• 제목/요약/키워드: PD detection

검색결과 270건 처리시간 0.022초

Efficient Detection of Space-Time Block Codes Based on Parallel Detection

  • 김정창;전경훈
    • 한국통신학회논문지
    • /
    • 제36권2A호
    • /
    • pp.100-107
    • /
    • 2011
  • Algorithms based on the QR decomposition of the equivalent space-time channel matrix have been proved useful in the detection of V-BLAST systems. Especially, the parallel detection (PD) algorithm offers ML approaching performance up to 4 transmit antennas with reasonable complexity. We show that when directly applied to STBCs, the PD algorithm may suffer a rather significant SNR degradation over ML detection, especially at high SNRs. However, simply extending the PD algorithm to allow p ${\geq}$ 2 candidate layers, i.e. p-PD, regains almost all the loss but only at a significant increase in complexity. Here, we propose a simplification to the p-PD algorithm specific to STBCs without a corresponding sacrifice in performance. The proposed algorithm results in significant complexity reductions for moderate to high order modulations.

3차원 해석에 의한 유입변압기 PD발생점 탐지 (PD Source Detection of Oil Transformer Using Three-dimensional Construction)

  • 윤철섭;최길수;이은석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1036-1038
    • /
    • 1998
  • The while, PD source detection in the oil TR was the level of the planar source detection. and it is to respected scientific research. The planar source detection technique had limits which have difficulties finding out the point of deterioration generation. In this study, our purpose is a development of PD source detection technique with Three-Dimensional using a principle and a technique of the planar source location.

  • PDF

터빈 발전기의 부분방전 신호 중 노이즈 제거 방법 (A method to reject noise signals in partial discharge signals of turbine generator)

  • 박영훈;박부견;김성현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.240-242
    • /
    • 2005
  • It is well known that the PD (Partial Discharge) signals are generated if insulators have some defects such as voids in electrical facility and various PD detection methods are developed for preventing electrical troubles. So, an interest for the PD signals is higher and higher according to the high concern for the defects detection method of the aging electrical facility. When the equipment to detect PD signals installed at site and it works, a lot of noises flow in the equipment from surrounding situation and it will be mixed with original PD waveform. So we can not get the desired PD waveform. Therefore, there are many trial to reject or suppress the noise from the PD signals from long times ago. The greater of them used the hardware such as bridge circuits and frequency filters to suppress the noise. This paper proposed a novel noise rejection method in acquired data from PD detection equipment. The noise has the irregular phase and higher signal level than real PD, and noise decision is performed after inspection of pulse distribution in ${\Phi}$-q-n graph of acquired data from PD detection equipments. By experimental results on high voltage electric equipments, it is shown that proposed method has good performance. It is expected that this noise rejection technology is useful in numeric calculation and trend management of PD level.

  • PDF

초광대역과 단일주파수(협대역) UHF 부분방전 검출기법 비교 (Ultra-wide bandwidth versus narrow bandwidth PD detection techniques for UHF partial discharge monitoring system)

  • 박기준;구선근;윤진열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1655-1657
    • /
    • 2002
  • Ultra-wide bandwidth (UWB), narrow bandwidth (single frequency), and a combination of both technologies have been studied for the ultra-high frequency (UHF) partial discharge (PD) monitoring system as a detection scheme. We have experimentally compared those detection methods using a mock-up of 362 kV class single phase gas-insulated switchgear (GIS) and a stable PD source. A rolling-ball type PD cell that produces PDs of about 10 pC, is placed at one end of the GIS. An internal UHF PD sensor was attached several meters away from the PD source. The PD spectrum was measured up to 3 GHz. A useable bandwidth of more than 1 GHz was used to measure UWB signals from the PD. To simulate the narrow bandwidth scheme a bandwidth of 100 kHz centered at several different frequencies was used.

  • PDF

Detection Characteristics of a Novel Coupler for GIS PD Detection

  • Park, Jae-Gu;Yi, Sang-Hwa;Kim, Kwang-Hwa;Kim, Ik-Soo;Kim, Jae-Chul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권6호
    • /
    • pp.224-229
    • /
    • 2003
  • An ultra high frequency (UHF) coupler possessing ultra wide band (UWB) characteristics ranging from hundreds of MHz to several GHz is desirable for the detection of the partial discharge (PD) pulses because the pulses propagate with rise time shorter than one nanosecond in a gas-insulated substation (GIS). Thus, the authors have proposed a log-periodic antenna for GIS PD detection. Various parameters of the coupler such as frequency bandwidth, coupler gain, radiation pattern, and coupler geometry were considered throughout the simulations. The experiments for the detection characteristics of the coupler were carried out in the mock-up GIS chamber. The results indicated that the detection characteristics of the coupler are dependent on the installation angle of the coupler, the position of the coupler in the hand hole and the existence of the spacer.

A Study on the Pattern Recognition Rate of Partial Discharge in GIS using an Artificial Neural Network

  • Kang Yoon-Sik;Lee Chang-Joon;Kang Won-Jong;Lee Hee-Cheol;Park Jong-Wha
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권2호
    • /
    • pp.63-66
    • /
    • 2005
  • This paper describes analysis and pattern recognition techniques for Partial Discharge(PD) signals in Gas Insulated Switchgears (GIS). Detection of PD signals is one of the most important factors in the predictive maintenance of GIS. One of the methods of detection is electro magnetic wave detection within the Ultra High Frequency (UHF) band (300MHz $\~$ 3GHz). In this paper, PD activity simulation is generated using three types of artificial defects, which were detected by a UHF PD sensor installed in the GIS. The detected PD signals were performed on three-dimensional phi-q-n analysis. Finally, parameters were calculated and an Artificial Neural Network (ANN) was applied for PD pattern recognition. As a result, it was possible to discriminate and classify the defects.

A Real-time Pedestrian Detection based on AGMM and HOG for Embedded Surveillance

  • Nguyen, Thanh Binh;Nguyen, Van Tuan;Chung, Sun-Tae
    • 한국멀티미디어학회논문지
    • /
    • 제18권11호
    • /
    • pp.1289-1301
    • /
    • 2015
  • Pedestrian detection (PD) is an essential task in various applications and sliding window-based methods utilizing HOG (Histogram of Oriented Gradients) or HOG-like descriptors have been shown to be very effective for accurate PD. However, due to exhaustive search across images, PD methods based on sliding window usually require heavy computational time. In this paper, we propose a real-time PD method for embedded visual surveillance with fixed backgrounds. The proposed PD method employs HOG descriptors as many PD methods does, but utilizes selective search so that it can save processing time significantly. The proposed selective search is guided by restricting searching to candidate regions extracted from Adaptive Gaussian Mixture Model (AGMM)-based background subtraction technique. Moreover, approximate computation of HOG descriptor and implementation in fixed-point arithmetic mode contributes to reduction of processing time further. Possible accuracy degradation due to approximate computation is compensated by applying an appropriate one among three offline trained SVM classifiers according to sizes of candidate regions. The experimental results show that the proposed PD method significantly improves processing speed without noticeable accuracy degradation compared to the original HOG-based PD and HOG with cascade SVM so that it is a suitable real-time PD implementation for embedded surveillance systems.

A Study on the Algorithm for Detection of Partial Discharge in GIS Using the Wavelet Transform

  • J.S. Kang;S.M. Yeo;Kim, C.H.;R.K. Aggarwal
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권4호
    • /
    • pp.214-221
    • /
    • 2003
  • In view of the fact that gas insulated switchgear (GIS) is an important piece of equipment in a substation, it is highly desirable to continuously monitor the state of equipment by measuring the partial discharge (PD) activity in a GIS, as PD is a symptom of an insulation weakness/breakdown. However, since the PD signal is relatively weak and the external noise makes detection of the PD signal difficult, it therefore requires careful attention in its detection. In this paper, the algorithm for detection of PD in the GIS using the wavelet transform (WT) is proposed. The WT provides a direct quantitative measure of the spectral content and dynamic spectrum in the time-frequency domain. The most appropriate mother wavelet for this application is the Daubechies 4 (db4) wavelet. 'db4', the most commonly applied mother wavelet in the power quality analysis, is very well suited to detecting high frequency signals of very short duration, such as those associated with the PD phenomenon. The proposed algorithm is based on utilizing the absolute sum value of coefficients, which are a combination of D1 (Detail 1) and D2 (Detail 2) in multiresolution signal decomposition (MSD) based on WT after noise elimination and normalization.

분포형 광음향센싱 기반 부분방전 모니터링 기술 연구 (Partial Discharge Monitoring Technology based on Distributed Acoustic Sensing)

  • 김희운;이주영;정효영;김영호;김명진
    • 센서학회지
    • /
    • 제31권6호
    • /
    • pp.441-447
    • /
    • 2022
  • This study describes a novel method for detecting and measuring partial discharge (PD) on an electrical facility such as an insulated power cable or switchgear using fiber optic sensing technology, and a distributed acoustic sensing (DAS) system. This method has distinct advantages over traditional PD sensing techniques based on an electrical method, including immunity to electromagnetic interference (EMI), long range detection, simultaneous detection for multiple points, and exact location. In this study, we present a DAS system for PD detection with performance evaluation and experimental results in a simulated environment. The results show that the system can be applied to PD detection.

초음파 측정에 의한 변압기내 부분방전 위치측정 (Location of Partial Discharge in Oil Transformer by means of Ultrasonic measurement)

  • 곽희로;전희종;김재철;황선주;윤용한;권태원;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.415-418
    • /
    • 1991
  • This paper described an instrument for the detection and geometric location of partial discharge(PD) sources in oil transformer. This instrument measures electric current pulse and ultrasonic pulse simultaneously in order to determine the geometric location of PD in transformer. Laboratory experiment systems are made for detection and location of PD in oil transformer. It was observed that there are effects of the barrier, such as insulation papers, silicon steel plate and actual transformer with location and detection of PD in model transformer. Through the laboratory actual test, it was clarified that this measurement device could be used satisfactorily for location of pd in oil transformer.

  • PDF