• Title/Summary/Keyword: PD detection

Search Result 270, Processing Time 0.027 seconds

Detection of Microbial Growth in an Automated Culture System (자동배양기를 이용한 미생물 검출)

  • Sung, Hye-Ran;Kim, Il-Hoi;Kim, Jee-Youn;Lee, Chong-Kil;Chung, Yeon-Bok;Han, Sang-Bae;Song, Suk-Gil
    • Korean Journal of Microbiology
    • /
    • v.44 no.2
    • /
    • pp.130-134
    • /
    • 2008
  • Modern automated culture systems have increased the isolation rate of microorganisms and shortened the time to detection, reducing experimental errors in diagnosis of infecting agents. BacT/ALERT 3D system is based on the colorimetric detection of $CO_2$ produced by the growing microorganisms. In order to evaluate the efficiency of the detection system, sterility test were performed using 6 bacteria. With standard aerobic and anaerobic bottles containing the liquid media, both three aerobic bacteria (P. aeruginosa, M. luteus, B. subtilis) and a facultative bacterium S. aureus were detected up to 1 CFU in 31.44 hr. In addition, growth of anaerobic C. sporogenes was recognized up to 1 CFU in 15.96 hr. The slowly growing bacteria P. acnes was detected up to 10,000 CFU in 129.36 hr. In comparison with conventional culture method, BacT/ALERT 3D automated culture system was more sensitive and saved detection time up to$2\sim10$ hr. Therefore, this automated culture system enables to efficiently detect bacteria in clinical samples and biological medicines.

The Acquisition of the PN Code in the DS/CDMA System Considering Phase Error and Rake Receiver (위상 오류와 레이크 수신기를 고려한 DS/CDMA 시스템의 PN 부호 획득)

  • 김원섭;장문기;박진수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.4
    • /
    • pp.527-534
    • /
    • 2002
  • In this paper, efficiency in the acquisition of the PN code of the DS/CDMA system was analyzed by using the Nakagami-m probability density function that can model diverse fading channels. The system considers the fading environment that inevitably exists in the mobile communications channel environment. To analyze the efficiency of the system, the equations related to detection probability PD and false alarm probability PFA required for the acquisition of the PN code were induced by using the Nakagami-m probability density function. They were verified through simulation. For the DS/CDMA system an adaptive serial search technique was applied to acquire the PN code. To correct phase error, the equations related to detection probability PD and false alarm probability PFA that influence the time to acquire codes were induced after adding the PLL to each branch of the Rake Receiver. By using an induced equation, detection probability PD and false alarm probability PFA were verified through simulation.

Detection Technique of Partial Discharge by a Capacitive Probe in Cast-resin Transformers (몰드변압기에서 용량성 프로브에 의한 부분방전 검출 기술)

  • Jung, Kwang-Seok;Park, Dae-Won;Cha, Hyeon-Kyu;Cha, Sang-Wook;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.4
    • /
    • pp.319-324
    • /
    • 2011
  • This paper dealt with a partial discharge (PD) detection method for insulation diagnosis in cast-resin transformers. To detect PD pulse, a planar-capacitive probe was designed and fabricated. The probe has no insulation problem and can be installed on cast-resin transformers even in operation since it does not connect with high voltage conductor. The PD measurement system consists of the capacitive probe, a coupling network of 100 [kHz] low-cutoff frequency, and an amplifier with a gain of 40 [dB] and a frequency bandwidth of 500 [Hz]~45 [MHz]. A plane-needle and a plane-plane electrode system were fabricated to simulate insulation defects in a cast-resin transformer. Sensitivity of the PD measurement system, which is evaluated by a standard calibrator was 0.35 [mV/pC] for positive and 0.45 [mV/pC] for negative, respectively. The PD detection by the capacitive probe was less sensitive than that by a coupling capacitor according to IEC 60270, but we could analyze the magnitude and the phase distribution of PD pulse.

Analysis of PD Characteristics by Types of Insulation Defects in Power Cables (전력케이블의 절연결함에 따른 부분방전 특성분석)

  • Choi, Jae-Sung;Park, Chan-Yong;Kim, Sun-Jae;Han, Ju-Seop;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1977-1983
    • /
    • 2009
  • This paper described partial discharge(PD) patterns depending on types of insulation defects in CNCO-W cable(Concentric Neutral Closs-linked Polyethylene Insulated Polyolefin-Water Proof Sheathed Power Cable). The PD measurement system consists of a coupling network, a detection impedance, and a low noise amplifier. A 16 bit, 250 MS/s data acquisition system was used to analyze PD patterns. To simulate insulation defects in a power cable, a needle with the curvature radius of $10{\mu}m$ was inserted into the insulation part. We measured phase ($\Phi$), magnitude (q), and counts (n) of PD pulse for the defects, and classified PD patterns using the PRPD (phase Resolved Partial Discharge) method. From the analysis of acquired PD signals, we could find that a unique PD pattern is formed according to the types of defect.

  • PDF

Propagation Characteristics of GIS PD Signals by Dual UHF Band Method (2)

  • Choi, Jae-Gu;Yi, Sang-Hwa;Kim, Kwang-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.136-139
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the propagation characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD detecting system in which PD signals are detected into the dual UHF band. The UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, propagation characteristics of GIS PD signals were measured in the mock-up GIS bus and it was found that the propagation characteristics of the high band showed a better result in accordance with the infernal configuration of the GIS bus than those of the full band.

  • PDF

Detection of Partial Discharges by a Monopole Antenna in Insulation Oil (모노폴 안테나를 이용한 유중 부분방전의 검출)

  • Park, Dae-Won;Lee, Jung-Yoon;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.9
    • /
    • pp.727-731
    • /
    • 2012
  • This paper dealt with the measurement and analysis of electromagnetic waves radiated from a partial discharge (PD) source in insulation oil to apply condition monitoring of oil-immersed transformers. Two types of narrow-band monopole antennas with the resonant frequency of a 500 MHz and a 1 GHz were designed and fabricated. Also, a needle-plane electrode system was manufactured to simulate PDs and the curvature radius of the needle is 10 ${\mu}m$ and the diameter of the plane is 60 mm. Electromagnetic wave was measured by the PD measurement system with the monopole antennas. Detection sensitivity of the fabricated antenna was compared for the same PD magnitude; 620 $mV_{peak}$ for the 500 MHz antenna and 960 $mV_{peak}$ for the 1 GHz antenna to the PD magnitude of 74 pC. Consequently, the 1 GHz monopole antenna is more effective to detect PDs in oil-immersed transformers.

Hydrogen-Sensing Behaviors of Pd- and Pt-SiC Schottky Diodes (Pd- 및 Pt-SiC 쇼트키 다이오드의 수소가스 감지 특성)

  • Kim, Chang-Kyo;Lee, Joo-Hun;Cho, Nam-In;Hong, Jin-Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.7
    • /
    • pp.388-393
    • /
    • 2000
  • Hydrogen-sensing behaviors of Pd- and Pt-SiC Schottky diodes, fabricated on the same SiC substrate, have been systematically compared and analyzed as a function of hydrogen concentration and temperature by I-V and$\DeltaI-t$ methods under steady-state and transient conditions. The effects of hydrogen adsorption on the device parameters such as the barrier height are investigated. The significant differences in their hydrogen sensing characteristics have been examined in terms of sensitivity limit, linearity of response, response rate, and response time. For the investigated temperature range, Pd-SiC Schottky diode shows better performance for H2 detection than Pt-SiC Schottky diode under the same testing conditions. The physical and chemical mechanisms responsible for hydrogen detection are discussed. Analysis of the steady-state reaction kinetics using I-V method confirmed that the atomistic hydrogen process is responsible for the barrier height change in the diodes.

  • PDF

Design and Fabrication of a LabView Based Partial Discharge Analyzer (LabView 기반 부분방전 분석장치의 설계 및 제작)

  • Cha, Hyeon-Kyu;Lee, Jung-Yoon;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.3
    • /
    • pp.229-235
    • /
    • 2012
  • This paper dealt with the fabrication of a partial discharge (PD) analyzer for insulation diagnosis of power facilities like transformers, cables and gas-insulated switchgears. An analytic algorithm for the phase (${\phi}$), the magnitude (q), and the pulse count (n) of PD pulse was designed and a time-frequency (TF) map algorithm was applied in the system to eliminate noises by analyzing the time and the frequency component of signals. All the algorithms were operated by a LabView graphical program. The detection circuit consists of a coupling capacitor, a detection impedance, and a low noise amplifier. A plane-plane and a point-plane electrode system were fabricated to simulate different types of insulation defects. In the experiment, we could easily understand the characteristics of PD pulses using the prototype PD analyzer.

The Novel Approach of Gene Detection by Single-neuronal Cell Manipulation (단일 도파민뉴런을 이용한 새로운 유전자발현 검출기법)

  • Jeong, Sang-Min
    • KSBB Journal
    • /
    • v.20 no.4
    • /
    • pp.323-327
    • /
    • 2005
  • RT-PCR is an useful method to investigate the expression of target gene as detection tools. Although RT-PCR is the powerful detection method for tissues, it was difficult to amplify the target gene product using the single cell. To clarify the expression level of the genes related to Parkinson's disease (PD), I performed the laser dissection of single cell from Substantia nigra. I examined the mRNA expression level in the dopaminergic neuron isolated from the PD patients by the single cell RT-PCR method. It is known that tyrosine hydroxylase (TH), DOPA decarboxylase (DDC) are involved in biosynthesis of the catecholamine such as dopamine. Little has been known about the gene expression features of these enzymes in single dopaminergic neuron. I could detect the specific gene products in single cell level. The different expression was observed in PD-related gene products from the single neuron of PD patients. Interestingly, TH gene expression was significantly decreased with comparing the ratio of decrease in other PD-related genes. Hence, I represented data that indicate the RT-PCR method described in this report is an effective method in detecting a specific single-cell mRNA level related with diseases.

A Study on the Ultrasonic Measurement of Partial Discharge (부분방전의 초음파 측정에 관한 연구)

  • Sun, J.H.;Ryoo, H.S.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1562-1564
    • /
    • 1994
  • In this paper, we describe that the acoustic PD detection is examined in the various structures and position shapes of sensors. We find that the acoustic waves rate the complexity in various structures and position shapes of sensors may reduce the complexity of the acoustic wave in the PD detection of transformers.

  • PDF