• Title/Summary/Keyword: PCBs contamination

Search Result 30, Processing Time 0.028 seconds

Deposition Characteristics of Atmospheric PCBs by Type of Leaves in Pine Needles (소나무 종별 대기 중 PCBs의 침착특성)

  • Shin Eun Sang;Yeo Hyun-Gu;Cho Ki-Chul;Chun Man-Young
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.46-52
    • /
    • 2006
  • Results for the concentrations of total polychlorinated biphenyls (total PCBs) and the PCB profile with different types of leaves from four coniferous trees (pine needles) at the same sampling site are presented. Concentrations of total PCBs detected in pine needles were very similar among them regardless of their different types of leaves, which means a possibility for bio-monitoring regional contamination of PCBs. Correlation coefficients(r) of PCB congeners between pine needles were very significant (r>0.97, p<0.001), which showed that PCB congener's patterns of each pine needle were similar. Profiles of PCBs detected in pine needles showed correlation with gaseous phase PCBs in air, otherwise not with particle phase PCBs in air. Therefore, it was estimated that dry gaseous deposition was a principal pathway of PCBs accumulation in pine needles. In addition, although we analyse a different types of leaves in pine needles at the same region, they can be used to identify regional contamination patterns of PCBs for larger regions.

Concentration Distribution of Polychlorinated Biphenyls(PCBs) in Urban Watershed (도심하천유역의 PCBs 농도 분포)

  • Kim, Hyun-Seung;Kim, Il-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.757-766
    • /
    • 2012
  • In this study, we have examined concentration distribution and patterns of PCBs in waters, sediments and soils in an agricultural area of South Korea to investigate the relationship between PCBs sources and concentration levels. The concentration of PCBs in water samples were ranged from lower values below detection limit to 8.25 ug/L and the concentration of PCBs in sediment samples were ranged from lower values below detection limit to 76.67 ug/Kg. The concentration of PCBs in soil samples were ranged from lower values below detection limit to 23.51 ug/Kg. These contamination levels were far below the guideline values suggested for environmental quality assessment. The homologue patterns in samples varied from sample to sample, but isomer patterns were very similar with each other. PCB-138 and PCB-153 were predominant congeners in the soil and sediment, which were similar to the results obtained from previous studies. With these results, the assessment of potential sources of PCBs contamination in the sediments of the Nakdong river basin was performed. The principal components were extracted by Principal Component Analysis(PCA). As the result of PCA, it could be expected that PCBs in samples of this study were more affected by PCB products than combustion processes and mostly affected by already-known sources. The PCBs in the soil and sediment samples were related with commercial PCB products.

A Study on Quantitation of Polychlorinated Biphenyls (PCBs) in Sediments (저니토중 Polychlorinated Biphenyls(PCBs) 정량에 관한 연구)

  • Shin, Ho-Sang;Oh-Shin, Yunsuk
    • Analytical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.151-158
    • /
    • 1999
  • This study was conducted to measure the residual PCBs in sediments of 4 great rivers in Korea by gas chromatography-mass spectrometry. From the results, PCBs were positively detected in all samples. The residue levels of total PCBs in sediments in near of SS and OS were $290.87{\mu}g/kg$ and $221.11{\mu}g/kg$, respectively. The PCBs contamination may be in association with total organic compound (TOC) in sediments. Congener 66, 74, 90, 101, 105, 110, 118, 138, 149, 153, 180, 187 as IUPAC No were predominant species found in sediments and the polyCBs detected most aboundantly in sediments were tetraCBs and pentaCBs. From the study, it appears that the PCBs contamination in sediments of 4 great rivers is not serious and the analysis from enough many sites is needed for the next survey.

  • PDF

Polychlorinated Biphenyl Contaminations of Water, Soils and Sediments Sampled from Various Places of Korea (국내의 다양한 장소에서 채취된 수질, 토양 및 저질시료의 폴리염화비페닐에 의한 오염도)

  • Park, Hyun-Mee;Ryu, Jae-Chun;Kim, Young-Man;Lee, Kang-Bong
    • Analytical Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.802-809
    • /
    • 2000
  • Concentrations of polychlorinated biphenyl congeners (PCBs) in samples collected from 43 kindss of water, 35 kinds of soil and 11 kinds of sediment in various place of Korea have been monitored using GC/MS/SIM analytical method. In our investigation, mean recoveries were $83.8{\pm}10.4%$ for water, $94.9{\pm}12.2%$ for soil and sediment samples and $80.2{\pm}8.7%$ for the spiked $^{13}C{_{12}}$-PCBs. Detection limits of PCBs for water, soil and sediment samples are 0.01 ng/ml and 0.05 ng/g. PCB congeners in water samples were not detected within quantitation limit, but trace amounts were detected in most of soil and sediment samples. The contamination level of PCBs in Korea was evaluated to be lower than in advanced countries like USA, Europe and Japan.

  • PDF

Application of Equilibrium Partitioning Approach for the Assessment of Polychlorinated Biphenyls (PCBs) Contamination in Sediments from Kyeonggi Bay, Namyang Bay, and Lake Shihwa, West Coast of Korea

  • Lee, Kyu-Tae;Tanabe, Shinsuke;Koh, Chul-Hwan
    • Journal of the korean society of oceanography
    • /
    • v.34 no.1
    • /
    • pp.36-42
    • /
    • 1999
  • To assess present status of polychlorinated biphenyls (PCBs) contamination in Kyeonggi Bay, Namyang Bay, and Lake Shihwa, 63 sediment samples were analyzed and applied to equilibrium partitioning approach. Sediment quality criteria (SQC) for exposure to Kanechlor mixture (KC-mix) was calculated as a value of 16 ${\mu}$g/g-organic carbon (OC). Two sites (Sites Kl8 and Kl9) within Incheon North Harbor (INH) with total PCBs concentrations 48 and 38 ${\mu}$g/g-OC, respectively, exceeded SQC, indicating a potential of adverse biological effects. The advantage and disadvantage of equilibrium partitioning approach has been discussed.

  • PDF

Analytical method of the polychlorinated biphenyls in soil using GC/ECD and GC/MS (GC/ECD 및 GC/MS을 이용한 토양 중 PCBs 분석방법 고찰)

  • Kim, Tae-Seung;Shin, Sun-Kyoung;Yoon, Jeong-Ki;Kim, Jong-Ha;Kim, Hyoung Seop;Lee, Jeong Ah
    • Analytical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.91-108
    • /
    • 2007
  • This study was investigated both the Korean official soil test method and the international various methods for PCBs in soil sample. The analytical guideline of PCBs in contaminated soil were proposed based on the official soil test methods by discussing the extraction, column cleanup, instrumental conditions, quantification methods of peak matching and individual isomers. The total 28 soil samples were selected by consideration of PCBs-contamination, land use etc., and then analyzed using gas chromatography/electron capture detection (GC/ECD) and gas chromatography/mass spectrometry(GC/MS). In this study, the PCBs were not detected as peak matching method using GC/ECD, but PCBs detected $0.002{\sim}0.487{\mu}g/kg$ using GC/MS in background concentrations.

Evaluation of PCBs and DDE contamination in terrestrial environment using striped field mouse, Apodemus agrarius (등줄쥐를 이용한 육상환경 중의 PCBs와 DDE의 오염평가)

  • Yoon, Myung-Hee;Kim, Min-Kwan;Min, Byung-Yoon;Choi, Jae-Won
    • Journal of Environmental Science International
    • /
    • v.9 no.3
    • /
    • pp.201-208
    • /
    • 2000
  • PCBs and DDE were determined in the soil samples and the Korean striped field mice, Apodemus agrarius, collected at six localities in Changwon and one locality in Gaduck Island from August 1997 to May 1998. The residual level of PCBs in soils, in which the concentrations of high chlorinated compounds were much higher than those of low chlorinated ones, was highest in the industrial area(IA) in Changwon(60.7 ng/g in average), whereas those of DDE in soils was highest in Gaduck Island(331.9 ng/g in average). However, the levels of each compound detected from soils in the respective remaining places were relatively low. The similar tendency as in the soils was observed in the mice, indicating that the concentration of pollutants in the mice could denote the status of pollution in the terrestrial environment. The composition of PCB congeners in the mice, however, was different from that of soils, but similar to those of other mammals. Moreover, the residual levels of PCBs and DDE in pregnant females from which fetuses were removed were lower than those of males and non-pregnant females. It suggests that these compounds accumulated in pregnant females might have been transferred to the fetuses through placenta as in other mammals. Judging from the above facts, it is suggested that the striped field mouse can be an useful biological index to evaluate the contamination in mammals inhabiting terrestrial environment.

  • PDF

Contamination level and congener profiles of PCBs, Co-PCBs and PCDD/DFs in transformer insulation oil samples (변압기 절연유 중 PCBs, Co-PCBs 및 PCDD/PCDFs 오염수준 및 이성체 분포)

  • Kim, Kyoung-Soo;Kim, Jong-Guk;Shin, Sun-Kyoung;Kim, Kyoung-Sim;Song, Byung-Joo
    • Analytical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.263-271
    • /
    • 2006
  • The levels of total PCBs, Co-PCBs and PCDD/Fs in the transformer insulation oil samples obtained using GC/ECD and HRGC/HRMS were ranged from N.D. to 77.3 ppm, from 0.0863 to 2.49 ppm and from N.D. to 0.00241 ppm, respectively. In terms of WHO-TEQ values, Co-PCBs and PCDD/Fs were ranged from 23.3 to 600 pgTEQ/g and from N.D. to 128 pgTEQ/g, respectively (${\Sigma}Co$-PCBs+PCDD/Fs concentration was calculated 24.4~728 pgTEQ/g). Although, the contribution of PCDD/Fs was below 12% in total TEQ concentration, it is suggested contamination of PCDD/Fs in transformer insulation oils. Among 10 samples, 4 samples showed higher concentration than 2 ppm (specific waste criterion of Korea) and Aroclor 1242, 1248, 1254 and 1260 was detected in samples as a single or mixture of Aroclor. It was shown reliable relationship between concentration of Co-PCBs and those of PCDD/Fs (p<0.003), however, was not shown between production year of transformer and concentration of PCBs. The distribution pattern of Co-PCB congeners showed that the ratios of mono-ortho substituted congeners were higher than non-ortho substituted congeners. Among that, PCB-118 congener was predominant. In addition, the OCDD congener was predominated in PCDD/Fs congeners as above 53%. Moreover, the congener pattern of Co-PCBs was similar to that of Aroclor as well as ambient air, which suggested that PCBs volatilization from transformer insulation oil affected the pattern of Co-PCBs in ambient air.

A Study on The Sampling Error of PCBs Deposited on Pine Needles (소나무잎에 침착된 PCBs의 샘플링 오차에 관한 연구)

  • Chun, Man-Young;Kim, Tae-Wook
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.2
    • /
    • pp.117-121
    • /
    • 1998
  • In the study to reduce the error on the method of sampling pine needles to monitor the atmospheric concentration of polychlorinated biphenyls(PBCs),it was found that: 1. Concentration of PCBs almost linearly increased from new to three-years-old pine needles, so that the biomonitoring method using pine needles canbe applied to measuring long-term contamination from air in a local area. Needles of differernt age should not be mixed in sampling but be seperately analysed .It no good idea comparing PCB concentrations of differently aged needles. 2. Concentratio n of PCBs on pine needles had nothing to do whit the indivisual and age of the pine tree. 3. Concentration of PCBs on pine needles growing avobe was lower than that on needke below. 4. Concentration of PCBs on pine needles locatied in poorly ventilative places such as needle of a forest was lower than that on needles in well-ventilated areas.

  • PDF