• 제목/요약/키워드: PD quantities

검색결과 29건 처리시간 0.022초

고압전동기 모델 코일의 절연상태 분석 (Analysis of Insulation Condition in High Voltage Motor Model Coils)

  • 김희동;공태식;김병래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1612-1614
    • /
    • 2003
  • 80pF capacitive couplers were connected to six 6.6kV motor model coil terminals. The voltage applied to the coils were 3.81kv, 4.76 kV and 6.6kV, respectively. These stator coils have various types of artificial insulation defects such as large voids, semi-conductive coating damage and strand insulation fault. Digital PD detector(PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in PD were measured with a conventional digital PD detector. Most of the defect mechanism of large motor stator winding can be associated with PD patterns such as internal and slot discharges. PD patterns coincide with PDD and TGA. These instruments have an input bandwidth of 40-400kHz and 0.1-350MHz. Surge testing detects faults in inter-turn winding of high voltage motor model coils.

  • PDF

Development of an Algorithm for the Automatic Quantity Estimation of Wall Rebar

  • Kim, Do-Yeong;Suh, Sangwook;Kim, Sunkuk;Lwun Poe Khant
    • 한국건설관리학회논문집
    • /
    • 제24권5호
    • /
    • pp.83-94
    • /
    • 2023
  • In order to devise a rebar usage optimization algorithm, it is necessary to calculate the exact rebar length and revise the arrangement of rebars into special lengths. However, the process of rearranging numerous rebars and manually calculating their quantities is time-consuming and requires significant human resources. To address this challenge, it is necessary to develop an algorithm that can automatically estimate the length of rebars and calculate their quantities. This study aims to create an automatic estimation algorithm that improves work efficiency while ensuring accurate and reliable calculations of rebar quantities. The algorithm considers various factors such as concrete cover, hook length, development length, and lapping length, mandated by the building codes, to calculate the quantity of rebars for wall structures. The effectiveness of the proposed method is validated by comparing the rebar quantities generated by the algorithm with manually calculated quantities, resulting in a difference rate of 1.14% for the hook case and 1.37% for the U-bar case. The implementation of this method enables fast and precise estimation of rebar quantities, adhering to relevant regulatory codes.

Partial Discharge Characteristics in LLDPE-Natural Rubber Blends: Correlating Electrical Quantities with Surface Degradation

  • Aulia, Aulia;Ahmad, Mohd Hafizi;Abdul-Malek, Zulkurnain;Arief, Yanuar Z.;Lau, KwanYiew;Novizon, Novizon
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.699-706
    • /
    • 2016
  • Partial discharges (PD) lead to the degradation of high voltage cables and accessories. PD activities occur due to the existence of impurities, voids, contaminants, defects and protrusions during the manufacture and installation of power cables. Commonly, insulation failures occur at cable joints and terminations, caused by inhomogeneous electric field distributions. In this work, a blend of natural rubber (NR) and linear low density polyethylene (LLDPE) was investigated, and the optimal formulation of the blend that could resist PD was discussed. The experiments were conducted under a constant high voltage stress test of 6.5 kV AC and the magnitude of partial discharge activities was recorded using the CIGRE method II. Pattern analysis of PD signals was performed along with the interpretation of morphological changes. The results showed that the addition of 10 wt% of NR and 5 wt% of Alumina Trihydrate (ATH) provided promising results in resisting PD activities. However, as the NR content increased, more micropores existed, thus resulting in increased PD activities within the samples.

고압회전기 고정자 권선의 부분방전 측정 (Partial Discharge Measurements of High Voltage Rotating Machine Stator Windings)

  • 김희동;이영준;공태식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1828-1830
    • /
    • 2003
  • Partial discharge(PD) tests are used to evaluate the insulation condition of stator windings in two 4.16kV and three 6.6kV motors. These tests were conducted using a conventional partial discharge detector(PDD) and turbine generator analyzer(TGA). Off-line PD measurements were performed on five high voltage motors. PD magnitudes ranged from 1000 pC to 5400 pC at the normal line-to-ground voltage. Five high voltage motors have been equipped with 80pF epoxy-mica coupler on the motor terminal box. The PD pulse from sensors were measured with the TGA instrument. TGA summarizes each plot with two Quantities such as the peak PD magnitude(Qm) and the total PD activity(NQN). The defect mechanisms of high voltage motor can be associated with PD patterns such as internal, slot and conductor surface discharges. The PDD and TGA test results of No. 4 motor showed that internal discharge was detected in voids of the groundwall insulation.

  • PDF

고압전동기 결함신호의 특징추출에 관한 연구 (Feature Extraction for Fault Signals of High Voltage Motor Stator Windings)

  • 박재준;김희동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1154-1157
    • /
    • 2004
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in imitation stator winding of high voltage motors. The motor was energized to 4.47kV, 6.67, respectively. Applied voltage to Imitation winding was used two voltage level, 4.47[KV]and 6.67[KV]. Motors having imitation stator winding were installed with 80pF capacitive couplers at the terminal box Case of PD Pattern regarding applied voltage phase angel, the PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). As the result, we could discrimidate using TGA the difference of internal and surface discharge for imitation stator winding. We have used the other technique, in order to feature extraction of faulty signals on stator winding, Daubechies Discrete wavelet transform and Harmonics analysis(FFT) about faulty signals.

  • PDF

침전극의 곡율반경에 따른 트리개시전계 및 트리진전 특성 (Dependence of needle tip Curvature of the Inception Stress and Propagation of electrical tree)

  • 박영국;김완수;이홍규;이용희;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.59-62
    • /
    • 1999
  • Inception and propagation of electrical tree and properties of Partial discharge(PD) pulses accompanying with tree as a function of needle tip radius in low density polyethylene were discussed. To study on these characteristics in different tip radius, we used specimens with needle-plane electrode system made of LDPE, observed inception and propagation of electrical tree by optical microscope with computer and investigated the characteristics of the phase resolved PD pulses accompanying with propagation of electrical tree. The PD quantities detected and analysed were PD magnitude, mean phase angle, average discharge, and the statistical characteristics of the PD pulses. As the tip radius ${\gamma}$ increases, tree inception stress E$\sub$i/ converges to constance value. This result suggests that tree inception stress E$\sub$i/ increases due to stress relaxation when the tip radius is small. Branch-type electrical tree was formed When E$\sub$i/ is 640-750[kV/mm]. bush-type electrical tree when E$\sub$i/ is 370∼400[kV/mm], branch-like electrical tree when E$\sub$i/ is 370-400[kV/mm].

  • PDF

GIS에서 주파수 특성을 갖는 이중 대역법에 의한 UHF 부분방전 측정기술 (UHF Partial Discharge Measurement Technology using a Dual Bands Methods to have the Frequency Characteristics in GIS)

  • 이상화;선종호;강동식;김광화
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권3호
    • /
    • pp.127-133
    • /
    • 2006
  • This Paper describes a dual bands PD measurement method which has two different bandwidths. The one bandwidth is 0.5 - 2 GHz and the other is 1 - 2GHz. This method is used for GIS diagnosis. In the experiment, it shows that the ratios between two PD quantities in dual bands depend on the defect types and gas pressures. The variations of ratios in different pressures are more sensitive than ones in defect types. And These ratios increase with increasing SF6 gas pressures. As these ratios give us additive information of PD we can analyze the defect type as well as risk assessment for the GIS reliably. Therefore the above result shows that these ratios are one of parameters for diagnosing GIS.

Metal Ion Released from Old Prostheses May Affect Oral Lesions: A Pilot Study

  • Ju, Hye-Min;Kim, Ji-Su;Ahn, Yong-Woo;Ok, Soo-Min;Jeong, Sung-Hee
    • Journal of Oral Medicine and Pain
    • /
    • 제43권4호
    • /
    • pp.131-135
    • /
    • 2018
  • Purpose: To investigate the correlation between the amount of salivary metal ions released from fixed prostheses and the period of restoration insertion, and to evaluate the correlation between the type and amount of metal ions in saliva and oral lesions (OL). Methods: Based on the oldest prosthesis, we divided patients into two groups: more than 5 years (n=19) and less than 5 years (n=10). Patients were also divided into two groups by another criteria: the one with the presence (n=15), and the one with absence (n=14) of OL, and the amounts of metal ions were examined. Metal ions-gold (Au), copper, cobalt (Co), chromium (Cr), nickel, zinc, aluminum, palladium (Pd), tin, and platinum (Pt)-were measured using laser ablation microprobe inductively coupled plasma mass spectrometry. Results: Significantly higher quantities of Co, Pt, and Pd ions were released in patients with fixed prosthesis of more than 5 years (p<0.05). Measurement of the average amount of salivary metal ions was performed on patients with and without OL - Significantly higher amounts of Cr, Pd and Au ions were released in patients with OL (p<0.05). Conclusions: Old prostheses (${\geq}5years$) released metal ions, and among them were Co, Pt and Pd ions more than others. Patients with OL showed significantly higher levels of ion release, especially Cr, Pd and Au. There was a positive correlation between the amount of a certain kind of released metal ions, especially Pd, and the development of OL. Salivary Pd ion released from old prostheses could affect the pathogenesis of OL; therefore, long-term follow-up is important.

A Study on Ni-H, Pd-H, and Pt-H Systems by Cluster Orbital Method

  • Lee, Ju-Hyeok;Lee, Keun-Woo;Kim, Ho-Jing
    • Bulletin of the Korean Chemical Society
    • /
    • 제14권2호
    • /
    • pp.225-234
    • /
    • 1993
  • As an application of the cluster orbitals proposed previously, nickel-, palladium-, and platinum-hydrogen systems are studied. Density of states, projected density of states, HOMO levels, and stabilization energies are calculated and compared with those obtained by extended Huckel method for small clusters. These calculations are extended to large clusters to find the size dependence of several physical quantities. Reduced overlap populations are also calculated to clarify the charge transfer phenomena reported earlier. The calculated physical quantities show no dependence on the cluster size. It is also found that the charge transfer occurs due to the intrinsic character of palladium, not due to the edge effect which may be present in small clusters.

SF_6 가스와 절연지의 절연계에서 가스압력에 따른 부분방전현상 (Partial Discharge Phenomenon with $SF_6$ Gas Pressures in Insulation consisting of Insulation Paper and $SF_6$ Gas)

  • 선종호;김광화;박정후;조정수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권2호
    • /
    • pp.65-71
    • /
    • 2001
  • This paper describes partial discharge phenomenon with SF6gas pressures in insulation consisting of insulation paper and SF6 gas. We made the specimens with SF6 gas gaps which exist between aramid papers and electrodes and calculated the electric field intensity in the these gaps. We measured the partial discharge inception voltages and the AC breakdown voltages with the test method of IEC 60060-2 and did the partial discharge degradation experiments with a constant voltage. According to gas pressures, the breakdown voltages in SF6gas gaps were calculated by Paschen's law. And these results showed the ability applying partial discharge inception voltages evaluation to Paschen's law and the relationship between the PD quantities occurring insulation breakdown and PD occurring area.

  • PDF