• 제목/요약/키워드: PC film

검색결과 309건 처리시간 0.031초

진공증착법을 이용한 압전 유기 박막의 제조와 센서 특성에 관한 연구 (A Study on the Fabrication of Piezoelectric Organic Thin Films by using Physical Vapor Deposition Method and Sensor Characteristics)

  • 박수홍;임응춘;박종찬;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.35-39
    • /
    • 2001
  • The purpose of this paper is improvement the piezoelectric of Polyvinylidene fluoride(PVDF) organic thin films is fabricated by vapor deposition method. The piezoelectric of PVDF organic thin films attributed to dipole orientation in crystalline region. Also, the piezoelectric characteristic reduced that dipole moments orientation in crystalline region interfered with impurity carriers. Therefore, PVDF organic thin films fabricated with high substrate temperature condition for crystallinity improvement. The crystallinity of PVDF organic thin films fabricated by this condition increase from 47 to 67.8%. The ion density of PVDF organic thin films fabricated by substrate temperature variation from $30^{\circ}C$ to $105^{\circ}C$ decreased from $1.62{\times}10^{16}cm^3$ to $6.75{\times}10^{11}cm^3$ when temperature and frequency were $100^{\circ}C$, 10Hz, respectively. The $d_{33}$ and piezo-voltage coefficient of PVDF organic thin films increased from 20pPC/N to 33pC/N and $162.9{\times}10^{-3}V{\cdot}m/N$ to $283.2{\times}10^{-3}V{\cdot}m/N$, respectively. For the sake of the applications of piezoelectric sensor, we analyzed the output voltage characteristic as a function of the distance between an oscillator of 28kHz and PVDF organic thin film transducer. From this, we found that the output voltage is inversely proportional to the distance. At this time, the period was about $35.798{\mu}s$ and equal the oscillator frequency.

  • PDF

Electrochemical double layer capacitors with PEO and Sri Lankan natural graphite

  • Jayamaha, Bandara;Dissanayake, Malavi A.K.L.;Vignarooban, Kandasamy;Vidanapathirana, Kamal P.;Perera, Kumudu S.
    • Advances in Energy Research
    • /
    • 제5권3호
    • /
    • pp.219-226
    • /
    • 2017
  • Electrochemical double layer capacitors (EDLCs) have received a tremendous interest due to their suitability for diverse applications. They have been fabricated using different carbon based electrodes including activated carbons, single walled/multi walled carbon nano tubes. But, graphite which is one of the natural resources in Sri Lanka has not been given a considerable attention towards using for EDLCs though it is a famous carbon material. On the other hand, EDLCs are well reported with various liquid electrolytes which are associated with numerous drawbacks. Gel polymer electrolytes (GPE) are well known alternative for liquid electrolytes. In this paper, it is reported about an EDLC fabricated with a nano composite polyethylene oxide based GPE and two Sri Lankan graphite based electrodes. The composition of the GPE was [{(10PEO: $NaClO_4$) molar ratio}: 75wt.% PC] : 5 wt.% $TiO_2$. GPE was prepared using the solvent casting method. Two graphite electrodes were prepared by mixing 85% graphite and 15% polyvinylidenefluoride (PVdF) in acetone and casting n fluorine doped tin oxide glass plates. GPE film was sandwiched in between the two graphite electrodes. A non faradaic charge discharge mechanism was observed from the Cyclic Voltammetry study. GPE was stable in the potential windows from (-0.8 V-0.8 V) to (-1.5 V-1.5 V). By increasing the width of the potential window, single electrode specific capacity increased. Impedance plots confirmed the capacitive behavior at low frequency region. Galvanostatic charge discharge test yielded an average discharge capacity of $0.60Fg^{-1}$.

콜로이드실리카아크릴레이트를 함유한 자외선 경화형 코팅필름의 특성 (Properties of UV Curable Coating Film Containing Colloidal Silica Acrylate)

  • 이봉우;홍진후;방문수;오형식;김대준;김현중
    • 접착 및 계면
    • /
    • 제4권1호
    • /
    • pp.9-17
    • /
    • 2003
  • 오늘날 산업에서는 환경오염의 줄이고 에너지 절약에 기여할 수 있다는 이유에서 용매를 사용하지 않는 UV 하드코팅재료의 개발이 점차로 많은 주의를 끌고 있다. 본 연구는 실질적으로 산업에 이용될 수 있는 실리콘아크릴레이트(SAOC)를 포함하고 있는 UV 경화코팅제를 개발하고자 수행되었다. 실험의 결과, 수지조성물 중 SAOC의 형태나 농도가 UV 경화필름의 여러 가지 물성에 영향을 주었다. SAOC가 수지조성물에 도입되었을 때 경화된 필름의 물성은 SAOC가 함유되지 않은 도막과 비교하여 개선되었다. 특히, UV 하드 코팅의 내화학성, 내마모성, 내후성과 같은 성질들은 향상되었으며, 코팅된 폴리카보네이트 기재의 충격특성은 코팅되지 않은 PC에 비해 개선되었다. 30 wt% SAOC를 함유하고 있는 경화필름이 가장 좋은 물성을 나타내었다.

  • PDF

16M-Color LTPS TFT-LCD 디스플레이 응용을 위한 1:12 MUX 기반의 1280-RGB $\times$ 800-Dot 드라이버 (A 1280-RGB $\times$ 800-Dot Driver based on 1:12 MUX for 16M-Color LTPS TFT-LCD Displays)

  • 김차동;한재열;김용우;송남진;하민우;이승훈
    • 대한전자공학회논문지SD
    • /
    • 제46권1호
    • /
    • pp.98-106
    • /
    • 2009
  • 본 논문에서는 ultra mobile PC (UMPC) 및 휴대용 기기 시스템 같이 고속으로 동작하며 고해상도 저전력 및 소면적을 동시에 요구하는 16M-color low temperature Poly silicon (LTPS) thin film transistor liquid crystal display (TFT-LCD) 응용을 위한 1:12 MUX 기반의 1280-RGB $\times$ 800-Dot 70.78mW 0.13um CMOS LCD driver IC (LDI) 를 제안한다. 제안하는 LDI는 저항 열 구조를 사용하여 고해상도에서 전력 소모 및 면적을 최적화하였으며 column driver는 LDI 전체 면적을 최소화하기 위해 하나의 column driver가 12개의 채널을 구동하는 1:12 MUX 구조로 설계하였다. 또한 신호전압이 rail-to-rail로 동작하는 조건에서 높은 전압 이득과 낮은 소비전력을 얻기 위해 class-AB 증폭기 구조를 사용하였으며 고화질을 구현하기 위해 오프 셋과 출력편차의 영향을 최소화하였다 한편, 최소한의 MOS 트랜지스터 소자로 구현된 온도 및 전원전압에 독립적인 기준 전류 발생기를 제안하였으며, 저전력 설계를 위하여 차세대 시제품 칩의 source driver에 적용 가능한 새로운 구조의 slew enhancement기법을 추가적으로 제안하였다. 제안하는 시제품 LDI는 0.13um CMOS 공정으로 제작되었으며, 측정된 source driver 출력 정착 시간은 high에서 low 및 low에서 high 각각 1.016us, 1.072us의 수준을 보이며, source driver출력 전압 편차는 최대 11mV를 보인다. 시제품 LDI의 칩 면적은 $12,203um{\times}1500um$이며 전력 소모는 1.5V/5.5V 전원 저압에서 70.78mW이다.

Integrated Rotary Genetic Analysis Microsystem for Influenza A Virus Detection

  • Jung, Jae Hwan;Park, Byung Hyun;Choi, Seok Jin;Seo, Tae Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.88-89
    • /
    • 2013
  • A variety of influenza A viruses from animal hosts are continuously prevalent throughout the world which cause human epidemics resulting millions of human infections and enormous industrial and economic damages. Thus, early diagnosis of such pathogen is of paramount importance for biomedical examination and public healthcare screening. To approach this issue, here we propose a fully integrated Rotary genetic analysis system, called Rotary Genetic Analyzer, for on-site detection of influenza A viruses with high speed. The Rotary Genetic Analyzer is made up of four parts including a disposable microchip, a servo motor for precise and high rate spinning of the chip, thermal blocks for temperature control, and a miniaturized optical fluorescence detector as shown Fig. 1. A thermal block made from duralumin is integrated with a film heater at the bottom and a resistance temperature detector (RTD) in the middle. For the efficient performance of RT-PCR, three thermal blocks are placed on the Rotary stage and the temperature of each block is corresponded to the thermal cycling, namely $95^{\circ}C$ (denature), $58^{\circ}C$ (annealing), and $72^{\circ}C$ (extension). Rotary RT-PCR was performed to amplify the target gene which was monitored by an optical fluorescent detector above the extension block. A disposable microdevice (10 cm diameter) consists of a solid-phase extraction based sample pretreatment unit, bead chamber, and 4 ${\mu}L$ of the PCR chamber as shown Fig. 2. The microchip is fabricated using a patterned polycarbonate (PC) sheet with 1 mm thickness and a PC film with 130 ${\mu}m$ thickness, which layers are thermally bonded at $138^{\circ}C$ using acetone vapour. Silicatreated microglass beads with 150~212 ${\mu}L$ diameter are introduced into the sample pretreatment chambers and held in place by weir structure for construction of solid-phase extraction system. Fig. 3 shows strobed images of sequential loading of three samples. Three samples were loaded into the reservoir simultaneously (Fig. 3A), then the influenza A H3N2 viral RNA sample was loaded at 5000 RPM for 10 sec (Fig. 3B). Washing buffer was followed at 5000 RPM for 5 min (Fig. 3C), and angular frequency was decreased to 100 RPM for siphon priming of PCR cocktail to the channel as shown in Figure 3D. Finally the PCR cocktail was loaded to the bead chamber at 2000 RPM for 10 sec, and then RPM was increased up to 5000 RPM for 1 min to obtain the as much as PCR cocktail containing the RNA template (Fig. 3E). In this system, the wastes from RNA samples and washing buffer were transported to the waste chamber, which is fully filled to the chamber with precise optimization. Then, the PCR cocktail was able to transport to the PCR chamber. Fig. 3F shows the final image of the sample pretreatment. PCR cocktail containing RNA template is successfully isolated from waste. To detect the influenza A H3N2 virus, the purified RNA with PCR cocktail in the PCR chamber was amplified by using performed the RNA capture on the proposed microdevice. The fluorescence images were described in Figure 4A at the 0, 40 cycles. The fluorescence signal (40 cycle) was drastically increased confirming the influenza A H3N2 virus. The real-time profiles were successfully obtained using the optical fluorescence detector as shown in Figure 4B. The Rotary PCR and off-chip PCR were compared with same amount of influenza A H3N2 virus. The Ct value of Rotary PCR was smaller than the off-chip PCR without contamination. The whole process of the sample pretreatment and RT-PCR could be accomplished in 30 min on the fully integrated Rotary Genetic Analyzer system. We have demonstrated a fully integrated and portable Rotary Genetic Analyzer for detection of the gene expression of influenza A virus, which has 'Sample-in-answer-out' capability including sample pretreatment, rotary amplification, and optical detection. Target gene amplification was real-time monitored using the integrated Rotary Genetic Analyzer system.

  • PDF

Hot Wall Epitaxy(HWE)법에 의한 MnAl2S4 단결정 박막 성장과 광전도 특성 (Growth and optical conductivity properties for MnAl2S4 single crystal thin film by hot wall epitaxy method)

  • 유상하;이기정;홍광준;문종대
    • 한국결정성장학회지
    • /
    • 제24권6호
    • /
    • pp.229-236
    • /
    • 2014
  • 수평 전기로에서 $MnAl_2S_4$ 다결정을 합성하여 HWE(Hot Wall Epitaxy)방법으로 $MnAl_2S_4$ 단결정 박막을 반절연성 GaAs(100)기판에 성장시켰다. $MnAl_2S_4$ 단결정 박막의 성장 조건은 증발원의 온도 $630^{\circ}C$, 기판의 온도 $410^{\circ}C$였고 성장 속도는 $0.5{\mu}m/hr$였다. 이때 $MnAl_2S_4$ 단결정 박막의 결정성의 조사에서 이중결정 X-선 요동곡선(DCRC)의 반폭치(FWHM)도 132 arcsec로 가장 작아 최적 성장 조건임을 알 수 있었다. $MnAl_2S_4$/SI(Semi-Insulated) GaAs(100) 단결정 박막의 광흡수를 293 K에서 10 K까지 측정하였다. 광흡수 스펙트럼으로부터 band gap $E_g(T)$는 Varshni 공식에 따라 계산한 결과 $E_g(T)=3.7920eV-(5.2729{\times}10^{-4}eV/K)T^2/(T+786K)$였다. $MnAl_2S_4$ 단결정 박막의 응용소자인 photocell로 사용할 수 있는 pc/dc 값이 가장 큰 광전도셀은 S 증기분위기에서 열처리한 셀로 $1.10{\times}10^7$이었으며, 광전도 셀의 감도(sensitivity)도 S 증기분위기에서 열처리한 셀이 0.93로 가장 좋았다. 또한 최대 허용소비전력(MAPD)값도 S 증기분위기에서 열처리한 셀이 316 mW로 가장 좋았으며, S 증기분위기에서 열처리한 셀의 응답시간은 오름시간 14.8 ms, 내림시간 12.1 ms로 가장 빠르게 나타나, $MnAl_2S_4$ 단결정 박막을 S 분위기에서 $290^{\circ}C$로 30분 열처리한 photocell이 상용화가 가능할 것으로 여겨진다.

소형 모바일 디스플레이의 영상 컨트라스트 및 야외시인성 개선 기법 (Image Contrast and Sunlight Readability Enhancement for Small-sized Mobile Display)

  • 정진영;모니르 호쎈;최우영;김기두
    • 전기전자학회논문지
    • /
    • 제13권4호
    • /
    • pp.116-124
    • /
    • 2009
  • 근래 휴대 단말기용 모뎀 칩셋이나 멀티미디어 프로세서의 CPU성능은 노트북PC에 버금가는 수준으로 향상되면서 휴대단말기가 전자기기의 컨버전스화를 주도하는 아이콘으로 떠오르고 있다. 더불어 DMB, 디지털 카메라, 화상통화, 인터넷 검색 등이 기본적으로 제공되면서 소형크기의 휴대 단말기용 디스플레이에서도 화질에 대한 관심이 높아지고 있다. 휴대단말기의 경우 야외에서 태양광과 같은 주변광원의 변화로 동일한 영상이 열화 또는 과도하게 밝아져 보이는 야외 시인성 문제를 해결해야 하며, 더구나 최근 터치방식 패널이 휴대단말기 디스플레이 장치에 사용되면서 ITO 필름에 의한 투과율 손실로 디스플레이 화면의 컨트라스트 저하가 더해지고 있다. 본 논문에서는 휴대 단말기용 영상개선 SoC를 위해 영상 개선 알고리즘을 개발하였고 이에 대한 성능 비교를 수행하였다. 컨트라스트 개선을 위해 적응형 기법으로 Clipped Histogram Stretching을, 정적 기법으로 S형 곡선조정과 Gain 조정 기법을 사용하였고 야외 시인성 개선을 위해서는 CIELCh 색공간에서 외부 조도센서의 정보에 따라 명도(Lightness)와 채도(Chroma)가 조절될 수 있도록 하였다. 개발한 알고리즘에 대한 성능평가는 결과영상의 히스토그램, RGB 화소값 분포도, 엔트로피 그리고 동적영역 확장비 등을 통해 분석을 진행하였다.

  • PDF

경혈정위 보조도구의 정확성 및 편의성 평가 연구 (A Study of Accuracy and Usability for Acupuncture Points Locating Devices)

  • 채윤병;강오석;함대현;이승호;김재순;김관형;김희영;이혜정;박히준
    • Korean Journal of Acupuncture
    • /
    • 제24권2호
    • /
    • pp.61-76
    • /
    • 2007
  • Objectives : Accurate and reproducible location of an acupuncture point (AP) have been considered an essential component of meaningful acupuncture research as well as clinical practice. Several kinds of devices have been developed and widely used for the convenience of locating APs. However, the accuracy and convenience of these devices have not been systematically evaluated. The present study was performed to find out the most suitable tools for the location accuracy and location easiness of APs among the devices respectively. Methods : Twenty subjects attempted to locate APs, including PC5 and SP6 in the arm and leg, using four different AP positioning methods: one Conventional Ruler method and three alternative methods including Cunometer, Transparent AP meter, and Elastic Ruler method. The position marked on each AP was plotted onto a thin, flexible, and transparent plastic film, and the dispersion rate of the positions was determined and recorded. The elapsed time for locating each AP was measured. After that each subject was answered to a short questionnaire regarding the degree of convenience and confidence of use of each method for AP location. Results : All of three alternative methods took less time than Conventional Ruler method did. Among these alternative methods, the accuracy of Elastic Ruler method was markedly higher than others. The degree of convenience of the Cunometer and the confidence of Elastic Ruler method were the highest among these alternative methods. Conclusions : The present study indicates that the Elastic Ruler method was the most compatible for the conventional Ruler methods. However, there are many factors need to be reconsidered. Improved devices for locating AP are imperatively needed for clinical practice.

  • PDF

기본 간호학 실습교육에서 모듈 학습자료 개발과 그 효과 연구 - 감염과 배설에 관한 실습 교육을 중심으로 (Study on the Development of Modularized Instruction and the Effect of Its Application - Focused on the Asepsis and Elimination Practice -)

  • 정현숙
    • 대한간호
    • /
    • 제33권3호
    • /
    • pp.56-69
    • /
    • 1994
  • This study was done to develop self - directed learning modules related to asepsis and elimination including urine and stool for Fundamentals in Nursing practice education contents and to measure the effectiveness of those modules. The subjects of this study were 96 sophomore students in the nursing college. Self-directed learning modules were developed by the researcher on the basis of the Lippincott Learning System of Kruger (1986) and Modules for Basic Nursing Care of Ellis (1992). Videotape was editted by using videotape made by the Lippincott Company and Film strip made by the Trainex Company with Korean dubbing. Self-directed learning was done for one week with the asepsis module and two weeks with the elimination modules after confirming the requiered level of knowledge acquisition through pre-test. For measuring proficiency in self-directed learning, a written test for cognitive domain, a sufficiency test for psychomotor domain, and a confidnece examination for affective domain were given. The data were analyzed using descritive statistics, and Pearson correlation coefficient using a SPSS-PC program. The results are summarized as follows: 1. Sufficiency test and confidence examination grades showed high levels in both asepsis and elimination. 2. Written test grades showed a high level in asepsis and elimination of urine but showed a medium level in eliminationin of stool. 3. Grades of sufficiency and confidence in asepsis and elimination practice were statistically significant with a moderate positive correlation (r=0.4- 0.5, p<0.001). 4. Grades of sufficiency and written tests in asepsis and elimination practice also were statistically significant with a moderate positive correlation (r=0.5-0.7, p<0.001). 5. Students showed relatively high contentment with the self-directed learning modules themselves but revealed relatively low contentment with video program and the self-directed learning process. In conclusion, this study disclosed that proficiency levels in cognitive, affective, and psychomotor domains were high when asepsis and elimination modules were applied. Also students showed high satisfaction with the modules themselves, but didn't show high contentment with the video programs. In considering low contentment with the self-directed learning process, it is estimated the students had experienced some difficulties about using self-directed learning modules because this was their first exposure to the self-directed learning module and they were already accustomed to the demonstration-practice method.

  • PDF

$TiO_2$ 필러를 포함하는 PEO/PMMA 고분자 복합체 전해질의 이온전도도 및 결정화도 (Study on Ionic Conductivity and Crystallinity of PEO/PMMA Polymer Composite Electrolytes containing $TiO_2$ Filler)

  • 이륜규;박수진;김석
    • Korean Chemical Engineering Research
    • /
    • 제49권6호
    • /
    • pp.758-763
    • /
    • 2011
  • 본 연구에서는 poly(ethylene oxide) (PEO)와 poly(methyl methacrylate) (PMMA) 블렌드를 고분자 매트릭스(matrix)로 사용하고, 가소제로propylene carbonate (PC), 리튬염인 $LiClO_4$, 그리고 서로 다른 함량의 세라믹 필러인 $TiO_2$를 이용하여 용액 캐스팅(solution casting)법에 의해 고분자 복합체 전해질 필름을 제조하였다. 고분자 전해질의 결정화도와 이온전도도는 각각, X선 회절분석기(XRD)와 AC임피던스법을 통해 분석하였고, 표면 형태학(morphology)을 조사하기 위해 주사전자현미경(SEM)으로 고찰하였다. 그 결과, $TiO_2$의 함량을 증가시킴으로써 PEO의 결정화 영역이 감소하였고, 이온전도도는 증가하였다. 특히 $TiO_2$의 함량이 15 wt%일 때 가장 높은 이온전도도가 관찰된 반면, 15 wt% 이상을 첨가한 경우, 이온전도도가 감소된 경향을 관찰할 수 있었다. 이는 표면 형태학를 통해 고분자와 필러간의 비혼합성 혹은 필러응집에 의해 불균일적인 형태학이 나타남으로써 이온전도도가 감소하는 현상을 확인할 수 있었다.