• Title/Summary/Keyword: PCR 장치

Search Result 26, Processing Time 0.028 seconds

Design and Implementation of Firmware for Low-cost Small PCR Devices (저가의 소형 PCR 장치를 위한 펌웨어 설계 및 구현)

  • Lee, Wan Yeon;Kim, Jong Dae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.6
    • /
    • pp.1-8
    • /
    • 2013
  • In this paper, we design and implement a firmware for low-cost small PCR devices. To minimize machine code size, the proposed firmware controls real-time tasks simultaneously only with support of the hardware interrupt, but without support of the operating system program. The proposed firmware has the host-local structure in which the firmware receives operation commands from PC and sends operation results to PC through usb communication. We implement a low-cost small PCR device with the proposed firmware loaded on microchip PIC18F4550 chip, and verify that the implemented PCR device significantly reduces cost and volume size of existing commercial PCR devices with a similar performance.

Development of Tenderness Measurement System of Beef Carcass Using Ultrasound (초음파를 이용한 한우도체 연도 측정 시스템 개발)

  • 조성인;남기찬;임용우
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.479-485
    • /
    • 2002
  • 본 연구는 초음파를 이용하여 한우도체의 연도를 비파괴적이며 객관적으로 측정할 수 있는 시스템을 개발하기 위해서 수행되었다. 한우도체 연도 측정 시스템은 크게 초음파 측정장치, 자동 탐촉자 수직이동장치, 데이터 획득 및 분석장치로 구성되었는데 초음파 측정장치는 초음파 pulser/receiver 및 탐촉자, 자동 탐촉자 이동장치는 상하운동부, 구동부, 제어부, 데이터 획득 및 분석장치는 digitizer, Labview 5.1을 사용하여 구성되었다. 통합된 시스템을 이용하여 획득된 도체의 초음파 신호를 분석하기 위해 1.0~1.1 MHz의 bandpass filtering을 거쳐 hilbert 변환을 이용, envelope를 구할 수 있었으며 탐촉자와 도체의 최적 접촉 위치를 결정하기 위하여 3단계로 나누어 신호분석을 실시하였다. 시료의 개수는 40개였으며 획득된 envelope를 FFT 변환 후 PLS, PCR 분석을 수행한 결과 7단계의 PCR 분석에서 $R^2$= 0.6474의 유의성 있는 결과를 나타내었으므로 최적 접촉 위치로 결정하였다. 최적 접촉 위치를 통해 시료 80개의 추가 실험을 실시한 결과 PCR 분석에서 $R^2$= 0.4304의 결과를 나타내었으며 이를 이용, 도체의 연도를 측정하는 프로그램을 개발하고 최종 통합 시스템을 구축하였다. 본 한우도체 연도 측정 시스템의 개발을 통해 한우도체의 전단력을 예측하여 연도를 객관적으로 판정 가능할 것으로 생각되며 또한 사이즈의 확대로 도축장에 설치하는 설비로서 가능할 것이라 사료된다. 그러나 추후 좀 더 세밀한 측정과 결과의 보완을 위한 분석방법의 개선에 관한 연구가 진행되어야 할 것이다. 사용해 설계된 장치를 사용자가 쉽게 제작할 수 있도록 하였다. 공정설계프로그램을 통해 설계된 공정은 데이터베이스에 저장이 되며 장치설계프로그램에서 쉽게 이전에 설계했던 공정을 이용할 수 있도록 하여 공정 설계와 장치설계를 연계하도록 하였다.동투하시간과 비용 -종자준비부터 통마늘선별까지의 일관기계화로 투입된 주요작업의 노력은 75∼76%가 절감되고, 재배규모 3ha기준시 비용은 44-53%절감되었음. the annealing texture. Observations by TEM and EBSD revealed the formation of very fine grains of ∼1.0$\mu\textrm{m}$ after CCSS.he dislocations form local defect arrangements at the grooves permitting the substantial reduction in defect density over the remainder of the interfacial area.한 최대의 감자 재배지역을 형성하였다. 제주도는 산지지형과 따뜻한 기온으로 2기작이 가능하고, 감자가공 공장설립과 교통발달에 따른 육지 시장과의 접근이 용이해졌기 때문에 남한에서 2번째로 큰 감자재배지역이 되었다.(요약 및 결론에서 발췌)그람양성균에서 효과적이었으며, 농도별 항균력시험 결과 농도가 증가할수록 비례하여 저해율도 증가함을 알 수 있었다. 첨가농도를 달리하여 미생물의 생육도를 측정한 결과, fraction II磎꼭\ulcorner경우 그람양성균에 대해 500 ppm 이상에서 뚜렷한 증식억제효과를 나타내었다.서 뚜렷한 증식억제효과를 나타내었다.min/+}$계

  • PDF

A Study on plasma etching for PCR manufacturing (PCR 장치를 위한 플라즈마 식각에 관한 연구)

  • Kim, Jinhyun;Ryoo, Kunkul;Lee, Jongkwon;Lee, Yoonbae;Lee, Miyoung
    • Clean Technology
    • /
    • v.9 no.3
    • /
    • pp.101-105
    • /
    • 2003
  • Plasma etching technology has been developed since it is recognized that silicon etching is very crucial in MEMS(Micro Electro Mechanical System) technology. In this study ICP(Inductive Coupled Plasma) technology was used as a new plasma etching to increase ion density without increasing ion energy, and to maintain the etching directions. This plasma etching can be used for many MEMS applications, but it has been used for PCR(Polymerase Chain Reaction) device fabrication. Platen power, Coil power and process pressure were parameters for observing the etching rate changes. Conclusively Platen power 12W, Coil power 500W, etchng/passivation cycle 6/7sec gives the etching rate of $1.2{\mu}m/min$ and sidewall profile of $90{\pm}0.7^{\circ}$, exclusively. It was concluded from this study that it was possible to minimize the environmental effect by optimizing the etching process using SF6 gas.

  • PDF

A Highly Stable Current-Controlled Power Supply (고안정 전류제어 전원장치)

  • Kwon, Bong-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.2
    • /
    • pp.144-155
    • /
    • 1992
  • A design of a highly stable current-controlled power supply combining the phase-controlled rectifier (PCR), passive filter and active filter is investigated. A digital phase-looked voltage control (PLVC) with a capability of compensating the thyristor firing angles under unvalanced power source is proposed` otherwise the PCR output voltage has low-order subharmonics whose suppression requires a bulky passive filter. The digital PLVC has a fast dynamic characteristics as an inner control loop of the PCR. To suppress further the output ripple, an active filter using a transformer is introduced and its design is described through the frequency domain analysis. An optimal integral, proportional and measurable variable feedback (IPM) controller is designed using the time-weighted performance index based on the time domain analysis. The design method based on the time-weighted performance index gives better response characteristics than that based on the conventional performance index. It is also shown via experimental results that the proposed scheme gives better response characteristics than that based on the conventional performance index. It is also shown via experimental results that the proposed scheme gives good dynamic and static performances.

Detection of Tissue-specific Expression of Porcine Cytochrome P450 Aromatase Genes by Use of Denaturing High Performance Liquid Chromatography(DHPLC) Technique (DHPLC 기술을 이용한 돼지 Cytochrome P450 Aromatase 유전자의 조직 - 특이적 발현양상 관찰)

  • Chae, S.H.;Ghlmeray, A.K.;Hong, J.M.;Lee, E.J.;Chang, J.S.;Choi, I
    • Journal of Animal Science and Technology
    • /
    • v.46 no.3
    • /
    • pp.315-324
    • /
    • 2004
  • Cytochrome P450 aromatase is the enzyme responsible for biosynthesis of female sex hormone(estrogen) and 19-nortestosterone(nandrolone), a unique steroid hormone endogenously synthesized in the pig. By use of RT-PCR coupled with DHPLC technique (WAVE analysis), expression pattern of isoforms of porcine cytochrome P450 aromatase gene was investigated. Relatively higher expression of aromatase mRNA was observed in testis than in ovary and this result accounted for the previous findings of higher blood estrogen level in male compared with female in this species. The result from the DHPLC demonstrated that PCR amplified DNA fragments of ovary and testis tissues. using unique PCR primers for all three types of aromatase genes, were different from those of type II and ill genes. Further nucleotide sequence analyses of the plasmid clones containing the PCR products revealed that nucleotide sequences of all clones were identical to type I aromatase gene(ovary type). Thus, the result from the present study indicates that the ovary and testis express the same type of aromatase gene. Therefore, the efficacy of DHPLC techniques used for this study helped us to analyze tissue-specific expression of isoform of genes containing the nucleotide sequences with high homology.

An Implementation of Digital TV Stream Analyzer (디지틸 TV 스트림 분석기 구현)

  • 정혜진;김용한
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2000.11b
    • /
    • pp.95-100
    • /
    • 2000
  • 본 논문에서는 디지털 TV 방송 스트림을 분석, 검증하기 위한 시스템을 PC 상에서 소프트웨어 기반으로 구현하였다. 저장되어 있는 MPEG-2 트란스포트 스트림(transport stream, TS) 파일을 입력으로 받으며 별도의 하드웨어 장치를 사용하지 않는다. 이 분석기는 PSI(program specific information), TS 섹션, TS 헤더 등 기본 내용뿐만 아니라, TS 패킷들을 오디오, 비디오, PCR(program clock reference), 부가 데이터, 널(null) 패킷 등으로 구분하여 그래픽 사용자 인터페이스 통하여 보여 준다. 또한, 현재 표시되고 있는 TS 패킷과 가장 가까운 I 프레임를 디스플레이 해줌으로써 비트스트림 상의 오류 부분과 실제 영상과 쉽게 매칭시킬 수 있도록 해 준다. 본 논문의 분석기는 MPEG-2 비트스트림 적합성 검사 기능도 제공하며, 데이터 방송을 위한 여러 가지 부가 데이터를 MPEG-2 기본 스트림에 삽입하는 기능도 갖고 있다. 본 논문의 분석기를 이용함으로써 저비용으로 방송 스트림을 분석, 검증할 수 있을 뿐만 아니라, 실험실 연구를 위한 데이터 방송용 비트스트림을 저비용으로 제작할 수 있다.

  • PDF

Operation diagnostic based on PCA for wastewater treatment (PCA를 이용한 하폐수처리시설 운전상태진단)

  • Jeon Byeong-Hui;Park Jang-Hwan;Jeon Myeong-Geun
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2006.05a
    • /
    • pp.96-98
    • /
    • 2006
  • 축산폐수는 축사가 대부분 상수원보다 상류지역에 산재하고 있어 이를 효과적으로 관리하기 어려우나, 연속 회분식 반응기(Sequencing Batch Reactor, SBR)는 장치가 간단하고 경제성이 우수하여 축산폐수처리에서 효율적으로 적용될 수 있다. 본 연구에서는 DO(Dissolved Oxygen)과 ORP(Oxidation-Reduction Potential)을 이용하여 지식기반 고장진단 시스템을 제안하였다. 실시간으로 얻어진 ORP, DO값들을 전처리하여, [ORP], [DO]외에 [ORP DO]합성data와 ORP, DO의 특징백터의 합에서 얻어진 fusion data의 총 4개의 data set을 이용하여 각각에 대한 진단과 분류성능을 검토하였다. 이 값을 이용하여 FCM (fuzzy C-mean) 클러스터링 한 후, K-PCA과 LDA로 차원축소시켜 특징백터를 추출하였다. 그리고 Hamming distance로 test data와 특징백터의 거리를 계산하여 각 class를 F1에서 F8까지 분류하였다. 그 결과 데이터를 그대로 이용하는 것 보다 차분데이터형태로 이용하는 것이 우수했으며 그 중 fusion 데이터의 결과가 다른 것들보다 향상된 결과를 보였다. 그리고 K-PCA와 LDA를 결합한 결과가 다른 방법에 비해 우수한 결과를 보였으며 fusion method를 이용한 최고인식율은 98.02%를 나타내었다.

  • PDF

A Power Circuit Improvement of the Hybrid System Using Phase Controlled Rectifier and PWM Converter for Magnet Load Power Supply (자석-부하 전원장치를 위한 위상제어 정류기와 PWM 컨버터를 사용한 복합구조 시스템의 전력회로 개선)

  • Kang, Min-Gu;Shon, Jin-Geun;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.231-235
    • /
    • 2008
  • Thyristor rectifiers are still the preferred choice for large magnet power supplies. However, large harmonic voltages, resulting in large current ripple, and slow dynamic response are major drawbacks of these converters. Joos presented a topology and a control technique for a hybrid large-power high-precision magnet power supply in 1996. The system consists of a phase controlled rectifier (PCR) connected in series with a high-frequency PWM converter. This paper improves the power circuit of the PWM converter using interphase transformer. Simulation result proves effect of the proposed system.

An Implementation of Digital TV Stream Analyzer (디지털 TV 스트림 분석기 구현)

  • 정혜진;김용한
    • Journal of Broadcast Engineering
    • /
    • v.6 no.1
    • /
    • pp.82-97
    • /
    • 2001
  • In this paper, we describe a software implementation of a digital TV stream analyzer that can be used for analyzing and verifying digital TV bitstreams on personal computes. It accepts as input MPEG-2 transport streams (TS's) already stored on hard disks and doesn't require any special hardware. After classifying TS packets into program specific information(PSI) TS section auido, video, program clock reference (PCR) private data and null packets, it displays their contents through a graphic user interface along with the syntax elements of the TS header. Also it displays the decoded I frame nearest in time axis the TS packet currently shown This feature helps pin pointing the specific location of problematic parts in bitstreams. The bitsteam analyzer provides the compliance test of MPEG-2 Systems standard and the data injection functionality with which one can easily insert additional data to existing MPEG-2 bitstreams. Using the resulting system one can produce at low test streams for interactive broadcasting and data broadcasting for laboratory use.

  • PDF

Identification of Developmental Related Genes in the Lab Animal (실험동물 발생 유전자의 확인)

  • Lee, Jae-Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.6
    • /
    • pp.1407-1413
    • /
    • 2009
  • The present study was conducted to gain insights into oocyte maturation and early embryo development, SELDI-TOF-MS was used to find the protein candidates that are specifically or prominently expressed in mouse oocytes at the in vitro matured metaphase II (MIl) and germinal vesicle (GV) stages. By using selected CM10 chip, found 16 candidates which were up-regulated in GV stage oocytes compared with in MIl stage oocytes, molecular weight are 8180 (2 candidates), 10226 (5 candidates), 15767 (5 candidates) and 16770 (4 candidates) Da respectively. And 29 candidates were higher in MIl than in GV stage oocytes, molecular weight are 10832 (3 candidates), 17744(8 candidates), 20122 (3 candidates), 22131 (3 candidates), 24857 (7 candidates) and 33507 (5 candidates) Da, respectively. All (45) candidate (0.2 and 1.0 % error tolerances) were performed real time RT-PCR analysis and further selected 13 more potential candidates.