• 제목/요약/키워드: PDP (Plasma display panel

검색결과 564건 처리시간 0.037초

High Frequency and High Luminance AC-PDP Sustaining Driver

  • Choi Seong-Wook;Han Sang-Kyoo;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • 제6권1호
    • /
    • pp.73-82
    • /
    • 2006
  • Plasma display panels (PDPs) have a serious thermal problem, because the luminance efficiency of a conventional PDP is about 1.5 1m/W and it is less than $3\~5\;lm/W$ of a cathode ray tube (CRT). Thus there is a need for improving the luminance efficiency of the PDP. There are several approaches to improve the luminance efficiency of the PDP and we adopted a driving PDP at high frequency range from 400kHz up to over 700kHz. Since a PDP is regarded as an equivalent inherent capacitance, many types of sustaining drivers have been proposed and widely used to recover the energy stored in the PDP. However, these circuits have some drawbacks for driving PDPs at high frequency ranges. In this paper, we investigate the effect of the parasitic components on the PDP itself and on the driver when the reactive energy of the panel is recovered. Various drivers are classified and evaluated based on their suitability for high frequency drivers. Finally, a current-fed driver with a DC input voltage bias is proposed. This driver overcomes the effect of parasitic components in the panel and driver. It fully achieves a ZVS of all full-bridge switches and reduces the transition time of the panel polarity. It is tested to validate the high frequency sustaining driver and the experimental results are presented.

진단 X-ray 범위에서의 Plasma Display Panel의 X-ray에 대한 전기적 반응 특성 평가

  • 허은실;윤민석;정재훈;이영규;문치웅;강상식;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.373-373
    • /
    • 2010
  • 본 논문에서는 Display용 PDP(Plasma Display panel)를 디지털 X-ray Detector로 적용하기 위해 Panel 내 Xe gas와 Ne gas의 비율을 달리하며 X-ray에 대한 기본적인 전기적 반응 특성을 연구하였다. 연구에 사용된 panel 은 상용화된 Display용 PDP를 5inch의 크기로 소형화한 sample을 제작하여 사용하였다. 제작된 sample panel의 구조는 기본적으로 Display용 PDP의 구조와 일치한다. 제작된 Sample panel의 X-선 검출기로서의 전기적 특성을 조사하기 위해 기본적인 전기특성인 Dark current, X-ray sensitivity, 그리고 Linearity를 측정하였다. 측정 결과, 진단 범위에서 충분한 전기적 Sensitivity 보이며, 선형적 특성 또한 우수한 결과를 보이는 등 안정된 전기적 동작특성을 보였다. 이러한 결과로부터 기존에 사용되어오던 Display용 PDP에 새로운 X선 변환층을 추가하고, 효율을 더욱 높일 수 있는 구조 변경을 통하여 상용화된 PDP를 디지털 X-선 검출기로서의 적용 가능성을 확인할 수 있었다.

  • PDF

PDP 유동장 PIV 계측 (PIV Measurement on the Flows of PDP(Plasma Display Panel))

  • 도덕희;조경래;송주석;백태실;편용범;정우만
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.733-737
    • /
    • 2001
  • Heat generated from the electronic parts in PDP is undesirable physical properties. To attain optimal arrangement of the electronic parts in PDP, thermal flows in PDP should be analyzed. PIV measurement has been made to quantify the characteristics of the inner flows and outer flows of an actual PDP. The quantity of heat flux from PDP has been estimated using the PIV results. Measurement system consists of Ar-ion laser, CCD camera and an image grabber installed on a host computer.

  • PDF

고효율 PDP를 위한 진공 인라인 실장에서의 MgO 보호막 영향분석 (MgO Thin Film Characterization in a Vacuum In-line Sealing Process for High-efficiency PDP)

  • 권상직;장찬규
    • 한국전기전자재료학회논문지
    • /
    • 제18권11호
    • /
    • pp.1019-1023
    • /
    • 2005
  • We have examined the electrical and optical characteristics of the plasma display panel produced by vacuum in-line sealing technology. In the MgO layer deposited at room temperature, after sealing at the panel temperature of $430^{\circ}C$, the luminous efficiency decreased compared with that of the panel before sealing. Moreover, firing and sustain voltage of the sealed panel increased compared with that of the panel before sealing. This was resulted from that the MgO protective layer was cracked by the softening of the dielectric layer during the sealing process. In order to avoid the MgO crack during the vacuum in-line sealing, thermally stable MgO layer or lower temperature sealing is required.

Thermal characteristics variation of PDP in compliance with dielectric loss

  • Lee, Tae-Ho;Jung, Jae-Chul;Lee, Sang-Kuk;Kim, Joong-Kyun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.265-268
    • /
    • 2009
  • The discharge condition of Plasma display panel(PDP) changes as the display time increases. Imaginary part of permittivity of dielectric material which is related to dielectric loss has been often neglected because of relatively small value compare to that of the real part. The thermal characteristics of PDPs with two different dielectrics has been studied and compared.

  • PDF

PDP 프레임 자동시각검사 시스템 설계 및 구현 (Design and Implementation of an Automated Visual Inspection System of PDP Frames)

  • 박병준;한광수;신은석
    • 한국멀티미디어학회논문지
    • /
    • 제13권4호
    • /
    • pp.512-525
    • /
    • 2010
  • PDP(Plasma Display Panel) 프레임은 PDP의 핵심 부품으로 매월 수 십 만개 이상을 생산하고 있다. 대량생산 과정에서 제품의 검사 과정은 매우 중요한 공정 단계이며 제품의 신뢰성을 높이기 위해 모든 부품과 완제품에 대한 전수 검사가 종종 요구되고 있다. 본 논문에서 구현 하고자 하는 시각 검사 공정의 자동화는 생산 현장에서 컴퓨터 비전 기술을 이용하여 PDP 부품의 일부인 프레임의 결함을 검사한다. 본 논문은 PDP 프레임에 있는 홀(Hole), 탭홀(Tab), 스터드(STUD), 리벳(Rivet)의 결함을 검사하는 시스템을 설계하고 구현 하였다. 본 시스템은 다양한 종류의 PDP 프레임을 학습하고 검사 할 수 있다. 모든 제품에 대한 신속하고 정확하게 100% 검사를 함으로써 공정의 효율성을 높이고 검사결과의 데이터베이스화로 신속한 결함의 원인파악과 조치가 가능하도록 하였다. 시스템을 산업체에 적용한 결과 신속하고 정확한 검사가 가능함을 보였다.

Design And Implementation of a Novel Sustain Driver for Plasma Display Panel

  • Agarwal Pankaj;Kim Woo-Sup;Cho Bo-Hyung
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.403-405
    • /
    • 2006
  • Over the years, plasma display panel (PDP) manufacturers have impressed the flat panel display industry with yet another new product essentially having the merits of a larger screen size. Since larger size implies higher power ratings, voltage/current ratings of the power devices used have become a rising concern. Another important concern is the brightness of PDP, one way of increasing which is by operating the PDP at higher frequencies. In order to address the above issues, a transformer coupled sustain-driver for AC-PDP is proposed During the transition time, the two windings of the transformer greatly boost up the displacement current flowing through the panel capacitance and hence enable a fast inversion of the voltage polarity with practical values of resonant inductance. In the proposed topology, the resonant inductance can be increased by a factor of $(n+1)^2$ as compared to prior approaches. Increased inductance results in lower current stresses. Moreover, high frequency operation is possible by using higher value of n (turn ratio of the transformer). The operational principle and design procedure of the proposed circuit are presented with theoretical analysis. The validity of the proposed sustain driver is established through simulation and experimental results using a 42-in PDP

  • PDF

PDP의 가격절감을 위한 새로운 방전 AND Gate 및 구동기술에 관한 연구 (A Study on the New Discharge AND Gate and Drive Scheme for the Cost Down of the PDPs)

  • 염정덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권6호
    • /
    • pp.267-273
    • /
    • 2003
  • The plasma display panel with the electrode structure of new discharge AND gate and its driving scheme were proposed and the driving system for experiment was developed. And operation of these discharge AND gate was verified by the experiment of PDP addressing with floating electrode. This discharge AND gate operated by the operation speed of 8$mutextrm{s}$ and the operation margin of 100V. The address operation margin of 10V also obtained. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because proposed method uses the DC discharge the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the input discharge and the output discharge of discharge gate are separate, the display discharge can be prevented from passing discharge gates. Therefore, it is possible to apply to the large screen plasma display panel. And the decrease of contrast ratio does not occur because the scanning discharge does not influence the picture quality.

Analysis on the Aging Process of ac-Plasma Display Panel

  • Park, Min-Soo;Park, Deok-Hai;Kim, Bo-Hyun;Ryu, Byung-Gil;Kim, Sung-Tae;Seo, Gi-Weon;Kim, Dae-Young;Park, Seung-Tea;Kim, Jong-Bin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.126-129
    • /
    • 2006
  • AC-plasma display panels were examined before and after the aging process to analyze the effect of the aging process. The gas analysis was done to detect the impurity gases out of the MgO film and phosphor by a residual gas analyzer. There were no differences found in the components. The MgO film was analyzed to find out the effect of an ion bombardment due to discharge. The surface roughness of the MgO film was different from regional groups due to the different degree of ion bombardments. XPS analysis showed that the 8 hour aging process was not sufficient to remove $Mg(OH)_2$ and $MgCO_3$ existed on the MgO surface. Photoluminescence measurement showed the small deterioration of blue and green phosphor.

  • PDF

PDP 격벽용 금형의 마이크로 홈 연삭 특성 (Characteristics of Micro Groove grinding for the Mold of PDP Barrier Ribs)

  • 조인호;정상철;박준민;정해도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.963-966
    • /
    • 2000
  • Plasma display panel (PDP) is a type of flat panel display utilizing the light emission that is produced by gas discharge. Barrier Ribs of PDP separating each sub-pixel prevents optical and electrical crosstalk from adjacent sub-pixels. Mold for forming barrier ribs has been newly researched to overcome the disadvantages of conventional manufacturing process such as screen printing, sand-blasting and photosensitive glass methods. Mold for PDP barrier ribs have stripes of micro grooves transferring stripes of glass-material wall. In this paper. Stripes of grooves of which width 48 um, depth 124um, pitch 274um was acquired by machining the material of WC with dicing saw blade. Maximum roughness of the bottom and sidewall of the grooves was respectively 120 nm, 287 nm. Maximum tilt angle caused by difference between upper-most width and lower-most width was 2$^{\circ}$. Maximum Radius of curvature of bottom was 7.75 ${\mu}{\textrm}{m}$. This results meets the specification for barrier ribs of 50 inch XGA PDP. Forming the glass paste will be followed by using mold in the near future.

  • PDF