• 제목/요약/키워드: PD pattern

검색결과 239건 처리시간 0.031초

Time-Frequency Distribution to Partial Discharge Kinds (부분방전 종류에 따른 Time-Frequency 분포)

  • Lee, D.Z.;Song, H.S.;Jung, Y.K.;Kwak, H.R.;Kim, K.W.;Kim, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1665-1667
    • /
    • 2002
  • In this paper, a comparative study of time-frequency distributions by partial discharge(PD) kinds was made. The PD kinds were to be classified into the corona, the surface discharge and the void discharge in this paper. As a result, the distributions of the PD kinds were different, and using neural network, the PD pattern recognizing rate was about 85[%].

  • PDF

Partial Discharge Properties of High Voltage Motor Stator Insulation using Partial Discharge Analyzer (PDA를 이용한 고압전동기 고정자 권선에서 부분방전 특성)

  • Kim, Hee-Dong;Lee, Sang-Kil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.225-228
    • /
    • 2001
  • Partial discharge(PD) testing for different capacitive couplers was performed on a 6.6kV, 448kW pulverizer motor. The motor has been in service for twenty years. PD tests were measured using digital partial discharge detector(DPDD) and partial discharge analyzer(PDA), respectively. PDA is used to in the motor stator insulation, which three 80pF or three 500pF epoxy-mica couplers were installed, one per phase. The 500pF couplers did detect more normalized quantity number(NQN) than the 80pF couplers. DPDD and PDA showed that PD and NQN magnitudes increased with increase of ac voltage. Internal discharge was discovered in the motor stator insulation. DPDD and PDA test results are in accordance with the pattern and magnitude of PD.

  • PDF

On-line Insulation Diagnostic by PD Monitoring Field Practical of UHF Technique for On-line PD Monitoring (UHF 기술을 이용한 온라인 부분방전 모니터링)

  • Oh, Yong;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • 제57권2호
    • /
    • pp.176-180
    • /
    • 2008
  • A field-oriented UHF system for on-line PD monitoring of transformers is designed, which has been installed inside the oil tank of transformer in a substation by two ways: on-line installing mode through the oil-valve and pre-installing mode through the man hole/hand hole cover. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

Detection Characteristics of a Novel Coupler for GIS PD Detection

  • Park, Jae-Gu;Yi, Sang-Hwa;Kim, Kwang-Hwa;Kim, Ik-Soo;Kim, Jae-Chul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권6호
    • /
    • pp.224-229
    • /
    • 2003
  • An ultra high frequency (UHF) coupler possessing ultra wide band (UWB) characteristics ranging from hundreds of MHz to several GHz is desirable for the detection of the partial discharge (PD) pulses because the pulses propagate with rise time shorter than one nanosecond in a gas-insulated substation (GIS). Thus, the authors have proposed a log-periodic antenna for GIS PD detection. Various parameters of the coupler such as frequency bandwidth, coupler gain, radiation pattern, and coupler geometry were considered throughout the simulations. The experiments for the detection characteristics of the coupler were carried out in the mock-up GIS chamber. The results indicated that the detection characteristics of the coupler are dependent on the installation angle of the coupler, the position of the coupler in the hand hole and the existence of the spacer.

Implemention of diagnosis algorithm to traction equipment for railway (철도차량 추진시스템의 진단 알고리즘 구현)

  • Ko, Byeong-Hun;Park, Young;Kwon, Sam-Young;Park, Hyun-June;Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.500-501
    • /
    • 2007
  • The method of maintenance in railway is going to be changed to improve reliability on traction equipment. Partial discharge (PD) tests are useful to evaluate the insulation condition of stator winding. This paper describes the use of PD tests with 5 model coils which have the defects such as internal, slot discharge. The PD tests are performed with epoxy-mica coupler 500 pF at various AC voltages. The result of test shows PD pattern can correlate with the species of defects on 5 model coils.

  • PDF

A Technical Trend on UHF Techniques for On-Line PD Monitoring and Site Testing for Transformer (전력용 변압기의 온라인 PD 모니터링과 시험을 위한 UHF 기술 동향)

  • Kim, Byung-Woo;Kim, Yun-Seok;Kim, Chang-Bok;Cho, Soo-Young;Choi, Young-Il;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1972-1973
    • /
    • 2007
  • A field-oriented UHF system for on-line PD monitoring of transformers is designed, which has been installed inside the oil tank of a transformer. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF

Rexonstruction of Pd Particles Supported on Silica in the Pressure of CO as Studied by Carbon-13 NMR

  • 한옥희;Gary L. Haller;Kurt W. Zilm
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권9호
    • /
    • pp.942-947
    • /
    • 1998
  • The >$^13C$ NMR spectrum of >$^13CO$ adsorbed on Pd particles varies dramatically depending on dispersion. The spectrum of highly dispersed Pd particles supported on silica is a powder pattern ∼800 ppm wide with a first moment of 410 ppm. A low dispersion sample has a motionally narrowed line centered at 750±30 ppm and only ∼85 ppm full width at half height (FWHH). Over several years, high dispersion samples show an increase in the intensity near 750 ppm. These observations are interpreted as an increase of mobile bridging CO on high dispersion Pd surfaces of particles which resulted from smoothing of the metal particle surfaces in the presence of CO.

Polyubiquitin-Proteasomal Degradation of Leucine-Rich Repeat Kinase 2 Wildtype and G2019S

  • Park, Sangwook
    • Biomedical Science Letters
    • /
    • 제27권3호
    • /
    • pp.182-186
    • /
    • 2021
  • Parkinson disease (PD) is becoming one of the most neurodegenerative disorder worldwide. The deposited aggregates have been connected in the pathophysiology of PD, which are degraded either by ubiquitin-proteasomal system (UPS) or autophagy-lysosomal pathway (ALP). Leucin-rich repeat kinase 2 (LRRK2), one of the neurodegenerative proteins of PD is also stringently controlled by both UPS and ALP degradation as well. However, the polyubiquitination pattern of LRRK2 aggregates is largely unknown. Here, we found that K63-linked polyubiquitinations of G2019S mutant, most familial variant for PD, is highly enhanced compared to those of wild type LRRK2 (WT). In addition, in the presence of overexpressed p62/SQSTM-1, ubiquitination of LRRK2 WT or D1994A was reduced, whereas G2019S mutant was not diminished significantly. Therefore, we propose that degradation of G2019S via UPS is more involved with K63-linked ubiquitination than K48-linked ubiquitination, and overexpressed p62/SQSTM-1 does not enhance degradative effect on G2019S variant.

Some Considerations on the Problems of PSA(Pulse Sequence Analysis) as a Partial Discharge Analysis Method (부분방전 해석 방법으로 PSA(Pulse Sequence Analysis)의 문제점에 대한 고찰)

  • Kim, Jeong-Tae;Lee, Ho-Keun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.327-330
    • /
    • 2004
  • Because of its effectiveness for the PD(partial discharge) pattern recognition, PSA(Pulse Sequence Analysis) has been considered as a new analytic method instead of conventional PRPDA(Phase Resolved Partial Discharge Analysis). However, PSA has a big problem that can misanalyze patterns in case of data missing resulting from poor sensitivity because it analyses the correlation between sequential pulses, which leads to hesitate to apply it to on-site. Therefore, in this paper, the problems of PSA such as data missing and noise adding cases were investigated. For the purpose, PD data obtained from various defects including noise adding data were used and analysed, The result showed that both cases can cause fatal errors in recognizing PD patterns. In case of the data missing, the error depends on the kinds of defect and the degree of degradation. Also, it could be noticed that the error due to adding noises was larger than that due to some data missing.

  • PDF

Partial Discharge Characteristics of Silicone Rubber for Insulator by Impurities (불순물에 따른 애자용 실리콘고무의 부분방전특성)

  • Kim, T.Y.;Lee, H.J.;Shin, H.T.;Lee, C.H.;Lee, D.J.;Kim, W.K.;Hong, J.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.506-509
    • /
    • 2003
  • In this paper, the $\Phi$-q-n pattern and average discharge power of silicone rubber have investigated effect of inter impurities. It's changed impurities by silicone oil, water and copper. Applied voltage is AC 3, 4, 4.5, 5, 5.5[kV]. And data acquisition time is 10 second(600 cycles). These results suggest that partial discharge(PD) is shower negative polar than positive polar at 3[kV]. Positive polar's PD value increased with increase of applied voltage. The Conductivities expressed same $\Phi$-q-n pattern in positive polar and negative polar at phase region.

  • PDF