAD simulation based on the theoretical analysis and the 600W experimental prototype.

LLC Series Resonant Converter with two Transformers (두 대의 LLT 변압기 적용 LLC 직렬 공진 컨버터)

  • Kang, Sung-In;Kim, Joo-Hoon;Kim, Eun-Soo;Park, Jun-Ho;Huh, Dong-Young;Jung, Yong-Chae
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.431-439
    • /
    • 2009
  • In this paper, design procedures and voltage gain characteristics on LLC resonant converter with two transformers are described. Two transformers applied to LLC resonant converter are connected in series at the primary and connected in parallel at the secondary to reduce the unbalance of the primary current. Based on the theoretical analysis and simulation results, considering the characteristics of voltage gain and load variation, prototype of the 400W LLC resonant converter for 50inch PDP TV power module is built and the design procedures through the experimental results are verified.

A Novel Flyback Converter for Low Standby Power Consumption (대기전력저감을 위한 플라이백컨버터)

  • Chung, Bong-Gun;Jang, Sang-Ho;Kim, Eun-Soo;Choi, Mun-Gi;Kye, Moon-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.299-306
    • /
    • 2009
  • Recently, although the power consumption of the flyback converter at the light load and standby power load was minimized by the burst mode operation of PWM IC, flyback converter has still the low efficiency characteristics by the high magnetizing current flowing through magnetizing inductance of transformer. This paper proposes a novel flyback converter with an improved efficiency characteristics and the reduced magnetizing current at the light load and standby power load. Prototype of the 70W multi-output flyback converter for an auxiliary power module of 50 inch PDP TV is built and the experimental results are described.

High Luminance $Zn_2SiO_4:Mn$ Phosphors Prepared by Homogeneous Precipitation Method

  • Sohn, Kee-Sun;Choi, Yoon-Young;Jung, Ha-Kyun;Park, Hee-Dong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.31-32
    • /
    • 2000
  • $Zn_2SiO_4:Mn$ phosphors have been recently spotlighted as a green component for plasma TV application. Commercial phosphors such as P1 and P39 have been known to be a very efficient green light emitter for lamp and CRT application. Unfortunately, such commercial phosphors are not suitable for the plasma TV application as both the emission intensity and the decay time do not meet the requirement for plasma TV. The present investigation aims at improving the existing $Zn_2SiO_4:Mn$ phosphors for the purpose of adapting them to PDP application.

  • PDF

An Experimental Study on the noise Rating of H.D. TV sets by Psycho-acoustic Experiments (청감실험을 통한 고화질 TV set 소음평가에 관한 실험적 연구)

  • Lee, Ju-Yeob;Park, Hyeon-Ku;Lee, Tai-Gang;Kim, Hye-Jin;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.862-869
    • /
    • 2006
  • The purpose of this study is to propose the proper vocabularies for evaluating H.D TV set fan noise in residential condition. To achieve this goal, psycho-acoustic experiments were carried out with TV set fan noise modulated at specific frequency band. finally, a correlation analysis between vocabularies, and a factor analysis of psycho-acoustical responses were conducted. As a result of this study, followings are suggested. Analyzing the psycho-acoustical response corresponding to the various sound level, the higher the sound levels, the higher the response values were. It is estimated that the sound level determined psycho-acoustical responses. On the degree of response to fan noise, the initial level of negative feeling is located on $35{\sim}40$ dB(A). The factor of evaluating H.D. TV set fan noise has induced three the appropriate korean adjectives; Irritate, Monotonous, stuffy and dryness. The result of this study may be used to evaluate the acoustic threshold level for indoor noise or a basis for specifying the desired acoustic environment of dwellings.

  • PDF

An Experimental Study on the Noise Evaluation of H.D. TV sets by Psycho-acoustic Experiments (청감실험을 통한 고화질 TV set 소음평가에 관한 실험적 연구)

  • Lee, Ju-Yeob;Lee, Tai-Gang;Kim, Hye-Jin;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.10 s.115
    • /
    • pp.1014-1023
    • /
    • 2006
  • The purpose of this study is to propose the proper vocabularies for evaluating H.D TV set fan noise. To achieve this goal, psycho-acoustic experiments were carried out with TV set fan noise modulated at specific frequency band. Finally, a correlation analysis between vocabularies, and a factor analysis of psycho-acoustical responses were conducted. As a result of this study, followings are suggested. Analyzing the psycho-acoustical response corresponding to the various sound level, the higher the sound levels, the higher the response values were. It is estimated that the sound level determined psycho-acoustical responses. On the degree of response to fan noise, the initial level of negative feeling is located on $35{\sim}40$ dB(A). The factor of evaluating H.D. TV set fan noise has induced three the appropriate korean adjectives; Irritate, Monotonous, stuffy and dryness. The result of this study may be used to evaluate the acoustic threshold level for indoor noise or a basis for specifying the desired acoustic environment of dwellings.

Image Enhancement Using Error Diffusion with APL in PDP (APL 적용 오차 확산법을 이용한 PDP 화질 개선)

  • Jang Soo-Wook;Pyo Se-Jin;Lee Sung-Hak;Sohng Kyu-Ik;Kim Eun-Su
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.10
    • /
    • pp.1360-1368
    • /
    • 2005
  • PDP is the flat panel display, suitable for high definition television because of large-sire and high-brightness. It has many advantages such as fast response, wide viewing angle, low weight, and simple manufacturing process for fabrication. However, there are some disadvantages and one of them is the image quality degradation, which is dependent on the digital signal processing. Although image quality of PDP is improving by many researches and experimentations, it still isn't as good as that of CRT because of various factors. One of them is worm-like pattern generated by an error diffusion process. And the worm-like pattern is severely increased after an APL process. An increased worm-like pattern occur a drop of resolution in image and a change of CCT according to each grayscale. In this paper, a method for improvement of image quality using the error diffusion which considers the APL process is proposed. In the proposed method, the APL process is performed before the error diffusion process. Simulation results showed that the proposed method has better performances for resolution in images and CCT uniformity according to each grayscale than the conventional method.

  • PDF

High Performance and Low Cost Single Switch Energy Recovery Display Driver for AC Plasma Display Panel

  • Han Sang Kyoo;Moon Gun-Woo;Youn Myung Joong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.723-727
    • /
    • 2004
  • A new high-performance and low cost single switch energy recovery display driver for an AC plasma display panel (PDP) is proposed. Since it is composed of only one auxiliary power switch, two small inductors, and eight diodes compared with the conventional circuit consisting of four auxiliary power switches, two small inductors, eight power diodes, and two external capacitors, it features a much simpler structure and lower cost. Nevertheless, since the rootmean-square (RMS) value of the inductor current is very small, it also has very desirable advantages such as n low conduction loss and high efficiency. Furthermore, there are no serious voltage-drops caused by the large gas-discharge current with the aid of the discharge current compensation, which can also greatly reduce the current flowing through power switches and maintain the panel to light at n lower sustaining voltage. In addition, all main power switches are turned on under the zero-voltage switching (ZVS) and thus, the proposed circuit has a improved EMI, increased reliability, and high efficiency. Therefore, the proposed circuit will be well suited to the wall hanging PDP TV. To confirm the validity of the proposed circuit, circuit operations, features,and design considerations are presented and verified experimentally on a 6-inch PDP, 50kHz-switching frequency, and sustaining voltage 141V based prototype.

  • PDF

The study on the electrical and optical characteristics of a new structure for color ac plasma displays (새로운 전극구조를 가진 ac-PDP의 전기 광학적 특성에 관한 연구 (I))

  • Lee, Woo-Geun;Shin, Joong-Hong;Kim, Joon-Ho;Kim, Doo-Han;Cho, Jung-Soo;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2227-2229
    • /
    • 1999
  • As a direct-view flat panel displays, there are many devices, such as plasma display panels(PDPs), vacuum fluorescent displays (VFDs), and light emitting diode(LED). Among these, a PDP is the first type of panel display to be made commercially available. A 'Plasma display' is the general term for a flat display utilizing the light emission that is produced by gas discharge. However, the brightness and Luminous efficiency are still not adequate for consumer television. So, the new sustain electrode type of ac PDP was proposed. By arranging the transparent electrode of quadrangle by zigzag, the area of electrode are reduced, and the length of electrode gap is increased. It generates a high luminous efficiency(corresponding to a 40% improvement of standard type), the same discharge voltage characteristics, and the low power consumption at same luminance.

  • PDF

Temporal Image Sticking Phenomena and Reducing Methods in AC PDP

  • Tae, Heung-Sik;Han, Jin-Won;Cho, Byung-Gwon;Chien, Sung-Il
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.176-179
    • /
    • 2004
  • The effects of a temporal image sticking phenomenon on the subsequent dark and white background images are investigated in 42-inch PDP-TV and the reducing method is proposed In addition, the changes in luminance and temperature with an increase in time with the conventional and large sustain gap. The temporal dark image sticking was reduced considerably by decreasing background luminance and it was found that the temporal image sticking with large sustain gap was reduced when compared with the conventional sustain gap.

  • PDF