• 제목/요약/키워드: PD (Partial Discharge)

검색결과 501건 처리시간 0.022초

SF6 가스절연에서 부분방전의 특성분석 (Analysis of Partial Discharge Characteristics in SF6 Gas Insulation)

  • 김선재;왕국명;박서준;길경석;안창환
    • 한국전기전자재료학회논문지
    • /
    • 제29권7호
    • /
    • pp.429-434
    • /
    • 2016
  • This paper deals with the characteristics of partial discharge (PD) for the purpose of a condition based maintenance (CBM) of gas insulated switchgears (GIS) in power equipment. Four types of electrode systems such as a protrusion on enclosure (POE), a particle on spacer (POS), a free particle (FP) and a Floating were designed and fabricated. PD pulses were measured using UHF sensor with a frequency range of 300 MHz~1.4 GHz and a DAQ with a sampling rate of 250 MS/s. Discharge inception voltage (DIV), discharge extinction voltage (DEV), and phase resolved partial discharge (PRPD) were analyzed depending on electrode systems. The average DIV in the POS was 28.8 kV. It was about 1.7 times higher than that in the FP, which was the lowest value of 17.2 kV. The FP shuffled and jumped at the applied voltage of 23.5 kV. Over 95% of PD pulses in the POE were generated in the negative polarity ($181^{\circ}{\sim}360^{\circ}$) of applied voltage. The results showed the phase (${\Phi}$)-magnitude (dBm) of PD pulses by UHF sensor, a cluster was formed separately depending on electrode systems.

고체 합성수지절연체와 표면노화 진단기술로서의 부분방전 측정평가기술에 대하여 (Partialt Discharge Measurement Techniques for Diagnosis of Surface Aging on Organic Insulation)

  • 박완기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 춘계학술대회 논문집
    • /
    • pp.50-56
    • /
    • 1994
  • Partial discharge on organic insulation surfaces are an important sauce of aging. Furthermore the modern PD measurement technigues are rapid developed as quality control and diagnostic tests to determine the fitness for use of HV equipment employing sol id electrical insulation. This paper deals with theory of conventional PD measurement and new tendency of technical development on PD measurements und evaluations. Finally the Measuring system used for diagnosing the surface aging on the organic insulation at High Voltage Laboratory of Technical University of Darmstadt in Germany is presented.

  • PDF

PD 분포 분석에 의한 견인전동기 고정자 코일의 열화도 분류에 관한 연구 (Classification of stator coil degradation of traction motor by PD signal distribution analysis)

  • 박성희;임종호;장동욱;박현준;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1183-1186
    • /
    • 2004
  • Degradation and insulation failure of traction motor depend on the continuous stress imposed on it. And knowing on insulation condition is important thing for safety operation of EMU(electric multiple unit). In this paper, PD(partial discharge) characteristics for degradation analysis of stator coil is studied. For PD data acquisition, two models are made; one is normal condition coil, the other is aged condition coil. And PD data for discrimination were acquired from PD detector. And these data making use of a computer-aided discharge analyser, statistical and other discharge parameters is calculated to discrimination between different discharge sources. And also these parameter is applied to classify PD sources by neural networks. Neural Networks has good recognition rate for degradation of stator coil.

  • PDF

3d-PD의 통계적 고찰과 신경망 응용기술 (The Application Technique on AI and Statistical Analysis of 3d-PD)

  • 임장섭;박용식;최병하;한석균
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 센서 박막재료
    • /
    • pp.66-70
    • /
    • 2001
  • The partial discharge testing is widely used in diagnostic measuring technology because it gives low stress to power equipment which is undertaken tests. Therefore it is very useful method compare to previous destructive methods and effective diagnosis method in power system that requires on-line/on-site diagnosis. But partial discharges have very complex characteristics of discharge pattern, so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated system is manufactured and HFPD occurred from those simulator is measured with broad-band antenna in real time, the degradation grade of system is analyzed through produced patterns in simulated target according to the AI/statistics processing.

  • PDF

고주파 부분방전 측정에 의한 초고압 접속함 신뢰성 평가 기술 (A Evaluation Technique for Reliability of Extra-High Voltage Cable Accessories using High Frequency Partial Discharge Measurement)

  • 신두성;이창영;김충식;전승익;김동욱;박완기
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권3호
    • /
    • pp.186-195
    • /
    • 2000
  • In this paper, partial discharge (PD) measurement was performed to evaluate the quality of the cable joint and termination constructions. The resistive coupling technique for PD detection using resistivity of semiconducting layer of the cable in the accessories, such as joints and terminations. With high frequency PD (HEPD) measurement, an excellent sensitivity below 20pC could be achieved under unshielded condition. The localization of the defects in the accessories could be identified. During heating cycle, PDs were monitored and analyzed. At that time, the PDs were dependent on the temperature of the heating cycle and showed cyclic behaviors, which were attributed to local delamination of the interfaces, between epoxy unit and stress relief cone(SRC) and between SRC and cable, due to the difference of thermal expansion. As a conclusion, HFPD measurement technique was proven to be an effective diagnostic method for qualification of extra high voltage (EHV) cable accessories. With this technique, the optimal design of the components of the accessories could be verified not only in an early stage but also under operating condition. This technique would result in the improvement of the reliability of the EHV cable accessories.

  • PDF

분포 통계 해석에 의한 계면 결함 부분방전 진단 (Partial Discharge Diagnosis of Interface Defect by the Distribution Statistical Analysis)

  • 조경순;이강원;김원종;홍진웅;신종열
    • 한국전기전자재료학회논문지
    • /
    • 제21권4호
    • /
    • pp.348-353
    • /
    • 2008
  • Most of the high voltage insulation systems, such as the power cable joint having hetero interface, are composed of more than two different insulators to improve insulating performance. The partial discharge(PD) in these hetero interface is expected to affect the total insulation performance. Thus, it is important to study electrical properties on these interfaces. This study described the influence of copper and semiconductive substance defects on $\Phi$-q-n distribution between the interface of the model cable joints to classify PD source. PD was sequentially detected for 600 cycles of the applied voltage. The K-means cluster analysis has been analyzed to investigate the $\Phi$-q-n distribution. The skewness-kurtosis(Sk-Ku) plot from K-means clustering results was defined to quantify cluster distribution and classify distribution patterns. The Sk-Ku plot is composed of skewness and kurtosis along abscissa and ordinate which indicate the asymmetry and the sharpness of distribution. As a result of the Sk-Ku plot, it was confirmed that the data was distributed in 1st 2nd and 3rd quadrant at copper foreign substance defect, but in case of semiconductive foreign substance, the data was distributed in 2nd quadrant only.

인가전압에 따른 모의변압기의 HFPD 특성분석 (HFPD Characteristic Analysis of Simulated Transformer According To Applied Voltage)

  • 김덕근;임영삼;임장섭;문채주;이진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1957-1959
    • /
    • 2000
  • The PD measurement method is very useful to detect insulation degradation. Recently, the HFPD(High Frequency Partial Discharge) measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires in-service diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In this study, simulated transformer is manufactured and HFPD occurred from simulated transformer is measured with broad band antenna and active-line RF measurement system in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages. Also the PD pattern which was measured with EMC analyzer and RF measurement system is compared.

  • PDF

저압용 전기전자기기에 부분방전시험의 적용을 위한 기초연구 (A Basic Study on the Application of Partial Discharge Test on Low-voltage Electrical and Electronic Devices)

  • 길경석;송재용;문승보;차명수;황돈하;강동식
    • 한국전기전자재료학회논문지
    • /
    • 제19권6호
    • /
    • pp.586-590
    • /
    • 2006
  • This paper deals with the application of a partial discharge (PD) test on low-voltage electrical and electronic devices, which is recently being accepted as a non-destructive and a effective dielectric test method. A comparative analysis combined with the Withstand Voltage Test (WVT) specified in IEC standards was carried out on low-voltage insulation transformers. The results showed that the WVT causes insulation degradation of the specimen during the test by applying high voltage. However, the PD test can be performed in ranges from 30 % to 50 % of the test voltage specified in the WVT. Therefore, the PD test is successfully applicable for a non-destructive test method on low-voltage electrical and electronic devices as a replacement of the WVT.

Analysis of Partial Discharge Inception Voltages for the Wrong Positioning Defects in the Joint of Distribution Power Cables

  • Kim, Jeong-Tae;Kim, Dong-Uk;Lee, Young-Jo;Koo, Ja-Yoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.977-982
    • /
    • 2012
  • In order to find out partial discharge (PD) phenomena in the cable joint due to the poor workmanship during the installation, the relationship between PD inception voltages and joint defects was investigated. For the purpose, in the joint of 22.9kV CNCV cables, electric fields were calculated for various semiconductive layer wrong positioning (WP) defects. And, PDIV were investigated through the experiments and compared with the results of electric field analysis. In all WP defect cases, the PD inception field calculated using measured PDIVs was similarly shown to be the average value of 1.84kV/mm. In addition, the calculated PDIV and the measured PDIV were almost equal, from the PDIV calculation using maximum electric fields and the measured PDIV for the normal case. Throughout this study, it is possible to analyze WP defects due to the poor workmanship and to establish better joint design for the distribution grade extruded cable system.

GIS내 파티클에 의한 PD의 패턴인식 (Pattern Recognition of PD by Particles in GIS)

  • 곽희로;이동준
    • 조명전기설비학회논문지
    • /
    • 제17권1호
    • /
    • pp.31-36
    • /
    • 2003
  • 본 논문은 GIS내 파티클에 의해 발생한 부분방전 신호에 대한 정량적 분석 및 상태에 따른 패턴인식에 관하여 설명하였다. GIS내 파티클의 상태를 4가지로 모의하여 각각의 경우에 부분방전 신호를 계측한 후 Ф-Q-N분포로 나타내었고, 다시 Ф-Q분포, Ф-Qm분포, Ф-N분포, Ф-N분포로 나타내었다. 각각의 분포는 통계적 연산자에 의해 정량화 하여 분석하였고, 또한 연산자들을 패턴인식을 위한 입력데이터로 이용하여 수행하였다. 그 결과 파티클의 상태에 따른 분포 형태는 파티클의 상태에 따라 서로 다른 특성을 나타냈었으며, 또한 뉴럴 네트웍을 이용한 패턴 인식의 결과는 약92〔%〕였으며 연산자들의 입력 데이터가 많을수록 더 정확한 결과가 나타났다.